Wisy SIGMA Installation Instructions

Installation Instructions
● Operating instructions for the SIGMA rainwater unit
● Please read through these instructions carefully before you attempt to install and use the rainwater unit!
● 3- or 4-stage self-priming centrifugal pump
● Operates fully automatically to supply household appliances on demand
● Automatic mains water top-up with integral 9-litre top-up tank
● Energy efficient technology, standby usage less than 0.2 W
WISY Rainwater Harvesting
SIGMA Rainwater Unit
ΣΣ
Sigma
2
30 %
5 %
Harvesting rainwater reduces mains water
consumption by:
50 %!
WC:
30 %
Laundry:
13 %
Garden irrigation: 5 % Cleaning:
2 %
13 %
2 %
1
Vortex fine filter (WFF)
2
Inflow calming
3
Floating
suction filter
4
Multisiphon
5
Rainwater storage tank
6
Sigma rainwater unit
7
Filter collector (FS)
8
Rainwater barrel 500 l
Stage 2
WISY inflow calming prevents resuspension of sediment and distributes the fresh, oxygen-rich water in the storage tank
Stage 3
Water is extracted with the WISY floating suction filter suspended at the optimum height
Stage 4
Overflow with skim effect, odour seal, small animal guard and backflow pre­vention with WISY multi­siphon
The WISY 4-stage rainwater cleansing system
6
7
8
1
4
2
3
5
The WISY 4-stage rainwater cleansing principle in the single-family home
Stage 1
Filtering with WISY vortex fine filter with separation of dirt particles and oxygen enrichment
3
SIGMA Rainwater Unit
Please read through these instructions carefully before you attempt to install and use the rainwater unit! Original installation instructions and usage guide for the rainwater unit
These installation instructions include the following information relating to:
● General description, applications and proper use
● Safety information and warning notices
● Delivery, scope of supply and design
● Recommended accessories
● Design and operating principle
● Installation
● Commissioning
● Maintenance, servicing
● Troubleshooting guide
● Technical data
● Guarantee conditions
● Company name and address
● Overview diagram (annex)
● Declaration of conformity (annex)
● Konformitätserklärung (Anlage)
Applications
The SIGMA rainwater unit developed by WISY is a complete rainwater harvesting system with integral self-priming pump, control system and automatic mains wa­ter top-up. It combines numerous individual devices to form a single package for installation in a utility room or basement.
SIGMA pumps the rainwater out of the storage tank and feeds it under pres­sure into the rainwater supply circuit. At the same time, SIGMA controls the entire rainwater harvesting system, monitors the fill level of the storage tank and automatically tops up the system with mains water when required. SIGMA is available with an optional level indicator
SIGMA is designed to supply toilet cisterns, washing machines and garden irriga­tion systems in single-family homes with clear, filtered rainwater.
Important preconditions for correct operation of the system:
● The suction line must be installed with a continuous rise from the rainwater storage tank to the SIGMA unit. The wall unit must be installed above the maximum water level in the rainwater storage tank.
● With a height difference of 3 m between the wall unit and the rainwater storage tank base, a suction line of up to 15 metres in length may be required (see diagram).
● The suction line must have an inside diameter of at least 1“ (2.54 cm).
● A floating fine suction filter FFSF (item SZ 9924) with non-return valve
is required in the rainwater storage tank
If the rainwater storage tank must be installed with a larger height differential or at a greater distance from the rainwater unit due to the site topology, WISY‘s OPTIMA / OPTIMAPlus rainwater units can be installed. OPTIMA rainwater units operate without a suction line and are designed to pump water over longer line distances/ height differences.
SIGMA cannot be used to supply outlets at a rate of less than 1 litre per minute (e.g. drip irrigation systems; outlets must close completely, the rainwater circuit must be leak-tight).
SIGMA is not suitable for pumping dirty rainwater or well water (which contains dirt or sand particles). SIGMA cannot be used to pump water out of a dirty rain­water storage tank. Improper use of the equipment can result in destruction of the pump.
Contents
OPTIMA rainwater units for greater distances and height differences
Proper use
Improper use
With floating fine suction filter (accessory) and float switch
!
