HORSEPOWER
RPM / POLES
VOLTAGE / PHASE
FRAME
ENCLOSURE / DEGREE OF PROTECTION
FREQUENCY
FULL LOAD SPEED
SERVICE FACTOR
INSULATION CLASS
FULL LOAD AMPS; 230 / 460
LOCKED ROTOR AMPS (STARTING); 230 / 460
NO LOAD CURRENT
NEMA CODE LETTER
LOAD EFF. P.F.
100% 89.5% 0.76
75% 89.3% 0.71
50% 84.1% 0.62
DUTY CYCLE
FULL LOAD LRT BDT
22.26 lb.ft. 220% 300%
SLIP
NEMA DESIGN
MOMENT OF INERTIA
NUMBER OF STARTS (Hot / Cold)
MAX. AMBIENT TEMPERATURE
MAX. ELEVATION
TEMPERATURE RISE (At Full Load)
DE BEARING
ODE BEARING
GREASE TYPE
MOUNTING
ROTATION
APPROXIMATE WEIGHT
AREA CLASSIFICATION
INVERTER RATING
SPECIFICATION - In Accordance With
WORLDWIDE ELECTRIC MOTOR DATA SHEET
EP5-12-215TC
Class I, Division 2, Groups A, B, C, D
10:1 CT / 20:1 VT PWM Type
40° C at 1.25 SF / 55° C at 1.0 SF
EFFICIENCY / POWER FACTOR
60 HZ Suitable For 50 HZ Operation With 1.0 SF
1.25 SF at 40° C / 1.0 SF at 55° C
215TC
MARCH 10, 2015
E 2F1 2F2 H BA A B C D G J P L AB AH BC
4.25 5.5 7 0.41 3.5 10.51 9 20.5 5.25 0.78 2.36 10.75 12.26 8.63 3.12 0.25
KEYSET
S ES R AK AJ BF BB BD N-W U AA XB XC XD XE
0.312 2.41 1.201 8.5 7.25 1/2-13 0.25 8.99 3.38 1.375 1 2.95 5 4.57 7.48
WORLDWIDE ELECTRIC MOTOR DRAWING