from system supplier WOLF oers the ideal solution for commercial and
industrial buildings, new build and modernisation projects alike.
The range of WOLF control units can meet any requirement for heating convenience.
All equipment is easy to operate, highly energy ecient and reliable.
Solar thermal systems can be swiftly integrated into existing systems.
WOLF equipment is easy and quick to install and maintain.
Page 3
COMFORTLINE GAS CONDENSING BOILERSCGB0405
CGB-35-50
CGB-K-40-35
CGB-75-100
SPECIFICATION
06
06
06
0708
STANDARD CONTROL UNIT09
CONTROL ACCESSORIES
AIR/FLUE GAS ROUTING
ACCESSORIES
03
COMFORTLINE GAS CONDENSING BOILERS
1011
1213
1415
Page 4
Wall mounted gas condensing boilers
with sealed combustion chamber,
for room sealed or open flue operation
Smart home capable
via smartphone, laptop or PC
via WLAN-Modul WOLF Link pro / ISM7e
High standard seasonal efficiency [to DIN]
up to 110% (net cv)/ 99% (gross cv) for
the best possible energy eciency
Meets the requirements for the "Blue Angel" eco-label
to RAL-UZ 61 when operated with natural gas
Premix burner for natural gas
E, LL and LPG, variable modulating
heating output from 8kW
Optimum utilisation of condensing technology
modulating pump control
no return temperature raising required
heating water heat exchanger can , at CGB35 / 50
For maintenance:
be pivoted out under system pressure
without draining the heating water
04
Easy flue gas emissions testing
from outside without opening the
appliance
Page 5
WRS control system
can be set and controlled via smartphone or PC
BENEFITS OF WOLF
GAS CONDENSING BOILERS
FROM 35 TO 100 KW
CGB3550 / CGBK4035 / CGB75100
Convenient access to all components
for quick installation and straightforward
operation and maintenance
Cascadable up to 400 KW
Up to 4 gas condensing boilers can be combined using
a KM cascade controller.
05
COMFORTLINE GAS CONDENSING BOILERS
Page 6
CGB-35, CGB-50
440
393
855
WALL MOUNTED GAS CONDENSING BOILER FOR HEATING
with option to connect a DHW cylinder
e.g. SE-2
- With modulating high eciency pump (EE <0.21) as standard; no
mechanical switches in the heating water
- Coated heating water heat exchanger WOLF "ALUPro”
MODULATION RANGE
for flow / return 50 / 30°C
CGB-35from 9.0 to 35.0kW
CGB-50from 12.2 to 50.0kW
CGB-K-40-35
WALL MOUNTED GAS CONDENSING BOILER FOR HEATING AND DHW
- With integral stainless steel DHW heat exchanger
- For demand-dependent, hygienic DHW heating
- Precise flow control ensures consistent draw-o temperature
- With modulating high eciency pump (EE <0.21) as standard;
no mechanical switches in the heating water
MODULATION RANGE
for flow / return 50 / 30°C
CGB-K-40-35from 9.0 to 35.0kW
BOOSTER OUTPUT
for DHW heating
CGB-K-40-3540.0kW
CGB-75, CGB-100
WALL MOUNTED GAS CONDENSING BOILER FOR HEATING
with option to connect a DHW cylinder
e.g. SE-2
- High performance heat exchanger made from a robust aluminium/silicon
alloy, with smooth, vertically arranged fins; easy cleaning, high self-cleaning
eect, long service life
- Flue gas non-return device as standard; lowest cool-down losses; cascade
operation with positive pressure possible for up to four wall mounted gas
condensing boilers and an output range up to 400kW
MODULATION RANGE
for flow / return 50 / 30°C
CGB-75from 19.6 to 75.8kW
CGB-100from 19.6 to 98.8kW
06
Page 7
SPECIFICATIONCGB355075100
CGB-K----
Energy eciency class, central heating
Energy eciency class, DHW heating
Rated heating output at 80/60°CkW324670.191.932/39
4)
AAAA
-
40-35
A
1)
Rated heating output at 50/30 °CkW34.949.975.898.834.9
Rated heat inputkW334771.59433/40
Lowest heating output (modulating) at 80/60°CkW8/8.5
