Powerful multi-speed blowers draw odors and smoke
into the five-layer mesh filter. Filters remove easily for cleaning. The sculpted classic stainless steel shape not only provides the power you expect from Wolf, but also the beauty you have come to appreciate as well.
This wall mount cooktop hood is 36" (914) wide by 21" (533) deep. It has a telescopic chimney flue that allows you to reach a ceiling height of 8' (2.4 m) to 9' (2.7 m) with a finished look. A flue extension to accommodate 10' (3 m) ceilings is available as a sales accessory.
Wolf cooktop wall hoods are recommended for use with Wolf electric and gas cooktops and integrated modules. For Wolf dual fuel ranges, gas ranges, sealed burner rangetops and gas rangetops, a Pro ventilation hood should be used.
Model CTWH36
Wolf cooktop wall ventilation hoods are available in the classic stainless steel finish. Cooktop wall hoods are sold as a shell only, internal, in-line and remote blower options are available.
Classic stainless steel finish
Aluminum mesh filter
Front mounted controls
Rating plate location
Three-speed blower control
Seamless Construction
Transition with backdraft damper
LED indicators
Halogen lighting
Page 2
Planning Information
Model CTWH36 Cooktop Wall Hood
Dimensions in parentheses are in millimeters unless otherwise specified.
Dimensions may vary by ±
1
/8" (3).
2
OVERALL DIMENSIONS
FEATURES
Classic stainless steel finish
Internal, in-line and remote blower options
Front mounted controls with LED indicator
Heavy-duty stainless steel seamless
construction
Three-speed blower control
Variable speed blowers
Filter clean timer lets you know when the
filter needs cleaning
Delay-off mode automatically turns unit off
Sealed halogen lighting with three settings
Stainless steel filter cover with dishwasher safe aluminum mesh filter
Heat sentry feature automatically turns unit on when heat is sensed and automatically adjusts blower speed
Transition with backdraft damper included
Fits 8' (2.4 m) to 9' (2.7 m) ceilings – flue extension to accommodate 10’ (3 m) ceilings is available as a sales accessory
UL listed to US and Canadian safety standards
Two and five year residential warranty – exclusions apply; warranty information can be found on our website, wolfappliance.com
18"
(457)
3211/16" TO 507/8"
(830 – 1292)
OVERALL HEIGHT
811/16"
(221)
357/16"
OVERALL WIDTH
(900)
12"
(305)
21"
(533)
OVERALL DEPTH
45/16"
(110)
191/8"
(486)
19/16"
(40)
min
91/4"
(235)
Page 3
Planning Information
Model CTWH36 Cooktop Wall Hood
Dimensions in parentheses are in millimeters unless otherwise specified.
3
SPECIFICATIONS
Overall Width 357/16" (900)
Overall Height (excluding chimney) 91/4" (235)
Overall Height (including chimney) 3211/16" (830)
Maximum Height (full extension) 507/8" (1292)
Overall Depth 21" (533)
Transition 8" (203) to 10" (254) round
Duct Size 8" (203) round
Discharge Vertical
Electrical Supply Requirements 110 /120 V AC, 60 Hz
15 amp dedicated circuit
Shipping Weight 100 lbs (45 kg)
Specifications are subject to change without notice.
BLOWER OPTIONS
600 CFM Internal Blower 801644
900 CFM Internal Blower 801645
600 CFM In-Line Blower 808331
1100 CFM In-Line Blower 808332
600 CFM Remote Blower 801640
900 CFM Remote Blower 801641
1200 CFM Remote Blower 801642
1500 CFM Remote Blower 804701
Model CTWH36 is sold as a shell only, an internal, in-line or remote blower will be required. Refer to Wolf Cooktop Ventilation Recommendations at the end of this section.
ACCESSORIES
36" (914) wall shield
Flue extension to accommodate
10' (3 m) ceilings
8" (203) to 10" (254) round
transition
Accessories are available through your Wolf dealer. To obtain local dealer information, visit the Locator section of our website, wolfappliance.com.
Page 4
Planning Information
Model CTWH36 Cooktop Wall Hood
Dimensions in parentheses are in millimeters unless otherwise specified.
