Wolf Appliance Company CT15E User Manual

E LECTRIC C OOKTOPS
INSTALLATION INSTRUCTIONS
CONTACT INFORMATION
Wolf Customer Service: 800-332-9513
Website: wolfappliance.com
As you follow these instructions, you will notice WARNING and CAUTION symbols. This blocked information is important for the safe and efficient installation of Wolf equip­ment. There are two types of potential hazards that may occur during installation.
WOLF®is a registered trademark of Wolf Appliance, Inc.
signals a situation where minor injury or product damage may occur if you do not follow instr
states a hazard that may cause serious injury or death if precautions are not followed.
uctions.
WOLF ELECTRIC COOKTOPS
CLEAR
O
S
IM
HIGH
OF
F
ON
OFF
ON
S
I
M
HI
G
H
OFF
ON
SI
M
HI
GH
B
RI
DGE
ZON
E
2 ZON
E
3
HIGH
M
EL
T
OFF
ON
INSTALLATION REQUIREMENTS
IMPORTANT NOTE:
Save these Installation
Instructions for the local inspector’s use.
Please read the entire Installation Instruc-
ions prior to installation.
t This installation must be completed by a
qualified technician.
Installer:
please retain these instructions for local inspector’s reference, then leave them with the homeowner.
Homeowner:
please read and keep these instructions for future reference and be sure to read the entire Use & Care Information prior to use.
IMPORTANT NOTE:
This appliance must be installed in accordance with National Electrical Codes, as well as all state, municipal and local codes. The correct voltage, frequency and amperage must be supplied to the appliance from a dedicated, grounded circuit which is protected by a properly sized circuit breaker or time delay fuse. The proper voltage, frequency, and power ratings are listed on the product rating plate.
Record the model and serial numbers before installing the cooktop. Both numbers are on the rating plate, located on the underside of the cooktop. Refer to the illustration below.
BEFORE YOU START
Proper installation is your responsibility. Have a qualified technician install this
ooktop. You must also assure that electri-
c cal installation is adequate and in compli­ance with all local codes and ordinances.
Installations and repairs must be performed
y a qualified or licensed contractor or
b electrician qualified or licensed by the state, province, or region where this appliance is being installed.
Make sure you have everything necessary for correct installation. It is the responsibil­ity of the installer to comply with the installation clearances specified in this book and on the product rating plate. The rating plate is located on the underside of the cooktop. Refer to the illustration below.
Electrical ground is required; see Electrical Requirements on page 14.
Warranty service must be preformed by a Wolf authorized service center.
This cooktop is intended for indoor use.
RATING PLATE INFORMATION
Model Number
Serial Number
Location of rating
plate under cooktop
Rating plate location
3
WOLF ELECTRIC COOKTOPS
C
G
D
A
B
B
E
F
SITE PREPARATION
IMPORTANT NOTE:
Installation of the Wolf
electric cooktop must meet the following
ocation requirements. All dimensions listed
l are minimum requirements for safe operation. Refer to the illustration below.
To eliminate the risk of burns or fire by reaching over heated surface units, cabinet storage space located above the surface units should be avoided. If cabinet storage is to be pr can be reduced by installing a ventilation hood that projects horizontally a minimum of 5" (127) beyond the bottom cabinets.
ovided, the risk
LOCATION IN COUNTERTOP
inimum flat countertop surface. Must be
A)M
equal to or greater than cooktop width.
B)
Minimum 1" (25) wide clearance from the cooktop side edge to any combustible surface up to 18" (457) above the cooktop (noted by shaded area).
OVERHEAD CABINET DIMENSIONS
C)
Minimum spacing between overhead side cabinets must be greater than or equal to the nominal width of the cooktop unit(s).
D)
Minimum 18" (457) vertical distance from the countertop to the bottom of side cabinets within minimum side clearance.
E)
Minimum vertical distance between the countertop and combustible materials above the cooktop must be 30" (762).
F)
Minimum 1" (25) from rear wall.
G)
Maximum 13" (330) depth of overhead and side cabinets directly above and within side clearance.
Minimum clearances for installation
4
Failure to locate the cooktop unit without the proper clearances will result in a fire hazard.
