Wybron Coloram IT User Manual

Coloram IT
User Manual
84520 4-inch Coloram IT Color Changer 87110 7.5-inch Coloram IT Color Changer 810100 10-inch (2K) Coloram IT Color Changer
Coloram IT software version: V1.2 Manual issue date: October 16, 2006
CONTENTS
Declaration of Conformity .......................................... 3
Safety Information...................................................... 4
Introduction ................................................................ 5
InfoTrace System Overview....................................... 6
InfoTrace Connection Diagram .................................. 9
Quick Start ................................................................. 9
Using The Coloram IT Color Changer...................... 10
Coloram IT System Components............................. 11
Color Changer......................................................11
Gelstring...............................................................11
Power Supply.......................................................11
Cables..................................................................12
Coloram IT Menus ................................................... 15
Alerts/Error Messages..........................................17
DMX Address.......................................................19
Settings................................................................20
Sensor Info...........................................................21
Self Test (Demo)..................................................23
History..................................................................23
Reset Defaults.....................................................25
Head-Feet Restrictions ............................................ 26
Mounting and Installation Accessories..................... 27
Color Changer Mounting Plates............................... 27
Replacing a Gelstring............................................... 28
Equipment Compatibility .......................................... 30
RDM Equipment and InfoTrace................................ 30
Coloram IT Products and Standard Environments... 30
Specifications........................................................... 31
Parts list ................................................................... 31
Warranty Information ............................................... 33
ColorExpress IT Gelstrings ...................................... 34
Safety Notice
SAVE THESE INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
This manual gives step-by-step instructions for preparation, setup and operation of the Coloram IT Color Changer.
There is a potential risk of injury to persons if the product is not used as instructed.
The Coloram IT is not intended for residential use.
WARNING: When using electrical appliances, use basic precautions, including:
! Read this manual before connecting power. ! Use supervision around children. ! Do not touch moving parts. ! Only use attachments recommended or sold by Wybron. ! Use in a dry location only.
Replace only with same type and rating of fuse.
For questions, contact Wybron at 1-800-624-0146.
Product Modification Warning
Wybron, Inc. products are designed and manufactured to meet the requirements of United States and International Safety standards. Modifications to the products could affect safety and render the product non­compliant to relevant safety standards.
Introduction
The Coloram IT system includes a scrolling color changer and PS Power Supply, that uses Remote Device Management (RDM) bi-directional communications protocol, in a range of models and offers an ease of setup and use. The Coloram IT system is part of the InfoTrace system that represents a new way of managing a lighting installation.
The Coloram IT system, with its variable color capacity, RDM features and DMX compatibility affords the designer economy and versatility, particularly when budget and space are limited. The lightweight color changers slide easily into the gel frame holder of the light fixture. The compact power supplies attach effortlessly to the truss of the lighting rig or mount into a 19-inch rack.
The DMX512 control signal from the lighting console is connected through the InfoGate Gateway and dimmers to the PS Power Supply, and can continue on to additional PS Power Supplies or other DMX-controlled devices. The power supply sends power, DMX control signal and RDM information to the color changers on a single cable, eliminating the need for a separate power cable for the color changers.
Coloram IT color changers are 100% compatible with all members of the Coloram IT family including CXI IT color changers, PS Power Supplies, the Eclipse IT Dowser and Eclipse II IT Dowser. You can also daisy chain Coloram IT color changers with other Coloram IT equipment.
This manual gives step-by-step instructions for preparation, setup and operation of the Coloram IT Color Changer as part of the InfoTrace system.
Caution: The Coloram IT System is not compatible with Coloram II (RAM) System.
Do not connect Coloram IT Color Changers to Coloram II (RAM) Power Supplies.
Do not connect Coloram II color changers to PS Power Supplies.
Damage from such action will not be covered by the product warranties.
InfoTrace System Overview
Figure 1
The diagram above outlines the key components, which include:
InfoTrace The entire system is referred to as the InfoTrace System
InfoGate The software and hardware required to facilitate the transfer and
display of information
InfoChip A conversion chip that can be used with non-RDM equipment to
allow communication with the InfoGate Software
InfoStore – An Internet based application that aggregates data captured by
InfoGate and allows for the accumulation of historical information related to the equipment performance in the installation
IT Products Coloram IT, CXI IT, Eclipse IT, and Eclipse II IT all have updated
electronics to support RDM communication plus additional product improvements, including sensors to detect a variety of conditions.
The heart of the InfoTrace (IT) system is InfoGate — specialized software that uses the bi-directional communications protocol, Remote Device Management (RDM), to facilitate remote addressing and diagnostics for potentially every piece of equipment mounted on a rig. InfoGate works with all IT products and all RDM-compatible equipment from any manufacturer.
In addition, any non-RDM equipment can be upgraded with the installation of an InfoChip. Because InfoGate can work with any equipment, the setup, unit testing, and
troubleshooting for an entire rig can be coordinated from a single laptop.
