Wolf SRT362WLP Installation manual

SEALED BURNER RANGETOP
INSTALLATION GUIDE
SPECIFICATIONS, INSTALLATION, AND MORE
SEALED BURNER RANGETOP
Contents
3 Specications
6 Installation
Features and specications are subject to change at any time without notice. Visit wolfappliance.com/specs for the most up-to-date information.
Important Note
To ensure this product is installed and operated as safely and efciently as possible, take note of the following types of highlighted information throughout this guide:
IMPORTANT NOTE highlights information that is especially
important.
CAUTION indicates a situation where minor injury or product
damage may occur if instructions are not followed.
WARNING states a hazard that may cause serious injury or
death if precautions are not followed.
IMPORTANT NOTE: Throughout this guide, dimensions in
parentheses are millimeters unless otherwise specied.
IMPORTANT NOTE: Save these instructions for the local
electrical inspector.
2 | Wolf Customer Care 800.222.7820
SPECIFICATIONS
Product Information
Important product information, including the model and serial number, are listed on the product rating plate. The rating plate is located on the bottom of the control panel, at the far right. Refer to the illustration below.
If service is necessary, contact Wolf Factory Certied Service with the model and serial number. For the name of the nearest Wolf Factory Certied Service or for questions regarding the installation, visit the Support & Service section of our website, wolfappliance.com, or call Wolf Customer Care at 800-222-7820.
RATING PLATE
Rating plate location
Planning Information
When installing against a combustible surface, a minimum
(127) riser is required for model SRT366, and a minimum
5"
(254) riser is required for 36" and 48" sealed burner
10" rangetops with a charbroiler or griddle. Follow all minimum clearances to combustible surfaces shown in the illustra­tion on page 5. Models SRT362W and SRT484W cannot be installed against a combustible surface.
Electrical Requirements
Installation must comply with all applicable electrical codes.
Locate the electrical supply within the shaded area shown in the illustration on page 5. A separate circuit servicing only this appliance is required. A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation.
ELECTRICAL REQUIREMENTS
Electrical Supply grounded, 110/120 VAC, 60 Hz Service 15 amp dedicated circuit Receptacle 3-prong grounding-type Power Cord 6'
(1.8 m)
wolfappliance.com | 3
SPECIFICATIONS
Gas Supply
Installation must comply with local codes or, in the absence of local codes, with the National Fuel Gas Code.
Locate the gas supply within the shaded area shown in the illustration on the following page.
The rangetop is equipped for use with natural or liquid propane (LP) gas. It is design certied by the Canadian Standards Association (CSA) for natural or LP gases. The product rating plate has information on the type of gas that should be used. For rating plate location, refer to the illustra­tion below. If this information does not agree with the type of gas available, check with the local gas supplier. The gas pressure regulator is built into the unit.
GAS REQUIREMENTS
NATURAL GAS WC
Supply Pressure 5" (12.5 mb) Min Line Pressure 7" (17.5 mb) Max Regulator Pressure 14" (34.9 mb), .5 psi (3.5 kPa)
LP GAS WC
Supply Pressure 10" (25 mb) Min Line Pressure 11" (27.4 mb) Max Regulator Pressure 14" (34.9 mb), .5 psi (3.5 kPa)
The rangetop must be connected to a regulated gas supply. The supply line must be equipped with an approved external gas shut-off valve located near the rangetop in an acces­sible location. Do not block access to the shut-off valve. Refer to the illustration below.
3
A gas supply of rangetop. If local codes permit, a certied, 3'
1
/2" (13) or 3/4" (19) ID exible metal appliance connector is
recommended to connect the units
/4" (19) ID line must be provided to the
(.9 m) long,
1
/2" NPT female inlet to the gas supply line. Pipe joint compounds suitable for use with natural or LP gas should be used.
The appliance and its shut-off valve must be disconnected from the gas supply piping system during any pressure testing of the system at test pressures in excess of .5 psi
(3.5 kPa)
. The appliance must be isolated from the gas supply piping system by closing its individual manual shut­off valve during any pressure testing of the system at test pressures equal to or less than .5 psi
Wolf natural gas rangetops will function up to 10,250'
(3124 m)
getops up to 8,600'
in altitude without adjustment and LP gas ran-
(2621 m). If the installation exceeds
(3.5 kPa).
these elevations, contact your authorized Wolf dealer for a high altitude conversion kit.
