Wiremold 30TC-2V, 30TP-2V Installation Manual

Page 1

Wiremold® Tele-Power® Poles Poteaux Tele-Power® Barras Tele-Power®

Installation Instructions • Notice d'Installation• Instrucciones de Instalación

Catalog Number(s) • Numéro(s) de Catalogue • Número(s) de Catálogo: 30TC-2V, 30TP-2V

Country of Origin: Made in USA • Fabriqué en USA • Hecho en USA

IMPORTANT:

No: 1011593 - 06/14

Please read all instructions before beginning installation

Legrand electrical systems conform to and should be properly grounded in compliance with requirements of the current National Electrical Code or codes administered by local authorities.

All electrical products may present a possible shock or fire hazard if improperly installed or used. Legrand electrical products may bear the mark of a Nationally Recognized Testing Laboratory and should be installed in conformance with current local and/or the National Electrical Code.

IMPORTANT :
VEUILLEZ LIRE L'ENSEMBLE DES INSTRUCTIONS AVANT DE COMMENCER L'INSTALLATION.

Les systèmes électriques Legrand sont conformes au Code National de l'électricité (National Electrical Code) ou aux codes locaux en vigueur et doivent être mis à la terre conformément à ces codes.

Tous les produits électriques peuvent présenter un risque d'électrocution ou d'incendie s'ils ne sont pas installés ou utilisés correctement. Les produits électriques Legrand peuvent porter la marque d'un laboratoire reconnu et doivent être installés conformément au Code national de l'électricité et/ou aux codes locaux en vigueur.

IMPORTANTE:

30TP-J

(1.59" [40.39mm])

30TD-I

Lea todas las instrucciones antes de comenzar la instalación.

Los sistemas eléctricos Legrand cumplen con los requisitos del Código Eléctrico Nacional (National Electrical Code, NEC) actual o con los códigos impuestos por las autoridades locales y deben conectarse a tierra consecuentemente.

Todos los productos eléctricos pueden presentar un riesgo de descarga o incendio si se los instala o utiliza incorrectamente. Los productos eléctricos Legrand pueden llevar la marca de un laboratorio de pruebas reconocido a nivel nacional y se deben instalar conforme al código local en vigencia o al Código Eléctrico Nacional.

* 30TC-2V Series not intended for combining power and communications in the same channel * Avec la série 30TC-2V, il n'est pas prévu d'associer l'alimentation et la communication dans

le même conduit.

* La Serie 30TC-2V no está diseñada para combinar alimentación eléctrica y comunicaciones en el mismo canal.

Page 2

WIRE FILL CAPACITY CHARTS

RACEWAY WI RE AND CABLE F ILL CAPA CITIES FOR TELE-POWER F POLES - POWER
Cable
Type
Cable Wire/Size
Description
C
(inches)
).D.
[mm]
30TP-2V
Series
30TC-2V*
Series
40% FILL 40% FILL 40% FILL 40% FILL
THHN / THWN 10 Awg 0.16 4.17 10 10
12 Awg 0.13 3.30 15 15
RACEWA RACEWAY WIRE AND CABLE FILL CAPACITIES FOR TELE-POWER POLES - COMMUNICATIONS
Cable
Type
Cable Wire/Size
Description
O.D.
(inches) [mm]
30TF
Ser
20% FILL
P-2V
ies
40% FILL
30TC-2V
Series*
20% FILL 40% FILL
Unshielded Cat. 5 UTP 0.22 5.59 14 28 18 37
Twisted Pair Cat. 3 UTP 0.19 4.83 19 38 25 50
Telephone 2 Pair 0.14 3.56 35 70 46 90
3 Pair 0.15 3.81 30 61 40 79
4 Pair 0.19 4.83 19 38 25 50
25 Pair 0.41 10.41 4 8 5 11
Coaxial RG58/U 0.20 4.95 18 36 24 47
RG59/U 0.24 6.15 12 23 15 31
RG62/U 0.24 6.15 12 23 15 31
RG6/U 0.27 6.86 9 19 12 25
TwinAxial 100 Ohm 0.33 8.38 6 13 8 16
Shielded
Twisted Pair
Type 1 STP
Type 2 STP
Type 3 STP
0.39
0.47
0.25
9.91
11.81
6.22
4
3
11
9
6
23
6
4
15
12
8
30
Fiber Optic Fiber ZipCord 0.11 2.79 56 113 74 14
Round Fiber 2 Strand 0.18 4.57 21 42 28 55
Round Fiber 4 Strand 0.19 4.83 19 38 25 50
Round Fiber 6 Strand 0.21 5.33 15 31 20 41

* 30TC-2V Series not intended for combining power and communications in the same channel.