4
1 Mains water connection (top-up)
2 Suction line connection (from storage tank)
3 Pressurized outlet (distribution system)
4 Measuring lead for level indicator
5 SIGMA mains plug
6 Electrical connection for float switch
7 Emergency overflow drain connection (DN 70)
8 Adjusting screws for level indicator:
a) Left-hand screw: Fill level adjustment b) Right-hand screw: Zero-point calibration
9 Level indicator
10 Operating pressure indicator
(pressure gauge)
11 Self-priming centrifugal pump
12 Automatic switch (with display
and operator panel)
13 Base frame
14 Connecting hose to pressurized outlet
16 Float switch
17 Measuring lead in storage tank, with weight
18 Screw plug for venting/filling
Accessories not included in the scope of supply:
15 Floating fine suction filter (FFSF)
with non-return valve (accessory)
19 Isolating valves
20 Multisiphon (odour seal and
backflow prevention)
21 Water meter for mains water top-up
22 Water meter for pumped rising main
23 Flexible connecting hoses
1
8
9
10
12
2
16
3141811
13
Guide to components
5
Safety instructions
Read the operating instructions carefully before commencing assembly and in­stallation work and store them in a safe place for later reference.
Do not lift or pull the float switch by its electric cable.
Never climb inside the storage tank when the SIGMA rainwater unit is connec­ted to the power supply. Always unplug the SIGMA rainwater unit to disconnect it from the power supply before carrying out any inspection, maintenance or repair work to the SIGMA rainwater unit or inside the storage tank.
Never leave the rainwater storage tank unsupervised when it is open! No one ex­cept specially trained personnel is allowed to climb inside the rainwater storage tank. When working inside the tank, personnel must be supervised at all times and must take appropriate safety precautions (e.g. wear a recovery harness).
If the residual current device or the fuse trips, the trip cause must be identified and rectified by the manufacturer / by a contractor appointed by the manufac­turer.
If the power cable to the SIGMA unit or the float switch is found to be damaged, it must be replaced by the manufacturer / by a contractor appointed by the manufacturer.
Installation work which involves particular hazards (e.g. risk to mains water sup­ply or the electrical installation) must always be carried out by a properly trai­ned, approved plumber or electrician who is at least qualified in the following technical areas:
● Selection of appropriate tools and suitable electrical and installation materials
● IP degrees of protection
● Correct methods of installing electrical and other materials
● TN-C system, TN-S system and appropriate additional measures
where necessary.
● Drinking water protection in accordance with DIN EN 1717, DIN 1989 Failure to install the equipment properly can endanger your own life and the lives of people who use the equipment.
The system must be connected to a 230 V, single-phase AC (50 Hz) supply. The SIGMA unit must be operated with clean water (rainwater or mains water) which does not contain aggressive, abrasive or solid substances.
Failure to adhere to these instructions and/or unauthorized interference with the SIGMA shall exempt WISY AG from any liability for any personal injuries, property damage and/or damage to individual components of the SIGMA sys­tem.
The SIGMA product is generally shipped in a cardboard box. The cardboard box must not be dropped, crushed or handled with force, and must be inspected for damage as soon as it is received.
The cardboard box or its unpacked contents must be stored in a safe, dry, and frost-free location and protected against the ingress of dirt or contaminants.
Scope of supply and design
● Self-priming, multi-stage centrifugal pump with automatic switch SA 06, pressure indication: Operating pressure max. 3.3 / 4.4 bar; delivery rate max. 65 l/min.
● Mains water top-up function compliant with DIN EN 1717, automatically fills the mains top-up tank (9-litre volume) integrated in the wall unit when in­sufficient rainwater is available, float valve with dirt filter; mains top-up tank with safety emergency overflow DN 70.
● Cover to protect the rainwater unit.
● Wall mounting kit.
● Level indicator (optional) for indicating water level in the rainwater storage
tank, with measuring lead, length 13 m, and connection kit.
● Float switch (yellow) with stainless steel clamp for attachment to tube dia­meter 110 to 130 mm, with 15 m electric cable without plug, for connection to the wall unit.
Additional instructions
Delivery / shipment of the unit
Wall unit for indoor installation
Storage tank equipment
6
Manual switchover to mains water operation
Mains water operation when rainwater level is low
Dry run protection
Accessories
Components which are not supplied as standard
● Hoses for connecting the SIGMA rainwater unit to the rainwater circuit and the mains water top-up, two ¾“ pressure hoses with stainless steel sheath,
0.5 m in length, with 1“ union nut and ¾“ brass ball valve, with dirt trap for mains water top-up (Item No. RW 78 00).
