Wyott HR-20, HR-40 Operating Manual

Operating Manual
HR-20/HR-40 360° Hot Dog Grills
Manufactured by:
AMERICAN WYOTT CORPORATION
1938 Wyott Drive
Phone (307) 634-5801
Part No. 88989
Revised 1/88
TABLE OF CONTENTS
Introduction 3
Safety 3
Specifications 3
Wiring Diagram 4
Parts Identification 5
Exploded Views 8
Equipment Set Up 10
Operation 10
Cleaning Procedure 11
Nonscheduled Maintenance 11
Troubleshooting 11
Warranty 13
Page No
Introduction
The HOTROD has been designed for quiet efficient cooking of frankfurters and sausages in minimal space. The unique drive mechanism, which allows full tube rotation, ensures uniform cooking and has few moving parts. Independent front/rear temperature controls permit fast cooking and gentle warming at the same time. An optional sneeze guard is available.
Safety
If you know how to properly install, operate and maintain your Hotrod, you will increase your satisfaction with the unit as well as ensure safety. In accordance with generally accepted product safety labeling guidelines, the following four signal words are used throughout this manual to alert you to potential hazards and guide you to safe practices.
DANGER — The word "Danger" identifies a hazard which will cause severe personal injury, death, or considerable property damage if ignored.
WARNING — The word "Warning" identifies a hazard which can cause severe personal injury, death, or considerable property damage if ignored.
CAUTION — The word "Caution" identifies a hazard which will or can cause minor personal injury or property damage if ignored.
NOTE — The word "Note" is used to notify people of installation, operation, or maintenance information which is important but not hazard-related.
Specifications
Electrical —The required power supply for each model is shown below.
CAUTION: Operation of this unit on the incorrect supply voltage will damage the internal components and void the warranty.
P/N MODEL SUPPLY VOLTAGE POWER CONSUMED
5750-00, 5753-00, 5753-01 HR-20 120V, 60HZ. 10.8 amps
5751-00, 5754-00 HR-20 220V,60HZ. 5.5 amps 5752-00, 5755-00 HR-20 220V,50HZ. 5.5 amps 5756-00. 5759-00 HR-40 120V, 60HZ. 15.6 amps 5757-00. 5760-00 HR-40 220V,60HZ. 8.5 amps 5758-00, 5761-00 HR-40 220V,50HZ. 8.5 amps
5322-00, 5323-00, 5323-01 HR-40 120V, 60 HZ. 13.8 amps
WARNING: This unit should only be connected to a dedicated outlet, protected by a fuse or circuit breaker, which has been adequately and safely grounded to prevent the possibility of accidental shock.
Dimensions and Approximate Weights
MODEL PHYSICAL SIZE SHIPPING WEIGHT, LBS.
HR-20 19" x 17 1/4" x 7 1/8" 43
HR-40 19" x 30 1/4" x 7 1/8" 65
(length x width x height)
Wiring Diagram
The diagram below is shown with the power disconnected and the unit at room temperature.
The following table provides average DC resistances for Hotrod® motors and heating elements. This information is provided for service personnel and is not required for daily operation of the unit.
Item Motor Heating Element
Part Number 12120 12116 12117 5783 5788 5800 5801 5811
Resistance, ohms 19 91 137 131 85 440 285 96
Loading...