Lowest heating output (modulating) at 50/30°CkW9/9.5
Lowest heat input (modulating)kW8.5/9
3)
3)
3)
11/11.7
12.2/12.9
11.7/12.4
3)
3)
3)
18.218.28/8.5
19.619.69/9.5
18.518.58.5/9
1)
3)
3)
3)
Heating flow outside diameterG1¼"1¼"1½"1½"1¼"
Heating return outside diameterG1¼"1¼"1½"1½"1¼"
DHW connection/DHW circulationG----¾"
Cold water connectionG----¾"
Gas connectionR¾"¾"¾"¾"¾"
Air/flue pipe connectionmm80/12580/125110/160110/160 80/125
Standard seasonal eciency [to DIN] at 40/30°C (net cv/gross cv)
Standard seasonal eciency [to DIN] at 75/60°C (net cv/gross cv)
Eciency at rated load at 80/60°C (net cv/gross cv)
Eciency at 30% partial load and TR=30°C (net cv/gross cv)
%109/98109/98107/96107/96107/97
Flow temperature, factory setting°C7575808075
Flow temperature up to approx.°C
90
Max. total pressurebar3.03.06.06.03.0
Residual head for heating circuit:
1834 l/h flow rate (32kW at ∆t=20K)mbar250250--250
1977 l/h flow rate (46kW at ∆t=20K)mbar-235-3000l/h flow rate (70kW at ∆t=20K)mbar--3004000l/h flow rate (92kW at ∆t=20K)mbar---80
Water capacity of heating water heat exchangerl2.52.510102.5
DHW flow ratel/min----2.0-12.0
Spec. water throughput "D" to EN 625l/min----18
Min. flow pressure/min. flow pressure to EN 625bar----0.2/1.0
Max. permiss. total pressurebar----10
DHW temperature range (adjustable)
4)
°C----15-65
Corrosion protection, DHW heat exchanger----Stainless steel
Permiss. sensor temperatures°C
Flue gas mass flow rate at Qmaxg/s1521.533.743.515/18
95
1)
Flue gas mass flow rate at Qming/s3.95.38.98.93.9
Flue gas temperature 80/60-50/30 at Qmax°C65-4580-5072-4878-5365-45
Flue gas temperature 80/60-50/30 at Qmin°C66-4760-3860-3660-3666-47
Available gas fan draught at QmaxPa115145110200115/125
1)
Available gas fan draught at QminPa1010121210
Flue gas category to DVGW G 635
G52
NOx class6
Amount of condensate at 50/30°Cl/happrox. 3.9approx. 5.5approx. 7.1approx. 9.8
Condensate pH value
approx. 4.0
3.9/4.4
1)
Electrical connectionV~/Hz230/50
Integral fuse (medium time lag)A3.15
Power consumption with heating circuit pump class A
Power consumption with 3-stage heating circuit pump
IP rating
W110150--115
W13017575130135
IP X4D
Total weight (empty)kg4545929248
CE designationCE-0085BP5571CE-0085BR0164CE-0085BP5571
1)
Heating operation/DHW operation 2) Does not apply to Austria/Switzerland 3) LPG
4)
Energy class according to Ecodesign Directive for central heating with thermal output ≤70kW
07
COMFORTLINE GAS CONDENSING BOILERS
Page 8
DIMENSIONS AND CONNECTION DIMENSIONS
1
32
4
1
3672
4
CGB-35, 50
200
Condensate drain
CGB-75, 100
Gas connection R¾"
Heating return G1¼"
Gas connection R¾"
Heating flow G1¼"
Condensate drain
Heating return G1¼"
Heating flow G1¼"
CGB-K-40-35
Heating flow G1¼"
DHW connection G¾"
70
200
Condensate drain
Heating return G1¼"
Cold water connection G¾"
Gas connection R¾"
08
Page 9
STANDARD CONTROL UNIT CGB (35/50), (75/100) / CGB-K (40/35)
8
3
7
4
6
5
9
1
8
3
7
4
6
5
°C
0120
bar
04
2
13
Heating water
ON/OFF
Reset button
temperature selector
Thermometer
Illuminated ring for status display
Setting
Illuminated
ring
DHW temperature
selector
Pressure gauge
DisplayMeaning
Flashing greenStandby (mains power supply ON; no heat demand)
Constant green lightHeat demand: Pump running, burner OFF
Flashing yellowEmissions test mode
Constant yellow light Burner ON; flame steady
Flashing redFault
DHW temperature selector
The settings 1-9 correspond to a cylinder temperature of 15-65°C. In combination with
an external temperature controller the adjustment at the DHW temperature selector is
without eect, the setting is then made at the external temperature controller.