● 1“ full-bore brass ball valve for suction end of wall unit (Item No. ZK 04 03)
● 1” hose nozzle, brass, for suction end of wall unit (Item No. ZV 04 33)
● 1“ suction tube, flexible, max. operating pressure 20 bar (Item No. AS 20 03).
● 1“ hose clamps, made entirely of stainless steel (Item No. SS 0303).
● 1“ floating fine suction filter FFSF, with non-return valve (Item No. SZ 99 24).
● Wall or tube penetration WD 100, with 4 holes (1 x dia. 36 mm for suction line
1“, 2 x dia. 10 mm for electric cable, 1 x dia. 6 mm; Item No. WD 11 00).
Design and operating principle
The SIGMA rainwater unit draws rainwater from a storage tank and feeds it under pressure into the rainwater supply circuit. If the water level in the storage tank is low, the system automatically switches over to mains water operation.
A self-priming pump draws harvested rainwater out of the storage tank and pumps it to the appliances. If a valve at one appliance (e.g. toilet flushing sys­tem) is opened, the pressure in the rainwater supply circuit drops. The pump starts up when the pump starting pressure (1.5 bar) at the automatic switch is reached. When all valves at the appliances are closed again and there is no measurable flow through the circuit, the pump control system (automatic switch) shuts down the pump when operating pressure is reached.
Switchover to mains water top-up is fully automatic provided that the float switch in the rainwater storage tank is securely attached to the inflow tube (in­flow calming) at a vertical height of 30 cm above the base of the tank. If this „minimum water level“ is reached, the float switch in the storage tank closes. (Mains) water is now sucked out of the top-up tank integrated in the SIGMA unit.
The drop in water level in the top-up tank causes the float valve to open to allow inflow of mains water into the top-up tank. In the rare occasion that the mains water that is supplied to the top up tank is coming in with a very low pressure, it can happen that the pump is drawing more water from the top up tank than can be simultaneously replaced with mains water. The Water level in the top up tank is falling until it reaches a low point 3 cm above bottom level. At this point a safety control switches the pump off until the water level in the top up tank has reached a height of minimum 13 cm again. When the Water Level is rising above this Level the pump is automatically switched on again. When the valves at all appliances are closed again, the pump control system shuts down the pump as soon as operating pressure is reached (= max. delivery head).
The automatic switch provides dry run protection when there is insufficient water in the circuit.
It is possible to manually switch the rainwater unit over to pure mains water operation while maintenance work is in progress or when water of a particularly quality is required. Manual switchover is possible irrespective of the fill level in the rainwater storage tank. Mains water operation can be selected by means of an electric switch on the side of the automatic switch. If the switch is turned on, the self-priming pump automatically extracts water from the mains water top-up tank when an appliance valve is opened.
Supply with rainwater
7
ZETA 02 Programming
Note:
The “Reset” button on the Zeta 02 serves two functions, if pressed for less than 1 sec. it will go into reset mode, pump starts running. If pressed for longer it will go into one of the programming modes below
Programming Run-on-time. Mode 1 – Fast Flash
To Enter – Press and hold reset button (3 secs). Then briefly press reset button to toggle between settings.
To save the setting press and hold the reset button until the power light stops flashing (approx. 3 secs.)
FAST FLASHING
OFF
OFF
FAST FLASHING
ON
OFF
FAST FLASHING
OFF
ON
FAST FLASHING
ON
ON
10 sec Run-on-time
5 sec Run-on-time (Default and
recommended setting for normal use)
3 sec Run-on-time
1 sec Run-on-time
Programming excess pump run and starts functions Mode 2 – Slow Flash
To Enter – Press and hold reset button (6 secs). Then briefly press reset button to toggle between settings. D = Excess pump run function D on – Pump stops after 10 minutes continuous run. (May need to leave this off for some irrigation applications). T = Excess pump starts function. T on – Pump stops after 25 starts per hour. (Where multiple starts are occurring, we would recommend installing a
pressure vessel).
Save the setting by pressing and holding the reset button until the power light stops flashing (approx. 3 secs.)
