As you follow these instructions, you will
notice WARNING and CAUTION symbols.
This blocked information is important for the
safe and efficient installation of Wolf equipment. There are two types of potential
hazards that may occur during installation.
WOLF®is a registered trademark of Wolf Appliance Company, Inc.
signals a situation where minor injury or
product damage may occur if you do not
follow instructions.
states a hazard that may cause serious
injury or death if precautions are not
followed.
Another footnote we would like to identify is
IMPORTANT NOTE: This highlights information that is especially relevant to a problemfree installation.
WOLF FRYER MODULE
INSTALLATION REQUIREMENTS
IMPORTANT NOTE:
Save these Installation
Instructions for the local inspector’s use.
Please read the entire Installation
Instructions prior to installation.
This installation must be completed by a
qualified technician.
Installer:
please retain these instructions
for local inspector’s reference, then leave
them with the homeowner.
Homeowner:
please read and keep
these instructions for future reference and
be sure to read the entire Use & Care
Information prior to use.
IMPORTANT NOTE:
This appliance must be
installed in accordance with local codes. The
correct voltage, frequency and amperage
must be supplied to the appliance from a
dedicated, grounded circuit which is protected
by a properly sized circuit breaker or time
delay fuse. The proper voltage, frequency,
and amperage ratings are listed on the
product rating plate.
Record the model and serial numbers before
installing the fryer module. Both numbers are
listed on the product rating plate located on
the underside of the module. Refer to the
illustration below.
BEFORE YOU START
IMPORTANT NOTE:
Installation and service
must be performed by a qualified installer or
service agency.
Installation of the fryer module must meet
the minimum clearance requirements for
safe operation. Refer to Site Preparation on
page 6.
The fryer module must be installed in a
base cabinet that allows access to the
manual drain valve for draining the oil.
Refer to the Manual Drain Outlet section
on page 8.
If the fryer module is to be used with any
combination of additional cooktop units or
modules, refer to the Multiple Cooktop
Installation section on page 8.
Electrical installation must be adequate
and in compliance with all local codes and
ordinances. Electrical ground is required,
refer to Electrical Requirements on page 10.
IMPORTANT NOTE:
A ventilation hood is
recommended (but not required) for use with
the Wolf electric fryer module.
This module is intended for indoor use.
odel ICBIF15/S
M
Model Number
ICBIF15/S
Serial Number
plate under module
Rating plate location
Location of rating
5
WOLF FRYER MODULE
SITE PREPARATION
IMPORTANT NOTE:
Installation of the Wolf
electric fryer module must meet the following
location requirements. All dimensions listed
are minimum requirements for safe operation.
Refer to the illustration below.
To eliminate the risk of burns or fire by
reaching over heated surface units,
cabinet storage space located above the
surface units should be avoided. If
cabinet storage is to be provided, the risk
can be reduced by installing a ventilation
hood that projects horizontally a
minimum of 127 mm beyond the bottom
cabinets.
C
G
D
LOCATION IN COUNTERTOP
A)
Minimum flat countertop surface. Must be
equal to or greater than the width of the
module(s).
B)
Minimum 152 mm wide clearance from the
module side edge to any combustible
surface up to 457 mm above the countertop
(noted by shaded area).
OVERHEAD CABINET DIMENSIONS
C)
Minimum spacing between overhead side
cabinets must be greater than or equal to
the nominal width of the module(s).
D)
Minimum 457 mm vertical distance from
the countertop to the bottom of side
cabinets within minimum side clearance.
E)
Minimum vertical distance between the
countertop and combustible materials
above the module must be 762 mm.
F)
Minimum 25 mm from rear wall.
G)
Maximum 330 mm depth of overhead and
side cabinets directly above and within side
clearance.
E
F
Minimum installation clearances
6
Failure to locate the fryer module
without the proper clearances will result
in a fire hazard.
B
A
B
INSTALLATION INSTRUCTIONS
INSTALLATION SPECIFICATIONS
The illustrations below provide the overall
dimensions, finished cut-out dimensions and
electrical placement for the Wolf electric fryer
module.
The fryer module is designed to fit a standard
610 mm deep base cabinet with 635 mm deep
countertop. Before making the countertop cutout, verify that the module will clear the side
walls of the base cabinet below.
533
mm
OVERALL
DEPTH
MODEL
ICBIF15/S
DIMENSIONS
Overall Width381 mm
Overall Height343 mm
Overall Depth533 mm
Minimum Cabinet Depth578 mm
Minimum Height Clearance343 mm
Cut-Out Width356 mm
Cut-Out Depth489 mm
Unit dimensions may vary to 3 mm.
