wtw LS Flex/430 Operating Manual

Page 1
LabStation
LS Flex/430
Operating manual
ba75968edfs01 03/2012
Page 2
LabStation LS Flex/430
Copyright © Weilheim 2012, WTW GmbH
2
ba75968edfs01 03/2012
Page 3
LabStation LS Flex/430 Contents
Contents
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Battery operation with LabStation LS Flex/430. . . . . . . . . . . . . . 5
Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
ba75968e01 03/2012
3
Page 4
Overview LabStation LS Flex/430
LabStation

1Overview

With the LabStation, which is available as an accessory, you can con­veniently use your pHotoFlex in the laboratory. Laboratory operation with the LabStation enables the following addi­tional functions:
With photometric measurements, the zero measurement is retained
even after switching the pHotoFlex off and on again
You can connect a bar code reader for the simplified calling up of
programs
The LSdata software included serves to easily enter user-defined
programs
Operation with power pack and accumulator pack (included in the
scope of delivery of the LabStation). The accumulator pack in the pHotoFlex is automatically charged as soon as the meter is placed in the LabStation.
Fig. 1-1 LabStation
4
ba75968e01 03/2012
Page 5

LabStation LS Flex/430 Battery operation with LabStation LS Flex/430

1
2
3
2 Battery operation with LabStation
LS Flex/430
Battery operation The LabStation LS Flex/430 is supplied with power with the power pack
included. If the meter and the LabStation LS Flex/430 are connected to each other, the LabStation LS Flex/430 supplies the meter with power. At the same time, the accumulator pack (rechargeable batteries) in the meter is charged. The accumulator pack is charged even while the me­ter is switched off.
Charging time of the
accumulator pack
Inserting the
accumulator pack
approx. 36 hours.
CAUTION
Use original power packs only. The line voltage at the operating site must lie within the input volt­age range of the original power pack (
TA).
NOTE
The accumulator will eventually discharge even when the meter is switched off. If you do not work with the meter for a longer period of time you should charge the accumulator every 6 months to avoid total dis­charging. Accumulators that are often totally discharged have a shorter service life.
SEE chapter 3 TECHNICAL DA-
ba75968e01 03/2012
5
Page 6
Battery operation with LabStation LS Flex/430 LabStation LS Flex/430
5
4
3
2
1
1 Open the battery compartment:
– Unscrew the two screws (1) on the underside of the meter, – Remove the lid of the battery compartment (2).
2 If necessary, take four old batteries out of the battery compart-
ment.
3 Connect the cable of the accumulator pack with the socket (3)
on the bottom of the battery compartment and insert the accu­mulator pack in the battery compartment.
4 Close the battery compartment and fix it with the screws.
Connecting the
LabStation LS Flex/430
1 If necessary, replace the Euro plug (1) on the power pack (2)
by the country-specific plug suitable for your country.
2 Connect the plug (3) to the socket (4) of the LabStation.
3 Connect a PC, printer or bar code reader to the socket (5) of
the LabStation as necessary.
When the pHotoFlex LabStation LS Flex/430 Station, a bar code reader can be connected. A bar code reader en­ables to select program numbers in a simplified manner.
6
Recommended bar code readers (see operating manual of your pHo­toFlex). For the interface of your meter, set the same baud rate that is set for
is operated in the Lab-
ba75968e01 03/2012
Page 7
LabStation LS Flex/430 Battery operation with LabStation LS Flex/430
LabStation
the bar code reader (see operating manual of your pHotoFlex). The baud rate of the bar code reader is given in the operating manual of the bar code reader.
4 Connect the power pack to an easily accessible power socket.
5 Insert the pHotoFlex in the LabStation LS Flex/430.
ba75968e01 03/2012
7
Page 8
Technical data LabStation LS Flex/430

3 Technical data

Dimensions approx. 236 x 82 x 170 mm
Weight approx. 0.6 kg
Power
supply
Serial
interface
Applicable directives
and standards
Power pack FRIWO FW7555M/09, 15.1432.500-00
Friwo Part. No. 1883259 Input: 100 ... 240 V ~ / 50 ... 60 Hz / 400 mA Output: 9 V = / 1.5 A Connection max. overvoltage category II
Primary plugs contained in the scope of de­livery: Euro, US, UK and Australian.
Connection of the null modem cable (included in the scope of delivery) Baud rate Adjustable:
1200, 2400, 4800, 9600, 19200 Baud Type RS232 Data bits 8 Stop bits 2 Parity None Handshake RTS/CTS Cable length Max. 15 m
EMC EC directive 89/336/EEC
EN 61326-1/A3:2003
FCC Class A Meter safety EEC directive 73/23/EEC
EN 61010-1 :2001
UL3101-1
CAN/CSA-C22.2 No. 1010.1-92 Climatic class VDI/VDE 3540 IP protection class EN 60529:1991
8
ba75968e01 03/2012
Page 9
Page 10
What can Xylem do for you?
We're a global team unified in a common purpose: creating innovative solutions to meet our world's water needs. Developing new technologies that will improve the way water is used, conserved, and re-used in the future is central to our work. We move, treat, analyze, and return water to the environment, and we help people use water efficiently, in their homes, buildings, factories and farms. In more than 150 countries, we have strong, long-standing relationships with customers who know us for our powerful combination of leading product brands and applications expertise, backed by a legacy of innovation.
Xylem Analytics Germany GmbH Dr.-Karl-Slevogt-Str. 1 82362 Weilheim Germany
Xylem Analytics Germany Sales GmbH & Co. KG WTW Dr.-Karl-Slevogt-Str. 1 82362 Weilheim Germany
Tel.: Fax: E-Mail
Internet:
+49 881 183-325 +49 881 183-414 wtw.rma@xyleminc.com
www.WTW.com
Service address:
®
For more information on how Xylem can help you, go to xyleminc.com.
Loading...