IF either of these functions has switched the pump off, THEN the fault light (only) will show. IF the fault light AND the power light show then this indicates that a “Dry Run” type fault has occurred. (i.e. No flow arrived at the zeta 02 when the pump power was on)
SLOW FLASHING
OFF
OFF
SLOW FLASHING
ON
OFF
SLOW FLASHING
OFF
ON
SLOW FLASHING
ON
ON
D off (Default)
D off
D on
D on
T off (Default)
T on
T off
T on
8
Connect the emergency overflow DN 70
! !
Rinse piping and hoses
Note the length, height difference and continuous rise of the suction line from the storage tank base up to the Sigma unit!
SIGMA with level indicator
Installation requirements
The SIGMA system must be installed by specially trained installation personnel, i.e. by properly qualified, approved installation specialists and electricians. This is a basic requirement for maintaining the validity of the manufacturer‘s guaran­tee.
The SIGMA unit must be installed above the backflow level in a frost-free room which has a floor drain. Special measures must be implemented if the unit is installed and operated below the backflow level. Please contact WISY AG‘s technical support team for advice about installation below backflow level.
The suction tube must be installed with a continuous rise up to the SIGMA wall unit. The tube must have an inside diameter of at least 1“ (2.54 cm).
With a height difference of 3 m between the tank base and the SIGMA unit, a suction line of up to 15 metres in length might be required (maximum values).
For a SIGMA unit with level indicator, the measuring lead (for the level indicator) must be installed with a continuous rise up to the wall unit.
The emergency overflow (DN 70) of the mains top-up tank must be permanently and securely connected to a drain (minimum DN 70). The room in which the SIGMA unit is installed must have a floor drain.
The water column between the bottom edge of the wall unit and the highest operating point (valve at appliance) must not exceed 15.0 m.
The wall unit and the supply lines must not be installed in locations which are exposed to substantial heat sources, as temperature rises in these components can cause the system pressure to increase and result in component damage.
Piping or hoses must be cleaned or flushed through before use to remove any deposits of dirt/dust caused by building work. Protective plugs must be remo­ved before pipes or hoses are connected.
Attention to backflow level and floor drain in the installation area
9
Connection to the indoor pipework
Installation of components in the rainwater storage tank
Installation
Line up the wall mounting kit horizontally and attach it to the wall. The wall­mounting bracket can be used as a drilling template. The distance between the holes is 28 cm. The wall unit can then be inserted in the groove of the bracket.
The connection between the wall unit and the rainwater supply circuit / mains water pipe must be high pressure resistant, flat-sealing and acoustically isola­ted. The ball valve with dirt trap (accessory hose connection set RW 78 00) must be used to connect the rainwater unit to the mains water pipe.
Clamp the float switch to the inflow calming tube in the rainwater storage tank at a vertical distance of between 30 and 35 cm from the tank base.
Attach the floating fine suction filter with the stainless steel hose clamp to the suction hose in the storage tank.
Route the electric cable for the float switch and the suction hose (and possibly the measuring lead for the level indicator) through a service duct into the utility room of the building.
Fill the suction hose with water, then attach it with hose nozzle and isolating valve to the suction end of the SIGMA wall unit with a hose clamp.
Do not install any flow restrictions (water meters, filters, drain cocks, etc.) in the SIGMA suction line.
Mains connection protected by RCD
The mains power connection (AC, single-phase, 230 V, 50 Hz) of the SIGMA rainwater unit must be equipped with a residual current device (0.03 A) and protected by a 16 A fuse.
Wire up the connecting cable of the float switch to the plug supplied. See photo­graph on left for correct termination of wires. Insert the plug into the grey socket outlet which is located on the underside of the wall unit.
All electrical work must be carried out in accordance with the safety instructions given on page 5.
Install the wall unit inside the building
top
rear panel
of casing
Note height of top edge of unit
Electrical connection of indoor wall unit
blue yellow/green
black, grey or brown
Insert
Commissioning the SIGMA
1. Completely fill the pump unit and the suction hose with water. The suction hose can be filled directly, but the pump must be filled with water by opening the screw plug.
2. Open the isolating valve in the mains top-up pipe. The top-up tank fills up with mains water.
3. Open the valves at the appliances.
4. Connect the SIGMA to the electricity supply.
5. As soon as system has been bled, close the valves at the appliances! When the maximum operating pressure is reached (maximum delivery head, see technical data), the SIGMA is ready to operate.