Heating water temperature selector
The setting range 2-8 corresponds to a heating water temperature of 20-75°C. In
combination with an external temperature controller the adjustment at the heating
water temperature selector is without eect, the setting is then made at the external
temperature controller.
Winter mode (positions 2 to 8)
The circulation pump operates in heating mode.
Summer mode
Switch is set to
circulation pump OFF (central heating OFF); only DHW heating, frost
protection and pump anti-seizing function are enabled, i.e. the circulation pump runs for
approx. 30s every 24hours.
Emissions test mode
If the switch is turned to the
position, the boiler operates with the maximum heating
output. The illuminated ring flashes yellow for 15 minutes or until the maximum flow
temperature has been exceeded.
Thermometer/pressure gauge
The heating water temperature and the heating system water pressure are displayed.
09
COMFORTLINE GAS CONDENSING BOILERS
Page 10
CONTROL ACCESSORIES CGB (35/50), (75/100) / CGB-K 40(/35)
Standard controller; part of the standard delivery of the gas condensing boiler
2-wire eBUS connection
BM programming unit (incl. outside
temp. sensor) as weather-compensated
temperature controller
• Room temperature-dependent/weather-compensated temperature control
• Time programs for central heating and DHW heating
• LCD with background illumination
• Plain text display with easy user prompts
• Operation via rotary selector with pushbutton function
• Four function keys for frequently used functions (central heating, DHW, setback, info)
• Installation either inside the boiler control unit, or as a remote control in a wall mounting base
• Option for MM mixer module
• Only one programming unit required for multi boiler systems
• Can be extended with MM mixer module (up to 7 heating circuits with mixer)
• Fault diagnosis
MM mixer module
• Extension module to control one circuit
with mixer
• Weather-compensated flow temperature
control
• Easy controller configuration by selecting
one of the preset system versions
• BM programming unit can be clipped into
the boiler or extended as a remote control
with wall mounting base
• Rast 5 connection technology
• Incl. flow temperature sensor
SM1-2 solar module
• Extension module to control one solar circuit incl. collector
temperature sensor, cylinder temperature sensor and sensor wells
• In conjunction with WOLF heat generators, greater energy savings
through intelligent cylinder reheating, i.e. blocking cylinder
reheating when there is sucient solar energy
• Heat metering with external heat meter
• Function check for flow rate and gravity brake
• Temperature dierential control for one heat consumer
• Maximum cylinder temperature limit
• Display of the set and actual values on the BM programming unit
• Integral hours run meter
• eBus interface with automatic energy management
• Rast 5 connection technology
BM programming unit
with wall mounting base (accessory)
as remote control
1 ... 7
SM2-2 solar module
• Extension module to control one solar thermal system
with up to 2 cylinders and 2collector arrays, incl. 1collector
sensor and 1 cylinder sensor, each with sensor well
• Easy controller configuration by selecting one of the
preset system versions
• In conjunction with WOLF heat generators, greater energy
savings through intelligent cylinder reheating, i.e. blocking
cylinder reheating when there is sucient solar energy
• Heat metering with external heat meter for all configurations
• Selection of cylinder operating mode
• Display of the set and actual values on the BM programming unit
• eBus interface with automatic energy management
• Rast 5 connection technology
10
Page 11
CONTROL ACCESSORIES CGB (35/50), (75/100) / CGB-K 40(/35)
KM cascade module
• Extension module to control systems
with a low loss header or cascade operation
• Can be used for gas condensing boiler
control units (4 appliances)
• Easy controller configuration by selecting
one of the preset system versions
• Control of one circuit with mixer
• BM programming unit can be clipped into
the boiler or extended as a remote control
with wall mounting base
• 0-10 V input for BMS systems; fault message output 230V
• eBus interface with automatic energy management
• Rast 5 connection technology
External wireless sensor
(only in conjunction with receiver
for external wireless sensor and
remote control, part no. 27 44 209)
2-wire eBUS connection
WOLF
portal server
Wireless receiver for external wireless sensor and wireless remote control
incl. radio clock (DCF77 signal)
Wireless remote control
(only in conjunction with receiver for
external wireless sensor and remote control)
Max. one wireless remote control per circuit with mixer.
