Wolf CGB-35/50 / CGB-75/100 DATA SHEET (Doc. no. 4800437 2018/07)

Page 1
30m3/h
WOLF GAS CONDENSING BOILERS
COMFORTLINE
CGB35/50 / CGB75/100
Page 2
EQUIPMENT RANGE
from system supplier WOLF oers the ideal solution for commercial and industrial buildings, new build and modernisation projects alike. The range of WOLF control units can meet any requirement for heating convenience. All equipment is easy to operate, highly energy ecient and reliable. Solar thermal systems can be swiftly integrated into existing systems.
WOLF equipment is easy and quick to install and maintain.
Page 3
COMFORTLINE GAS CONDENSING BOILERS CGB 0405
CGB-35-50
CGB-K-40-35
CGB-75-100
SPECIFICATION
06
06
06
0708
STANDARD CONTROL UNIT 09
CONTROL ACCESSORIES
AIR/FLUE GAS ROUTING
ACCESSORIES
03
COMFORTLINE GAS CONDENSING BOILERS
1011
1213
1415
Page 4
Wall mounted gas condensing boilers
with sealed combustion chamber,
for room sealed or open flue operation
Smart home capable
via smartphone, laptop or PC
via WLAN-Modul WOLF Link pro / ISM7e
High standard seasonal efficiency [to DIN]
up to 110% (net cv)/ 99% (gross cv) for
the best possible energy eciency
Meets the requirements for the "Blue Angel" eco-label
to RAL-UZ 61 when operated with natural gas
Premix burner for natural gas
E, LL and LPG, variable modulating
heating output from 8kW
Optimum utilisation of condensing technology
modulating pump control
no return temperature raising required
heating water heat exchanger can , at CGB35 / 50
For maintenance:
be pivoted out under system pressure
without draining the heating water
04
Easy flue gas emissions testing
from outside without opening the
appliance
Page 5
WRS control system
can be set and controlled via smartphone or PC
BENEFITS OF WOLF
GAS CONDENSING BOILERS FROM 35 TO 100 KW
CGB3550 / CGBK4035 / CGB75100
Convenient access to all components
for quick installation and straightforward operation and maintenance
Cascadable up to 400 KW
Up to 4 gas condensing boilers can be combined using
a KM cascade controller.
05
COMFORTLINE GAS CONDENSING BOILERS
Page 6
CGB-35, CGB-50
440
393
855
WALL MOUNTED GAS CONDENSING BOILER FOR HEATING
with option to connect a DHW cylinder e.g. SE-2
- With modulating high eciency pump (EE <0.21) as standard; no mechanical switches in the heating water
- Coated heating water heat exchanger WOLF "ALUPro”
MODULATION RANGE
for flow / return 50 / 30°C
CGB-35 from 9.0 to 35.0kW
CGB-50 from 12.2 to 50.0kW
CGB-K-40-35
WALL MOUNTED GAS CONDENSING BOILER FOR HEATING AND DHW
- With integral stainless steel DHW heat exchanger
- For demand-dependent, hygienic DHW heating
- Precise flow control ensures consistent draw-o temperature
- With modulating high eciency pump (EE <0.21) as standard;
no mechanical switches in the heating water
MODULATION RANGE
for flow / return 50 / 30°C
CGB-K-40-35 from 9.0 to 35.0kW
BOOSTER OUTPUT
for DHW heating
CGB-K-40-35 40.0kW
CGB-75, CGB-100
WALL MOUNTED GAS CONDENSING BOILER FOR HEATING
with option to connect a DHW cylinder e.g. SE-2
