
www.carl-wittkopp.com
HotelStar 7214
Changing users
1 General instructions
• Please read the operating instructions carefully, before activating the lock.
• The lock is supplied with the following master code: 1-2-3-4-5-6.
For your security, change the factory code immediately.
• Do not use any personal data like birthdays or telephone numbers as
new code.
• If the time window to enter the new code is exceeded, the system shuts
down. An active code stays valid.
• After 4 consecutive wrong code insertions a blocking time of 1 minute
sets in, which doubles after every following wrong insertion (up to 16
minutes max.).
• Each key press is conrmed acoustically.
• Do not use any force.
• Never open the lock case, otherwise the correct operation is at risk and
warranty will be void.
2 Status request
Press the “C“ button while the lock is in standby (not during a code insertion
or programming of the lock).
Red LED illuminated = Electronic lock is open
Green LED illuminated = Electronic lock is locked
Operating Instructions
© Carl Wittkopp GmbH - errors and omissions excepted

2 Operating Instructions No. 9999-096-0
Operating Instructions
14.03.2011
HotelStar 7214
3 Instructions for the hotel guest
3.1 Locking
At any time upon locking a 4-digit user code can be chosen.
1. Close the safe door.
2.
Enter a 4-digit user code and conrm with “*“
e.g.
4725*
3.
The successful insertion is conrmed by 2 signalling tones.
2 x
4. The lock´s bolt closes automatically.
5.
Always check after locking if the safe door is
really locked.
You can always interrupt a wrong code insertion with “C“ or by waiting 5 seconds
and then start re-entering.
3.2 Opening
By opening the safe lock the old user code is deleted.
1.
Enter a 4-digit user code and conrm with “*“
e.g.
4725*
2.
The successful insertion is conrmed by 1 signalling tone.
1 x
3. The lock´s bolt opens automatically.
4. Open the safe door.

Operating Instructions No. 9999-096-0 3
Operating Instructions
14.03.2011
HotelStar 7214
4 Instructions for the master
4.1 Locking
The electronic lock can only be closed by entering the user code. The master can
not close the lock with his code.
4.2 Opening
If the safe lock is opened by the master code the active user code is deleted.
1.
Enter a 6-digit master code and conrm with “*“
e.g.
123456*
2.
The successful insertion is conrmed by 1 signalling tone.
1 x
3. The lock´s bolt opens automatically.
4. Open the safe door.
4.3 Changing the master code
The programming of a new master code can be done at any time.
1. Start the programming.
*1*
2.
Enter the old master code and conrm with “*“
e.g.
123456*
3.
Enter the new master code and conrm with “*“
e.g.
872744*
4.
Re-enter the new master code and conrm with
“*“ e.g.
872744*

4 Operating Instructions No. 9999-096-0
Operating Instructions
14.03.2011
HotelStar 7214
5 Power supply and battery change
The lock is supplied by a 9 V alkaline block battery (no rechargeable battery!). When
battery charge is running low, signalling tones occur a couple of times after entering
the code and the red and the green LED ash alternately.
Change the battery as soon as possible. The programmed codes stay active during
the battery change. Always dispose of your batteries environment friendly.
6 Visual and acoustic signal types
Signal type Reason Note
2 x Correct code
12 x Wrong code
every 5
seconds
Blocking time
active
Blocking time can not be disrupted (see
ref. p.1).
10 x
10 x
Battery warning
Battery should be changed as soon as
possible.
G
R
GR
R
Open the input unit’s
case in the direction
of the arrow
Fig.: Input unit
red green