SAFETY DATA SHEET ATTAX HEAVY-DUTY DEGREASER
drains. Contain and clean-up the spill. Observe all personal protection equipment
recommendations. Ensure personal protection during removal of spillages.
Eliminate all ignition sources if safe to do so. Local authority should be advised if
significant spill cannot be contained.
For emergency responders: Use personnel protection recommended in Section 8
6.2
Environmental precautions: Prevent further leakage or spillage if safe to do so.
Avoid discharge into drains, water courses or onto the ground
6.3
Methods and material for containment and cleaning up
Do not release large quantities into the surface water or into drains.
Wear suitable gloves and eye/face protection.
Remove or make safe all sources of ignition. Rinse remaining liquid with water
6.4
Reference to other sections See Also Section 7, 8, 13.
6.5
Additional Information: For waste Disposal: Follow local regulations for discharge of waste
effluent.
7.1
Precautions for safe handling Use only in well-ventilated areas if significant misting will occur.
If irritation develops in nose or throat leave the area and ventilate area prior to re-entry. Keep
away from oxidizing, reducing agents. Keep away from fire, sparks and heated surfaces - no
smoking.
7.2
Conditions for safe storage, including any incompatibilities Store in a cool, dry, well-
ventilated place. Do not use or store near heat or open flame. Do not store and transport with
oxidizers etc. Keep container closed when not in use. Storage Temperature < 50 ºC.
7.3
Incompatible materials: Oxidizing agents, Strong Acids
7.4
Additional Information: When product is used in confined space, the use of proper ventilation
is required.
8.1
Control parameters
8.1.1
Occupational Exposure Limits:
US. Workplace Environmental Exposure Level (WEEL) Guides
D-limonene (CAS 5989-27-5) TWA 165.5 mg/m3
8.1.2
Biological limit value: Biological limit values are not available for this product.
8.2
Engineering Controls: provide good ventilations. Ensure that eyewash stations and
safety showers are proximal to the work-station location.
8.3
Personal protection equipment (PPE)
Protective Handwear: Nitrile gloves recommended preventing drying of hands.
Protective Eyewear: Safety glasses with side shields or goggles
Other protective clothing: Not required.
Respiratory Apparatus: None required, however if applicable results in
significant misting of product respiratory
protection is recommended. If needed, use a
MSHA/NIOSH approved half mask air purifying
respirator with carbon filters.