HORSEPOWER
RPM / POLES
VOLTAGE / PHASE
FRAME
ENCLOSURE / DEGREE OF PROTECTION
FREQUENCY
FULL LOAD SPEED
SERVICE FACTOR
INSULATION CLASS
FULL LOAD AMPS; 230 / 460
LOCKED ROTOR AMPS (STARTING); 230 / 460
NO LOAD CURRENT
NEMA CODE LETTER
LOAD EFF. P.F.
100% 95.4% 0.86
75% 95.2% 0.82
50% 94.7% 0.72
DUTY CYCLE
FULL LOAD LRT BDT
293.2 lb.ft. 220% 240%
SLIP
NEMA DESIGN
MOMENT OF INERTIA
NUMBER OF STARTS (Hot / Cold)
MAX. AMBIENT TEMPERATURE
MAX. ELEVATION
TEMPERATURE RISE (At Full Load)
DE BEARING
ODE BEARING
GREASE TYPE
MOUNTING
ROTATION
APPROXIMATE WEIGHT
AREA CLASSIFICATION
TEMPERATURE CODE AT 40°C AMBIENT
TEMPERATURE CODE AT 55°C AMBIENT
INVERTER RATING
SPECIFICATION - In Accordance With
WORLDWIDE ELECTRIC MOTOR DATA SHEET
60 HZ Suitable For 50 HZ Operation With 1.0 SF
1.25 SF at 40° C / 1.0 SF at 55° C
EFFICIENCY / POWER FACTOR
40° C at 1.25 SF / 55° C at 1.0 SF
Class I, Division 2, Groups A, B, C, D
10:1 CT / 20:1 VT PWM Type

E 2F1 2F2 H BA A B C D G J P L AB
8 12.25 13.75 0.81 6.62 19.29 17.8 38.3 10 1.18 3.15 21.73 23.62 18.11
AA XB XC XD XE
3 4.57 11.73 9.76 12.48
WORLDWIDE ELECTRIC MOTOR DRAWING

EPIC
Output rating (HP) 100 1790
Full Load Torque : 293 lb.ft
LRT (% FLT): 220
460 volt FLA: 114.3
Rotor Wk^2: 45.5 lb-ft^2
BDT (% FLT): 240
230 volt FLA: 228.6
Torque at rated voltage
Torque @ 80% voltage
Current at rated voltage
0
100
200
300
400
500
600
700
0
50
100
150
200
250
0 10 20 30 40 50 60 70 80 90 100
CURRENT IN %
TORQUE IN %
SPEED IN %
SPEED VS TORQUE & CURRENT CURVE
EFF.
P.F
CURRENT
0
20
40
60
80
100
120
140
160
180
200
0
10
20
30
40
50
60
70
80
90
100
0 25 50 75 100 125
Amps
EFF. & P.F IN %
LOAD IN %
OUTPUT VS EFF., P.F & CURRENT CURVE
WorldWide Electric Corp
800-808-2131