Wiremold S175BLK, S175BRN, S165BLK, S165BRN, S165B Installation Manual

...
Page 1
WIREMOLD
Service Fittings
®
Infloor System Activations
Source I® Series Flush Activations offer a wide variety of single service power and communication activations for infloor distribution systems. Source I fittings are available in brass or in black or brown polycarbonate finishes. They are ideal for new construction and retrofit projects and can be used as presets or aftersets with Walkerduct® and Walkercell® systems.
Source I Single-Gang Flush
Service Fittings in brass.
FEATURES & BENEFITS
n Preset or afterset capability offers flexibility. Source I
Activations can be installed as preset or afterset activations providing future flexibility.
n Unique lock feature on duplex plates. Duplex device
plate has lid covers that can be locked when receptacle is not in use. Protects receptacle from damage.
n “Plug-thru” membrane receptacle cover. Receptacles
are protected by a dust blocking “plug-thru” membrane that protects receptacle from damage.
n Attractive low profile fittings. Flush feature compliments
office interior while providing functional services.
FIBER OPTIC CAT5
n Configure service fittings as needed. Flanges and
faceplates are ordered separately to create the desired activation unit that can be modified as future power and communication requirements change.
n
Datacom connectivity options. Accepts industry standard
and proprietary devices from a wide range of manufacturers to provide a seamless and aesthetically pleasing interface for voice, data, audio, and video applications at the point-of-use.
n cULus Listed. All Source 1 Series Flush Activations are
UL Listed to U.S. and Canadian safety standards.
Source I Series Nonmetallic Single-Gang Flush Service Fitting.
ED785R10 – Updated October 2015 – For latest specs visit www.legrand.us/wiremold
Page 2
Source I Series Flush Activations Ordering Information
Catalog No./Item Description/Specifications
S175BLK Double Duplex Power S175BRN Activation – Double duplex
1/4" [6.4mm]
Flange Thickness
activation available in black (S175BLK) or brown (S175BRN) polycarbonate assembly, 7/8"
4 3/4"
[121mm]
S165BLK Complete Flush Activation S165BRN Flush polycarbonate power –
5 3/4"
[146mm]
1/4" [6.4mm]
Flange Thickness
to 3 3/8" [22.2mm to 86mm] concrete topping. 15A, 125V receptacles included.
single duplex black (S165BLK) or brown (S165BRN). 15A, 125V receptacles included.
5 3/4"
[146mm]
S165B Complete Flush Activation
5/16" [7.9mm]
Flange Thickness
[121mm]
4 3/4"
Flush brass power – single duplex flip lids. May be used with 106 type adapters for data applications.
5 3/4"
4 3/4"
[121mm]
S166BLK Complete Flush Activation S166BRN Flush polycarbonate
[146mm]
1/4" [6.4mm]
Flange Thickness
communication slides available in black (S166BLK) or brown (S166BRN.
5 3/4"
[146mm]
S166B Complete Flush Activation
Flange Thickness
[121mm]
5/16" [7.9mm]
4 3/4"
Flush brass communication (slides). Used for data cable pass-through.
5 3/4"
[146mm]
S124BLK Carpet Flange – Flush S124BRN polycarbonate carpet flange
4 3/4"
[121mm]
1/4" [6.4mm]
Flange Thickness
only with mounting screws. Available in black (S124BLK) or brown (S124BRN).
4 3/4"
[121mm]
S124B Carpet Flange – Flush brass
5 3/4"
[146mm]
5/16" [7.9mm]
Flange Thickness
carpet flange only with mounting screws.
4 3/4"
[121mm]
5 3/4"
[146mm]
Catalog No./Item Description/Specifications
S125B Cover Plate – Flush brass
power cover plate only (flip lid) with four mounting screws
3 1/8"
[80mm]
4 1/8"
[105mm]
S125BLK Cover Plate – S125BRN Nonmetallic double duplex
membrane cover plate.
4 1/8"
[105mm]
Available in black (SL125BLK) or brown (S125BRN).
3 3/16"
[81mm]
S130BLK Cover Plate – Nonmetallic S130BRN double duplex membrane
cover plate. Available in black (S130BLK) or brown S130BRN)
3 3/16"
[81mm]
4 1/8"
[105mm]
829PSTC-BLK Cover Plate – Flush 829PSTC-BRN polycarbonate communication
cover plate with slides and four mounting screws. Black (829PSTC-BLK) or brown (829PSTC-BRN).
3 3/16" [81mm]
4 1/8"
[105mm]
829STC Cover Plate – Flush brass communication cover plate with slides and four mounting screws.
3 1/8"
[80mm]
4 1/8"
[105mm]
829CK
Cover Plate –
Flush brass communication cover plate (2 5/8" and 2 1/4" diameter trade size screw plugs) with four mounting screws.
3 1/8"
[80mm]
829CK-3/4
4 1/8"
[106mm]
Cover Plate –
Flush brass communication cover plate (2 5/8" and 3/4" diameter trade size screw plugs) with four
4 1/8"
mounting screws.
3 1/8"
[80mm]
829CK-1/2
[106mm]
Cover Plate –
Flush brass communication cover plate (2 5/8" and 1/2" diameter trade size screw plugs) with four mounting screws.
3 1/8"
[80mm]
4 1/8"
[106mm]
2
Page 3
Source I Series Flush Activations Ordering Information (continued)
Catalog No./Item Description/Specifications
829CK-1 Cover Plate – Flush brass communication cover plate (2 5/8" and 1" diameter trade size screw plugs) with four mounting screws.
