WUNDER 960A, R150A, RG200A User Manual

WUNDER SA.BI.SRL EN USER MANUAL
960A R150A RG200 REV.10 15/01/2017 1
www.wunder.it
USER MANUAL
Read this manual carefully before using the instrument
INDEX
2.
GENERAL RULES………………………………………………………………………………………………………………………………..
PAGE 2
3.
SAFETY………………………………………………………………………………………………………………………………………………
PAGE 2
4.
TECHNICAL SPECIFICATION……………………………………………………………………………………………………………….
PAGE 3
5.
INSTRUCTION FOR USE …………………………………………………………………………………………………………………….
PAGE 3
6.
MAINTENANCE AND ASSISTANCE………………………………………………………………………………………………………
PAGE 5
7.
CONFORMITY……………………………………………………………………………………………………………………………………
PAGE 5
8.
IDENTIFICATION LABELS..........................................................................................................................
PAGE 5
9
SCRAPPING AND WASTE DISPOSAL …………………………………………………………………………………………………..
PAGE 6
10.
WARRANTY……………………………………………………………………………………………………………………………………….
PAGE 6
11.
ASSEMBLY-USE MECHANICAL TELESCOPIC HEIGHT METER (OPTIONAL)…………………………………………….
PAGE 7
By choosing the WUNDER mod. 960A or R150A or RG200A professional mechanical scale, you have purchased a high
precision instrument.
Since over 40 years WUNDER has placed its experience at the service of health. This instrument is compliant with
national standards in hospitals and clinics with medical class I with measurement function and is calibrated in
conformity with accuracy class IIII.
The instrument is characterized by the possibility of fixing the electronic terminal to the weighing platform by means of
a column or else installing the terminal autonomously.
WUNDER SA.BI.SRL EN USER MANUAL
960A R150A RG200 REV.10 15/01/2017 2
The instrument is equipped with a dual LCD electronic terminal with triple reading to simultaneously view Weight,
Height. and BMI
2. GENERAL RULES
Carefully read this manual before using the instrument as it supplies
important indications concerning OPERATING SAFETY AND MAINTENANCE.
The descriptions and illustrations supplied in this manual are not binding.
WUNDER reserves the right to modify its products as deemed convenient in order to approve them without being
committed to update this publication.
Conventions:
The following symbols have been used in this manual:
0476 EC TYPE APROVAL FOR MEDICAL USE
METROLOGICAL CERTIFICATION ACCURACY CLASS
ASSISTANCE WARRANTY CERTIFICATE
WARNING!
PLACED BEFORE DETERMINING PROCEDURES. COMPLIANCE FAILURE CAN HARM THE OPERATOR OR
PATIENT OR DAMAGE THE PRODUCT
3. SAFETY
WARNINGS!
Operators must read this manual carefully, comply with the instructions it contains and become familiar with the correct
use and maintenance procedures of the instrument.
Retain this manual for consultation and as a help in staff training
Do not overload the instrument beyond its maximum capacity
Do not apply loads abruptly.
Do not press the keys with sharp or pointed objects
Do not try to open the instrument.
Do not remove seals from the instrument.
Unplug the instrument before cleaning it
Do not place the instrument in water or other liquids
Perform maintenance and subsequent metric verifications regularly
WUNDER SA.BI.SRL EN USER MANUAL
960A R150A RG200 REV.10 15/01/2017 3
4. THECHNICAL SPECIFICATION
Model
960A
R150A
RG200A Capacity
150kg
150 kg
100-200kg
Division
1000g
1000 g
500-1000g
Height Rod 65-200cm- 2~6.6FT: ±1cm
Height Rod 60-200cm- 2~6.6FT : ±1cm Manifacture
WUNDER SA.BI.SRL Trezzo sull’Adda (MI)- Italy
MDD OIML
Class IIII
Unit weight
kg
Operation temperature
da +10°C a +40°C
5. INSTRUCTIONS FOR USE
960A
R150A column
RG200A column
The instrument is fully ready for use without accessories to assemble.
-Instructions manual
The instrument is fully ready for use without accessories to assemble. Possible accessories:
- Height rod 65-200cm;
- Wheels for transport.
- Instructions manual
The instrument is fully ready for use without accessories to assemble. Possible accessories:
-Telescopic height rod 60-200cm;
-Wheels for transport.
- Instructions manual.
960A Key
R150A Key
RG200A Key
1. Head with analog dial
2. Footboard covered with rubber
3. Base
4. Weight indicator
5. Zero adjusting screw
1. Head with analog dial
2. Footboard covered with rubber
3. Base
4. Weight indicator
5. Zero adjusting screw
6. Column
1. Head with analog dial
2. Footboard covered with rubber
3. Base
4. Weight indicator
5. Zero adjusting screw
6. Column
WUNDER SA.BI.SRL EN USER MANUAL
960A R150A RG200 REV.10 15/01/2017 4
ONLY WITH SUPPLY OF HEIGHT ROD
7. Height rod with support bracket (accessory)
8. Telescopic height rod (accessory).
9. Transport wheels kit (accessory on request) Note: the height measuring rod support bracket for the R150A model is already fixed on the column.
