As you follow these instructions, you will
notice WARNING and CAUTION symbols.
This blocked information is important for the
safe and efficient installation of Wolf equipment. There are two types of potential
hazards that may occur during installation.
WOLF®is a registered trademark of Wolf Appliance, Inc.
signals a situation where minor injury or
product damage may occur if you do not
follow instr
states a hazard that may cause serious
injury or death if precautions are not
followed.
Another footnote we would like to identify is
IMPORTANT NOTE: This highlights information that is especially relevant to a problemfree installation.
uctions.
WOLF ELECTRIC COOKTOPS
CLEAR
O
S
IM
HIGH
OF
F
ON
OFF
ON
S
I
M
HI
G
H
OFF
ON
SI
M
HI
GH
B
RI
DGE
ZON
E
2
ZON
E
3
HIGH
M
EL
T
OFF
ON
INSTALLATION REQUIREMENTS
IMPORTANT NOTE:
Save these Installation
Instructions for the local inspector’s use.
Please read the entire Installation Instruc-
ions prior to installation.
t
This installation must be completed by a
qualified technician.
Installer:
please retain these instructions
for local inspector’s reference, then leave
them with the homeowner.
Homeowner:
please read and keep these
instructions for future reference and be sure
to read the entire Use & Care Information
prior to use.
IMPORTANT NOTE:
This appliance must be
installed in accordance with National Electrical
Codes, as well as all state, municipal and local
codes. The correct voltage, frequency and
amperage must be supplied to the appliance
from a dedicated, grounded circuit which is
protected by a properly sized circuit breaker or
time delay fuse. The proper voltage, frequency,
and power ratings are listed on the product
rating plate.
Record the model and serial numbers before
installing the cooktop. Both numbers are on
the rating plate, located on the underside of
the cooktop. Refer to the illustration below.
BEFORE YOU START
Proper installation is your responsibility.
Have a qualified technician install this
ooktop. You must also assure that electri-
c
cal installation is adequate and in compliance with all local codes and ordinances.
Installations and repairs must be performed
y a qualified or licensed contractor or
b
electrician qualified or licensed by the state,
province, or region where this appliance is
being installed.
Make sure you have everything necessary
for correct installation. It is the responsibility of the installer to comply with the
installation clearances specified in this book
and on the product rating plate. The rating
plate is located on the underside of the
cooktop. Refer to the illustration below.
Electrical ground is required; see Electrical
Requirements on page 14.
Warranty service must be preformed by a
Wolf authorized service center.
This cooktop is intended for indoor use.
RATING PLATE
INFORMATION
Model Number
Serial Number
Location of rating
plate under cooktop
Rating plate location
3
WOLF ELECTRIC COOKTOPS
C
G
D
A
B
B
E
F
SITE PREPARATION
IMPORTANT NOTE:
Installation of the Wolf
electric cooktop must meet the following
ocation requirements. All dimensions listed
l
are minimum requirements for safe operation.
Refer to the illustration below.
To eliminate the risk of burns or fire by
reaching over heated surface units,
cabinet storage space located above the
surface units should be avoided. If
cabinet storage is to be pr
can be reduced by installing a ventilation
hood that projects horizontally a
minimum of 5" (127) beyond the bottom
cabinets.
ovided, the risk
LOCATION IN COUNTERTOP
inimum flat countertop surface. Must be
A)M
equal to or greater than cooktop width.
B)
Minimum 1" (25) wide clearance from the
cooktop side edge to any combustible
surface up to 18" (457) above the cooktop
(noted by shaded area).
OVERHEAD CABINET DIMENSIONS
C)
Minimum spacing between overhead side
cabinets must be greater than or equal to
the nominal width of the cooktop unit(s).
D)
Minimum 18" (457) vertical distance from
the countertop to the bottom of side
cabinets within minimum side clearance.
E)
Minimum vertical distance between the
countertop and combustible materials
above the cooktop must be 30" (762).
F)
Minimum 1" (25) from rear wall.
G)
Maximum 13" (330) depth of overhead and
side cabinets directly above and within side
clearance.
Minimum clearances for installation
4
Failure to locate the cooktop unit
without the proper clearances will result
in a fire hazard.
