Xantech 48195D User Manual

MODEL
48195D
Dinky Link™ Surface Mount
UniversalIR Receiver
INSTALLATION INSTRUCTIONS
DESCRIPTION
These small IR receivers have been designed for mounting in very small spaces. They may be mounted under shelf edges, cabinet ledges, in wall speakers, etc. – anywhere an inconspicuous appearance is desired. The high sensitivity of these receivers allows placement behind speaker grilles and still receive IR commands up to 100 feet away*.
FEATURES
Wire channel for clean installation. System testing red-talk-back LED. Includes 3-Terminal Block for easy extension to remote room locations.
SPECIFICATIONS
Infrared carrier frequency bandwidth: 25 - 100kHz. Reception range: Up to 100 feet.* Reception angle: +/- 60 degrees. Cable requirements: See “INSTALLATION” below. Max. transmission length: 1 mile using 18 gauge wire. Maximum current output: 100mA Drives IR emitters through Xantech Connecting Blocks, Controllers, etc. Dimensions: 2.55” x 0.55” x 0.35” (65mm x 14mm x 9mm) Power requirements: +12VDC, 20mA. Depending on remote control output strength and ambient conditions.
MOUNTING
The IR receiver can be mounted to any flat surface, using the two-sided adhesive tape supplied. Two screws are included for mounting the 3-terminal block provided with the IR receiver.
An additional feature is a wire channel on the rear of the surface mount IR receiver. This will give the installer the ability to provide clean wire dressing in any direction.
PLACEMENT
The IR receiver should be located so that it is not directly facing a light source such as lamps or displays (standard, LCD, and Plasma). When mounted near a display, it should be flush to the display and away from light reflections that may occur.
SENSITIVITY ADJUSTMENT
Located on the bottom side of the IR receiver, the sensitivity adjustment allows fine adjustment of the reception range and performance in various environments. For example, if there is too much light interference affecting the performance of the IR receiver, the sensitivity can be decreased. Also, if the talk-back LED is constantly lit, sensitivity needs to be decreased until proper remote operation is achieved.
Clockwise – Increase Sensitivity Counter-Clockwise – Decrease Sensitivity
Limited Warranty
Xantech® warrants its products to be free of defects in materials or workmanship. This is a Limited Lifetime warranty from the date of purchase by the original consumer. Any products returned to Xantech and found to be defective by Xantech within the warranty period will be repaired or replaced, at Xantech’s option, at no charge. Xantech will not be responsible for the actual cost of installation or removal of the product, nor for any incidental or consequential damages. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to you. This warranty gives you specific legal rights. You may have additional legal rights that vary from state to state.
Xantech Corporation
13100 Telfair Ave., Sylmar CA 91342 | Xantech.com
Installation Instructions, 48195D © 2009 Xantech Corporation