4
DIMENSIONS
Overall Width of Hood 357/16" (900)
Floor to Ceiling Height 8' (2.4 m) to 9' (2.7 m)
Countertop to Bottom of Hood 24" (610) to 30" (762)
Minimum Height of Hood (fully collapsed) 3211/16" (830)
Maximum Height of Hood (full extension) 507/8" (1292)
Location of Electrical Within shaded area
See Installation Instructions shipped with unit for detailed specifications.
21"
(533)
507/8"
(1292)
MAXIMUM
HEIGHT OF HOOD
(2.4 m – 2.7 m)
CEILING HEIGHT
8' TO 9'
FLOOR TO
4"(102)
24" TO 30"
(610 – 762)
TO COUNTERTOP
6"
(152)
E
357/16"
(900)
3211/16"
(830)
MINIMUM
HEIGHT OF HOOD
*8' (2.4 m) ceilings will not allow for a 30" (762) maximum height above the countertop. Based on a 36" (914) high countertop, an 8' (2.4 m) ceiling will allow for a maximum height above the countertop of 27
5
/16" (694).
Page 5
Planning Information
Model CTWH36 Cooktop Wall Hood
Dimensions in parentheses are in millimeters unless otherwise specified.
5
INSTALLATION NOTES
Refer to the illustrations and specifications for overall dimensions and installation specifics.
Wolf cooktop wall hoods are recommended for use with Wolf electric and gas cooktops and integrated modules. The hood should be at least as wide as the cooking surface.
IMPORTANT NOTE: Wolf Pro ventilation hoods should be used with Wolf dual fuel ranges, gas ranges, sealed burner rangetops and gas range­tops.
Wolf cooktop wall hoods come with a telescopic chimney flue that allows you to reach a ceiling height of 8' (2.4 m) to 9' (2.7 m) with a finished look. A flue extension to accommodate 10' (3 m) ceilings is available as a sales accessory.
Installation of the cooktop wall hood should be 24" (610) to 30" (762) from the bottom of the hood to the countertop. Follow the dimen­sions shown in the Installation illustration.
IMPORTANT NOTE: 8' (2.4 m) ceilings will not allow for a 30" (762) maximum height above the countertop. Based on a 36" (914) high countertop, an 8' (2.4 m) ceiling will allow for a maximum height above the countertop of 27
5
/16" (694).
Wolf cooktop wall hoods are shipped without a blower assembly. Internal, in-line and remote blower assemblies are available. Blower options also vary with the volume of air that needs to be moved and the length of the duct run. Refer to the charts at the end of this section for ventilation recommendations and blower options.
IMPORTANT NOTE: Install this ventilation hood only with a Wolf blower.
Wolf cooktop wall hoods require a separate, grounded 110/ 120 V AC, 60 Hz power supply. The service should have its own 15 amp circuit breaker. Placement of the outlet is not critical, as long as you provide a minimum of 12" (305) of 120 V AC, 60 Hz power cable. Locate electrical within the shaded area shown in the Installation illustration.
You must follow all National Electrical Code regulations. In addition, be aware of local codes and ordinances when installing your service.
Wolf cooktop wall hoods have an 8" (203) round vertical discharge.
Refer to the installation instructions shipped with each Wolf product for detailed specifica­tions. This information can also be found on our website, wolfappliance.com.
Page 6
Planning Information
Model CTWH36 Cooktop Wall Hood
6
Dimensions in parentheses are in millimeters unless otherwise specified.
COOKTOP HOOD PLACEMENT
Wolf cooktop wall ventilation hoods come with a telescopic chimney flue that allows you to reach a ceiling height of 8' (2.4 m) to 9' (2.7 m) with a finished look. A flue extension to accommo­date 10' (3 m) ceilings is available as a sales accessory.
Installation of the wall hood should be 24" (610) to 30" (762) from the bottom of the hood to the countertop.
IMPORTANT NOTE: 8' (2.4 m) ceilings will not allow for a 30" (762) maximum height above the countertop. Based on a 36" (914) high countertop, an 8' (2.4 m) ceiling will allow for a maximum height above the countertop of 27
5
/16" (694).
IMPORTANT NOTE: Both sections of the telescopic chimney flue must be installed in order for the chimney to be lifted for service.
To determine placement of the cooktop wall hood, you must calculate the height of the telescopic chimney flue. Refer to the illustration and chart below.
