WyreStorm recommends reading through this document in its entirety to become familiar with the product’s features prior to starting the installation
process.
A 6x6 or 8x8 Class A HDBaseT 4K Matrix Switcher with support for 2 or 3 ARC zones, using the latest in HDCP 2.2 encryption technology.
Note: The following information applies to version 2 of this product as identied by v2 after the model number on the product label.
IMPORTANT! Installation Requirements
Visit the product page to download the latest rmware, document version,
additional documentation, and conguration tools.
Install the latest rmware to ensure that all features described in this document are available during and after installation.
• Read through the Wiring and Connections section for important wiring guidelines before creating or choosing premade cables.
Recommended Products
To take full advantage of the features of this matrix, WyreStorm recommends the following products be used within the system.
• RX-70-4K-ARC HDBaseT Receiver – Use this receiver when support for ARC functions of outputs 5-6 (6x6) and 6-8 (8x8) is required.
• RX-70-4K HDBaseT Receiver – Use this receiver for outputs 1-4 (6x6) and 1-5 (8x8) or when ARC is not required.
• CAB-IR-LINK – Use this cable when using an IR control system for matrix control of HDBaseT pass-through.
In The Box
1x MX-0606-HDBT-H2 or MX-0808-HDBT-H2 Matrix Switcher 1x IR Remote Handset 1x IR Receiver (38Khz) 6/8x Wide-band IR Receivers (30-50KHz) 6/8x IR Emitters 1x USB to DB9 RS-232 Cable 1x 100~240V AC 50/60Hz Power Cord with US Plug 1x 100~240V AC 50/60Hz Power Cord with UK Plug 1x 100~240V AC 50/60Hz Power Cord with EU Plug 2x Mounting Brackets 1x Quickstart Guide (this document)
Additional Information
This Quickstart Guide provides the basic steps for the common uses of this
product. Detailed installation and conguration information may be found in
the download tab located on the product page.
• WebUI Reference Guide – Setup for advanced Matrix features such as IP and testing of connections
• H2 Matrix Operation User Guide – Single page document showing the operation via front panel and included IR remote.
Drivers and API – Precongured drivers for popular control systems and API document.
Key
HDMI/Digital Video
HDBaseT/Ethernet
Digital Audio
IR
RS-232
MX-0606-HDBT-H2
RX-70-4K-ARC
Router
Control System
CAB-IR-LINK (Sold
Separately)
Multi-channel Audio from
Remote Zone
AV Receiver
UHD Source
Basic Wiring Diagram
Wiring and Connections
WyreStorm recommends that all wiring for the installation is run and terminated prior to making connections to the switcher. Read through this section in this entirety before running or terminating the wires to ensure proper operation and to avoid damaging equipment.
HDMI/HDBaseT Wiring
IMPORTANT! Wiring Guidelines
• The use of patch panels, wall plates, cable extenders, kinks in cables, and electrical or environmental interference will have an adverse effect on HDMI and Ethernet transmission limiting performance. Steps should be taken to minimize or remove these factors completely during installation for best results.
• WyreStorm recommends using high quality HDMI cables such as WyreStorm Express to ensure the highest content performance available.
• The type of category cable and length used can restrict the available video resolution. While Cat5e can be used, WyreStorm recommends using Cat6 or higher to ensure the highest content performance available. See Video Resolutions in the Specications table before determining cable type and length.
Pin 1
Pin 8
Wire colors shown follow EIA/TIA-568B standard.
Pin 1:
Pin 2:
Pin 3:
Pin 4:
Pin 5:
Pin 6:
Pin 7:
Pin 8:
White/Orange
Orange
White/Green
Blue
White/Blue
Green
White/Brown
Brown
IR TX/RX Wiring
IMPORTANT! IR TX/RX Guidelines
• WyreStorm IR ports function differently than standard IR ports. For this reason only WyreStorm IR emitters and receivers can be used.
• WyreStorm IR emitter and receiver cables cannot be spliced as cutting into the cables will short the shield. While an extension cable may be used, WyreStorm assumes no responsibility for operation using an extension cable.
• When connecting the IR TX to an IR connecting blocks or control system with different plugs, a cable must be made following the IR TX Port Pinout diagram.
• When connecting to an IR control system use the WyreStorm CAB-IR-LINK cable. This cable compensates for differences between the WyreStorm RX and the control systems TX connection. Visit the WyreStorm CAB-IR-LINK product page for details.
IR TX Port Pinout
Tip: Anode/5V
Sleeve: Cathode/IR Signal
IR RX Port Pinout
Tip:
Ring: IR Signal
+5V DC
Sleeve: Ground (GND)
RS-232 Wiring
Most control systems and computers are DTE where pin 2 is RX, this can vary from device to device. Refer to the documentation for the connected device for pin functionally to ensure that the correct connections can be made.
5
9 8 7 6
4 3 2 1
Outside of DB9 chassis port shown.
Unidnetified pins have no function and should
not be connected.
Pin 3: RX (Receive) Pin 2: TX (Transmit)
Pin 5: GND (Ground)