3 1/8"
[80mm]
4 1/8"
[106mm]
Catalog No./Item Description/Specifications
439 Attaching Ring – For
polycarbonate afterset use only. No adjusting ring required. 4" [102mm] O.D. Four #6-32 hold-down screws provided.
4" [102mm]
Diameter
7/8
[22.2mm]
828SPTC Cover Plate – Flush brass
communication cover plate. 1 1/2" diameter trade size screw plugs.
3 1/8"
[80mm]
4 1/8"
[105mm]
437 Attaching Ring – Attaching
Rings for Source I (Preset or Afterset) zinc die-cast. 4" [102mm] O.D. Add suffix to Cat. No. to indicate ring
4" [102mm]
depth: 7/8", 1 1/8", 1 1/2", 2",
Diameter
2 3/8", or 3 1/8".
S1MC Mudcap – For Source I 437 Attaching Ring. 4" [102mm] O.D.
4" [102mm] Diameter
1/2"
[12.7mm]
S1MC-MS Mudcap – For Source I
Attaching Ring with marker screw. 4" [102mm] O.D. Use with 437 Attaching Rings only.
897AR Adjusting Ring Adjusting ring (with three adjusting screws) for use with 437 Attaching Rings – power for brass fitting only. 3 25/32" [96mm] O.D.
3 3/4" [95mm] Diameter
3/4"
[19.1mm]
898AR Adjusting Ring – Adjusting ring (with three adjusting screws) for use with 437 Attaching Rings – communication only (brass and polycarbonate fittings) and power for polycarbonate fitting only.
3 3/4" [95mm] Diameter
3 25/32" [96mm] O.D.
3/4"
[19.1mm]
S1ER Attaching Ring Extension Extension ring – mounts on top of 437 Attaching Ring. Includes extension ring and three mounting screws. 4" [102mm] O.D. Add suffix to indicate ring height: 7/8", 1 1/8", 1 1/2", 2", 2 3/8", 3 1/8". We recommend using a shallow Attaching Ring
4" [102mm] Diameter
and deep extension ring whenever possible.
437 Preset Insert Installation Guidelines
Drill 2 1/2" [64mm] hole in duct where activation is desired. Install attaching ring in hole in raceway before concrete is poured. Attaching ring is secured by tightening locking tabs. Be sure the locking tabs are oriented lengthwise with the raceway. The mudcap should be securely in place before the concrete pour. After the pour, chip away concrete and remove mudcap. Attach 437 Ring, 897/898AR Ring and Service Fitting (not shown).
NOTE: 437 Attaching ring can be
used as a preset or afterset.
S1MC Mudcap
No. 2 Duct
437 Attaching Ring
439 Afterset Insert & Polycarbonate Source I Fitting
Duplex Plate with Membrane S130BLK/BRN
Carpet Flange S124BLK/BRN
439 Attaching Ring
3
Page 4
Source I Series Flush Activations Installation Diagrams
S175 Double Duplex Power Activation
1.
Establish location for the fitting, then core drill a 4" [102mm] diameter hole through the concrete to the top of the duct.
2.
Next, drill a 2 1/2" [64mm] diameter opening in the top of the duct, making sure this opening is in the center of the 4" [102mm] hole.
3.
Install the 439 Attaching Ring using the two locking tabs to secure it to the duct.
4.
Connect the carpet flange to the attaching rings using the four screws provided.
5.
Install the two duplex receptacles and the double duplex plate to complete the installation.
4" [102mm] Core
Drilled Hole
2 1/2" [64mm]
Dia. Hole
Duct
439 Attaching
Ring for use with
Polycarbonate
Fittings Only
and Only as an
Afterset.
Carpet Flange
Double Duplex
Plate with
Membrane
Activation Guidelines – Flush Using 437 Ring
Pull wires through the hole in the
1.
bottom of the attaching rings. The adjusting ring should then be installed at the desired height. Wire device and attach to the adjusting ring.
After the gasket is put in place,
2.
attach the flange to the adjusting ring. For Power: The flip lid cover plate can be attached to the flange.
3.
For Communication: Turn self
storing slides upside down with thin edge to the inside. Attach cover plate to flange.
Neoprene Gasket
Communication Cover Plate 829STC (Shown) or 829PSTC-BLK/BRN
Wiring Device Adjusting Ring 897AR for Power (Shown) 898AR for Communication
Attaching Ring
Power Cover
Plate S125B
Carpet Plate
S124B (Shown)
or
S124 BLK/BRN
Polycarbonate — Using a 439 Afterset Attaching Ring
1.
Establish location for the fitting, then core drill a 4" [102mm] diameter hole through the concrete to the top of the duct.
2.
Next, drill a 2 1/2" [64mm] diameter opening in the top of the duct, making sure this opening is in the center of the 4" [102mm] hole.
3.
Install the 439 Attaching Ring, using the two locking tabs to secure it to the duct.
4.
Connect the carpet flange to the attaching ring, using the four screws (#6-32 flathead) provided.
5.
For duplex cover plate: Install the wiring device onto the carpet flange and secure the cover plate over it, making sure the plug-through membrane is in place.
For communication cover plate: Reverse the communication slides as necessary to allow cable egress, and install the cover plate, taking care to avoid pinching any cables.
NOTE: The receptacle mounting shelf can be
broken out to create additional cable space when the communication cover plate is used.
4" [102mm] Core Drilled Hole
Duct 2 1/2" [64mm] Dia. Hole
439 Attaching Ring for Use with Polycarbonate Fittings
Only and Only as an Afterset
Carpet Flange
S124BLK/BRN
Duplex Plate with
Membrane S130BLK/BRN