INSTALLATION INSTRUCTIONS
11/4" (32)
2"
(51)
2"
(51)
INSTALLATION SPECIFICATIONS
The illustrations on pages 6–11 provide the
overall dimensions, installation specifications
nd countertop cut-out for each of the Wolf
a
electric cooktop models.
These cooktops are designed to fit a standard
24" (610) deep base cabinet with a 25" (635)
eep countertop. Before making the counter-
d
top cut-out, verify that the cooktop will clear
the side walls of the base cabinet below.
Clearance is required for the conduit located at
the right rear of the cooktop. Refer to the illustration below for dimensions.
FRAMED ELECTRIC COOKTOPS
For framed models, a minimum 53/4" (146)
clearance is required between the countertop
and any combustible surface directly below
the cooktop.
Wolf framed electric cooktops are designed to
be installed in combination with other cooktop
units.
IMPORTANT NOTE:
When multiple cooktop
units are installed side by side, refer to the
countertop cut-out dimensions on page 9.
UNFRAMED ELECTRIC COOKTOPS
For unframed models, a minimum 61/4" (159)
clearance is required between the countertop
nd any combustible surface directly below
a
the cooktop.
IMPORTANT NOTE:
Unframed electric
cooktops are not designed to be installed in
combination with other cooktops.
IMPORTANT NOTE:
Unframed electric
cooktops cannot be installed with a downdraft
ventilation system.
For installation options of the unframed
electric cooktops, refer to Unframed Installations on pages 12–13.
Wolf framed electric cooktops can accommodate a Wolf downdraft ventilation system.
Refer to installation instructions provided with
the downdraft for additional specifications.
Conduit dimensions
Dimensions in parentheses are in
millimeters unless otherwise specified.
5
E
4" (102)
15"
(381)
15"
(381)
2"*min (51)
CUT-OUT TO
COMBUSTIBLE
MATERIALS
(BOTH SIDES)
133/8" (340)
COOKTOP CUT-OUT
WIDTH
133/8" (
340)
COOKTOP CUT-OUT
WIDTH
33" (838)
RECOMMENDED
CABINET WIDTH
18"
(457)
NOTE: Application shown allows for installation of two 15" (381) modules side-by-side with 33" (838) recommended cabinet width. 18" (457)
recommended cabinet width for installation of single 15" (381) cooktop or module. *Minimum clearance from both side edges of cooktop cut-out
to combustible materials up to 18" (457) above countertop. **Minimum clearance from rear edge of cooktop cut-out to combustible materials up
to 18" (457) above countertop.
191/4" (489)
COOKTOP CUT-OUT
DEPTH
21/2"min
(64)
36" (914)
STANDARD
FLOOR TO
COUNTERTOP
HEIGHT
13" max
(330)
30" (762)
COUNTERTOP TO
COMBUSTIBLE
MATERIALS
ABOVE COOKTOP
FRONT OF COUNTERTOP
21/2"min
(64)
191/4" (489)
COOKTOP
CUT-OUT DEPTH
2"**
(
51)
21"
(533)
OVERALL
DEPTH
15" (381)
OVERALL WIDTH
5" (127)33/4" (96)
CONDUIT
WOLF ELECTRIC COOKTOPS
FRAMED
MODEL CT15E
The illustrations below provide installation
specifications for Model CT15E.
If Model CT15E is installed above cabinets, the
lectrical placement is not critical. A grounded
e
electrical box should be located within 4'
(1.2 m) of the right rear of the cooktop.
For installation above an oven, unless you are
using cabinets deeper than 24" (610), it is
recommended that the electrical supply be
placed in the base cabinet to the right of the
oven.
INSTALLATION SPECIFICATIONS – MODEL CT15E
IMPORTANT NOTE:
Do not block the cooling
fan located at the bottom of the cooktop.
Overall Dimensions
MODEL CT15E
Overall Width15" (381)
Overall Height33/4" (96)
Overall Depth21" (533)
Minimum Cabinet Depth223/4" (578)
Minimum Height Clearance*
Cut-Out W
idth13
3
Cut-Out Depth191/4" (489)
*Minimum 53/4" (146) clearance is required
between countertop and any combustible
surface directly below the cooktop.
For detailed conduit dimensions, refer to
4" (102)
/8" (340)
Countertop Cut-Out
the illustration on page 5.
1
Dimensions may vary to
6
±
/8" (3).