THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL GAS
EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD START-UP AND
ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL.
POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN THE
EVENT THE SMELL OF GAS IS DETECTED. THIS INFORMATION CAN BE OBTAINED
FROM THE LOCAL GAS SUPPLIER.
IMPORTANT
In the event a gas odor is detected, shut
down units at main shutoff valve and
contact the local gas supplier for service.
FOR YOUR SAFETY
Do not store or use gasoline or other
flammable vapors or liquids in the vicinity of
this or any other appliance.
Improper installation, adjustment, alteration,
service or maintenance can cause property
damage, injury or death. Read the
installation, operating and maintenance
instructions thoroughly before installing or
servicing this equipment.
IN THE EVENT OF A POWER FAILURE, DO NOT
ATTEMPT TO OPERATE THIS DEVICE.
- 2 -
INSTALLATION, OPERATION AND CARE OF
CHALLENGER XL SERIES GAS RESTAURANT RANGES
PLEASE KEEP THIS MANUAL FOR FUTURE USE
GENERAL
Wolf ranges and ovens are produced with quality workmanship and material. These ranges are
designed with efficiency in cooking performance, sanitation and ease of cleaning ability in mind. Proper
installation, usage and maintenance of your range will result in many years of satisfactory performance.
The manufacturer suggests that you thoroughly read this entire manual and carefully follow all of the
instructions provided.
OPTIONAL FIELD INSTALLABLE ACCESSORIES
DESCRIPTION
Flue Devices
Flex Hose and Quick
Disconnect
Oven Racks
Casters
ACCESSORIES
- 23" (584 mm) high stainless steel backsplash with broiler mounting brackets
- 1 extra rack with standard and convection ovens.
- 1 extra pair of rack slides with standard ovens.
- Set of four 6" (152 mm) casters.
- Set of six 6" (152 mm) casters.
INSTALLATION
UNPACKING
This range was inspected before leaving the factory. The transportation company assumes full
responsibility for safe delivery upon acceptance of the shipment. Immediately after unpacking, check for
possible shipping damage. If the range is found to be damaged, save the packaging material and
contact the carrier within 15 days of delivery.
Carefully unpack range(s) and place in the approximate installation position. Remove parts (packed in a
cardboard box) from oven cavity.
If burner has been shipped using any package strapping devices, remove these before installing the
range.
Before installing, check the type of gas supply (natural or propane) to make sure they agree with the
specifications on the rating plate located on the inside of the kick panel. If the supply and equipment
requirements do not agree, do not proceed with the installation. Contact your dealer immediately.
- 3 -
LOCATION
The equipment area must be kept free and clear of combustible substances.
CONSTRUCTION
Back: 6" (152 mm) 0"
Right Side: 10" (254 mm) 0"
Left Side: 10" (254 mm) 0"
The installation location must allow adequate clearances for servicing and proper operation. A minimum
front clearance of 35" (889 mm) is required.
The ranges are suitable for installation on combustible floors when 6" (152 mm) adjustable legs or
casters are used. When legs or casters are removed, use only on noncombustible floors, curb, or
platform, with front appliance base projecting 3" (76 mm) beyond curb or platform.
The range(s) must be installed so that the flow of combustion and ventilation air will not be obstructed.
Adequate clearance for air openings into the combustion chamber(s) must be provided. Make sure
there is an adequate supply of air in the room to allow for combustion of the gas at the burners.
INSTALLATION CODES AND STANDARDS
Your Wolf Range must be installed in accordance with:
In the United States of America:
1. State and local codes.
2. National Fuel Gas Code, ANSI-Z223.1/NFPA #54 (latest edition). This shall include but
not be limited to: NFPA #54 Section 10.3.5.2 for Venting. Copies may be obtained
from The American Gas Association Accredited Standards Committee Z223, @ 400 N.
Capital St. NW, Washington, DC 20001 or the Secretary Standards Council, NFPA, 1
Batterymarch Park Quincy, MA 02169-7471.
NOTE: In the Commonwealth of Massachusetts
All gas appliances vented through a ventilation hood or exhaust system equipped with
a damper or with a power means of exhaust shall comply with 248 CMR.
3. NFPA Standard # 96 Vapor Removal from Cooking Equipment, latest edition, available
from the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.
