Winning Home WH100022 Quick Guide

DIN-Rail 8-Channel Relay Switch
Wiring Guide
Supported model
• C4-DIN-8RELSW-E DIN-Rail 8-Channel Relay Switch
Diagrams color code*:
Black Line Red Load Grey Neutral Green Earth ground
Blue Ethernet
*Important! The wire colors shown in Figures 1 and 2 and in the “Diagrams color code” table are examples only. Actual wire colors dier by country and/or voltage.
Wiring diagrams
Use these Control4 DIN-Rail 8-Channel Relay Switch wiring diagrams along with the DIN-Rail 8-Channel Relay Switch Installation Guide ( install DIN-Rail 8-Channel Relay Switches.
ctrl4.co/8chrelay-ig
) to
Figure 1. Wiring in Control4 panel
Distribution
Override switch
(breaker)
panel
Load 1
Load 2
Line 1 Load 3 Load 4
Line 2
Load 5
Load 6
Line 3
Load 7
Load 8 Line 4
Aux Override In
Aux Override Out
Neutral Out 1
Neutral Out 2
Neutral In 1
Neutral Out 3 Neutral Out 4
Neutral In 2
Neutral Out 5 Neutral Out 6
Neutral In 3
Neutral Out 7 Neutral Out 8
Neutral In 4
Ground
Important: Remove the four bypass jumpers that connect each black terminal to two red terminals by unscrewing all three screws in each bypass jumper until the entire bypass jumper can be pulled out.
Load 1
Load 2
Neutral 1
Line 1
Load 3
Load 4
Neutral 2
Line 2
Load 5
Load 6
Neutral 3
Line 3
Load 7
Load 8
Neutral 4
Line 4
Aux in
Aux out
C4-DIN-8RELSW-E
8-Channel Relay Switch
Made in China/Fabriqué en Chine/中国制造
ATTENTION: Risque de choc électriqueNe pas ouvrir
undesired operation.
CAN ICES-3 (B)/NMB-3(B)
16A Max per Channel
1 HP Max per Channel @ 120V
2 HP Max per Channel @240V
Refer to documentation
for load ratings
Patent Pending
Prototype not for resale
To Ethernet switch
This device complies with part 15 of the FCC rules and ISED’s
license-exempt RSSs. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause
100-277V ,50/60 Hz
240V ,50 Hz
64A Max Total
16A Max per Circuit
Only Load 1 shown in detail
All modules sharing an auxiliary override switch must be on the same electrical voltage and phase.
Terminal block
Figure 2. Wiring in standard DIN rail panel
To Ethernet switch
Made in China/Fabriqué en Chine/中国制造
Load 1
Load 2
Neutral 1
Line 1
Load 3
Load 4
Prototype not for resale
Neutral 2
Line 2
ATTENTION: Risque de choc électriqueNe pas ouvrir
Load 5
Load 6
Neutral 3
This device complies with part 15 of the FCC rules and ISED’s license-ex­empt RSSs. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
CAN ICES-3 (B)/NMB-3(B)
Load 7
Line 3
Load 8
Neutral 4
Line 4
100-277V ,50/60 Hz 240V ,50 Hz 64A Max Total 16A Max per Circuit 16A Max per Channel 1 HP Max per Channel @ 120V 2 HP Max per Channel @240V Refer to documentation for load ratings Patent Pending
C4-DIN-8RELSW-E 8-Channel Relay Switch
Aux in
Aux out
Distribution
(breaker)
panel
control4.com | 888.400.4070
Copyright ©2019, Control4 Corporation. All rights reserved. Control4, the Control4 logo, the 4-ball logo, Control4 My Home, and Mockupancy are registered trademarks or trademarks of Control4 Corporation or its subsidiaries in the United States and/or other countries. All other names and brands may be claimed as the property of their respective owners. All specifications subject to change without notice.
200-00595-A.3
A
2019-01-15 LW