Power plug for float switch
10
Applications
Mounting location
Installation instructions for measuring lead
Connect yellow measuring lead to connector on the underside of the SIGMA wall unit
Universal, pneumatic fill level meter with capsule-type element and integrated electric pump for measuring fill levels in tanks. Steplessly adjustable to tank heights of between 100 cm and 250 cm (adjustable by the hexagon socket head screw); zero-point calibration of needle (adjustable by the Phillips-head screw). Measuring accuracy of the measurement mechanism is +/- 3% of full scale value. The electrically operated pump closes the measuring system at the top dead point. The needle remains stationary briefly and then drops very slowly down. The water stop air cushion produced in this way protects the capsule element.
Universal connection for the measuring lead (PE tube) with 8 mm outer diameter. Fill level is indicated in % irrespective of the tank shape.
Standard application is for water level height in the storage tank of between 100 and 250 cm and distances of around 10 m between the SIGMA wall unit with fill level meter and the rainwater storage tank (measuring lead length 13 m). Positi­on of normal use is vertical. Ambient temperature: 0°C to +40°C.
Protected against direct exposure to weather and solar radiation.
Install the measuring lead (yellow PE tube) with a continuous fall towards the tank. Do not bend the lead (to prevent water pockets!).
Install the rubber-insulated measuring lead with brass weight in the storage tank in such a way that it is suspended vertically and ends at approximately 5 cm above the tank base, then connect both tubes with the brass coupling.
To connect the measuring lead to the measuring instrument connector (on the underside of the SIGMA wall unit), assemble the individual components in the order illustrated in Figure 1 at the end of the yellow PE tube, insert the tube as far as it will go into the connector and gently tighten the hexagon bolt.
Device setting instructions
Remove the cover from the SIGMA unit.
Precisely adjust the measuring range (corresponds exactly to the maximum water fill level in the storage tank up to the overflow) on the adjustment scale using the hexagon socket head screw (failure to do this properly will result in measuring errors!).
Use the zero-point calibration screw to position the needle at „0“. Turn the screw by maximum one revolution to the left or right until the needle is pointing to „0“. If the tank has already been filled and the pump started, the measuring system will need to be „depressurized“ before the zero point can be calibrated. This can be done by detaching the measuring lead from the connector at the wall unit.
Description of level indicator unit
A measurement of the fill level of the storage tank is triggered only if the SIG­MA pump starts up. During the pneumatic measuring process, the hydrostatic pressure is measured. This varies depending on the water level in the tank. The pressure is generally measured at a height of 5 cm above the tank base and is converted to a fill level percentage on the clock dial.
The pump of the measuring instrument is used to build up pneumatic pressure in the measuring system until this pressure is equal to the water pressure applied to the base of the tank. The needle is now in its maximum position. The pressure generated by the pump has displaced the water column from the measuring lead suspended in the water (black rubber hose). Bubbles of air escape from the end of the hose on the tank base and the needle remains temporarily in the measurement position. Once the SIGMA has returned to its „normal position“, the needle gradually drops back to the „0“ position.
Description of function Level indicator
Scope of supply of basic equipment
SIGMA with level indicator
This description applies to installation of a pneumatic level indicator in the SIG­MA rainwater unit. The function descriptions of the measuring instrument, the installation instructions for the measuring lead and the device setting instruc­tions are all important.
PE measuring lead (yellow), a brass hose coupling, 3 m rubber-insulated tube (black) with brass weight and a connection kit for the measuring lead (small parts supplied in small plastic bag).
Replacement / extension kits, each containing 10 m of PE measuring lead with brass hose coupling, can be ordered (WISY Item No. FA 9915).
A connection kit includes:
1. Brass tubular rivet (as „support“)
2. Rubber seal
3. Hexagon bolt (black plastic) with hole to insert yellow measuring lead; is screwed into connector on wall unit
4. Yellow measuring lead
11
Indication errors and causes
● Needle does not move when measurement is taken / drops very quickly back to 0: Leak in connections or connecting lead, „depressurize“ the measuring system (see device setting instructions)! Hold a finger over the measuring instrument connector on the wall unit and start SIGMA by pres­sing the RESET button on the automatic switch (in wall unit)! If the needle moves to its maximum position, the measuring instrument and the connec­tions inside the wall unit up to the measuring instrument connector are OK. The connections and connecting lead must be inspected for leaks!
