Wolf Appliance Company ICBIF15-S User Manual

FRYER MODULE
INSTALLATION INSTRUCTIONS
MÓDULO DE FREIDORA INSTRUCCIONES DE INSTALACIÓN
FRITEUSE INSTRUCTIONS D’INSTALLATION
FRIGGITRICE ISTRUZIONI PER L’INSTALLAZIONE
ENGLISH 4
ESPÃNOL 14
FRANÇAIS 24
ITALIANO 34
3
CONTACT INFORMATION
Website: wolfappliance.com
As you follow these instructions, you will notice WARNING and CAUTION symbols. This blocked information is important for the safe and efficient installation of Wolf equip­ment. There are two types of potential hazards that may occur during installation.
WOLF®is a registered trademark of Wolf Appliance Company, Inc.
signals a situation where minor injury or product damage may occur if you do not follow instructions.
states a hazard that may cause serious injury or death if precautions are not followed.
Another footnote we would like to identify is IMPORTANT NOTE: This highlights informa­tion that is especially relevant to a problem­free installation.
WOLF FRYER MODULE
INSTALLATION REQUIREMENTS
IMPORTANT NOTE:
Save these Installation
Instructions for the local inspector’s use.
Please read the entire Installation Instructions prior to installation.
This installation must be completed by a qualified technician.
Installer:
please retain these instructions for local inspector’s reference, then leave them with the homeowner.
Homeowner:
please read and keep these instructions for future reference and be sure to read the entire Use & Care Information prior to use.
IMPORTANT NOTE:
This appliance must be installed in accordance with local codes. The correct voltage, frequency and amperage must be supplied to the appliance from a dedicated, grounded circuit which is protected by a properly sized circuit breaker or time delay fuse. The proper voltage, frequency, and amperage ratings are listed on the product rating plate.
Record the model and serial numbers before installing the fryer module. Both numbers are listed on the product rating plate located on the underside of the module. Refer to the illustration below.
BEFORE YOU START
IMPORTANT NOTE:
Installation and service must be performed by a qualified installer or service agency.
Installation of the fryer module must meet the minimum clearance requirements for safe operation. Refer to Site Preparation on page 6.
The fryer module must be installed in a base cabinet that allows access to the manual drain valve for draining the oil. Refer to the Manual Drain Outlet section on page 8.
If the fryer module is to be used with any combination of additional cooktop units or modules, refer to the Multiple Cooktop Installation section on page 8.
Electrical installation must be adequate and in compliance with all local codes and ordinances. Electrical ground is required, refer to Electrical Requirements on page 10.
IMPORTANT NOTE:
A ventilation hood is recommended (but not required) for use with the Wolf electric fryer module.
This module is intended for indoor use.
odel ICBIF15/S
M
Model Number
ICBIF15/S
Serial Number
plate under module
Rating plate location
Location of rating
5
WOLF FRYER MODULE
SITE PREPARATION
IMPORTANT NOTE:
Installation of the Wolf electric fryer module must meet the following location requirements. All dimensions listed are minimum requirements for safe operation. Refer to the illustration below.
To eliminate the risk of burns or fire by reaching over heated surface units, cabinet storage space located above the surface units should be avoided. If cabinet storage is to be provided, the risk can be reduced by installing a ventilation hood that projects horizontally a minimum of 127 mm beyond the bottom cabinets.
C
G
D
LOCATION IN COUNTERTOP
A)
Minimum flat countertop surface. Must be equal to or greater than the width of the module(s).
B)
Minimum 152 mm wide clearance from the module side edge to any combustible surface up to 457 mm above the countertop (noted by shaded area).
OVERHEAD CABINET DIMENSIONS
C)
Minimum spacing between overhead side cabinets must be greater than or equal to the nominal width of the module(s).
D)
Minimum 457 mm vertical distance from the countertop to the bottom of side cabinets within minimum side clearance.
E)
Minimum vertical distance between the countertop and combustible materials above the module must be 762 mm.
F)
Minimum 25 mm from rear wall.
G)
Maximum 330 mm depth of overhead and side cabinets directly above and within side clearance.
E
F
Minimum installation clearances
6
Failure to locate the fryer module without the proper clearances will result in a fire hazard.
B
A
B
INSTALLATION INSTRUCTIONS
INSTALLATION SPECIFICATIONS
The illustrations below provide the overall dimensions, finished cut-out dimensions and electrical placement for the Wolf electric fryer module.
The fryer module is designed to fit a standard 610 mm deep base cabinet with 635 mm deep countertop. Before making the countertop cut­out, verify that the module will clear the side walls of the base cabinet below.
533
mm
OVERALL
DEPTH
MODEL
ICBIF15/S
DIMENSIONS
Overall Width 381 mm
Overall Height 343 mm
Overall Depth 533 mm
Minimum Cabinet Depth 578 mm
Minimum Height Clearance 343 mm
Cut-Out Width 356 mm
Cut-Out Depth 489 mm
Unit dimensions may vary to 3 mm.
