Worldwide Electric Corporation IROW50-12-404T Data Sheet

HORSEPOWER RPM / POLES VOLTAGE / PHASE FRAME ENCLOSURE / DEGREE OF PROTECTION FREQUENCY FULL LOAD SPEED SERVICE FACTOR INSULATION CLASS FULL LOAD AMPS; 230 / 460 / 796 LOCKED ROTOR AMPS (STARTING); 230 / 460 / 796 NO LOAD CURRENT NEMA CODE LETTER
LOAD EFF. P.F.
100% 89.9% 0.85 75% 90.6% 0.80 50% 90.4% 0.69
DUTY CYCLE
FULL LOAD LRT BDT
232.3 lb.ft. 309% 365%
SLIP NEMA DESIGN MOMENT OF INERTIA MAX. TIME LOCKED ROTOR (Hot) MAX. AMBIENT TEMPERATURE MAX. ELEVATION TEMPERATURE RISE (At Full Load) DE BEARING ODE BEARING REGREASING INT. - DE BEARING REGREASING INT. - ODE BEARING GREASE TYPE MOUNTING ROTATION SHAFT MATERIAL CONNECTION DIAGRAM APPROXIMATE WEIGHT INVERTER RATING
F1 (F2 Suitable)
Bi-Directional
1045 Carbon Steel
230 / 460 V - 12 Lead Δ
995 lbs.
10:1 CT / 20:1 VT PWM Type
80° C
NU317
6313C3
5,000 Hours
7,000 Hours
Mobil Polyrex EM
5.64%
D
30.65 lb.ft.
2
20 Seconds
40° C
3300 Ft. Above Sea Level
736 / 368 / 212 A
52.0 / 26.0 / 15.0 A
G
EFFICIENCY / POWER FACTOR
CONTINUOUS
TORQUE
TEFC / IP54
60 HZ Suitable For 50 HZ Operation With 1.0 SF
1130 RPM
1.15F123 / 61.5 / 35.5 A
WORLDWIDE ELECTRIC MOTOR DATA SHEET
IROW50-12-404T
50
1200 / 6
230 / 460 / 796 V / 3
404T
REVISED - 09/04/13
Loading...