381
mm
OVERALL WIDTH
191
mm
Overall Dimensions
343
mm
TO DRAIN
OUTLET
838
mm
330 mm
max
489
64
mm
**
NOTE: Application shown allows for installation of two 381 mm modules side-by-side with 838 mm recommended cabinet width. 457 mm
recommended cabinet width for installation of single 381 mm cooktop or module. NOTE: Fryer module must be installed in a base cabinet with
access to manual valve at base of unit to drain oil into heat resistant receptacle. *Minimum clearance from both side edges of cooktop cut-out
to combustible materials up to 457 mm above countertop. **Minimum clearance from rear edge of cooktop cut-out to combustible materials up
to 457 mm above countertop.
mm
COOKTOP CUT-OUT
DEPTH
314
mm
194
mm
DRAIN OUTLET
LOCATION
Installation Specifications
457
mm
64
mm
min
914
mm
STANDARD
FLOOR TO
COUNTERTOP
HEIGHT
178 mm
min
CUT-OUT TO
COMBUSTIBLE
MATERIALS
(BOTH SIDES)
DRAIN OUTLET
LOCATION
*
COOKTOP CUT-OUT
COOKTOP CUT-OUT
CABINET WIDTH
356
mm
WIDTH
314
mm
152
mm
E
381
mm
356
mm
WIDTH
RECOMMENDED
343
mm
381
mm
762
mm
COUNTERTOP TO
COMBUSTIBLE
MATERIALS
ABOVE COOKTOP
Countertop Cut-Out
Dimensions
489
mm
64
min
mm
COOKTOP
CUT-OUT DEPTH
FRONT OF COUNTERTOP
7
WOLF FRYER MODULE
MANUAL DRAIN OUTLET
IMPORTANT NOTE:
The fryer module must be
installed in a base cabinet that allows access to
the manual drain valve for draining the oil. A
heat-resistant bucket must be positioned under
the drain outlet to accept the oil. The bucket
must be able to hold 7.6 L. Refer to the Installation Specifications illustration on
page 7 for location of the manual drain outlet.
MULTIPLE COOKTOP INSTALLATION
IMPORTANT NOTE:
If the fryer module is to
be used with a combination of additional
cooktop units or modules with a filler strip,
the cut-out width is calculated by adding the
corresponding units' cut-out dimensions plus
32 mm for each additional unit.
When multiple units are installed side by side,
each unit must have its own separate recommended electrical circuit.
When two or more modules are installed
together, an integrated module filler strip
(IFILLER/S) is recommended. Contact your
Wolf dealer for information on accessories.
IMPORTANT NOTE:
Review specific
installation instructions for product to product
capabilities.
This fryer module must be installed at
least 381 mm away from any open-flame
cooking device. The open flame may
cause ignition of oil.
This fryer module must be installed at
least 381 mm away from a Wolf steamer
module, as contact between water and
hot oil may cause burns from steam and
hot oil.
1518
1511
1276
1130
1124
mm / 762 mm COOKTOP AND ONE MODULE
TWO MODULES WIDTH
356
mm
64
min
Countertop cut-out dimensions for installation of multiple cooktops
8
CUT-OUT
mm
WIDTH
FRONT OF COUNTERTOP
mm FOUR MODULES WIDTH OR
mm / 762 mm COOKTOP AND TWO MODULES OR
mm / 914 mm COOKTOP AND ONE MODULE
mm THREE MODULES WIDTH OR
743
mm
489
mm
CUT-OUT
DEPTH
INSTALLATION INSTRUCTIONS
VENTILATION OPTIONS
IMPORTANT NOTE:
It is recommended that
you operate the Wolf electric fryer module with
either a Wolf cooktop or Pro ventilation hood
or hood liner. Contact your Wolf dealer for
details.
Cooktop Wall Hood –
762 mm or 914 mm
widths in classic stainless steel.
Cooktop Island Hood –
1067 mm width in
classic stainless steel.
Pro Wall Hood –
559 mm, 610 mm or
686 mm depths and 762 mm to 1676 mm
widths in classic stainless steel.
Pro Island Hood –
914 mm to 1676 mm
widths in classic stainless steel.
Pro Hood Liner –
available in widths to
accommodate 914 mm to 1524 mm hoods.
All hoods have welded seams, sealed halogen
lighting and removable, dishwasher-safe
filters.
IMPORTANT NOTE:
Wolf does not recommend the use of downdraft ventilation with the
fryer module.
ACCESSORIES
Optional
accessories are
available through
your Wolf dealer.
IMPORTANT NOTE:
When installing a ventilation hood, refer to the specific requirements of
the hood for the minimum dimension to the
countertop.
9
WOLF FRYER MODULE
ELECTRICAL REQUIREMENTS
Verify that power is disconnected from
the junction box before proceeding.
Required Power Supply
220–240 V AC, 50–60 Hz, 15 amp service
Maximum Connected Load
2.6 kW
The Wolf electric fryer module requires a
separate, grounded 3-wire 220–240 V AC,
50 –60 Hz, 15 amp service with its own circuit
breaker or fuse. A properly rated cord should
be attached to the power supply box of the
fryer as shown in the illustration below. Open
the power box to expose the screws with
corresponding numbers. Loosen the 1, 5, and
ground screws. Run the cord through the
circular hole and into the power supply box.
