Operating instructions
Gas red condensing boiler
CGB-11 Boiler
CGB-20 Boiler
CGB-24 Boiler
CGB-35 Boiler
CGB-50 Boiler
CGB-75 Boiler
CGB-100 Boiler
CGB-K-20 Combi boiler
CGB-K-24 Combi boiler
Wolf GmbH · Postfach 1380 · 84048 Mainburg · Tel. 08751/74-0 · Fax 08751/741600 · Internet: www.wolf-heiztechnik.de
Art.-Nr. 30 61 345 Salvo modiche 06/09 GB

Index ........................................................................................................page
General information ................................................................................................... 2
Safety instructions ...................................................................................................... 3
Installation and maintenance information ................................................................. 4
Water connections and gas supply connection ........................................................ 5
Control unit operation ................................................................................................. 6
Information for energy-efcient operation ............................................................... 7-8
Index
General information
Gas is an environmentally friendly fuel which does not represent any danger,unless
handled with gross negligence. Your gas red condensing boiler is a highquality product
which incorporates the latest safety technology.
These safety instructions should protect you from potential risks.

SAFETY INSTRUCTIONS
SAFETY INSTRUCTIONS
Balanced ue system
With low outside temperatures, the water vapour contained in the ue gas may condense and freeze on the balanced ue pipe. This ice may fall from the roof causing
injury or material losses. Prevent through on-site measures, e.g. the installation of
a snow catcher grille.
APlease note - risk of injury
Frost protection
The gas red condensing boiler will be protected automatically against frost as long as
it is switched ON. Never use any anti-freeze.
Completely drain the boiler if necessary.
Please note - risk of water damage and faulty function through freezing.
When changing a fuse
- Isolate the boiler from the power supply before changing a fuse. The power supply
terminals of the boiler are ‚live‘ even when the ON/OFF switch has been switched
OFF.
Please note - risk of electrocution.
If you smell ue gas
- shut down the system
- open windows and doors
- notify your local contractorn
Please note - risk of poisoning.
- never switch ON any lights
- never operate electrical switches
- keep naked ames away
- close the gas shut-off valve
- open windows and doors
- inform your gas supply company; use a telephone outside the danger area
Please note - risk of poisoning, suffocation and explosion.
If you smell gas