● Needle moves to beyond 100% position: The measuring lead is blocked or bent, or the measuring range is set incorrectly.
● Indication error: The device is incorrectly set. Check the fill level in the tank, correct on the adjustment scale!
Maintenance and servicing
Inspections/tests at 6-monthly intervals:
● Inspect the SIGMA system and the water circuit connections for leaks
● Check the system pressure indication
● Test the pump start and stop points at the automatic switch
● Test mains water operation, e.g. by setting the switch on the side of the au-
tomatic switch to „mains water mode“ and closing the isolating valve at the suction end
Inspections/tests at 12-monthly intervals:
● Inspect the dirt trap at the isolating valve of the mains water connection, clean the trap if required (call in a specialist if necessary)
● Inspect the floating fine suction filter in the rainwater storage tank and clean if necessary from ground surface level using a water jet or a long-handled brush (call in a specialist if necessary)
Replacement:
● The solenoid valve at the mains water outlet must be replaced by a specialist after the system has been in operation for 10 to 15 years.
Repairs
All repair work must be carried out by the manufacturer or by contractors who have been explicitly approved by the manufacturer. Repairs, modifications to components or modifications to factory-assembled SIGMA components carried out by unauthorized persons shall invalidate the guarantee!
The SIGMA rainwater unit must be disconnected from the mains power supply before any maintenance work is carried out on the open storage tank. Compliance with the safety instructions (see heading „Safety instructions“ in this document) is absolutely essential!
!
Environmental guidance
The SIGMA rainwater unit is shipped in recyclable cardboard packaging. Please recycle it as waste paper! Please take the Styropor packaging to your local recycling centre.
Waste electrical and electronic equipment often contains valuable materials which can be reused / recycled. However, they also contain harmful substances which are essential to the proper, safe operation of the equipment.
These substances pose a risk to human health and to the environment if the products are disposed of as general (non-recyclable) household waste or are incorrectly handled. For this reason, you must never dispose of an old unit as general (non-recyclable) household waste.
Use the recycling centres / facilities provided in your area to return defective electrical or electronic equipment so that it can be recycled!
Disposal / recycling of transport packaging
Disposal / recycling of old units
12
Troubleshooting guide
Type of fault Cause Remedy
SIGMA is not supplying water to the appliance(s)
a) Rainwater storage tank is empty, isolating
valve to mains water pipe is closed The dry run protection function of SA 06 is active
b) The pump is sucking in air through the
suction line
c) Automatic switch SA 06 is not starting the
pump d) The pump is blocked e) The power supply is interrupted
a) Open the isolating valve, bleed the SIGMA
unit and the entire rainwater circuit, start the pump by pressing the RESET button on the automatic switch (SA 06)
b) Check that the suction line and the floating
fine suction filter (FFSF) are correctly posi­tioned and leak-tight; correct if necessary; bleed the system
c) Press the RESET button! Call customer
service d) Call customer service e) Check the electrical connection, contact
customer service if necessary
The automatic switch SA 06 is switching the pump on and off continuously
a) Leak in the system, valves at appliances
are not fully closed
b) Automatic switch is soiled internally/ is
defective
a) Check the valves at appliances and the
rainwater supply circuit for leaks
b) Call customer service
Frequent switching of the pump causes pump damage – disconnect SIGMA from the power supply
Pump is running continuously a) Water loss of more than 0.7 l/min from
the system
b) Electronic circuitry (PCB) of the SA 06
is defective / SA 06 switch is defective
a) Check the valves at appliances and the
rainwater supply circuit for leaks
b) Replace the PCB or the SA 06 switch
(customer service)
Pump is not producing enough pressure a) The floating fine suction filter / filter casing
of the FFSF is dirty
b) The pump is sucking in air
through the floating fine suction filter (FFSF)
c) The pump is defective
a) Clean the floating fine suction filter (FFSF)
with a water jet or a fine brush
b) Check the position of the floating fine
suction filter in the storage tank and
correct if necessary
c) Call customer service
The residual current device has tripped a) Water or moisture on electrical
components
b) SA 06 is not operating
c) The pump or pump cable is defective
d) The float switch or float switch cable is
defective
a) Check the electric cable at the SA 06, the
cable between the pump and the SA 06
and the cable with plug to the float switch,
call customer service if necessary
b) Check the power supply and, if necessary,
the PCB / SA 06, customer service!
