R
INSTALLATION
AND
OPERATING
INSTRUCTIONS
Models: PC-1A & MPC-1A
POPCORN POPPERS
Initial heating of appliance may generate smoke or fumes and must be done in a well ventilated area.
Overexposure to smoke or fumes may cause nausea or dizziness.
This equipment has been engineered to provide you with year-round dependable service when used
according to the instructions in this manual and standard commercial kitchen practices.
Phone: +1 (307) 634-5801
Fax: +1 (307) 637-8071
Toll Free: +1 (800) 752-0863
Website: www.apwwyott.com
E-mail: info@apwwyott.com
TOASTER MUST BE KEPT CLEAR OF COMBUSTIBLES AT ALL TIMES
FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
WARNING: Improper installation, adjustment, alteration, service or maintenance can
cause property damage, injury or death. Read the Installation, Operating and
Maintenance Instructions thoroughly before installing or servicing this equipment.
INTENDED FOR OTHER THAN HOUSEHOLD USE
RETAIN THIS MANUAL FOR FUTURE REFERENCE
!!
!!
P/N 46710500 11/05
APW WYOTT
P.O. Box 1829
Cheyenne, WY 82003
1
IMPORTANT SAFETY INSTRUCTIONS
IMPORTANT: Read the following important safety instructions to avoid personal injury or
!
!
!
!
!
!
death, and to avoid damage to the equipment or property.
CAUTION: These models are designed, built, and sold for commercial use. If these models are
positioned so the general public can use the equipment make sure that cautions, warnings, and
operating instructions are clearly posted near each unit so that anyone using the equipment will
use it correctly and not injure themselves or harm the equipment.
WARNING: Check the data plate on this unit before installation. Connect the unit only to the voltage
and frequency listed on the data plate. Connect only to 1 or 3 phase as listed on the data plate.
WARNING: Improper installation, operation, adjustment, alteration, service or maintenance can
cause property damage, injury or death. Read and understand these instructions thoroughly before
positioning, installing, maintaining or servicing this equipment.
WARNING: Electrical and grounding connections must comply with the applicable portions of the
national electrical code and/or other local electrical codes.
WARNING: Disconnect device from electrical power supply and place a Tag Out-Lockout on the
power plug, indicating that you are working on the circuit.
!
!
!
!
!
!
WARNING: Install per the spacing requirements listed in the installation section of this manual. We
strongly recommend having a competent professional install the equipment. A licensed electrician
should make the electrical connections and connect power to the unit. Local codes should always
!
be used when connecting these units to electrical power. In the absence of local codes, use the
latest version of the National Electrical Code.
WARNING: A factory authorized agent should handle all maintenance and repair. Before doing any
!
maintenance or repair, contact APW Wyott.
WARNING: Never clean any electrical unit by immersing it in water. Turn off before cleaning
!
surface.
WARNING: An earthing cable must connect the appliance to all other units in the complete
installation and from there to an independent earth connection.
!
NOTICE: The unit when installed, must be electrically grounded and comply with local codes, or in
the absence of local codes, with the national electrical code ANSI/NFPA70- latest edition.
!
Canadian installation must comply with CSA-STANDARD C.22.2 Number 0 M1982 General
Requirements-Canadian Electrical Code Part II, 109-M1981- Commercial Cooking Appliances.
NOTICE: Local codes regarding installation vary greatly from one area to another. The National
Fire Protection Association, Inc. states in its NFPA96 latest edition that local codes are “Authority
Having Jurisdiction” when it comes to requirement for installation of equipment. Therefore,
!
installation should comply with all local codes.
!
!
!
!
!
!
APW Wyott takes pride in the design and quality of our products. When used as intended and with proper
care and maintenance, you will experience years of reliable operation from this equipment. To ensure best
results, it is important that you read and follow the instructions in this manual carefully.
Installation and start-up should be performed by a qualified installer who thoroughly read, understands and
follows these instruction.
If you have questions concerning the installation, operation, maintenance or service of this product, contact
APW Wyott Foodservice Equipment Company’s “ Technical Service Department”.
WARNING: SHOCK HAZARD - De-energize all power to equipment before cleaning the
!
equipment.
2
!
