Worldwide Electric Corporation HT400-9-5811RB Data Sheet

AC INDUCTION MOTOR DATA SHEET
Model No. or RFQ No. HT400-9-5811RB Item No. Rev. No.
Project Name Project No. Quantity
GENERAL SPECIFICATION PERFORMANCE DATA
Frame Size 5811 Rated Output 400 HP
Type HLE5 5811 Number of Poles 8
Method Of Cooling IC411 Starting Method * D.O.L.
Rated Frequency 60 Hz Rated Voltage 4160 V 2300 V
Number Of Phases 3
Insulation Class F
Temp. Rise At Full Load (By Resistance Method) Efficiency
At 1.0 S.F. 80°C 50% Load 93.1 %
Motor Location Indoor 75% Load 94.0 %
Altitude Less Than 1000 Meters 100% Load 94.1 %
Relative Humidity Less Than 90% Power Factor (p.u.)
Ambient Temp. 40°C (Max.) 50% Load 0.60
Duty Type Continuous (S1) 75% Load 0.72
Service Factor 1.15 100% Load 0.77
Mounting B3, Horizontal Speed at Full Load 891 RPM
Type Anti-Friction Torque
Bearing
DE/N-DE NU324M / 6322C3 Full Load 2359 LB-FT
Lubricant Grease (Multemp SRL)
External Thrust Not Applicable
Coupling Method V Belt GD
Shaft Extension Single Load
Terminal
Box
Main Steel Motor
Aux. Yes Sound Pressure Level (No-load & Mean Value At 1m From Motor)
Location Refer To Outline Drawing 85 dB(A)
Application --- Vibration 2.4 mm/sec (peak)
Area Classification Non-Hazardous, Non-Seismic
Type Of Ex-Protection Not Applicable Hot 1 time
Applicable Standard IEEE, NEMA Paint Munsell No. 7.5BG6/1.5
ACCESSORIES
1. Winding Temp. Detector (Pt 100 ) : 2 EA / Phase Outline Dimension Drawing / Motor Weight (Approx.)
2. Space Heater : 120V, 180W, 1 Phase HT400-9-5811RB 6590 lbs.
SPARE PARTS REMARK
Date DSND CHKD CHKD APPD
Note: Others not mentioned in this data sheet shall be in accordance with maker standard.
Above technical data are only design values and shall be guaranteed with tolerance of applicable standard. Inspection and performance test shall be maker standard, if not mentioned. * In case of Inverter-Fed Motor, performance data is based on sine wave tests.
** The data are based on rated voltage & frequency, and data are expressed as a percentage of full load value.
HHI W230-131-1 A4(210MM x 297MM)
Current
2
Permissible Number Of Consecutive Starts
07-29-10 M.H.KIM S.C.HWANG
Full Load 57.2 A 102.2 A
Locked-Rotor**
Locked-Rotor**
Breakdown**
SUBMITTAL DRAWING
550% 500%
90 % 80 %
200 % 210 %
Cold 2 times
J.W.LIM
NOTE This motor is designed to be operated
only in the direction of the arrow.
THREE PHASE INDUCTION CAGE ROTOR MOTOR (TEFC)
TYPE FRAME NO. OUTPUT POLES VOLTAGE FREQUENCY MOUNTING WEIGHT
BEARING NO.
D.E. N-D.E.
HLE5 5811 5811 400 HP 8 P 4160 V / 2300 V 60 Hz B3 6590 lbs. NU324M 6322C3
NOTE Permissible Cantilever Force : 20048N
(The center of belt pulley is on the end of shaft extension part.)
DISTRIBUTED IN THE UNITED STATES BY:
WORLDWIDE ELECTRIC CORPORATION ROCHESTER, NEW YORK
HT400-9-5811RB
Loading...