c) Call customer service
d) Call customer service
Continual top-up with mains water even when the water level in the rainwater storage tank is sufficient
a) Movement of the float switch in the storage
tank is hindered, i.e. it cannot float
b) The solenoid valve at the mains water
outlet is not closing
a) Inspect the float switch, remove the
blockage (customer service) b) Perform a function test on the solenoid
valve, replace if necessary, call customer
service
Switchover from rainwater operation to mains water operation is not working and the automatic switch is indicating a fault
a) The float valve in the mains water top-up
tank is blocked or is not opening
b) The float switch in the storage tank is
blocked
c) The float switch is not transmitting any
signals to the solenoid valve
a) Perform a function test on the float valve,
clean it if necessary, call customer service
b) Perform a function test on the float switch
(customer service)
c) Check the float switch, replace if
necessary (customer service)
Mains water is continuously running out through the emergency overflow of the mains top-up tank (audible!)
The float valve in the mains top-up tank is not closing
Check the valve; call customer service
Inadequate top-up with mains water, the dry run protection function is active
The float valve for mains water top-up is blocked or the dirt filter at the valve inlet is clogged
Clean the float valve or the dirt filter, replace if necessary, customer service
The pressure gauge (pressure indicator) is showing a raised pressure
An external heat source (e.g. radiator) is cau­sing a pressure rise in the SIGMA rainwater supply circuit
a) Remove the heat source (if possible) b) Contact customer service of your
installation company (it might be necessary
to install a pressure relief valve)
SIGMA units with level indicator:
The indicated fill level does not match the actual fill level in the storage tank
See also section headed „SIGMA with level indicator“
a) Basic setting error
b) Measuring lead is defective / not leak-tight
c) Level indicator is defective
a) Refer to operating instructions under
heading „SIGMA with level indicator“,
„Device setting instructions“ b) Contact customer service of your installati-
on company if necessary c) Contact customer service of your installati-
on company
TW = Trinkwasser
13
Technical data
SIGMA 3 SIGMA 4
Power consumption
Motor power P1 (W)
Solenoid valve (W)
Standby consumption
600
8
< 0,2 W
800
8
< 0,2 W
Mains connection
1-phase AC
230 V, 50 Hz 230 V, 50 Hz
Rated current (A) 2,7 3,5
Degree of protection
Aspri suction pump
ZETA 02
Solenoid valve
Float switch
IP 55
IP 44
IP 65
IP 68
IP 55
IP 44
IP 65
IP 68
SIGMA water connections:
Inlet connection from rainwater storage tank
Mains water connection
Outlet connection to appliances
(OT=outside thread, IT= inside thread)
1“ AG
¾“ AG
1“ AG
1“ AG
¾“ AG
1“ AG
Sound pressure level dB (A)
in decibels in
rainwater operation
mains water operation
45
63
47
63
Delivery head H
max
(m)
Flow rate Q
max
(l/min)
33
65
44
65
Operating data
Max. operating temperature (°C)
Max. water temperature (°C)
Max. startup frequency per hour
Pumped fluids
40
35
20
0.28 mm / 0.44 mm
finely filtered rainwa-
ter, mains water (clear
water containing no
aggressive or abrasive
substances)
40
35
20
0.28 mm / 0.44 mm finely filtered rainwa­ter, mains water (clear water containing no aggressive or abrasive substances)
Max. operating pressure (bar) 10 10
Electric connecting cables
Float switch
ZETA 02 (SIGMA mains cable)
15 m, bare cable end
(3 x 1 mm
2
)
1.4 m, with plug
(3 x 1 mm
2
)
15 m, bare cable end (3 x 1 mm
2
)
1.4 m, with plug (3 x 1 mm
2
)
Materials
Suction pump of SIGMA 3 and 4 systems
●Suction and discharge casings made of dezincification resistant brass
●Pump casing and impellers made of stainless steel AISI 304
●Shaft made of stainless steel AISI 420
●Carbon / ceramic mechanical seal
●Diaphragms made of glass-fibre reinforced Noryl
®
●Motor enclosure made of light metal L-2521
Automatic switch
●Polyamide, polypropylene (casing)
Mains water top-up tank
●Polystyrene (tank)
●Float valve made of KTW-approved plastic
Screw connections, pump connections
●Brass, stainless steel
Connecting hoses
●Natural rubber with stainless steel braiding
SIGMA rainwater unit casing
●Stainless steel (base frame)
●Polystyrene (cover)
Float switch
●Polypropylene (casing)
●Polyamide, PG 11 (cap nut)
●Neoprene cable
14
Declaration of Conformity
WISY Rainwater Harvesting
Product name
Applicable EU Directives
Angewandte harmonisierte Normen
Other applied national standards and specifications
Manufacturer
Authorised person with responsibility for technical documentation
Kefenrod, 14. Februar 2013
As defined by the EU Machinery Directive 2006/42/EC, Annex II, Part 1, Section A
We hereby declare that the machinery specified below conforms to all requirements of the EU Machinery Directive 2006/42/EC.