To calculate the height of the telescopic chimney flue:
1) First measure A (total kitchen height from finished floor to
finished ceiling height).
2) Next measure B (height from finished floor to countertop).
3) Then determine the minimum C value (distance from
countertop to bottom of hood). Refer to the chart for ceiling heights from 8' (2.4 m) to 9' (2.7 m). Dimension C must be greater than 24" (610) and less than 30" (762).
4) To determine the upper flue section height: E=A-(C+B+D).
IMPORTANT NOTE: If dimension E falls between 0" (0) and
1
/2" (13), you will need to modify the flue to affix to the flue attachment brackets. For ease of installation, Wolf recommends that dimension E be no less than
1
/2" (13).
MODEL CTWH36
(A) (B) (C) (D) (E) (F)
96" (2438) 36" (914) 24" (610) min 3211/16" (830) 35/16" (84) 507/8" (1292)
96" (2438) 36" (914) 275/16" (694) max 3211/16" (830) 0" 507/8" (1292)
108" (2743) 36" (914) 24" (610) min 3211/16" (830) 157/16" (392) 507/8" (1292)
108" (2743) 36" (914) 30" (762) max 3211/16" (830) 95/16" (237) 507/8" (1292)
Letters correspond to those in the illustration.
(A)
TOTAL
FLOOR TO
CEILING HEIGHT
(E) UPPER FLUE TOTAL
HEIGHT TO CEILING
(F)
MAXIMUM
HEIGHT OF
HOOD
OF HOOD TO
MINIMUM FLUE
EXTENSION
(C)
COUNTERTOP
TO BOTTOM
OF HOOD
(B)
FLOOR TO
COUNTERTOP
HEIGHT
(D)
BOTTOM
Page 7
Planning Information
Model CTWH36 Cooktop Wall Hood
7
Dimensions in parentheses are in millimeters unless otherwise specified.
DUCTING CONSIDERATIONS
Wolf cooktop wall hoods are shipped without the blower assembly. Internal, in-line or remote blower assemblies are available. For wall hoods, the remote blower can be mounted on the roof or an exterior wall.
IMPORTANT NOTE: Install these ventilation hoods only with a Wolf blower.
Wolf cooktop wall hoods have an 8" (203) round vertical discharge. Ducting for wall hoods can run through the roof or an external wall as shown in the illustration below.
Refer to the Cooktop ventilation charts at the end of this section for recommendations and blower options.
Ducting considerations cooktop wall hoods.
WALL CAP
OR REMOTE BLOWER
COOKTOP
WALL HOOD
DUCTWORK INSTALLATION
THROUGH ROOF
DUCTWORK INSTALLATION
THROUGH WALL
8" (203) ROUND
VERTICAL DISCHARGE
8" (203) ROUND DUCT
CHIMNEY FLUE EXTENSION
TELESCOPIC CHIMNEY FLUE
8" (203) ROUND ELBOW
8" (203) ROUND DUCT
67/8" (175) OR 91/4" (235)
21"
(535)
24" TO 30"
(610– 762)
COUNTERTOP
TO BOTTOM OF
VENTILATION HOOD
ROOF CAP OR REMOTE BLOWER –
TRANSITION FROM 8" (203) TO 10" (254) DUCT
REQUIRED FOR REMOTE BLOWER
Page 8
Planning Information
Wolf Ventilation Recommendations
Dimensions in parentheses are in millimeters unless otherwise specified.
8
Remote BLOWER-60REM and BLOWER-90REM
WOLF BLOWER ASSEMBLIES
A ventilation system must include a blower assembly. With a few exceptions where internal blowers are included, Wolf ventilation hoods and downdrafts are shipped without the blower assembly. An internal, in-line or remote blower assembly must be selected to accommodate the cooking appliance, CFM requirements and home­owner preferences. Internal, in-line and remote blower assemblies are available as sales acces­sories through your Wolf dealer.
Wolf internal, in-line and remote blowers are for use with Wolf cooktop hoods, downdraft systems and Pro ventilation hoods and hood liners.
IMPORTANT NOTE: Use only a Wolf blower with all Wolf ventilation products.
Internal blowers are mounted inside the hood canopy or downdraft blower box. In-line blowers are mounted in between the hood and the exterior of the home. Remote blowers can be mounted on the roof or in some cases, on an exterior wall. Refer to the illustrations below for dimensions of Wolf in-line and remote blowers.
