INSTALLATION GUIDE
Pro Wall Ventilation Hoods
Contents
Important Note
Wolf Pro Wall Ventilation Hoods . . . . . . . . . . . . . . . . . . 3
Installation Considerations . . . . . . . . . . . . . . . . . . . . . . 4
Pro Wall Hood Specifications . . . . . . . . . . . . . . . . . . . . 5
Pro Wall Hood Installation . . . . . . . . . . . . . . . . . . . . . 10
Service Information . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Features and specifications are subject to change at any time without notice. Visit wolfappliance.com/specs for the most up-to-date information.
IMPORTANT NOTE: Throughout this guide, dimensions in parentheses are millimeters unless otherwise specified.
o ensure the safe and efficient use of Wolf equipment,
T please take note of the following types of highlighted information throughout this guide:
IMPORTANT NOTE highlights information that is especially important.
CAUTION signals a situation where minor injury or product damage may occur if instructions are not followed.
WARNING states a hazard that may cause serious injury or death if precautions are not followed.
Wolf Pro Wall Ventilation Hoods 3
wolfappliance.com/specs
Pro Wall Hood Installation
IMPORTANT NOTE: T
his installation must be completed by a qualified installer or Wolf authorized service center technician.
Read this entire installation guide prior to installation and save for the local inspector’s reference. The homeowner should keep this installation guide for future reference.
This appliance must be installed in accordance with National Electrical Codes, as well as all state, municipal and local codes. The correct voltage, frequency and amperage must be supplied to the appliance from a dedi­cated, grounded circuit which is protected by a properly sized circuit breaker or time delay fuse. The proper voltage, frequency, and amperage ratings are listed on the product rating plate.
Record the model and serial numbers before installing the ventilation hood. Both numbers are listed on the product rating plate, located inside the left wall of the hood shell. Refer to the illustration below.
olf Pro Wall Hood
W
Model Number
Serial Number
RATING PLATE (INSIDE HOOD)
Location of rating plate.
Installation Considerations 4
IMPORTANT INSTRUCTIONS
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY, OBSERVE THE FOLLOWING:
Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
Two installers are recommended due to the size and weight of the pro ventilation hood.
Install the pro ventilation hood only with a blower manufactured by Wolf.
When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
Ducted fans must always be vented to the outdoors.
To reduce the risk of fire and properly exhaust air, be certain to duct air outside. Do not vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces or garages.
Installation Considerations
ro wall hoods are recommended for use with all Wolf
P cooking appliances and should be at least as wide as the cooking surface. The ventilation hood be installed 30" (762) to 36" (914) above the countertop.
IMPORTANT NOTE: For optimal performance in wall hood
applications, a pro 27" (686) deep wall hood is recom­mended for use with ranges and rangetops that contain a charbroiler or griddle.
BLOWER ASSEMBLIES
Pro ventilation hoods are shipped without the blower assembly. Internal, in-line and remote blowers are avail­able through your authorized Wolf dealer. For local dealer information, visit the find a showroom section of our website, wolfappliance.com.
The blower will vary in size and is dictated by the cooking surface, the volume of air that needs to be moved and the length of the duct run. Refer to ventilation recommenda­tions in the Wolf design guide.
IMPORTANT NOTE: Use only a Wolf blower with the pro
ventilation hood.
