Features and specifications are subject to change at any time
without notice. Visit wolfappliance.com/specs for the most
up-to-date information.
IMPORTANT NOTE: Throughout this guide, dimensions in
parentheses are millimeters unless otherwise specified.
o ensure the safe and efficient use of Wolf equipment,
T
please take note of the following types of highlighted
information throughout this guide:
IMPORTANT NOTE highlights information that is
especially important.
CAUTION signals a situation where minor injury or product
damage may occur if instructions are not followed.
WARNING states a hazard that may cause serious injury or
death if precautions are not followed.
Wolf Dual Fuel Ranges3
wolfappliance.com/specs
Dual Fuel Range Installation
IMPORTANT NOTE: T
his installation must be completed
by a qualified installer, service agency or gas supplier.
Read this entire installation guide prior to installation and
save for the local inspector’s reference. The homeowner
should keep this installation guide for future reference.
This appliance must be installed in accordance with
National Electrical Codes, as well as all state, municipal
and local codes. The correct voltage, frequency and
amperage must be supplied to the appliance from a dedicated, grounded circuit which is protected by a properly
sized circuit breaker or time delay fuse. The proper
voltage, frequency, and amperage ratings are listed on
the product rating plate.
Wolf dual fuel ranges are manufactured for use with
natural gas or LP gas. Check the product rating plate for
the type of gas for your specific model. If this appliance
does not correspond to your type of gas, contact your
authorized Wolf dealer.
Record the model and serial numbers before installing the
dual fuel range. Both numbers are listed on the product
rating plate, located on the bottom of the control panel
assembly, at the far right, just above the oven door. Refer
to the illustration below.
olf Dual Fuel Range
W
Model Number
Serial Number
RATING PLATE
Location of rating plate.
Safety Instructions4
IMPORTANT INSTRUCTIONS
WHAT TO DO IF YOU SMELL GAS:
•
If the information in this guide is not followed
exactly, a fire or explosion may result, causing
property damage, personal injury or death.
•
Installation and service must be performed by a
qualified installer, service agency or the gas supplier.
•
Warranty service must be performed by a Wolf
authorized service center.
•
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
•
All openings in the wall or floor where the range is to
be installed must be sealed.
Do not try to light any appliance.
•
Do not touch any electrical switch.
•
Do not use any phone in your building.
•
Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
•
If you cannot reach your gas supplier, call the fire
department.
This range can tip. Injury to persons could result.
Install the anti-tip device provided with this range
according to instructions on page 14.
•
A ventilation hood is recommended for use with the
Wolf dual fuel range.
•
In Massachusetts: Installations and repairs must be
performed by a qualified or licensed contractor,
plumber or gasfitter qualified or licensed by the
state, province, or region where this appliance is
being installed. Only use gas shut-off valves
approved for use within the state, province, or region
where this appliance is being installed. A flexible gas
connector, when used, must not exceed 3' (.9 m).
Dual Fuel Range Specifications5
297/8" (759)
3
6
7
/8"
(937)
HEIGHT TO
COOKING
SURFACE*
357/8" (911)
3
6
7
/8"
(937)
HEIGHT TO
COOKING
SURFACE*
477/8" (1216)
367/8"
(
937)
HEIGHT TO
COOKING
SURFACE*
601/8" (1527)
407/8"
(1035)
5"
RISER
457/8"
(1165)
10"
RISER
557/8"
(1419)
20"
RISER
47" (1194)
261/8" (664)
25" (635)
241/8" (613)
271/2" (699)
91/4"
(235)
291/2" (749)
*LEGS AND CASTERS ALLOW FOR
HEIGHT ADJUSTMENT UP TO 39"(991)
357/8"
(911)
367/8"
(937)
HEIGHT TO
COOKING
SURFACE*
wolfappliance.com/specs
Dual Fuel Range Dimensions
30" (762) RANGE
60" (1527) RANGE
36" (914) RANGE48" (1219) RANGE
SIDE VIEW—ALL RANGES
Dual Fuel Range Specifications6
Installation Requirements
VENTILATION
Failure to locate the range without the proper clearances will result in a fire hazard.
IMPORTANT NOTE: Caution must be used in planning the
proper installation of the Wolf dual fuel range to avoid fires
or damage to adjacent cabinetry or kitchen equipment.
Follow all minimum clearances to combustible surfaces
shown in the installation illustration for your specific model
on the following pages.
IMPORTANT NOTE: When installing against a combustible
surface, a minimum 10" (254) riser is required for a 36"
(914) dual fuel range with charbroiler or griddle and all
48" (1219) and 60" (1524) models.
Risers and other accessories are available through your
authorized Wolf dealer. To obtain local dealer information,
visit the find a showroom section of our website,
wolfappliance.com.
The dual fuel range must have an adequate supply of fresh
air to assure proper combustion and ventilation. The
location of the range should be away from strong draft
areas, such as windows, doors and strong heating vents
or fans. Do not obstruct the flow of air.
Due to the high volume of ventilation air required, a source
of outside replacement air is recommended. This is especially important for tightly sealed and insulated homes. A
qualified HVAC contractor should be consulted.
It is recommended that you use a Wolf pro ventilation
hood or hood liner with the dual fuel range. If the range is
to be installed without ventilation, a 36" (914) minimum
clearance, 44" (1118) for charbroiler, from countertop to
combustible materials above the range is required. Refer
to the installation illustrations on pages 10–13.