- High performance heat exchanger made from a robust aluminium/silicon alloy, with smooth, vertically arranged fins; easy cleaning, high self-cleaning eect, long service life
- Flue gas non-return device as standard; lowest cool-down losses; cascade operation with positive pressure possible for up to four wall mounted gas condensing boilers and an output range up to 400kW
MODULATION RANGE
for flow / return 50 / 30°C
CGB-75 from 19.6 to 75.8kW
CGB-100 from 19.6 to 98.8kW
06
Page 7
SPECIFICATION CGB 35 50 75 100
CGB-K - - - -
Energy eciency class, central heating
Energy eciency class, DHW heating
Rated heating output at 80/60°C kW 32 46 70.1 91.9 32/39
4)
A A A A
-
40-35
A
1)
Rated heating output at 50/30 °C kW 34.9 49.9 75.8 98.8 34.9 Rated heat input kW 33 47 71.5 94 33/40 Lowest heating output (modulating) at 80/60°C kW 8/8.5 Lowest heating output (modulating) at 50/30°C kW 9/9.5 Lowest heat input (modulating) kW 8.5/9
3)
3)
3)
11/11.7
12.2/12.9
11.7/12.4
3)
3)
3)
18.2 18.2 8/8.5
19.6 19.6 9/9.5
18.5 18.5 8.5/9
1)
3)
3)
3)
Heating flow outside diameter G 1¼" 1¼" 1½" 1½" 1¼" Heating return outside diameter G 1¼" 1¼" 1½" 1½" 1¼" DHW connection/DHW circulation G - - - - ¾" Cold water connection G - - - - ¾" Gas connection R ¾" ¾" ¾" ¾" ¾" Air/flue pipe connection mm 80/125 80/125 110/160 110/160 80/125
Gas category
II2ELL3P
Gas supply details:
Nat. gas E/H (net cv = 9.5 kWh/m = 34.2 MJ/m  Nat. gas LL (net cv = 8.6 kWh/m = 31.0 MJ/m)  LPG (net cvi = 12.8 kWh/kg = 46.1 MJ/kg)
Supply pressure, natural gas (permissible min./max.)
)
m/h 3.84 5.5 8.6 11.11
kg/h 2.57 3.66 5.76 7.44
m/h 3.47 4.94 7.77 10.03
3.47/4.34
3.84/5.10
2.57/3.40
mbar 20 (18-25)
1)
1)
1)
Supply pressure, LPG (permissible min./max.) mbar 50 (43-57)
Standard seasonal eciency [to DIN] at 40/30°C (net cv/gross cv) Standard seasonal eciency [to DIN] at 75/60°C (net cv/gross cv) Eciency at rated load at 80/60°C (net cv/gross cv) Eciency at 30% partial load and TR=30°C (net cv/gross cv)
% 109/98 110/99 109/98 % 108/97 107/96 106/96 % 98/88 97/88 98/88
% 109/98 109/98 107/96 107/96 107/97 Flow temperature, factory setting °C 75 75 80 80 75 Flow temperature up to approx. °C
90
Max. total pressure bar 3.0 3.0 6.0 6.0 3.0
Residual head for heating circuit:
1834 l/h flow rate (32kW at t=20K) mbar 250 250 - - 250 1977 l/h flow rate (46kW at t=20K) mbar - 235 - ­3000l/h flow rate (70kW at t=20K) mbar - - 300 ­4000l/h flow rate (92kW at t=20K) mbar - - - 80
Water capacity of heating water heat exchanger l 2.5 2.5 10 10 2.5 DHW flow rate l/min - - - - 2.0-12.0 Spec. water throughput "D" to EN 625 l/min - - - - 18 Min. flow pressure/min. flow pressure to EN 625 bar - - - - 0.2/1.0 Max. permiss. total pressure bar - - - - 10 DHW temperature range (adjustable)
4)
°C - - - - 15-65 Corrosion protection, DHW heat exchanger - - - - Stainless steel Permiss. sensor temperatures °C Flue gas mass flow rate at Qmax g/s 15 21.5 33.7 43.5 15/18
95
1)
Flue gas mass flow rate at Qmin g/s 3.9 5.3 8.9 8.9 3.9 Flue gas temperature 80/60-50/30 at Qmax °C 65-45 80-50 72-48 78-53 65-45 Flue gas temperature 80/60-50/30 at Qmin °C 66-47 60-38 60-36 60-36 66-47