ISM7e / WOLF Link pro
Local (home) network
The ISM7e / WOLFLinkpro interface
module allows remote access to WOLF
heating systems, both via the internet
and in local networks using a PC or
smartphone.
DSL router
(LAN / WLAN)
WLAN
LAN / WLAN
LAN / WLAN
LAN
11
COMFORTLINE GAS CONDENSING BOILERS
ISM7e / WOLF Link pro
interface module
eBus
Page 12
AIR/FLUE GAS ROUTING FOR WALL MOUNTED GAS CONDENSING BOILERS
B23
B33
C53C93xC43xC83x
C53x
C33x
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
IIIIIIIIIIIIIIIIIII
I
I
I
I
I
I
I
I
I
II
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
C33xC43x
C53xC93xC33xB33
C13x
FROM 35 KW TO 50KW
Design variantsMaximum length
TypeCGB-35
Flue inside a shaft and combustion air directly via the boiler
B23
(open flue)
Flue inside a shaft with horizontal concentric connection pipe
B33
(open flue)
Connection to a moisture-resistant flue gas chimney with
B33
a horizontal concentric connection pipe (open flue)
C13xHorizontal roof outlet through a pitched roof (room sealed)16168
Vertical concentric roof outlet through pitched or flat roof, vertical
C33x
concentric balanced flue system for installation in a shaft (room sealed)
Connection to a moisture-resistant balanced flue chimney, maximum
C43x
pipe length from centre of boiler bend to connection 2m (room sealed)
Connection to flue in a shaft and ventilation air supply through external wall
C53
(room sealed), incl. 3m supply air pipe
Connection to flue routed over an external wall; combustion air intake
C53x
via external wall panel (room sealed)
Connection to flue in a shaft and ventilation air through external wall
C53x
(room sealed)
Concentric connection to moisture-resistant flue gas chimney
C83x
and combustion air through external wall (room sealed)
Flue for installation in a shaft; rigid or flexible
C93x
1)
with horizontal concentric connection line
The maximum length refers to the total length from the appliance to the flue terminal
Note: System C33x is also suitable for installation in garages.
Where necessary, adapt the installation examples to the relevant building
regulations and requirements in your country/region. Any questions relating
to the installation of inspection sections and vents should be discussed with
the local flue gas inspector.
The specified lengths refer to concentric balanced flues and standard
flues, and apply to original WOLF components only.
Please observe the maximum length of the horizontal flue in accordance
with the boiler installation instructions.
The following balanced flues or standard flues with
CE-0036-CPD-9169003 certification may be used:
- Flue DN80
- Concentric balanced flue DN
- Flue DN110
- Concentric balanced flue (on an external wall) DN 80/125
- Flexible flue DN83
- Flexible flue DN110
WOLF accessories are supplied with the necessary identification
labels. Please also observe the installation information supplied
with the accessories.
12
DN80393923
DN110505050
DN80353516
DN110505050
(balanced flue manufacturer)
DN80/12516168
DN110/160424237
(balanced flue manufacturer)
DN80383819
DN110505050
DN80/125383819
DN110/160505050
DN80383819
DN110505050
(balanced flue manufacturer)
DN80252515
DN110434341
80/125
CGB-K-40-35
Calculation to EN 13384
Calculation to EN 13384
Calculation to EN 13384
1)
[m]
CGB-50
Page 13
AIR/FLUE GAS ROUTING FOR WALL MOUNTED GAS CONDENSING BOILERS
B23
B33
C53C93xC43xC83x
C53x
C33x
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
IIIIIIIIIIIIIIIIIII
I
I
I
I
I
I
I
I
I
II
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
C33xC43x
C53xC93xB33
C13x
FROM 75KW TO 100KW
Design variantsMaximum length
1)
TypeCGB-75CGB-100
Flue inside a shaft and combustion air directly via the boiler
B23
(open flue)
Flue inside a shaft with horizontal concentric connection pipe
B33
(open flue)
Connection to a moisture-resistant flue gas chimney with
B33
a horizontal concentric connection pipe (open flue)
Horizontal roof outlet through pitched roof
C13x
(room sealed
Vertical concentric roof outlet through a pitched
C33x
or flat roof (room sealed)
Connection to a moisture-resistant balanced flue chimney, maximum
C43x
pipe length from centre of boiler bend to connection 2m (room sealed)
Connection to flue in a shaft and ventilation air supply through external wall
C53
(room sealed), incl. 3m supply air pipe
Connection to flue routed over an external wall; combustion
C53x
air intake via external wall panel (room sealed)
Connection to flue in a shaft and ventilation
C53x
air through external wall (room sealed)
Concentric connection to moisture-resistant flue gas chimney and
C83x
combustion air through external wall (room sealed)
Vertical flue for installation in a shaft, rigid or flexible,
C93x
1)
2)
with horizontal concentric connection line
The maximum length refers to the total length from the appliance to the flue terminal
Enlargement in a shaft from DN110 to DN160
– on-site dormer
)
Note: Systems C33x and C83x are also suitable for installation in garages.