Multimat rainwater units, type 205, type 407 Optima 4, Optima 5, Optima Plus rainwater units Maxima rainwater units, type 205, type 407 Sigma 3, Sigma 4 rainwater units Delta rainwater unit
Machinery Directive 2006/42/EC of 17.05.2006
Electromagnetic Compatibility Directive 2004/108/EC of 15.12.2004.
EN ISO 13849-1:2008 Safety of machinery –Safety-related parts of control systems - Part 1: General principles for design (ISO 13849-1:2006)
EN 809:1998+A1:2009 Pumps and pump units for liquids. Common safety requirements.
EN ISO 12100:2010 Safety of machinery: General principles for design – Risk assessment and risk reduction (ISO 12100:2010)
EN 60204-1:2006 Safety of machinery – Electrical equipment of machines – Part 1: General requirements
EN 60529 (VDE 0470-1) Degrees of protection provided by enclosures
DIN 1989 Rainwater harvesting systems, Parts 1+4 DIN EN 1717 and DIN 1988-100 Protection against pollution of potable water installations
WISY AG Oberdorfstraße 26 D-63699 Kefenrod
WISY AG Oberdorfstraße 26 D-63699 Kefenrod
Arnold Denk
Managing Board
of WISY AG
Jan Maurer
Managing Board
of WISY AG
15
Guarantee
This guarantee is valid for a period of 24 months and becomes effective on the date of purchase by the system operator. Replacement of the product under guarantee will not extend the original period of the guarantee.
WISY shall meet its guarantee obligations for the rainwater unit if it can be demonstrated that the following conditions are fulfilled:
1. The product has been purchased from a specialist WISY retailer.
2. The product has been commissioned by the WISY customer service or by a specialist company.
Claims can be made under the guarantee only if WISY receives notification in writing of any defect within 14 days of discovery of the defect.
During the guarantee period, WISY shall repair or replace free of charge any defective part. Additional claims for damages shall be excluded to the extent permitted by law.
Faults or defects which arise as a result of the following factors are not covered by the guarantee:
● Faulty assembly or installation, e.g. failure to comply with the valid VDE regulations or the operating instructions.
● Failure to provide a floor drain in the utility room/installation area.
● Inappropriate use or exposure to excessive mechanical strain.
● The connection of equipment other than the pump / float switch supplied
with the SIGMA system to the socket provided on the SA 06 automatic switch / socket outlet of the float switch.
● External influences, e.g. shipping damage, damage caused by shock im­pacts, damage caused by exposure to weather, damage caused by soiling, damage caused by other natural phenomena.
● Repairs or modifications undertaken by unauthorized third parties.
Period and commencement of the guarantee
Terms and conditions of the guarantee
Content and scope of the guarantee
Limitation of the guarantee
OT Hitzkirchen Oberdorfstraße 26 D-63699 Kefenrod
Telephone (++49) 60 54 - 91 21-0 Telefax (++49) 60 54 - 91 21-29 E-Mail info@wisy.de Internet www.wisy.de
Sales
Telephone (++49) 60 54 - 91 21-33 Telefax (++49) 60 54 - 91 21-29
Ordering/Billing
Telephone (++49) 60 54 - 91 21-25 Telefax (++49) 60 54 - 91 21-28
Technical Support