Ventilation recommendation charts on the following pages provide minimum CFM recom­mendations according to the cooking appliance and ventilation system used and blower options for each specific ventilation hood or downdraft.
Remote BLOWER-120REM Remote BLOWER-150REM
In-line BLOWER-60IL In-line BLOWER-110IL
Dimensions may vary by ±1/8" (3).
243/8"
(619)
113/4"
(298)
181/2"
(470)
211/2"
(546)
41/2"
(114)
121/4"
(311)
18"
(457)
12"
(305)
22"
(559)
8"
(203)
7
24
"
/8
(632)
18"
(457)
3
/4
20
"
28
(718)
1
/4
15
"
(394)
1
"
/2
14"
(356)
10" (254)
Diameter
3
24
/4
(629)
(527)
1
24
"
/2
(622)
3
4
"
/4
"
(121)
1
/2
29
"
(749)
14
(375)
10" (254)
Diameter
3
"
/4
1
10
"
/8
(257)
22"
(559)
18" (457)
10"
(254)
29
(749)
7
(184)
21" (533)
10"
1
29
"
/2
(749)
1
"
/2
1
"
/4
14
(375)
10" (254)
Diameter
3
"
/4
3
10
"
/8
(264)
25"
(635)
(254)
29
(749)
7
(184)
1
"
/2
1
"
/4
Page 9
Planning Information
Wolf Cooktop Ventilation Recommendations
9
Dimensions in parentheses are in millimeters unless otherwise specified.
COOKTOP VENTILATION CFM RECOMMENDATIONS
Cooktop Hoods, Downdrafts and Pro Hoods
CTWH30 CTWH36 IH4227 DD30 DD36 DD45 Pro Hoods
Electric Cooktops
Model CT15E 215* 215* 215* 215* 150* 215*
Model CT30E 450 600 600 500 350 600
Model CT30EU 450 600 600 600
Model CT36E 600 600 500 600
Model CT36EU 600 600 600
CTWH30 CTWH36 IH4227 DD30 DD36 DD45 Pro Hoods
Gas Cooktops
Model CT15G 215* 215* 215* 215* 150* 215*
Model CT30G 450 600 600 500 350 600
Model CT36G 600 600 500 600
CTWH30 CTWH36 IH4227 DD30 DD36 DD45 Pro Hoods
Modules
Model CT15I 215* 215* 215* 215* 150* 215*
Model IG15 215* 215* 215* 215*
Model IS15 215* 215* 215* 215*
Model IF15 215* 215* 215* 215*
Model IM15 215* 215* 215* 215* 150* 215*
*Use these requirements to determine total CFM when installing multiple cooktops or modules.
CFM recommendations are based on total Btu/hr output. Wolf recommends 1 CFM per 100 Btu/hr (.03 kW). Additional CFM may be required for long duct runs.
COOKTOP VENTILATION BLOWER OPTIONS
Cooktop Ventilation Hoods
Blower Description Blower Number Cooktop Hood Models
450 CFM Internal CTBLOWER-45INT (801643) CTWH30
600 CFM Internal CTBLOWER-60INT (801644) CTWH36 / IH4227
900 CFM Internal CTBLOWER-90INT (801645) CTWH36 / IH4227
600 CFM In-Line BLOWER-60IL (808331) CTWH30 / CTWH36 / IH4227
1100 CFM In-Line BLOWER-110IL (808332) CTWH30 / CTWH36 / IH4227
600 CFM Remote BLOWER-60REM (801640) CTWH30 / CTWH36 / IH4227
900 CFM Remote BLOWER-90REM (801641) CTWH30 / CTWH36 / IH4227
1200 CFM Remote BLOWER-120REM (801642) CTWH30 / CTWH36 / IH4227
1500 CFM Remote BLOWER-150REM (804701) CTWH30 / CTWH36 / IH4227
Vertical discharge with 8" (203) round duct for wall and island hoods. Transition is not required for internal blowers; in-line and remote blowers require TRANS-8-10. Backdraft damper included with wall and island hoods.
Blower configurations are for reference only. Refer to minimum CFM recommendations for your specific cooking product. Always consult a qualified HVAC Engineer for specific applications.
Loading...