RATING PLATE
Rating plate location
4 | Wolf Customer Care 800.222.7820
SHUT-OFF VALVE
OPEN POSITION
Gas shut-off valve
GAS SUPPLYTO APPLIANCE
SPECIFICATIONS
SIDE
*W
NO combus El Fo
Sealed Burner Rangetop
INSTALLATION
13"
(330)
24" (610) MAX
PLATFORM
71/2" (191)
OPENING
HEIGHT
18"
(457)
6"
(152)
OPENING WIDTH
PLATFORM
30" (762) TO 36" (914)
TO BOTTOM OF
VENTILATION HOOD*
W
PLATFORM
TOP VIEW
4"
(102)
BACK WALL
E G
16" (406)
ELECTRICAL
AND GAS
VIEW
ithout ventilation hood, 36" (914) minimum clearance countertop to combustible materials, 44" (1118) for charbroiler.
TE: Shaded area above countertop indicates minimum clearance to combustible surfaces,
tible materials cannot be located within this area.
ectrical and gas supply located through bottom of platform.
r island installation, 12" (305) minimum clearance back of rangetop to combustible rear wall above countertop.
OPENING WIDTH
FRONT VIEW
W
30" Model 30" (762) 36" Model 36" (914) 48" Model 48" (1219)
wolfappliance.com | 5
INSTALLATION
Preparation
Prepare the nished opening for the rangetop according to dimensions shown in the illustration on the previous page. The platform must include a cutout at the right rear for the electrical and gas supply connections. It must be level to ensure the cooking surface is level. Refer to the chart below for the minimum base support.
INSTALLATION REQUIREMENTS
PLATFORM
Thickness
BASE SUPPORT MIN
30" Rangetop 200 lb (91 kg) 36" Rangetop 250 lb (113 kg) 48" Rangetop 300 lb (136 kg)
3
/4" (19)
Placement
Use an appliance dolly to move the unit near the opening. Remove and recycle packing materials.
If a riser has been specied, refer to the installation instruc­tions packaged with the riser. The riser must be installed before the rangetop is installed.
Place the unit into the opening. Connect the gas and elec­trical supply. The connections may need to be made prior to nal placement.
For wok models, install the wok plate notch toward the front of the unit. Refer to the illustration below.
NOTCH
Wok plate notch
6 | Wolf Customer Care 800.222.7820
INSTALLATION
Gas Supply Connection
All connections to the gas piping must be wrench-tightened. Do not overtighten or allow pipes to turn when tightening.
If a exible metal connector is used, verify it is not kinked, then attach the gas supply line to the regulator on the rangetop. Open the valve and check for leaks by placing a liquid detergent solution onto all gas connections. Bubbles around the connections indicate a gas leak. If a leak appears, close the shut-off valve and adjust the connections.
Troubleshooting
IMPORTANT NOTE: If the rangetop does not operate prop-
erly, follow these troubleshooting steps:
Verify electrical power is supplied to the rangetop.
Verify the gas supply shut-off valve is in the open
position.
If the rangetop does not operate properly, contact Wolf
Factory Certied Service. Do not attempt to repair the rangetop. Wolf is not responsible for service required to correct a faulty installation.
Sub-Zero, Sub-Zero & Design, Sub-Zero & Snowake Design, Dual Refrigeration, The Living Kitchen, Great American Kitchens The Fine Art of Kitchen Design, Wolf, Wolf & Design, Wolf Gourmet, W & Design, red colored knobs, Cove, and Cove & Design are registered trademarks and service marks of Sub-Zero Group, Inc. and its subsidiaries. All other trademarks are property of their respective owners in the United States and other countries.
wolfappliance.com | 7
ESTUFA CON QUEMADORES SELLADOS
Contenido
3 Especicaciones
6 Instalación
7 Resolución de problemas
Las características y especicaciones están sujetas a cam­bios sin previo aviso. Visite wolfappliance.com/specs para obtener la información más actualizada.
Aviso importante
Para garantizar que este producto se instale y opere de la forma más segura y eciente posible, tome nota de los siguientes tipos de información resaltada en esta guía:
AVISO IMPORTANTE señala la información que es especial-
mente importante.
PRECAUCIÓN indica una situación en la que se pueden
sufrir heridas leves o provocar daños al producto si no se siguen las instrucciones.
ADVERTENCIA indica peligro de que se produzcan heridas
graves o incluso la muerte si no se siguen las precauciones.
AVISO IMPORTANTE: en toda esta guía, las dimensiones
entre paréntesis son milímetros, a menos que se especi­que lo contrario.
AVISO IMPORTANTE: guarde estas instrucciones para el
inspector eléctrico local.
2 | Atención al cliente de Wolf 800.222.78200
Loading...
+ 18 hidden pages