Available gas fan draught at Qmax Pa 115 145 110 200 115/125
1)
Available gas fan draught at Qmin Pa 10 10 12 12 10 Flue gas category to DVGW G 635
G52 NOx class 6 Amount of condensate at 50/30°C l/h approx. 3.9 approx. 5.5 approx. 7.1 approx. 9.8 Condensate pH value
approx. 4.0
3.9/4.4
1)
Electrical connection V~/Hz 230/50 Integral fuse (medium time lag) A 3.15 Power consumption with heating circuit pump class A Power consumption with 3-stage heating circuit pump IP rating
W 110 150 - - 115 W 130 175 75 130 135
IP X4D Total weight (empty) kg 45 45 92 92 48 CE designation CE-0085BP5571 CE-0085BR0164 CE-0085BP5571
1)
Heating operation/DHW operation 2) Does not apply to Austria/Switzerland 3) LPG
4)
Energy class according to Ecodesign Directive for central heating with thermal output ≤70kW
07
COMFORTLINE GAS CONDENSING BOILERS
Page 8
DIMENSIONS AND CONNECTION DIMENSIONS
1
32
4
1
3672
4
CGB-35, 50
200
Condensate drain
CGB-75, 100
Gas connection R¾"
Heating return G1¼"
Gas connection R¾"
Heating flow G1¼"
Condensate drain
Heating return G1¼"
Heating flow G1¼"
CGB-K-40-35
Heating flow G1¼"
DHW connection G¾"
70
200
Condensate drain
Heating return G1¼"
Cold water connection G¾"
Gas connection R¾"
08
Page 9
STANDARD CONTROL UNIT CGB (35/50), (75/100) / CGB-K (40/35)
8
3
7
4
6
5
9
1
8
3
7
4
6
5
°C
0 120
bar
04
2
13
Heating water
ON/OFF
Reset button
temperature selector
Thermometer
Illuminated ring for status display
Setting
Illuminated ring
DHW temperature selector
Pressure gauge
Display Meaning
Flashing green Standby (mains power supply ON; no heat demand)
Constant green light Heat demand: Pump running, burner OFF
Flashing yellow Emissions test mode
Constant yellow light Burner ON; flame steady
Flashing red Fault
DHW temperature selector
The settings 1-9 correspond to a cylinder temperature of 15-65°C. In combination with an external temperature controller the adjustment at the DHW temperature selector is without eect, the setting is then made at the external temperature controller.
Heating water temperature selector
The setting range 2-8 corresponds to a heating water temperature of 20-75°C. In combination with an external temperature controller the adjustment at the heating water temperature selector is without eect, the setting is then made at the external temperature controller.
Winter mode (positions 2 to 8) The circulation pump operates in heating mode.
Summer mode
Switch is set to
circulation pump OFF (central heating OFF); only DHW heating, frost protection and pump anti-seizing function are enabled, i.e. the circulation pump runs for approx. 30s every 24hours.
Emissions test mode
If the switch is turned to the
position, the boiler operates with the maximum heating output. The illuminated ring flashes yellow for 15 minutes or until the maximum flow temperature has been exceeded.
Thermometer/pressure gauge
The heating water temperature and the heating system water pressure are displayed.
