Worldwide Electric Corporation EP100-18-405T Data Sheet

HORSEPOWER RPM / POLES VOLTAGE / PHASE FRAME ENCLOSURE / DEGREE OF PROTECTION FREQUENCY FULL LOAD SPEED SERVICE FACTOR INSULATION CLASS FULL LOAD AMPS; 230 / 460 LOCKED ROTOR AMPS (STARTING); 230 / 460 NO LOAD CURRENT NEMA CODE LETTER
LOAD EFF. P.F.
100% 95.4% 0.86 75% 95.2% 0.82 50% 94.7% 0.72
DUTY CYCLE
FULL LOAD LRT BDT
293.2 lb.ft. 220% 240%
SLIP NEMA DESIGN MOMENT OF INERTIA NUMBER OF STARTS (Hot / Cold) MAX. AMBIENT TEMPERATURE MAX. ELEVATION TEMPERATURE RISE (At Full Load) DE BEARING ODE BEARING GREASE TYPE MOUNTING ROTATION APPROXIMATE WEIGHT AREA CLASSIFICATION TEMPERATURE CODE AT 40°C AMBIENT TEMPERATURE CODE AT 55°C AMBIENT INVERTER RATING SPECIFICATION - In Accordance With
WORLDWIDE ELECTRIC MOTOR DATA SHEET
EP100-18-405T
100
1800 / 4
230 / 460 V / 3
405T
TEFC / IP55
60 HZ Suitable For 50 HZ Operation With 1.0 SF
1790 RPM
1.25 SF at 40° C / 1.0 SF at 55° C
F
228.6 / 114.3 A
1450 / 725 A
75.0 / 37.5 A
G
EFFICIENCY / POWER FACTOR
S1 / Continuous
TORQUE
0.56%
B
45.5 lb.ft.
2
2 Hot / 3 Cold
40° C at 1.25 SF / 55° C at 1.0 SF
3300 Ft. Above Sea Level
80° C
NU316
6313
Mobil Polyrex EM
F1 (F2 Suitable)
Bi-Directional
T3A
T3
1198 lbs.
Class I, Division 2, Groups A, B, C, D
10:1 CT / 20:1 VT PWM Type
NEMA, CSA
JUNE 23, 2016
E 2F1 2F2 H BA A B C D G J P L AB
8 12.25 13.75 0.81 6.62 19.29 17.8 38.3 10 1.18 3.15 21.73 23.62 18.11
AA XB XC XD XE
3 4.57 11.73 9.76 12.48
U
WORLDWIDE ELECTRIC MOTOR DRAWING
EP-405T
DIMENSIONS - INCHES
MOUNTING
KEYSET
SHAFT
TERMINAL BOX
2.45
7.25
2.875
KEY
S
0.75ES5.65
R
N-W
REVISED - 12/07/15
EP 100 4
Motor Performance Curves
EPIC Output rating (HP) 100 1790 Full Load Torque : 293 lb.ft
LRT (% FLT): 220
460 volt FLA: 114.3
Rotor Wk^2: 45.5 lb-ft^2
BDT (% FLT): 240
230 volt FLA: 228.6
Motor type:
FL Speed:
Torque at rated voltage
Torque @ 80% voltage
Current at rated voltage
Current at 80% voltage
0
100
200
300
400
500
600
700
0
50
100
150
200
250
0 10 20 30 40 50 60 70 80 90 100
CURRENT IN %
TORQUE IN %
SPEED IN %
SPEED VS TORQUE & CURRENT CURVE
EFF.
P.F
CURRENT
0
20
40
60
80
100
120
140
160
180
200
0
10
20
30
40
50
60
70
80
90
100
0 25 50 75 100 125
Amps
EFF. & P.F IN %
LOAD IN %
OUTPUT VS EFF., P.F & CURRENT CURVE
6/6/2017
WorldWide Electric Corp
800-808-2131
worldwideelectric.net
Loading...