381
mm
OVERALL WIDTH
191
mm
Overall Dimensions
343
mm
TO DRAIN
OUTLET
838
mm
330 mm
max
489
64
mm
**
NOTE: Application shown allows for installation of two 381 mm modules side-by-side with 838 mm recommended cabinet width. 457 mm recommended cabinet width for installation of single 381 mm cooktop or module. NOTE: Fryer module must be installed in a base cabinet with access to manual valve at base of unit to drain oil into heat resistant receptacle. *Minimum clearance from both side edges of cooktop cut-out to combustible materials up to 457 mm above countertop. **Minimum clearance from rear edge of cooktop cut-out to combustible materials up to 457 mm above countertop.
mm
COOKTOP CUT-OUT
DEPTH
314
mm
194
mm
DRAIN OUTLET
LOCATION
Installation Specifications
457
mm
64
mm
min
914
mm
STANDARD
FLOOR TO
COUNTERTOP
HEIGHT
178 mm
min
CUT-OUT TO
COMBUSTIBLE
MATERIALS
(BOTH SIDES)
DRAIN OUTLET
LOCATION
*
COOKTOP CUT-OUT
COOKTOP CUT-OUT
CABINET WIDTH
356
mm
WIDTH
314
mm
152
mm
E
381
mm
356
mm
WIDTH
RECOMMENDED
343
mm
381
mm
762
mm
COUNTERTOP TO
COMBUSTIBLE
MATERIALS
ABOVE COOKTOP
Countertop Cut-Out Dimensions
489
mm
64
min
mm
COOKTOP
CUT-OUT DEPTH
FRONT OF COUNTERTOP
7
WOLF FRYER MODULE
MANUAL DRAIN OUTLET
IMPORTANT NOTE:
The fryer module must be installed in a base cabinet that allows access to the manual drain valve for draining the oil. A heat-resistant bucket must be positioned under the drain outlet to accept the oil. The bucket must be able to hold 7.6 L. Refer to the Instal­lation Specifications illustration on page 7 for location of the manual drain outlet.
MULTIPLE COOKTOP INSTALLATION
IMPORTANT NOTE:
If the fryer module is to be used with a combination of additional cooktop units or modules with a filler strip, the cut-out width is calculated by adding the corresponding units' cut-out dimensions plus 32 mm for each additional unit.
When multiple units are installed side by side, each unit must have its own separate recom­mended electrical circuit.
When two or more modules are installed together, an integrated module filler strip (IFILLER/S) is recommended. Contact your Wolf dealer for information on accessories.
IMPORTANT NOTE:
Review specific installation instructions for product to product capabilities.
This fryer module must be installed at least 381 mm away from any open-flame cooking device. The open flame may cause ignition of oil.
This fryer module must be installed at least 381 mm away from a Wolf steamer module, as contact between water and hot oil may cause burns from steam and hot oil.
1518
1511
1276
1130
1124
mm / 762 mm COOKTOP AND ONE MODULE
TWO MODULES WIDTH
356
mm
64
min
Countertop cut-out dimensions for installation of multiple cooktops
8
CUT-OUT
mm
WIDTH
FRONT OF COUNTERTOP
mm FOUR MODULES WIDTH OR
mm / 762 mm COOKTOP AND TWO MODULES OR
mm / 914 mm COOKTOP AND ONE MODULE
mm THREE MODULES WIDTH OR
743
mm
489
mm
CUT-OUT
DEPTH
INSTALLATION INSTRUCTIONS
VENTILATION OPTIONS
IMPORTANT NOTE:
It is recommended that you operate the Wolf electric fryer module with either a Wolf cooktop or Pro ventilation hood or hood liner. Contact your Wolf dealer for details.
Cooktop Wall Hood –
762 mm or 914 mm
widths in classic stainless steel.
Cooktop Island Hood –
1067 mm width in
classic stainless steel.
Pro Wall Hood –
559 mm, 610 mm or 686 mm depths and 762 mm to 1676 mm widths in classic stainless steel.
Pro Island Hood –
914 mm to 1676 mm
widths in classic stainless steel.
Pro Hood Liner –
available in widths to
accommodate 914 mm to 1524 mm hoods.
All hoods have welded seams, sealed halogen lighting and removable, dishwasher-safe filters.
IMPORTANT NOTE:
Wolf does not recom­mend the use of downdraft ventilation with the fryer module.
ACCESSORIES
Optional accessories are available through your Wolf dealer.
IMPORTANT NOTE:
When installing a ventila­tion hood, refer to the specific requirements of the hood for the minimum dimension to the countertop.
9
WOLF FRYER MODULE
ELECTRICAL REQUIREMENTS
Verify that power is disconnected from the junction box before proceeding.