09
COMFORTLINE GAS CONDENSING BOILERS
Page 10
CONTROL ACCESSORIES CGB (35/50), (75/100) / CGB-K 40(/35)
Standard controller; part of the standard delivery of the gas condensing boiler
2-wire eBUS connection
BM programming unit (incl. outside
temp. sensor) as weather-compensated
temperature controller
• Room temperature-dependent/weather-compensated temperature control
• Time programs for central heating and DHW heating
• LCD with background illumination
• Plain text display with easy user prompts
• Operation via rotary selector with pushbutton function
• Four function keys for frequently used functions (central heating, DHW, setback, info)
• Installation either inside the boiler control unit, or as a remote control in a wall mounting base
• Option for MM mixer module
• Only one programming unit required for multi boiler systems
• Can be extended with MM mixer module (up to 7 heating circuits with mixer)
• Fault diagnosis
MM mixer module
• Extension module to control one circuit with mixer
• Weather-compensated flow temperature control
• Easy controller configuration by selecting one of the preset system versions
• BM programming unit can be clipped into the boiler or extended as a remote control with wall mounting base
• Rast 5 connection technology
• Incl. flow temperature sensor
SM1-2 solar module
• Extension module to control one solar circuit incl. collector temperature sensor, cylinder temperature sensor and sensor wells
• In conjunction with WOLF heat generators, greater energy savings through intelligent cylinder reheating, i.e. blocking cylinder reheating when there is sucient solar energy
• Heat metering with external heat meter
• Function check for flow rate and gravity brake
• Temperature dierential control for one heat consumer
• Maximum cylinder temperature limit
• Display of the set and actual values on the BM programming unit
• Integral hours run meter
• eBus interface with automatic energy management
• Rast 5 connection technology
BM programming unit
with wall mounting base (accessory)
as remote control
1 ... 7
SM2-2 solar module
• Extension module to control one solar thermal system
with up to 2 cylinders and 2collector arrays, incl. 1collector sensor and 1 cylinder sensor, each with sensor well
• Easy controller configuration by selecting one of the
preset system versions
• In conjunction with WOLF heat generators, greater energy
savings through intelligent cylinder reheating, i.e. blocking cylinder reheating when there is sucient solar energy
• Heat metering with external heat meter for all configurations
• Selection of cylinder operating mode
• Display of the set and actual values on the BM programming unit
• eBus interface with automatic energy management
• Rast 5 connection technology
10
Page 11
CONTROL ACCESSORIES CGB (35/50), (75/100) / CGB-K 40(/35)
KM cascade module
• Extension module to control systems with a low loss header or cascade operation
• Can be used for gas condensing boiler control units (4 appliances)
• Easy controller configuration by selecting one of the preset system versions
• Control of one circuit with mixer
• BM programming unit can be clipped into the boiler or extended as a remote control with wall mounting base
• 0-10 V input for BMS systems; fault message output 230V
• eBus interface with automatic energy management
• Rast 5 connection technology
External wireless sensor
(only in conjunction with receiver for external wireless sensor and remote control, part no. 27 44 209)
2-wire eBUS connection
WOLF
portal server
Wireless receiver for external wireless sensor and wireless remote control
incl. radio clock (DCF77 signal)
Wireless remote control
(only in conjunction with receiver for external wireless sensor and remote control) Max. one wireless remote control per circuit with mixer.
ISM7e / WOLF Link pro
Local (home) network
The ISM7e / WOLFLinkpro interface module allows remote access to WOLF heating systems, both via the internet and in local networks using a PC or smartphone.
DSL router
(LAN / WLAN)
WLAN
LAN / WLAN
LAN / WLAN
LAN
11
COMFORTLINE GAS CONDENSING BOILERS
ISM7e / WOLF Link pro
interface module
eBus
Page 12
AIR/FLUE GAS ROUTING FOR WALL MOUNTED GAS CONDENSING BOILERS
B23 B33
C53 C93x C43x C83x
C53x
C33x
I I
I I I I I
I I I I
I I I I I
I I I I I
I I I I
I I I I I
I I I I I
I I I I
I I I I I
I I I I
I I I I I
I I I I I
I I I I
I I I I I
I I I I I
I I I I
I I I I I
I I I I
I I I I I
I I I I I
I I I I
I I I I
I I I I
IIIIIIIIIIIIIIIIIII
I
I
I
I
I
I
I
I
I
II
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
C33x C43x
C53x C93x C33x B33
C13x
FROM 35 KW TO 50KW
Design variants Maximum length
Type CGB-35
Flue inside a shaft and combustion air directly via the boiler
B23
(open flue)
Flue inside a shaft with horizontal concentric connection pipe
B33
(open flue)
Connection to a moisture-resistant flue gas chimney with
B33
a horizontal concentric connection pipe (open flue)
C13x Horizontal roof outlet through a pitched roof (room sealed) 16 16 8
Vertical concentric roof outlet through pitched or flat roof, vertical
C33x
concentric balanced flue system for installation in a shaft (room sealed)
Connection to a moisture-resistant balanced flue chimney, maximum
C43x
pipe length from centre of boiler bend to connection 2m (room sealed)
Connection to flue in a shaft and ventilation air supply through external wall
C53
(room sealed), incl. 3m supply air pipe
Connection to flue routed over an external wall; combustion air intake
C53x
via external wall panel (room sealed)
Connection to flue in a shaft and ventilation air through external wall
C53x
(room sealed)
Concentric connection to moisture-resistant flue gas chimney
C83x
and combustion air through external wall (room sealed)
Flue for installation in a shaft; rigid or flexible
C93x
1)
with horizontal concentric connection line
The maximum length refers to the total length from the appliance to the flue terminal
Note: System C33x is also suitable for installation in garages.
