Wolf Appliance Company WWD30O User Manual

INSTALLATION GUIDE
Warming Drawers
Contents
Important Note
Wolf Warming Drawers . . . . . . . . . . . . . . . . . . . . . . . . . 3
Installation Considerations . . . . . . . . . . . . . . . . . . . . . . 4
Warming Drawer Specifications . . . . . . . . . . . . . . . . . . 8
Warming Drawer Installation . . . . . . . . . . . . . . . . . . . 14
Service Information . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Features and specifications are subject to change at any time without notice. Visit wolfappliance.com/specs for the most up-to-date information.
IMPORTANT NOTE: Throughout this guide, dimensions in parentheses are millimeters unless otherwise specified.
o ensure the safe and efficient use of Wolf equipment,
T please take note of the following types of highlighted information throughout this guide:
IMPORTANT NOTE highlights information that is especially important.
CAUTION signals a situation where minor injury or product damage may occur if instructions are not followed.
WARNING states a hazard that may cause serious injury or death if precautions are not followed.
Wolf Warming Drawers 3
wolfappliance.com/specs
Warming Drawer Installation
IMPORTANT NOTE: T
his installation must be completed
by a qualified installer or Wolf factory certified service.
Read this entire installation guide prior to installation and save for the local inspector’s reference. The homeowner should keep this installation guide for future reference.
IMPORTANT NOTE: The warming drawer must be installed
with a Wolf stainless steel or integrated drawer front.
This appliance must be installed in accordance with National Electrical Codes, as well as all state, municipal and local codes. The correct voltage, frequency and amperage must be supplied to the appliance from a dedi­cated, grounded circuit which is protected by a properly sized circuit breaker or time delay fuse. The proper voltage, frequency and amperage ratings are listed on the product rating plate.
Record the model and serial numbers before installing the warming drawer. Both numbers are listed on the product rating plate, located on the left front floor area of the inner cabinet. To access the rating plate, the drawer must be fully open. Refer to the illustration below.
Wolf Warming Drawer
Model Number
Serial Number
RATING
PLATE
Location of rating plate.
Installation Considerations 4
Installation Considerations
The warming drawer must be installed with a Wolf
stainless steel or integrated drawer front. Make sure you have the accessory drawer front called for in your installation. Specific installation instructions are included with the drawer front.
For all installations, the warming drawer must be fully
enclosed, top and bottom.
The warming drawer platform must be able to support
200 lbs
(25) above the toe kick to allow for the warming drawer
trim which overlaps
(90 kg). The platform must be a minimum of 1"
5
/8" (16) on all four sides.
Check with local utilities for electrical codes that apply
in your area. Local codes vary. Installation, electrical connections and grounding must comply with applica­ble codes. In the absence of local codes, the drawer should be installed in accordance with National Electri­cal Code ANSI/NFPA 70-1990 or latest edition.
TOOLS AND MATERIALS REQUIRED
Minimum3/4" (19) thick lumber for the solid platform
that supports the warming drawer—must be able to support 200 lbs
(90 kg).
Wood screws and hardware to install the platform.
Lumber for anti-tip block.
Power saw.
Level.
Drill and
1
/16" bit,1/2" bit also for integrated drawer
front application.
Phillips screwdriver.
2 wood screws (provided).
Wood cleats (optional).
Model WWD30O is CSA approved for outdoor
installations.
Installation Considerations 5
wolfappliance.com/specs
Combination Installations
efer to the illustrations showing combination installations
R on pages 10–13. Also refer to installation instructions provided with the other Wolf products.
The warming drawer may be installed in combination
with a Wolf built-in oven and/or microwave oven. Additional clearance between warming drawer and oven openings may be required. To allow the warming drawer trim and the oven trim to meet, a platform may be used to separate the two openings. This will act as the support platform for the oven and the anti-tip device for the warming drawer. An anti-tip block may be installed at the rear of the cabinet in place of the platform. If the warming drawer is installed above an oven, a
7
/8" (22) platform is required to allow
for clearance of overlaps.
The warming drawer may be installed below a Wolf
cooktop or sealed burner rangetop. Allow enough room for gas and electrical connections for the cooktop.
The warming drawer may be installed next to or above
another Wolf warming drawer.
7
/8" (22)
Electrical Requirements
he electrical supply should be located as shown in the
T illustration for your specific installation on the following pages. A separate circuit, servicing only this appliance is required.
IMPORTANT NOTE: You must follow all National Electrical
Code regulations. In addition, be aware of local codes and ordinances when installing your service.
If two warming drawers are installed side by side, they can operate from the same electrical outlet. A 30 amp circuit breaker is required for this installation.
IMPORTANT NOTE: When installed outdoors, a ground
fault circuit interrupter (GFCI) is required to reduce the risk of electrical shock.
Electrical Requirements
Power Supply 120 V AC, 50/60 Hz
Circuit Breaker 15 or 20 amp
Receptacle 3-prong grounding-type
Model WWD30O may be installed below a Wolf
outdoor grill.