INSTALLATION INSTRUCTIONS
11/4" (32)
2"
(51)
2"
(51)
INSTALLATION SPECIFICATIONS
The illustrations on pages 6–11 provide the overall dimensions, installation specifications
nd countertop cut-out for each of the Wolf
a electric cooktop models.
These cooktops are designed to fit a standard 24" (610) deep base cabinet with a 25" (635)
eep countertop. Before making the counter-
d top cut-out, verify that the cooktop will clear the side walls of the base cabinet below.
Clearance is required for the conduit located at the right rear of the cooktop. Refer to the illus­tration below for dimensions.
FRAMED ELECTRIC COOKTOPS
For framed models, a minimum 53/4" (146) clearance is required between the countertop and any combustible surface directly below the cooktop.
Wolf framed electric cooktops are designed to be installed in combination with other cooktop units.
IMPORTANT NOTE:
When multiple cooktop units are installed side by side, refer to the countertop cut-out dimensions on page 9.
UNFRAMED ELECTRIC COOKTOPS
For unframed models, a minimum 61/4" (159) clearance is required between the countertop
nd any combustible surface directly below
a the cooktop.
IMPORTANT NOTE:
Unframed electric cooktops are not designed to be installed in combination with other cooktops.
IMPORTANT NOTE:
Unframed electric cooktops cannot be installed with a downdraft ventilation system.
For installation options of the unframed electric cooktops, refer to Unframed Installa­tions on pages 12–13.
Wolf framed electric cooktops can accommo­date a Wolf downdraft ventilation system. Refer to installation instructions provided with the downdraft for additional specifications.
Conduit dimensions
Dimensions in parentheses are in millimeters unless otherwise specified.
5
E
4" (102)
15"
(381)
15"
(381)
2"*min (51)
CUT-OUT TO
COMBUSTIBLE
MATERIALS
(BOTH SIDES)
133/8" (340)
COOKTOP CUT-OUT
WIDTH
133/8" (
340)
COOKTOP CUT-OUT
WIDTH
33" (838)
RECOMMENDED
CABINET WIDTH
18"
(457)
NOTE: Application shown allows for installation of two 15" (381) modules side-by-side with 33" (838) recommended cabinet width. 18" (457) recommended cabinet width for installation of single 15" (381) cooktop or module. *Minimum clearance from both side edges of cooktop cut-out to combustible materials up to 18" (457) above countertop. **Minimum clearance from rear edge of cooktop cut-out to combustible materials up to 18" (457) above countertop.
191/4" (489)
COOKTOP CUT-OUT
DEPTH
21/2"min
(64)
36" (914)
STANDARD
FLOOR TO
COUNTERTOP
HEIGHT
13" max
(330)
30" (762)
COUNTERTOP TO
COMBUSTIBLE
MATERIALS
ABOVE COOKTOP
FRONT OF COUNTERTOP
21/2"min
(64)
191/4" (489)
COOKTOP
CUT-OUT DEPTH
2"**
(
51)
21"
(533)
OVERALL
DEPTH
15" (381)
OVERALL WIDTH
5" (127)33/4" (96)
CONDUIT
WOLF ELECTRIC COOKTOPS
FRAMED
MODEL CT15E
The illustrations below provide installation specifications for Model CT15E.
If Model CT15E is installed above cabinets, the
lectrical placement is not critical. A grounded
e electrical box should be located within 4' (1.2 m) of the right rear of the cooktop.
For installation above an oven, unless you are using cabinets deeper than 24" (610), it is recommended that the electrical supply be placed in the base cabinet to the right of the oven.
INSTALLATION SPECIFICATIONS – MODEL CT15E
IMPORTANT NOTE:
Do not block the cooling
fan located at the bottom of the cooktop.
Overall Dimensions
MODEL CT15E
Overall Width 15" (381)
Overall Height 33/4" (96)
Overall Depth 21" (533)
Minimum Cabinet Depth 223/4" (578)
Minimum Height Clearance*
Cut-Out W
idth 13
3
Cut-Out Depth 191/4" (489)
*Minimum 53/4" (146) clearance is required
between countertop and any combustible surface directly below the cooktop.
For detailed conduit dimensions, refer to
4" (102)
/8" (340)
Countertop Cut-Out
the illustration on page 5.
1
Dimensions may vary to
6
±
/8" (3).