Where necessary, adapt the installation examples to the relevant building
regulations and requirements in your country/region. Any questions
relating to installation, particularly regarding inspection sections and vents
(ventilation generally required above 50kW output) should be discussed in
advance with the local flue gas inspector.
The specified lengths refer to concentric balanced flues and standard
flues, and apply to original WOLF components only.
Please observe the maximum length of the horizontal flue in accordance
with the boiler installation instructions.
13
DN110 to DN160
DN110 to DN 160
DN110 to DN
The following balanced flues or standard flues with
CE-0036-CPD-9169003 certification may be used:
- Flue DN110, 160 and 200
-
Concentric balanced flue DN110/160, DN160/225 and DN200/300
- Concentric balanced flue (on an external wall) DN110/160
- Flexible flue DN110
WOLF accessories are supplied with the necessary identification labels.
Please also observe the installation information supplied with the
accessories.
COMFORTLINE GAS CONDENSING BOILERS
DN1104446
DN100
3537
5050
Calculation to EN 13384
(balanced flue manufacturer)
DN110/1601010
DN110/1601214
Calculation to EN 13384
(balanced flue manufacturer)
DN1104144
2)
5050
DN1103940
DN1103638
2)
160
5050
Calculation to EN 13384
(balanced flue manufacturer)
DN1101921
DN110 to 160
2)
3131
[m]
Page 14
COMFORTLINE WALL MOUNTED GAS CONDENSING BOILERS
ACCESSORIES
CGB Wall mounted gas condensing boiler for central heating with option to connect a DHW cylinder
CGB-K Wall mounted gas condensing boiler for DHW and central heating
Tested in accordance with EC Directives and EN483 for heating systems to EN12828 with flow temperatures up to 90°C and 3bar
permissible operating pressure. Suitable for modulating operation down to room temperature; modulating output control; automatic
matching of the air ratio to the room sealed flue system; premix burner; equipped and adjusted in the factory for natural gas E, LL or
LPG; sealed combustion chamber for open flue and room sealed operation.
Control unit with gas burner control unit, electronic ignition and ionisation flame monitor; variable speed fan.
White RAL 9016 powder-coated casing.
Accessories
Control accessories
BM programming unit
Wall mounting base
AFB analogue remote control
MM mixer module
SM1-2 solar module
SM2-2 solar module
KM cascade module
Heat meter set for capturing solar yield
Wireless outside temperature sensor
(wireless receiver required)
Wireless remote control (wireless receiver required)
CGB-
35/50/75/100
CGB-K-
40-35
Wireless receiver incl. radio clock (also required for wireless
outside temperature sensor and wireless remote control)
ISM7e / WOLF Link Pro interface module
Hydraulic accessories and gas supply accessories
Gas ball valve (angle or straight-through version),
chrome plated, with thermally activated shut-o valve
Safety valve Rp ½" up to 3bar, chrome plated
Drain outlet kit R1" with trap and bezel, grey plastic
Accessories for surface mounting
● Included in standard delivery
○ Available accessory
14
Page 15
COMFORTLINE WALL MOUNTED GAS CONDENSING BOILERS
ACCESSORIES
Accessories
Heating circuit connection set
Low loss header set with complete pipework and
thermal insulation for 1 or 2 appliances
DHW circulation accessories
DHW circulation set to EnEV incl. DHW circulation pump with
analogue time switch
DHW circulation set to EnEV incl. DHW circulation pump with
digital time switch
Other accessories
Pipe cladding
Balanced flue accessories
Concentric balanced flue
External wall system
CGB-
35/50/75/100
only for CGB-75/100
CGB-K-
40-35
Flue system connection set for flues in a shaft
● Included in standard delivery
○ Available accessory