Wolf Cinema DCX-1500i, DCX-1500FD, DCX-1000i, DCX-1000FD Product Sheet

Digital Cinema Three Chip DLP™ Projectors
DCX-500FD
DCX-500i
DCX-1000FD
DCX-1000i
DCX-1500FD
DCX-1500i
Wolf Cinema • 2431 Fifth Street Berkeley CA 94710 Tel: 510.843.4500 Fax: 510.843.7120 www.wolfcinema.com
Light Engine Cinema Contrast three chip DLP™
Color Filter Filmic Color Correction Filter Filmic Color Correction Filter Filmic Color Correction Filter Filmic Color Correction Filter Filmic Color Correction Filter Filmic Color Correction Filter Lamp Xenon lamp 500W Xenon lamp 500W Xenon lamp 1000W Xenon lamp 1000W Xenon lamp 1225W Xenon lamp 1225W Lens System VariScope constant height lens
Lens Options
Gamma Correction
Picture Quality Multi Standard Color Management
Communications RS232 in and out
Inputs 6 HDMI 1.3 inputs (1 on front panel), 2
Outputs 1 HDMI 1080P Video (set to native
Contrast Ratio 2,500- 50,000:1 full on/off *** 2,500- 50,000:1 full on/off *** 2,500- 50,000:1 full on/off *** 2,500- 50,000:1 full on/off *** 2,500- 50,000:1 full on/off *** 2,500- 50,000:1 full on/off *** Lumens 2500*** 2500*** 5500*** 5500*** 7250*** 7250*** Lamp Life 2500 to 4000 depending on lamp
Power 100 VAC to 240 VAC ± 10% @
Dimensions Length: 41 5/8
Dimensions with VariScope 2.35
Options
† Preliminary Lens Options
* Use of VariScope features does not allow for full zoom range of lens. Please see manual for details ** VariScope feature not available with this lens option. *** Depending on lamp power setting, installed iris and iris setting.
light engine
system
.67:1** RP lens
1.1:1** FP lens
1.4-1.8:1* Film 1 Correction
Film 2 Correction B&W Film Correction Incandescent Light Correction Fluorescent Light Correction Sunlight Correction
and Calibration Control White Field Uniformity/Correction
IR input Wolf Sentry IP monitoring and control
Component, 1 S-Video, 1 Composite
rate of display) 1 HDMI audio loop out with delay
power setting
50/60 Hz, Power consumption: 900W maximum, Thermal dissipation: 3000 BTU/hr, Operating current: 9.5A @ 100V/5A @ 200V
Width: 29 7/8 Height: 12 1/8
Length: 41 5/8 Width: 29 7/8 Height: 12 1/8
VariScope 2.35 Automated 2.35 lens and motor for use with VariScope lenses Wolf Warp Geometric distortion correction for
more exible installation solutions
1.8-2.6:1*
2.6-4.1:1*
4.1-6.9:1*
Cinema Contrast three chip DLP™ light engine
VariScope constant height lens system
.67:1** RP lens
1.1:1** FP lens
1.4-1.8:1* Film 1 Correction
Film 2 Correction B&W Film Correction Incandescent Light Correction Fluorescent Light Correction Sunlight Correction
Multi Standard Color Management and Calibration Control White Field Uniformity/Correction
RS232 in and out IR input Wolf Sentry IP monitoring and control
6 HDMI 1.3 inputs (1 on front panel), 2 Component, 1 S-Video, 1 Composite
1 HDMI 1080P Video (set to native rate of display) 1 HDMI audio loop out with delay
2500 to 4000 depending on lamp power setting
100 VAC to 240 VAC ± 10% @ 50/60 Hz, Power consumption: 900W maximum, Thermal dissipation: 3000 BTU/hr, Operating current: 9.5A @ 100V/5A @ 200V
Length: 21 1/2 Width: 28 1/4 Height: 11 1/2
Length: 31 3/4 Width: 28 1/4 Height: 11 1/2
VariScope 2.35 Automated 2.35 lens and motor for use with VariScope lenses Wolf Warp Geometric distortion correction for
more exible installation solutions
1.8-2.6:1*
2.6-4.1:1*
4.1-6.9:1*
Cinema Contrast three chip DLP™ light engine
VariScope constant height lens system
.67:1** RP lens
1.1:1** FP lens
1.4-1.8:1* Film 1 Correction
Film 2 Correction B&W Film Correction Incandescent Light Correction Fluorescent Light Correction Sunlight Correction
Multi Standard Color Management and Calibration Control White Field Uniformity/Correction
RS232 in and out IR input Wolf Sentry IP monitoring and control