Wybron's IT equipment (Coloram IT, CXI IT, Eclipse IT, and Eclipse II IT) is equipped with a series of sensors that can relay a wealth of information to InfoGate. These sensors can detect everything from light, voltage, current, to fan speed and even gelstring frame color information.
So while RDM equipment will allow identification and remote addressing, IT equipment can give more specific status information and warn of potential problems, possibly averting failures in the middle of a show. If the status of a device indicates any problem, InfoGate displays an alert with the nature of the problem and the exact location. Troubleshooting is now done in a fraction of the time.
InfoTrace provides the ability to:
• Automate the setup of DMX addresses – no more manual setting of DIP switches
• Proactively check the condition of equipment before, during and after a show
• Track lamp duty cycles to predict lamp failures before they happen
• Predict maintenance on equipment
• Predict gel replacement prior to degradation
Sensors
Coloram IT, CXI IT, Eclipse IT and Eclipse II IT:
• Aperture Light Sensor: Detects if the fixture's lamp is on.
• Voltage Sensor: Reports the head voltage level.
• Pass Through Current Sensor: Measures the amount of current that passes through the XLR connector wiring harness; assists in automatically setting up the rig in conjunction with InfoGate.
• Unit Current Sensor: Measures the amount of current that a unit is consuming, which can be an indicator of motor health.
• Timers: Keep track of how many hours the unit has been in operation in it’s lifetime and also since its last maintenance cycle.
• Fan RPM Sensor: RPM sensor on fan.
• Self Test Mode: Moves the gelstring without a DMX input command.
• Reverse Polarity Protection: Auto shutdown if scroller is plugged into a Coloram II power supply.
Additional Sensors
Coloram IT and CXI IT only:
• Gel Color Reader: Reads digital information off of the gelstring, including gelstring frame color information.
• Gel Wear Counter: Tracks how much the gelstring has moved and alerts the user when a gelstring needs to be replaced.
• Gel Temperature Sensor: Approximates and reports the temperature of the gel.
• "Gelstring is broken" Sensor: Detects if the gelstring is broken after gelstring initialization.
• Motor Shutdown if Gelstring is Broken: Automatically shuts down the motor if the gelstring breaks or comes loose from a roller.
Alert Warnings include:
• Fan Stopped
• High Motor Current
• Fan Off and Lamp On
• Unit Cleaning Period Reached
• Gelstring Initializaion Fail
• Low Voltage Alert
• Low Voltage Unit Shutdown
• Gelstring out of Position, Unit Shutdown (Coloram IT and CXI IT only)
• Gelstring Replacement Period Reached (Coloram IT and CXI IT only)
InfoTrace Connection Diagram
Figure 2
Quick Start
1. Connect the Equipment
A. Attach the Coloram IT Color Changer to a powered light fixture. B. Connect the Coloram IT Color Changer to the PS Power Supply using the
4-pin Wybron Power/Data Cable.
C. Connect the PS Power Supply to non-dimmed 100-240 VAC, 50/60Hz
power and to a DMX source.
D. Connect dimmers that have InfoChip installed, to the InfoGate hardware
and software. Please refer to the InfoGate and InfoChip manuals for details.
E. Using InfoGate:
i. Initiate “Perform Discovery” ii. In the DMX Map, drag and drop the DMX address for the color
changer to DMX address 1.
Please refer to the InfoGate manual for details.
2. Send DMX Levels
A. From the lighting console, vary the level of the Coloram IT on DMX address
1 to move the gelstring back and forth. Please refer to the InfoGate manual for details.
Using the Coloram IT Color Changer
The Coloram IT Color Changer sets its gelstring position according to the DMX512 level it receives from the control console. As all Coloram IT Color Changers will accommodate variable length gelstrings, the level settings which correspond with each frame position will vary depending on the number of frames in the gelstring.
The following chart shows the level settings that correspond with each frame position if a 24 frame gelstring is installed on a 7.5-inch color changer. The color of each frame position will be determined by your custom gelstring specification.
Channel
Level
Frame
Position
Channel
Level
Frame
Position
00
Frame 1
51
Frame 13
04
Frame 2
55
Frame 14
09
Frame 3
59
Frame 15
12
Frame 4
64
Frame 16
17
Frame 5
69
Frame 17
21
Frame 6
73
Frame 18
25
Frame 7
78
Frame 19
29
Frame 8
82
Frame 20
34
Frame 9
87
Frame 21
38
Frame 10
91
Frame 22
42
Frame 11
96
Frame 23
47
Frame 12
FL
Frame 24
If you send a channel level that is between the values shown, you can create split frame effects. For example, if you send a level of 49, the color changer positions the gelstring halfway between frame 12 and frame 13 creating a blend of the two colors.
Alternately, when the InfoGate information is exported to some types of lighting consoles, each gelstring frame position can be programmed as a gel color, frame number or other identifier. The desired gelstring frame is then recalled by selecting the desired gelstring frame (i.e. Frame 09) or gel color (R68) on the lighting console, instead of typing in a DMX level.