SAFETY PRECAUTIONS
Before installing and operating this equipment be sure everyone involved in its operation are fully trained
and are aware of all precautions. Accidents and problems can result by a failure to follow fundamental rules
and precautions.
The following words and symbols, found in this manual, alert you to hazards to the operator, service
personnel or the equipment. The words are defined as follows:
DANGER: This symbol warns of imminent hazard which will result in serious injury or death.
!
IMMEDIATELY INSPECT FOR SHIPPING DAMAGE
All containers should be examined for damage before and during unloading. The freight carrier has
assumed responsibility for its safe transit and delivery. If equipment is received damaged, either apparent or
concealed, a claim must be made with the delivering carrier.
A) Apparent damage or loss must be noted on the freight bill at the time of delivery. It must then be signed by
the carrier representative (Driver). If this is not done, the carrier may refuse the claim. The carrier can supply
the necessary forms.
B) Concealed damage or loss if not apparent until after equipment is uncrated, a request for inspection
must be made to the carrier within 15 days. The carrier should arrange an inspection. Be certain to hold all
contents and packaging material.
WARNING: This symbol refers to a potential hazard or unsafe practice, which could result in
!
serious injury or death.
CAUTION: This symbol refers to a potential hazard or unsafe practice, which may result in minor or
moderate injury or product or property damage.
!
NOTICE: This symbol refers to information that needs special attention or must be fully understood
even though not dangerous.
!
!
!
!
!
Installation and start-up should be performed by a qualified installer who thoroughly read, understands and
follows these instructions.
Location Of Data Plate:
The data plate is located on the back side of the front panel.
TABLE OF CONTENTS
Important Safety Instructions 2
Safety Precautions 3
Specifications & Dimensions 4
Installation 4
Operating Instructions 5
Cleaning/Maintenance 5
Service/Repair 6
Troubleshooting Guide 6
Wiring Diagrams 7
Parts Lists 8
MPC-1A 8
PC-1A 10
Warranty 12
3
SPECIFICATIONS AND DIMENSIONS
! Non jamming agitator motor gently turns to distribute kernels evenly over heated surface.
! Motor and controls located away from kettle heat in vented part of top cabinet.
! Produces a kettle of popcorn every 2 1/2 minutes.
! Popcorn kept hot by using heating element on the bottom and bulb heat on the top.
! Interiors are stainless steel.
! Cabinet constructed of stainless steel and tempered glass.
! Kettle made of heavy-gauge aluminum surrounded by stainless steel.
! Kettle is secured to cabinet through double-hung, stainless steel brackets.
MODEL
MPC-1A
MPC-1A
-1A
PC
-1A
PC
SIZE
-
6
-
6
-
8
10 oz
-
8
10 oz
8 oz
8 oz
VOLTS
120
240
120
240
WATTS
1125
1125
1643
1643
AMPS
9.4
4.7
13.7
6.8
DIMENSIONS
25 1/2"H x 19"W x 15 5/8" D
25 1/2"H x 19"W x 15 5/8" D
30"H x 22 1/4"W x 21 1/4" D
30"H x 22 1/4"W x 21 1/4" D
SHIP WT.
63#
63#
75#
75#
INSTALLATION
1. Always clean equipment thoroughly before first use. (See general cleaning instructions.)
2. Check rating label for your model designation and electrical rating.
3. Locate equipment on level counter and plug into a grounded outlet so the plug is accessible. (See
individual description for electrical loads.) On units bearing the CE marking, the appliance must be
connected by an earthing cable to all other units in the complete installation and, hence, to an
independent earth connection.
4. Install heat lamp in lamp holder at top rear of cabinet.
5. Slide drawer into slot at base of cabinet.
6. Install kettle by inserting locking hinge pin through holes in support bracket and kettle.
7. Insert kettle plug into ceiling mounted receptacle. Twist plug to lock.
8. Install kettle hinged covers by inserting tabs into support bracket slots. Cover with lifting knob must
be installed on operator side of kettle.
9. Install acrylic doors.
Cover
MPC-1A PC-1A
Lifting Arm
Latching Bracket
Stirrer Assy
Support Bracket
Kettle
Locking Hinge Pin
Latching Handle
Lifting Knob
Twistlock
Plug
Hinged Cover
4
Locking Hinge Pin
Support Bracket
Twistlock Plug
Kettle
Latching Handle