In Canada:
1. Local codes.
2. CAN/CSA-B149.1 Natural Gas Installation (latest edition)
3. CAN/CSA-B149.2 Propane Installation Code (latest edition), available from the
Canadian Gas Association, 178 Rexdale Blvd., Etobicoke, Ontario, Canada M9W 1R3
The above are available from the Canadian Standard Association, 5060 Spectrum Way, Suite 100,
Mississauga, Ontario, Canada L4W 5N6.
- 4 -
LEG/CASTER ASSEMBLY
The range is shipped fully assembled, except for the legs. The range is provided with 6"(152 mm)
adjustable stainless steel legs (hardware included), packaged in a box located inside of the oven. A set
of 6"(152 mm) casters are available as an optional field installable accessory.
RANGE SERIES LEGS TO INSTALL CASTERS TO INSTALL
C24 4 4
C36 4 4
C48 6 6
C60 6 6
C72 6 6
Installation of Legs/Casters:
1. Carefully tip range on its side.
2. Align holes in leg/caster mounting plate with pre-drilled holes in bottom of range located in each of
the four corners. Two additional legs/casters must be installed on the C48, C60, and C72. The
additional legs/casters should be installed utilizing the pre-drilled holes shown in Figure 1.
Figure 1 - Cross Chassis Leg/Caster Mounting
3. Attach mounting plate to bottom of range using four ¼ - 20 x ⅝“ self tapping screws (provided). If
casters are being installed, the locking casters should be mounted on the front.
4. After all legs/casters have been installed, carefully return the range to its upright position.
(For additional leg information, see Leveling section of this manual).
Ranges mounted on casters must use a flexible connector (not supplied by Wolf) that complies with the
Standard for Connectors for Movable Gas Appliances, ANSI Z21.69•CSA 6.16 and a quick-disconnect
device that complies with the Standard for Quick-Disconnect Devices for Use With Gas Fuel, ANSI
Z21.41•CSA 6.9. In addition, adequate means must be provided to limit movement of the appliance
without depending on the connector and the quick-disconnect device or its associated piping to limit
appliance movement. Attach the restraining device at the rear of the range.
- 5 -
If disconnection of the restraint is necessary, turn off the gas supply before disconnection. Reconnect
this restraint prior to turning the gas supply on and returning the range to its installation position.
If the range is installed on casters and is moved for any reason, it is recommended that the range be
re-leveled front to back and side to side for even baking.
LEVELING
To level the range, place a carpenter's level on the range top and check leveling of the unit side to side
and front to rear. Achieve leveling by turning each foot section of the unit's leg as needed. Turning the
foot in a counter clockwise direction will increase height and clockwise will decrease.
GAS PRESSURE REGULATOR
A preset gas pressure regulator and street elbow is shipped with the range. This regulator must be
installed by an authorized service person before the unit is placed into operation. See full unit data plate
located on the rear of the range, or the secondary data plate, riveted to the kick panel, for pressure
regulator setting information. If a manometer is being used, utilizing one of the available pressure taps
in the manifold, the manifold pressure with one burner on should be ± 0.3" W.C. of the value indicated
on the rating plate.
1. Locate the gas connection pipe protruding through the back of the unit.
2. Cover the pipe threads with pipe joint compound resistant to propane gases.
3. Screw the regulator onto the pipe hand tight with flow direction arrow pointing towards the back of
the unit and the regulator adjustment in the up right position.
4. With a pipe wrench, tighten the regulator securely in the upright position. (The regulator is preset
and should not require any additional adjustments.) The pressure regulator must be mounted
horizontally to ensure the proper preset outlet pressure. If mounted in any other direction, the outlet
pressure must be rechecked and possibly reset. A leak limiter is supplied with every regulator to
allow excess gas pressure to escape. Do not obstruct the limiter or the gas regulator, as obstruction
may cause the regulator to malfunction.
GAS CONNECTIONS
All gas supply connections and any pipe joint compound used must be resistant to the action
of propane gases.
Prior to lighting, check all joints in the gas supply line for leaks. Use soap and
water solution. Do not use an open flame.
After piping has been checked for leaks, all piping receiving gas should be fully purged to remove air.
TESTING THE GAS SUPPLY SYSTEM
When test pressures exceed ½ psig (3.45 kPa), the range and its individual shutoff valve must be
disconnected from the gas supply piping system.
When test pressures are ½ psig (3.45 kPa) or less, the range must be isolated from the gas supply
system by closing its individual manual shutoff valve.
- 6 -
FLUE CONNECTIONS
DO NOT obstruct the flow of flue gases from the flue located on the rear of the range. Proper venting
of flue gas is vital to the safe and efficient operation of the range. Problems arising from the intentional
obstruction of the flue will result in voiding of warranty. It is recommended that the flue gases be
ventilated to the outside of the building through a ventilation system installed by qualified personnel.