Where necessary, adapt the installation examples to the relevant building regulations and requirements in your country/region. Any questions relating to the installation of inspection sections and vents should be discussed with the local flue gas inspector.
The specified lengths refer to concentric balanced flues and standard flues, and apply to original WOLF components only.
Please observe the maximum length of the horizontal flue in accordance with the boiler installation instructions.
The following balanced flues or standard flues with CE-0036-CPD-9169003 certification may be used:
- Flue DN80
- Concentric balanced flue DN
- Flue DN110
- Concentric balanced flue (on an external wall) DN 80/125
- Flexible flue DN83
- Flexible flue DN110 WOLF accessories are supplied with the necessary identification
labels. Please also observe the installation information supplied with the accessories.
12
DN80 39 39 23
DN110 50 50 50
DN80 35 35 16
DN110 50 50 50
(balanced flue manufacturer)
DN80/125 16 16 8
DN110/160 42 42 37
(balanced flue manufacturer)
DN80 38 38 19
DN110 50 50 50
DN80/125 38 38 19
DN110/160 50 50 50
DN80 38 38 19
DN110 50 50 50
(balanced flue manufacturer)
DN80 25 25 15
DN110 43 43 41
80/125
CGB-K-40-35
Calculation to EN 13384
Calculation to EN 13384
Calculation to EN 13384
1)
[m]
CGB-50
Page 13
AIR/FLUE GAS ROUTING FOR WALL MOUNTED GAS CONDENSING BOILERS
B23 B33
C53 C93x C43x C83x
C53x
C33x
I I
I I I I I
I I I I
I I I I I
I I I I I
I I I I
I I I I I
I I I I I
I I I I
I I I I I
I I I I
I I I I I
I I I I I
I I I I
I I I I I
I I I I I
I I I I
I I I I I
I I I I
I I I I I
I I I I I
I I I I
I I I I
I I I I
IIIIIIIIIIIIIIIIIII
I
I
I
I
I I
I
I
I
II
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
C33x C43x
C53x C93x B33
C13x
FROM 75KW TO 100KW
Design variants Maximum length
1)
Type CGB-75 CGB-100
Flue inside a shaft and combustion air directly via the boiler
B23
(open flue) Flue inside a shaft with horizontal concentric connection pipe
B33
(open flue)
Connection to a moisture-resistant flue gas chimney with
B33
a horizontal concentric connection pipe (open flue) Horizontal roof outlet through pitched roof
C13x
(room sealed Vertical concentric roof outlet through a pitched
C33x
or flat roof (room sealed) Connection to a moisture-resistant balanced flue chimney, maximum
C43x
pipe length from centre of boiler bend to connection 2m (room sealed)
Connection to flue in a shaft and ventilation air supply through external wall
C53
(room sealed), incl. 3m supply air pipe
Connection to flue routed over an external wall; combustion
C53x
air intake via external wall panel (room sealed)
Connection to flue in a shaft and ventilation
C53x
air through external wall (room sealed)
Concentric connection to moisture-resistant flue gas chimney and
C83x
combustion air through external wall (room sealed)
Vertical flue for installation in a shaft, rigid or flexible,
C93x
1)
2)
with horizontal concentric connection line
The maximum length refers to the total length from the appliance to the flue terminal
Enlargement in a shaft from DN110 to DN160
– on-site dormer
)
Note: Systems C33x and C83x are also suitable for installation in garages.