6 HDMI 1.3 inputs (1 on front panel), 2 Component, 1 S-Video, 1 Composite
1 HDMI 1080P Video (set to native rate of display) 1 HDMI audio loop out with delay
2500 to 4000 depending on lamp power setting
100 VAC to 240 VAC ± 10% @ 50/60 Hz, Power consumption: 1500W maximum, Thermal dissipation: 5460 BTU/hr, Operating current: 10.4A @ 100V/8A @ 200V
Length: 41 5/8 Width: 29 7/8 Height: 12 1/8
Length: 41 5/8 Width: 29 7/8 Height: 12 1/8
VariScope 2.35 Automated 2.35 lens and motor for use with VariScope lenses Wolf Warp Geometric distortion correction for
more exible installation solutions
1.8-2.6:1*
2.6-4.1:1*
4.1-6.9:1*
Cinema Contrast three chip DLP™ light engine
VariScope constant height lens system
.67:1** RP lens
1.1:1** FP lens
1.4-1.8:1* Film 1 Correction
Film 2 Correction B&W Film Correction Incandescent Light Correction Fluorescent Light Correction Sunlight Correction
Multi Standard Color Management and Calibration Control White Field Uniformity/Correction
RS232 in and out IR input Wolf Sentry IP monitoring and control
6 HDMI 1.3 inputs (1 on front panel), 2 Component, 1 S-Video, 1 Composite
1 HDMI 1080P Video (set to native rate of display) 1 HDMI audio loop out with delay
2500 to 4000 depending on lamp power setting
100 VAC to 240 VAC ± 10% @ 50/60 Hz, Power consumption: 1500W maximum, Thermal dissipation: 5460 BTU/hr, Operating current: 10.4A @ 100V/8A @ 200V
Length: 21 1/2 Width: 28 1/4 Height: 11 1/2
Length: 31 3/4 Width: 28 1/4 Height: 11 1/2
VariScope 2.35 Automated 2.35 lens and motor for use with VariScope lenses Wolf Warp Geometric distortion correction for
more exible installation solutions
1.8-2.6:1*
2.6-4.1:1*
4.1-6.9:1*
Cinema Contrast three chip DLP™ light engine
VariScope constant height lens system
.67:1** RP lens
1.1:1** FP lens
1.4-1.8:1* Film 1 Correction
Film 2 Correction B&W Film Correction Incandescent Light Correction Fluorescent Light Correction Sunlight Correction
Multi Standard Color Management and Calibration Control White Field Uniformity/Correction
RS232 in and out IR input Wolf Sentry IP monitoring and control
6 HDMI 1.3 inputs (1 on front panel), 2 Component, 1 S-Video, 1 Composite
1 HDMI 1080P Video (set to native rate of display) 1 HDMI audio loop out with delay
2500 to 4000 depending on lamp power setting
200 VAC to 240 VAC ± 10% @ 50/60 Hz, Power consumption: 2000W maximum, Thermal dissipation: 6825 BTU/hr, Operating current: 10A @ 200V
Length: 41 5/8 Width: 29 7/8 Height: 12 1/8
Length: 41 5/8 Width: 29 7/8 Height: 12 1/8
VariScope 2.35 Automated 2.35 lens and motor for use with VariScope lenses Wolf Warp Geometric distortion correction for
more exible installation solutions
1.8-2.6:1*
2.6-4.1:1*
4.1-6.9:1*
Cinema Contrast three chip DLP™ light engine
VariScope constant height lens system
.67:1** RP lens
1.1:1** FP lens
1.4-1.8:1* Film 1 Correction
Film 2 Correction B&W Film Correction Incandescent Light Correction Fluorescent Light Correction Sunlight Correction
Multi Standard Color Management and Calibration Control White Field Uniformity/Correction
RS232 in and out IR input Wolf Sentry IP monitoring and control
6 HDMI 1.3 inputs (1 on front panel), 2 Component, 1 S-Video, 1 Composite
1 HDMI 1080P Video (set to native rate of display) 1 HDMI audio loop out with delay
2500 to 4000 depending on lamp power setting
200 VAC to 240 VAC ± 10% @ 50/60 Hz, Power consumption: 2000W maximum, Thermal dissipation: 6825 BTU/hr, Operating current: 10A @ 200V
Length: 21 1/2 Width: 28 1/4 Height: 11 1/2
Length: 31 3/4 Width: 28 1/4 Height: 11 1/2
VariScope 2.35 Automated 2.35 lens and motor for use with VariScope lenses Wolf Warp Geometric distortion correction for
more exible installation solutions
1.8-2.6:1*
2.6-4.1:1*
4.1-6.9:1*
Loading...