X10 DW534 User Manual

Door/Window Sensor, Model DW534 Set Up and Operating Instructions
Installation
1. Secure the magnet and switch on the DW534 together with a rubber band.
2. Install a 9V alkaline battery in the battery compartment on the DW534.
3. Make sure the switch inside the battery compartment is set to N.C. (Normally Closed). This is the type of magnetic switch supplied with the DW534.
5. Set the INSTALL/RUN switch on the Security Console to INSTALL.
6. Press TEST on the DW534. T he Console emits a tone and the next unused zone indicator lights up.
7. Set the Console's slide switch back to R UN1 or RUN2.
8. T o set up additional Door/Windo w Sensors (up to 16*) repeat the above steps.
9. Set the DW534’s DELAY switch to MAX to protect a door or to MIN to protect a window.
10. Remove the rubber band and attach the DW534 to the door or window frame using the double sided tape or screws supplied.
*Note: you can install a total of 16 zones in the Console. This can be a combination of Door/Window Sensors and Motion Detectors. E.G. 8 Door/Window Sensors AND 8 Motion Detectors. See your Security System Owner’s
Manual for more information.
When the security system IS armed, opening a door or window tr ips the alarm. If the DW534 is set to MIN the alarm trips instantly. If the DW534 is set to MAX there is a 30 second delay before the alarm trips after you open the door or window.
Replacing batteries
Slide the battery compartment cover off and replace the battery with a 9V alkaline type. After replacing the battery, the following steps are necessary to determine that the Console still recognizes the DW534.
1. Place the Console’s slide switch to RUN2.
2. Press TEST on the DW534. If the Console chimes, it
recognizes the DW534 and no further action is necessary.
If the Console did not chime:
1. Place the Console’s slide switch to INSTALL.
2. Pr ess TEST on the DW534. The D W534’ s red indicator
light flashes once, and DW534 transmits a random code to the console. The Console acknowledges this with a beep and logs in the DW534 to the next a vailable zone. To make sure the Console logs the DW534 back into the same zone it was allocated to befor e you changed the battery, wait 4 hours after removing the old battery before reinstalling (until the zone indicator on the Console starts flashing).
TEST
MAX
DELAY
MIN
CODE
Door/Window
Sensor
Operation
When the security system is NOT armed and the Console is set to R UN2 , the Console chimes when you open a door or window protected by the D W534. The red indica tor light for that zone on the Console also lights up. In R UN1 mode there are no chimes.
X-10 (USA) Inc., 91 Ruckman Rd., Closter, NJ 07624. http://www.x10.com
X-10 (USA) INC. LIMITED 1-YEAR WARRANTY
X-10 (USA) Inc. warrants X-10 products to be free from defective material and workmanship for a period of one (1) year from the original date of purchase at retail. X-10 (USA) Inc. agrees to repair or replace, at it’s sole discretion, a defective X-10 product if returned to X-10 (USA) Inc. within the warranty period and with proof of purchase.
If service is required under this warranty:
1. Return the defective unit postage prepaid to X-10 (USA) Inc. at the address below.
2. Enclose a check for $4.00 to cover postage and handling.
3. Enclose a dated proof of purchase.
4. X-10 is not responsible for shipping damage.
DW534-998DR
Loading...