Where necessary, adapt the installation examples to the relevant building regulations and requirements in your country/region. Any questions relating to installation, particularly regarding inspection sections and vents (ventilation generally required above 50kW output) should be discussed in advance with the local flue gas inspector.
The specified lengths refer to concentric balanced flues and standard flues, and apply to original WOLF components only.
Please observe the maximum length of the horizontal flue in accordance with the boiler installation instructions.
13
DN110 to DN160
DN110 to DN 160
DN110 to DN
The following balanced flues or standard flues with CE-0036-CPD-9169003 certification may be used:
- Flue DN110, 160 and 200
-
Concentric balanced flue DN110/160, DN160/225 and DN200/300
- Concentric balanced flue (on an external wall) DN110/160
- Flexible flue DN110 WOLF accessories are supplied with the necessary identification labels.
Please also observe the installation information supplied with the accessories.
COMFORTLINE GAS CONDENSING BOILERS
DN110 44 46
DN100
35 37 50 50
Calculation to EN 13384
(balanced flue manufacturer)
DN110/160 10 10
DN110/160 12 14
Calculation to EN 13384
(balanced flue manufacturer)
DN110 41 44
2)
50 50
DN110 39 40
DN110 36 38
2)
160
50 50
Calculation to EN 13384
(balanced flue manufacturer)
DN110 19 21
DN110 to 160
2)
31 31
[m]
Page 14
COMFORTLINE WALL MOUNTED GAS CONDENSING BOILERS ACCESSORIES
CGB Wall mounted gas condensing boiler for central heating with option to connect a DHW cylinder
CGB-K Wall mounted gas condensing boiler for DHW and central heating
Tested in accordance with EC Directives and EN483 for heating systems to EN12828 with flow temperatures up to 90°C and 3bar permissible operating pressure. Suitable for modulating operation down to room temperature; modulating output control; automatic matching of the air ratio to the room sealed flue system; premix burner; equipped and adjusted in the factory for natural gas E, LL or LPG; sealed combustion chamber for open flue and room sealed operation.
Control unit with gas burner control unit, electronic ignition and ionisation flame monitor; variable speed fan.
White RAL 9016 powder-coated casing.
Accessories
Control accessories
BM programming unit
Wall mounting base
AFB analogue remote control
MM mixer module
SM1-2 solar module
SM2-2 solar module
KM cascade module
Heat meter set for capturing solar yield
Wireless outside temperature sensor (wireless receiver required)
Wireless remote control (wireless receiver required)
CGB-
35/50/75/100
CGB-K-
40-35
Wireless receiver incl. radio clock (also required for wireless outside temperature sensor and wireless remote control)
ISM7e / WOLF Link Pro interface module
Hydraulic accessories and gas supply accessories
Gas ball valve (angle or straight-through version), chrome plated, with thermally activated shut-o valve
Safety valve Rp ½" up to 3bar, chrome plated
Drain outlet kit R1" with trap and bezel, grey plastic
Accessories for surface mounting
Included in standard delivery Available accessory
14
Page 15
COMFORTLINE WALL MOUNTED GAS CONDENSING BOILERS
ACCESSORIES
Accessories
Heating circuit connection set
Low loss header set with complete pipework and thermal insulation for 1 or 2 appliances
DHW circulation accessories
DHW circulation set to EnEV incl. DHW circulation pump with analogue time switch
DHW circulation set to EnEV incl. DHW circulation pump with digital time switch
Other accessories
Pipe cladding
Balanced flue accessories
Concentric balanced flue
External wall system
CGB-
35/50/75/100
only for CGB-75/100
CGB-K-
40-35
Flue system connection set for flues in a shaft
Included in standard delivery Available accessory
15
15
COMFORTLINE GAS CONDENSING BOILERS
Page 16
Dealer address
WOLF GMBH / P.O. BOX 1380 / D84048 MAINBURG / TEL. +49.0.8751740 / FAX +49.0.8751741600 / www.WOLF.eu
Doc. no. 4800437 2018/07