In-Wall S-Video/Stereo Audio CAT5 Extender Manual A-1176
The A-1176 is the next step in the evolution of home theater and residential audio/video components. This module will provide crystal clear sound and pictures over long distances utilizing economical Category 5e or higher UTP cable.
SPECIFICATIONS:
Video: 1x S-Video female connector Audio: 2x RCA jacks for Le ft and Right Audio UTP: 110-type rear punchdown
Impedance:
Video: 100 ohm Unbalanced Audio: 600 ohm Unbalanced
Bandwidth:
Video: DC~12 MHz Audio: 50 Hz~15 KHz
Distance:
Audio/Color Video: Category 5e UTP cable up to
300 meters
IMPORTANT
Do not route audio/video cables through the same cable holes as the AC power cables. For safety, all audio/video cables sho uld be separated from parallel AC power lines by at least 6 inches whenever possib le. Avoid kinking the cable. Do not attach cable tie -downs too tightly. The cable fastening hardware should not compress the cable sheath. Do not bend the cable sharply. Be especially
careful to dress the cables properly after
passing them through a hole as the edges of the hole can compress or even damage the
cable sheath. Follow all warnings on the products. For your safety, do not use this or any electrical product near water (unless specifically designed for wet areas). Do not install wiring during thunder and lightning storms. Use caution when handling or installing any computer, telephone, video, or electrical devices.
INSTALL ATION
1. Strip off approximately 2" of the Category 5e cable jacket, using the appropriate cable stripping tool.
2. Separate the pairs according to color (Brown/ Brown-White, Green/Green-White, Orange/ Orange-White, and Blue/Blue-White).
3. To terminate, place each wire into the insulation
displacement contacts (IDC) by matching the wire color with the applicable colors on the punchdown block.(see the figure below).
TIP: We recommend untwisting the pairs no more than 1"
from termination point.
4. If using a 110-type punchdown tool, place the tool over
each wire with the cutting blade facing outside of the IDC and punch down firmly.
5. Repeat this process with each pair.
6. Install included termination caps firml y onto the IDC.
7. Fasten insert and wallplate to electrical box using
supplied screws.