TABLEAUX DES CAPACITÉS DE REMPLISSAGE EN TERMES DE FILS
CAPACITÉS DE REMPLISSAGE EN TERMES DE CÂBLES ET DE FILS DES CHEMINS
DE CÂBLES POUR LES POTEAUX TELE-POWER – ALIMENTATION
Type
de câble
Description de la
taille/des fils du
D .E.
mm
Série
30TP-2V
Série
30TC-2V*
câble REMP. 40 % REMP. 40 % REMP. 40 % REMP. 40 %
THHN / THWN 10 Awg 0.16 4.17 10 10
12 Awg 0.13 3.30 15 15
CAPACITÉS CAPACITÉS DE REMPLISSAGE EN TERMES DE CÂBLES ET DE FILS DES CHEMINS DE CÂBLES POUR
LES POTEAUX TELE-POWER – COMMUNICATION
Type de Description
la Taille/des fils
D.I Ξ. 30TP-2V
Série
30TC-2V
Série*
câble du câble (pouces) [mm] REMP. 20 % REMP. 40 % REMP. 20 % REMP. 40 %
Paire torsadée
non blindée
UTP cat. 5
UTP cat. 3
0,22
0,19
5,59
4,83
14
19
28
38
18
25
37
50
Téléphone 2 paires
3 paires
4 paires
25 paires
0,14
0,15
0,19
0,41
3,56
3,81
4,83
10,41
35
30
19
4
70
61
38
8
46
40
25
5
90
79
50
11
Coaxial RG58/U
RG59/U
RG62/U
RG6/U
0,20
0,24
0,24
0,27
4,95
6,15
6,15
6,86
18
12
12
9
36
23
23
19
24
15
15
12
47
31
31
25
Twinax 100 Ohms 0,33 8,38 6 13 8 16
Paire torsadée
blindée
STP type 1
STP type 2
STP type 3
0,39
0,47
0,25
9,91
11,81
6,22
4
3
11
9
6
23
6
4
15
12
8
30
Fibre optique Fibre ZipCord
Fibre ronde à 2 brins
Fibre ronde à 4 brins
Fibre ronde à 6 brins
0,11
0,18
0,19
0,21
2,79
4,57
4,83
5,33
56
21
19
15
113
42
38
31
74
28
25
20
14
55
50
41

* Avec la série 30TC-2V, il n'est pas prévu d'associer l'alimentation et la communication dans le même conduit.

Page 3

CUADROS DE CAPACIDAD DE PASO DE CONDUCTORES

CAPACIDADES DE PASO DE CONDUCTORES EN CONDUCTOS ELÉCTRICOS PARA BARRAS TELE POWER –
ALIMENTACIÓN ELÉCTRICA
Tipo de cable cable Descripción cant. Diámetro e o exterior Sorio 25DTD Series AMTC y 25DTC*
· conductores y tamaño del cable (pulgadas)
PASO
COND. 40 %
[mm]
PASO
COND. 40 %
Selle AMDIT Jene 200 IT Comp. pequeño Comp. grande
PASO
COND. 40 %
PASO
COND. 40 %
PASO
COND. 40 %
PASO
COND. 40 %
THHN / THWN 10 Awg 0.16 4.17 10 10 34 44
12 Awg 0.13 3.30 15 15 54 69
CAPACIDADES DE PASO DE CONDUCTORES EN CONDUCTOS ELÉCTRICOS PARA BARRAS TELE POWER - COMUNICACIONES
Series AMTC y 25DTC*
Tipo de cable Descripción cant. conductores y tama-
ño del cable
Diámetro interior
(pulgadas) [mm]
Serie
PASO
COND.
20 %
AMDTP
PASO
COND.
40 %
Serie
PASO
COND.
20 %
e 25DTP
PASO
COND.
40 %
Comp
PASO
COND.
20 %
. pequeño
PASO
COND.
40 %
Comp
PASO
COND.
20 %
. grande
PASO
COND.
40 %
Par trenzado Cat. 5 UTP 0.22 5.59 10 19 10 19 10 19 13 26
sin blindaje Cat. 3 UTP 0.19 4.83 13 25 13 25 13 25 17 35
2 Pares 0.14 3.56 23 47 23 47 23 47 32 64
Teléfono 3 Pares
4 Pares
0.15
0.19
3.81
4.83
20
13
41
25
20
13
41
25
20
13
41
25
28
17
56
35
25 Pares 0.41 10.41 3 5 3 5 3 5 4 7
RG58/U
RG59/U
0.20
0.24
4.95
6.15
12
8
24
16
12
8
24
16
12
8
24
16
17
11
33
21
Coaxial RG62/U
RG6/U
0.24 0.27 6.15
6.86
8
6
16
13
8
6
16
13
8
6
16
13
11
9
21
17
Axial retorcido 100 ohmios 0.33 8.38 4 8 4 8 4 8 6 12
Par trenzado Tipo 1 STP
Tipo 2 STP
0.39
0.47
9.91
11.81
3
2
6
4
3
2
6
4
3
2
6
4
4 8
6
con blindaje Tipo 3 STP 0.25 6.22 8 15 8 15 8 15 10 21
ZipCord de fibra óptica 0.11 2.79 38 76 38 76 38 76 52 104
Fibra óptica Fibra óptica, 2 hilos, sección circular 0.18 4.57 14 28 14 28 14 28 | 19 39
i ibra optica Fibra óptica, 4 hilos, sección circular 0.19 4.83 13 25 13 25 13 25 | 17 35
Fibra óptica, 6 hilos, sección circular 0.21 5.33 10 21 10 21 10 21 14 29

* Las Series 25DTC/AMTC no están diseñadas para combinar alimentación eléctrica y comunicaciones en el mismo canal.

Page 4

Loading...