Pro Wall Hood Specifications 5
30" (762), 36" (914), 42"(1067)
AND 48" (1219) WIDTHS
1
0"
(
254)
O
VERALL
HEIGHT
4" (
102)
22" (559)
OVERALL DEPTH
1
2"
(305)
30" (762), 36" (914), 42"(1067), 48" (1219)
54" (1372), 60" (1524) AND 66"(1676) WIDTHS
18" (
457)
OVERALL
HEIGHT
4" (
102)
24" (610)
OVERALL DEPTH
12"
(305)
30" (762), 36" (914), 42"(1067), 48" (1219)
54" (1372), 60" (1524) AND 66"(1676) WIDTHS
27" (686)
OVERALL DEPTH
12"
(305)
18" (457)
OVERALL
HEIGHT
4" (102)
wolfappliance.com/specs
Overall Dimensions
LOW-PROFILE WALL HOODS
24" (610) DEEP WALL HOODS
27" (686) DEEP WALL HOODS
Pro Wall Hood Specifications 6
E
6
"
(152)
5
"
(127)
L
OCATION OF ELECTRICAL
WIDTH OF HOOD
30" (762) TO 36" (914)
T
O COUNTERTOP
1
0"
(254)
HEIGHT
OF HOOD
22" (559)
DEPTH OF HOOD
E
6"
(152)
5"
(127)
LOCATION OF ELECTRICAL
WIDTH OF HOOD
30" (762) TO 36" (914)
TO COUNTERTOP
18" (457)
HEIGHT
OF HOOD
24" (610) OR
27" (686)
DEPTH OF HOOD
Installation Specifications
LOW-PROFILE WALL HOODS
24" AND 27" DEEP WALL HOODS
Pro Wall Hood Specifications 7
wolfappliance.com/specs
Electrical Requirements
olf pro ventilation hoods require a separate, grounded
W 120 V AC, 60 Hz power supply. The service should have its own 15 amp circuit breaker. Locate the electrical supply flush with back wall and within the shaded area shown in the illustration for your specific model on the previous page.
IMPORTANT NOTE: You must follow all National Electrical
Code regulations. In addition, be aware of local codes and ordinances when installing your service.
Electrical service for the ventilation hood must be installed by a qualified electrician in accordance with all applicable national and local electrical codes.
Installation Options
HORIZONTAL DISCHARGE
Pro low-profile wall hoods have an adjustable discharge. Pro 24" (610) and 27" (686) deep wall hoods have a vertical discharge. A horizontal discharge kit is available through your authorized Wolf dealer. For local dealer infor­mation, visit the find a showroom section of our website, wolfappliance.com.
RECIRCULATING INSTALLATION
Pro wall hoods, 30" (762) and 36" (914) wide, with an internal blower (600 CFM or less), can be used in a non­ducted application with a recirculating filter. In this installa­tion, kitchen air is purified through filters and returned as clean air into the room. A recirculation kit available through your authorized Wolf dealer is required. For local dealer information, visit the find a showroom section of our website, wolfappliance.com.
DUCT COVER
Optional stainless steel duct covers are available in a variety of heights for all pro ventilation hoods through your authorized Wolf dealer. For local dealer information, visit the find a showroom section of our website, wolfappliance.com.
BACKSPLASH
Optional stainless steel backsplashes are available in widths to match all pro wall hoods through your authorized Wolf dealer. For local dealer information, visit the find a showroom section of our website, wolfappliance.com.
Pro Wall Hood Specifications 8
A
TO
CENTER OF
TRANSITION
11/2" (38)
2" (51)
TO CENTER
OF TRANSITION
9"
(229)
55/8" (143)
TO CENTER
OF TRANSITION
A
TO
CENTER OF
TRANSITION
11/2" (38)
25/8" (60)
TO CENTER
OF TRANSITION
A
TO
CENTER OF
TRANSITION
DISCHARGE
CUT-OUT
3
1
/4
"
(83)
14"
(356)
Discharge Specifications
LOW-PROFILE WALL HOODS
The illustrations provide dimensions for discharge options for low-profile wall hoods. These dimensions are critical for proper installation. Dimension A in the illustrations will vary with the width of the hood. Refer to the chart below.
IMPORTANT NOTE: The transition included with the 500
CFM internal blower accommodates 3 ductwork. An optional 3
1
/4" (83) x 10" (254) to 8" (203)
1
/4" (83) x 10" (254)
round transition is available through your authorized Wolf dealer. For local dealer information, visit the find a showroom section of our website, wolfappliance.com.
Low-Profile Wall Hoods
WIDT H OF HOOD A
30" (762) 143/4" (375) 36" (914) 173/4" (451) 42" (1067)* 203/4" (527) 48" (1219)* 233/4" (603)
*500 CFM blower not available for these hood widths.
LOW-PROFILE WALL HOODS DISCHARGE OPTIONS
Vertical discharge.
Cut-out without transition.
Horizontal discharge.
Vertical discharge with accessory transition.