Attach the Neutral wire to the number 1
position. Line should be attached to the 5
position and attach the ground to the corresponding ground screw. After tightening the
screws, close the cover to the power supply
box without pinching any of the wires.
You must follow local codes and ordinances
when installing your service.
IMPORTANT NOTE:
The correct voltage,
frequency and amperage must be supplied to
the appliance from a dedicated, grounded
circuit which is protected by a properly sized
circuit breaker or time delay fuse. The proper
voltage, frequency, and amperage ratings are
listed on the product rating plate located on
the underside of the module. Refer to the illustration on page 5.
The wiring diagram covering the control circuit
is located inside the module control box.
The complete appliance must be properly
grounded at all times when electrical
power is applied.
Improper connection can result in a fire
hazard!
IMPORTANT NOTE:
To avoid electrical shock
when disconnecting the fryer module, all
poles/wires must be disconnected from the
power supply box.
10
Power supply box
INSTALLATION INSTRUCTIONS
MODULE INSTALLATION
To prevent pollution from entering the
controller and transformer area, attach the
foam strip to the underside of the module
frame. Refer to the illustration below.
Gently lower the fryer module into the cut-out
area in the countertop and center. Check that
the front edge of module is parallel to the front
edge of the countertop. Check that all required
clearances are met.
To attach the brackets to the sides of the
module, insert the clip into the rectangular
punchout in the pan, and push down. Install
the clamping screw into the bracket and
tighten until the screw contacts the underside
of the countertop. Do not overtighten screws.
Refer to the illustration below.
IMPORTANT NOTE:
Do not use caulk or
silicone to seal the module to the countertop.
The unit must be readily removable for
service.
BEFORE OPERATING
Read the entire Wolf Fryer Module Use & Care
Information included with the module. Important safety and service information is
contained within the book.
Thoroughly clean the stainless steel fryer
basin, wire basket hanger and fryer baskets
with mild soap and water before use.
Never operate the fryer module without
oil; damage to the unit may result. Oil
must be added to the fryer basin before
turning on the module.
MODULE
FOAM
STRIP
Foam stripInstallation brackets
MODULE
BRACKET
CLIP
COUNTERTOP
89
mm
CLAMPING
SCREW
11
WOLF FRYER MODULE
MODULE REMOVAL
IMPORTANT NOTE:
Removal of the fryer
module should only be performed by a Wolf
authorized service center technician.
If removing the fryer module is necessary for
cleaning or service, first disconnect the electric
supply. Remove the mounting brackets on
each side of module and remove. To reinstall,
refer to page 11.
The module must be disconnected from
power prior to removal and service.
TROUBLESHOOTING
IMPORTANT NOTE:
If the fryer module
does not operate properly, follow these
troubleshooting steps:
Verify that power is being supplied to the
module.
Check electrical connections to ensure that
the installation has been completed
correctly.
Follow troubleshooting procedures as
described in the Wolf Fryer Module
Use & Care Information.
If the module still does not work, contact
your Wolf dealer or regional distributor. Do
not attempt to repair the cooktop module
yourself.
12
INSTALLATION INSTRUCTIONS
IF YOU NEED SERVICE
For service in your area, contact either your
Wolf dealer or visit the Locator page of our
website,
wolfappliance.com
to find the
regional distributor by country.
When calling for service, be sure to have
the model and serial number of the fryer
module. Both numbers are listed on the
product rating plate located on the underside of the module. Refer to the illustration
on page 5.
IMPORTANT NOTE:
Installation and service
must be performed by a qualified installer or
service agency.
CONTACT
INFORMATION
Website:
wolfappliance.com
The information and images are the copyright
property of Wolf Appliance Company
affiliate of Sub-Zero Freezer Company, Inc.
Neither this book nor any information or images
contained herein may be copied or used in whole
or in part without the express written permission
of Wolf Appliance Company, Inc., an affiliate of
Sub-Zero Freezer Company, Inc.
A medida que siga las instrucciones que
aparecen en esta guía, encontrará símbolos
de AVISO y PRECAUCIÓN. Estos recuadros
de información son importantes para instalar
el equipo de Wolf de forma segura y eficaz.
Existen dos tipos de posibles riesgos que
pueden producirse durante una instalación.
WOLF®es una marca comercial registrada de Wolf Appliance Company, Inc.
Indica una situación en la que pueden
producirse daños leves o secundarios
en el producto si no se siguen las
instrucciones.
Indica que existe peligro de que se
produzcan heridas personales
graves o incluso puede provocar la
muerte si no se siguen las precauciones.
Otro tipo de anotación que nos gustaría
resaltar es la que se incluye en NOTA IMPORTANTE: En esta nota se resalta la información
que resulta especialmente importante para
que la instalación se realice sin problemas.