From the termination of the flue to the filters of the hood venting system, a minimum clearance of 18"
(457 mm) must be maintained. Information on the construction and installation of ventilating hoods
may be obtained from the standard for "Vapor Removal from Cooking Equipment," NFPA No. 96 (latest
edition), available from the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.
ELECTRICAL CONNECTIONS
Electrical and grounding connections must comply with the applicable portions
of the National Electrical Code and/or other local electrical codes.
Disconnect the electrical power to the machine and follow Lockout / Tagout
procedures.
Appliances equipped with a flexible electrical supply cord are provided with a
three-prong grounding plug. It is imperative that this plug be connected into a properly
grounded three-prong receptacle. If the receptacle is not the proper grounding type, contact an
electrician. Do not remove the grounding prong from this plug.
The convection range is designed for 120 volt power supply and is provided with a flexible electric
supply cord and plug that must be plugged into the proper receptacle. Do not connect the convection
range to electrical supply until after gas connections have been made. The wiring diagram for the
convection range is located on the rear of the appliance.
OPERATION
The appliance and its parts are hot. Use care when operating, cleaning, or
servicing the appliance.
CONTROLS
Open Top Burner Valve — Allows gas to flow to the top burners. To open valve, turn knob
counterclockwise. To close valve, turn knob clockwise.
Manual Griddle Valve — Allows gas to flow to the griddle burners. To open valve, turn knob
counterclockwise. To close valve, turn knob clockwise.
Oven Thermostat — Regulates oven temperature. The thermostat temperature range is from LOW at
approximately 250°F (121°C) to HI at approximately 500°F (260°C). Turn the thermostat
counterclockwise to increase temperature and clockwise to decrease temperature. Oven temperature
regulation is the most accurate between 300°F (149°C) and 500°F (260°C).
- 7 -
Griddle Thermostat — Regulates griddle temperature. The thermostat temperature range is from
LOW at approximately 200°F (93°C) to HI at approximately 550°F (288°C). Turn the thermostat
clockwise to increase temperature and counterclockwise to decrease temperature.
Safety Valve – Monitors standing pilot. The oven and thermostatic griddle feature a standing pilot that
must be manually lit. The pilot is monitored by a thermocouple and pilot safety valve. If the pilot goes
out, the safety valve will shut-off the gas supply to the pilot and main burners.
Fan Switch – Turns fan on and off (Convection Ovens only). Fan turns on when door is closed. Fan
turns off when door is opened.
BEFORE FIRST USE
Ovens
New ovens require a burn off period to break in the oven and eliminate unappetizing odors from
penetrating the food product. These odors are typically from curing of the porcelain enamel oven cavity
parts.
Turn on gas to unit and set the thermostat to 475°F (246°C). Allow the oven to operate at this
temperature for 30 to 45 minutes.
Griddles
Before leaving the factory the griddle is coated with vegetable oil as a rust inhibitor. Remove this film
when the griddle plate is being cleaned prior to its first cooking use. Heat the griddle to 200-300°F to
loosen and melt the coating, then clean the surface with a non-corrosive, grease dissolving commercial
cleaner, following the manufacturer’s directions. Rinse thoroughly and wipe dry with a soft clean cloth.
Clean all accessories.
The griddle plate is steel, but the surface is soft and can be scored or dented by
careless use of spatulas or scrappers. Be careful not to dent, scratch or gouge the plate. Do
not try to knock off loose food that may be on the spatula by tapping the corner edge of the
spatula on the griddle surface.
Season the griddle to avoid possible surface corrosion before first use, and after every cleaning. Heat
griddle to a low temperature (300-350°F) and apply a small amount of cooking oil – about one ounce
per square foot of surface. Use a soft lint-free cloth to spread the oil over the entire griddle surface to
create a thin film. Wipe off any excess oil with a cloth. Repeat the procedure until the griddle has a
slick, mirror-like finish.
LIGHTING AND SHUTTING DOWN PILOTS
TOP SECTIONS
Open Top, Manual Griddle
1. Remove front row of grates (Open Top Only).
2. Turn the main gas supply valve to the ON position.
3. Light all standing pilots.
Open Top - Pilot access can be reached under the grate support beam running from left to right.
Manual Griddle – Pilot access can be reached under the griddle plate through the slotted opening in
the manifold cover near the burner valve knob.