Coloram IT System Components
Color Changers
All Coloram IT Color Changers use gelstrings which can vary in length. The color changers set the position of the gelstring as determined by the DMX level. The color changers are powered by 24 volts DC which also comes from the power supply. The control signal, RDM data and DC power are all supplied in one cable connecting the color changers to the power supply.
Note: Please refer to the Specifications section of this manual for the maximum number of gelstring frames each color changer will hold.
Gelstring
The gelstring is a series of precisely cut, colored gel frames joined together, side by side, to create a sequence of colors. Two additional gels at each end of the gelstring are called the leader and the trailer. The leader and the trailer allow for proper attachment to the rollers. The gelstring has foil tags near each end which are necessary for the color changer's automatic calibration to the length of that particular gelstring.
Figure 3
The Coloram IT gelstring also has a radio frequency identification (RFID) tag which identifies the sequence of gels on the gelstring (as part of the InfoTrace setup process), and also assists in ordering additional gelstrings. Please refer to the ColorExpress IT section of this manual for information on how to create and order gelstrings online.
Power Supply
The PS Power Supply sends the DMX512 signal level from the lighting console to each color changer, along with 24 volts DC. RDM information is sent from the Coloram IT Color Changer to the InfoGate software installed on a Mac or PC.
Leade
Frame
Frame
Frame
Frame
Traile
Long foil
Short foil
RFID tag
Cables
Power/Data cable
The 4-pin Power/Data Cable connects the PS Power Supply outputs to the Coloram IT Color Changers and provides them with power and control signal.
The Power/Data cable uses 4-pin XLR connectors on either end and consists of two 14 AWG conductors and a 22 AWG twisted, shielded pair. The shells of the two XLR connectors are not electrically connected -- this prevents high power currents from flowing from chassis to chassis of the Coloram IT equipment. The twisted pair shield is connected only at the male XLR connector end. This is the standard Wybron Power/Data Cable.
XLR Pin # Wire Color Function Size
1 White Ground 14 AWG 2 Green Data - 22 AWG 3 Red Data + 22 AWG 4 Black 24 Volts DC 14 AWG
Note: The cable used in the Coloram IT System is the same cable which is used in the Coloram II and Forerunner Systems and may be referred to as Coloram IT, Coloram II or Forerunner cable.
DMX512 control cable
The DMX control cable from the lighting board to the InfoGate Gateway, dimmers and power supply is a five conductor cable with 5-pin XLR connectors on each end. The wiring pin out is specified by the USITT DMX512 / 1990 standard.
XLR Pin # Function
1 Common 2 Data ­3 Data + 4 Talkback ­5 Talkback +
Installing The Coloram IT
1. Attach the color changer to the fixture
Slide the color changer's mounting bracket into the gel frame holder of your fixture and lock the gel frame retention clip (if available). If the mounting plate installed on your color
changer does not fit the fixture, you may be able to replace it with the Wybron Universal Mounting plate.
The mounting plate allows you to position the color changer with the gelstring rolling either horizontally or vertically. However, Coloram IT operates most effectively with the fan, which is located in the top of the center panel, blowing air vertically (as hot air naturally rises).
2. Attach the safety cable
A safety cable is attached to the color changer. Run this cable around the pipe or truss from which you hang the light fixture and clip it to itself.
Figure 4
3. Mount the power supply
The PS Power Supply is designed to be free standing, truss mounted, or rack mounted. You decide which mounting method best suits your application.
The power supply comes with a mounting bracket which hooks over the pipe or truss of your lighting rig and is then locked into place with a thumb screw. If you have selected this mounting method, connect the safety cable by running it around the pipe or truss to which the power supply is attached.
The power supply can also be mounted into a 19" rack using the optional PS Power Supply rack mount kit. The rack mount kit will accommodate two PS Power Supplies side by side.
4. Connect the color changers to the power supply
Connect the color changers to the power supply using 4-pin Coloram IT cable.
Refer to the HEAD-FEET RESTRICTIONS section of this manual for details regarding the length of cable runs.
5. Connect the power supply to AC power
Plug the AC cord into a non-dimmed power circuit. The power supply automatically accommodates 100 - 240 VAC (50/60 Hz).
Power at the PS Power Supply is indicated by a red LED indicator.
The connected color changers will automatically "calibrate" themselves to the gelstring installed by doing the following actions:
a. Moving the gelstring toward the last frame, in search of the
long foil tag.
b. Turning around at the long foil tag and then searching for the
short foil tag at the beginning of the gelstring.
c. Stopping at the short foil tag and staying there if no DMX
signal is present or going to its commanded position if DMX signal is present.
Note: It may take up to 30 seconds before all color changers start to initialize.
Caution: Do not power the PS Power Supply from a dimmer. Severe damage will result and is not covered by product warranty.
6. Connect the DMX512 source
Connect the DMX512 signal source to the DMX input connector on the front of the power supply using standard DMX cable. Valid DMX signal will be indicated by a green LED. The color changers will now position their gelstrings according to their respective DMX signal levels.