Required Power Supply
220–240 V AC, 50–60 Hz, 15 amp service
Maximum Connected Load
2.6 kW
The Wolf electric fryer module requires a separate, grounded 3-wire 220–240 V AC, 50 –60 Hz, 15 amp service with its own circuit breaker or fuse. A properly rated cord should be attached to the power supply box of the fryer as shown in the illustration below. Open the power box to expose the screws with corresponding numbers. Loosen the 1, 5, and ground screws. Run the cord through the circular hole and into the power supply box. Attach the Neutral wire to the number 1 position. Line should be attached to the 5 position and attach the ground to the corre­sponding ground screw. After tightening the screws, close the cover to the power supply box without pinching any of the wires.
You must follow local codes and ordinances when installing your service.
IMPORTANT NOTE:
The correct voltage, frequency and amperage must be supplied to the appliance from a dedicated, grounded circuit which is protected by a properly sized circuit breaker or time delay fuse. The proper voltage, frequency, and amperage ratings are listed on the product rating plate located on the underside of the module. Refer to the illus­tration on page 5.
The wiring diagram covering the control circuit is located inside the module control box.
The complete appliance must be properly grounded at all times when electrical power is applied.
Improper connection can result in a fire hazard!
IMPORTANT NOTE:
To avoid electrical shock when disconnecting the fryer module, all poles/wires must be disconnected from the power supply box.
10
Power supply box
INSTALLATION INSTRUCTIONS
MODULE INSTALLATION
To prevent pollution from entering the controller and transformer area, attach the foam strip to the underside of the module frame. Refer to the illustration below.
Gently lower the fryer module into the cut-out area in the countertop and center. Check that the front edge of module is parallel to the front edge of the countertop. Check that all required clearances are met.
To attach the brackets to the sides of the module, insert the clip into the rectangular punchout in the pan, and push down. Install the clamping screw into the bracket and tighten until the screw contacts the underside of the countertop. Do not overtighten screws. Refer to the illustration below.
IMPORTANT NOTE:
Do not use caulk or silicone to seal the module to the countertop. The unit must be readily removable for service.
BEFORE OPERATING
Read the entire Wolf Fryer Module Use & Care Information included with the module. Impor­tant safety and service information is contained within the book.
Thoroughly clean the stainless steel fryer basin, wire basket hanger and fryer baskets with mild soap and water before use.
Never operate the fryer module without oil; damage to the unit may result. Oil must be added to the fryer basin before turning on the module.
MODULE
FOAM STRIP
Foam strip Installation brackets
MODULE
BRACKET
CLIP
COUNTERTOP
89
mm
CLAMPING
SCREW
11
WOLF FRYER MODULE
MODULE REMOVAL
IMPORTANT NOTE:
Removal of the fryer module should only be performed by a Wolf authorized service center technician.
If removing the fryer module is necessary for cleaning or service, first disconnect the electric supply. Remove the mounting brackets on each side of module and remove. To reinstall, refer to page 11.
The module must be disconnected from power prior to removal and service.
TROUBLESHOOTING
IMPORTANT NOTE:
If the fryer module does not operate properly, follow these troubleshooting steps:
Verify that power is being supplied to the module.
Check electrical connections to ensure that the installation has been completed correctly.
Follow troubleshooting procedures as described in the Wolf Fryer Module Use & Care Information.
If the module still does not work, contact your Wolf dealer or regional distributor. Do not attempt to repair the cooktop module yourself.
12
INSTALLATION INSTRUCTIONS
IF YOU NEED SERVICE
For service in your area, contact either your Wolf dealer or visit the Locator page of our website,
wolfappliance.com
to find the
regional distributor by country.
When calling for service, be sure to have the model and serial number of the fryer module. Both numbers are listed on the product rating plate located on the under­side of the module. Refer to the illustration on page 5.
IMPORTANT NOTE:
Installation and service must be performed by a qualified installer or service agency.
CONTACT INFORMATION
Website: wolfappliance.com
The information and images are the copyright property of Wolf Appliance Company affiliate of Sub-Zero Freezer Company, Inc. Neither this book nor any information or images contained herein may be copied or used in whole or in part without the express written permission of Wolf Appliance Company, Inc., an affiliate of Sub-Zero Freezer Company, Inc.
olf Appliance Company, Inc. all rights reserved.
©W
, Inc., an
13
INFORMACIÓN DE CONTACTO
Página Web: wolfappliance.com
A medida que siga las instrucciones que aparecen en esta guía, encontrará símbolos de AVISO y PRECAUCIÓN. Estos recuadros de información son importantes para instalar el equipo de Wolf de forma segura y eficaz. Existen dos tipos de posibles riesgos que pueden producirse durante una instalación.
WOLF®es una marca comercial registrada de Wolf Appliance Company, Inc.
Indica una situación en la que pueden producirse daños leves o secundarios en el producto si no se siguen las instrucciones.
Indica que existe peligro de que se produzcan heridas personales graves o incluso puede provocar la muerte si no se siguen las precauciones.
Otro tipo de anotación que nos gustaría resaltar es la que se incluye en NOTA IMPOR­TANTE: En esta nota se resalta la información que resulta especialmente importante para que la instalación se realice sin problemas.
Loading...