ONLY WITH SUPPLY OF HEIGHT ROD
7. Height rod with support bracket (accessory)
8. Telescopic height rod (accessory).
9. Transport wheels kit (accessory on request) Note: the height measuring rod support bracket for the RG200A model is already fixed on the column.
960A Preparing for use
R150A Preparing for use
RG200A Preparing for use
1.Overturn the instrument: remove the red clamp and loosen the red wing screw to unlock the lever mechanism
1.Overturn the instrument: remove the red clamp and loosen the red wing screw to unlock the lever mechanism
1.Overturn the instrument: remove the red clamp and loosen the red wing screw to unlock the lever mechanism
2. 960A
2. R150A
2. RG200A
2. Place the instrument on a flat surface for a reliable weight measurement.
WUNDER SA.BI.SRL EN USER MANUAL
960A R150A RG200 REV.10 15/01/2017 5
3
3
3
3. Make sure that the weight index (hand) is at zero. If it is not positioned correctly at zero manually act with the
adjusting screw located behind the device head.
4. Step onto the base (footboard) of the scale and read the weight indicated by the hand.
6. MAINTENANCE AND ASSISTANCE
For better and longer duration of the product it should receive thorough general cleaning periodically.
The instrument must be cleaned with a soft cloth moistened with water or neutral detergent, without using solvents or
abrasive substances. If the instrument remains idle for a long period, remove the batteries from the terminal.
During shipping, make sure not to subject the instrument to blows or excessive mechanical stress.
In case of repairs or assistance, contact your dealer or an authorised service centre contacting service@wunder.it or
wunder@wunder.it.
7. CONFORMITY
WUNDER MODEL 960A or R150A or RG200 MECHANICAL PROFESSIONAL SCALE SERIAL N°..............................................
We hereby certify that this instrument has been inspected and has successfully passed the functional test. It complies with the following standards and directives:
2009/23/CE; 93/42/
CE; EN45501
8 .IDENTIFICATION LABELS
WUNDER SA.BI.SRL EN USER MANUAL
960A R150A RG200 REV.10 15/01/2017 6
9. SCRAPPING AND WASTE DISPOSAL
1. Contact the competent authority for the waste weight disposal.
2. When you decide to no longer use this item, we recommend making it unusable. We also recommend making those
parts which could be sources of danger harmless
10. WARRANTY
This certificate must be kept until the warranty has expired.
It must be presented together with the invoice, tax receipt or delivery note providing the name of the dealer and date of
purchase whenever a technical intervention is required. Otherwise the user will lose any warranty rights.
The warranty takes effect from the date of purchase and is valid during the entire period foreseen by the current
catalogue/pricelist.
By warranty we mean the replacement or repair free of charge of parts making up the appliance which, at the discretion
of the manufacturer, are deemed faulty from the origin; Wunder therefore has the faculty of repairing or replacing the
item.
The warranty does not cover:
shipping faults, damage caused by falls, carelessness or tampering
damage caused by incapability of using the appliance and of its improper use
damage caused by an insufficient or inadequate electrical system or alterations resulting from environmental,
climatic or other types of conditions
damage due to incorrect installation of the appliance and repairs carried out by unauthorised personnel
Interventions at home for convenience controls or presumed defects
Routine maintenance and that which can be considered normal wear from use
consumables such as: power supplies, batteries, keyboards, plates, wheels, heads, rolls, load cells faulty due to blows or
overloads
Service can also be refused when the appliance has been changed or transformed in any way.
In case of interventions at one's home, the customer must pay the fixed fee; if however the appliance is repaired at an
authorised Wunder Service Centre, expenses and relative travel risk are borne by the user.
Wunder will not be held liable for damage of any nature caused directly or indirectly to persons, animals or objects
resulting from failure to comply with all the instructions indicated in this manual or anyway resulting from improper use.
The Court of Bergamo has jurisdiction in case of any dispute
WUNDER SA.BI.SRL EN USER MANUAL
960A R150A RG200 REV.10 15/01/2017 7
11. ASSEMBLING-USING THE HEIGHT ROD (OPTIONAL)
FOR THE R150A- RG200A MODEL
Using the mechanical telescopic height rod
WARNINGS!
TO MEASURE THE HEIGHT THE PATIENT MUST STEP ONTO THE SCALE FOOTBOARD
RG200A: manual telescopic height rod
Figure 1: in the packaging the height rod support is already assembled on the instrument. Simply secure the height rod with the
screw
Figure 1a-1b: secure the height measuring rod to the black abs support by tightening the screw in the height rod hole
Fig. 1
Fig. 1a
Fig. 1b
USING THE TELESCOPIC HEIGHT ROD
Measurements higher than 131 cm
Measurements lower than 130 cm
1
Raise the headrest lever
1
Lower the headrest lever
and press the central black
clamp
2
Position horizontally
2
While holding down the
black clamp, lower the
headrest lever
3
Lower the rod to where the
headrest lever
touches the patient's head.
The height can be read at point
"A"
3
Lower the rod to where the
headrest lever touches the
patient's head.
The height can be read at
point "B"
Loading...