Winning Home WH100019, WH100018 Installation Guide

Decora Wired
KeyPad
KeyPad
V+
GNDD+D-V+GNDD+D-
To Bus Ethernet
Gateway
To Next Keypad
Keypad
Installation Guide
C4-KCB-XX Decora® Wired Keypad
Introduction
The Control4® Decora Wired Keypad is intended for use in a Control4 system. It installs in a standard US wallbox. Communication to the Control4 system is via RS­485 protocol and wiring. For RS-485 wiring topologies, refer to the Keypad Bus Wiring Guide (
Box contents
• Decora® Wired Keypad
• Keycap Button Kit
• Pluggable Terminal Block
• Warranty card
Specifications
Model number C4-KCB-XX
Power requirements 48VDC
Power consumption Maximum 48VDC 1.2W
Operational temperature 32˚F ~ 104˚F (0˚C ~ 40˚C)
Humidity 5% to 95% non-condensing
Storage -4˚F ~ 158˚F (-20˚C ~ 70˚C)
Control communications RS-485
Weight 0.1 lb. (0.045 kg)
Shipping weight 0.3 lb. (0.14 kg)
ctrl4.co/buswiring
).
Minimum 48VDC 0.7W
Environmental
Miscellaneous
Warnings and considerations
Important: Using this product in a manner other than outlined in this document voids your warranty. Further, Control4 is not liable for any damage incurred with the misuse of this product. See “Troubleshooting.”
Important: Do not use a power screwdriver to install this device. If you do, you may overtighten the screws and strip them. Also, overtightening the screws may interfere with proper button operation.
Important: This is an electronic device with intricate components. Handle and install with care!
Caution! Do not exceed the number of keypads per power supply as indicated in the Keypad Bus Wiring Guide. Exceeding the maximum number of keypads will result in overheating the wires and/or failed devices.
Installation instructions
Caution! When wiring the keypad, make sure that either:
• The Bus Power Supply is not powered on.
- OR -
• The pluggable connector is disconnected from the Bus Power Supply.
1 Prepare the cable for termination by stripping the outer sheath and
individual wires, and then wire into the pluggable terminal block.
2 Wire the keypads as shown below.
Figure 1. Keypad wiring
Tip: If you are using a Control4 push-on (screwless) faceplate in a multi-gang installation, attach the black faceplate subplate to all of the devices that will be installed into the wallbox before attaching the devices to the wallbox. This will help ensure that all devices are properly aligned and on the same plane after installation.
3 Fit the wires back into the wallbox.
4 Align the keypad to the wallbox (the model number label should be at the
bottom), then fasten it with the included screws.
Important: Tighten the screws until the back side of the yoke plate is even with the wall surface, but no further. Overtightening can warp the keypad and cause it to malfunction.
5 Install the top actuator bar, bottom sensor bar, and buttons following the
instructions in the Keypad Buttons Installation Guide (
6 Install the Control4 faceplate following the instructions in the Faceplate
Installation Guide or attach a standard Decora-style or square faceplate.
7 Ensure that the Bus Power Supply is installed correctly and powered on. For
instructions, see the Bus Power Supply, 48V Installation Guide (
ctrl4.co/bps48
).
ctrl4.co/butn
).
Wiring diagrams
For bus wiring details, refer to the Keypad Bus Wiring Guide (
ctrl4.co/buswiring
).
Operation and configuration
On initial power up, all status LEDs on the keypad will illuminate green, indicating that the device has power. Until the keypad has been configured into a Control4 system, it will not control any loads. To set up this keypad for use with a Control4 system, refer to the Composer Pro User Guide (
ctrl4.co/cpro-ug
).
Button tap sequences
The button tap sequences are defined in the table below. Button tap sequences that require a single button should use the top-most button installed on the keypad. Button tap sequences requiring two buttons should use the top-most and bottom-most (or bottom-left) buttons installed on the keypad.
Function Button sequence
Identify 4
Reboot 15
Factory Reset 9-4-9
Unidentify 13-4-13
Troubleshooting
If the LEDs do not light up indicating that the keypad is receiving power:
• Ensure that the Bus Power Supply is powered on.
• Ensure that the Bus Ethernet Gateway is powered on and connected.
• Check for proper wiring (see “Installation instructions” above).
• For help on the installation or operation of this product, email or call the Control4 Technical Support Center. Provide your exact model number. Contact support@control4.com or see
www.control4.com
.
Care and cleaning
• Do not paint the keypad or its wall plate.
• Do not use any chemical cleaners to clean the keypad.
• Clean surface of the keypad with a soft damp cloth as needed.
Regulatory/Safety information
To review regulatory information for your particular Control4 products, see the information located on the Control4 website at:
www.control4.com/regulatory/
Patent information
Applicable patents are available at
www.control4.com/legal/patents
.
Warranty
For complete warranty information, including details on consumer legal rights as well as warranty exclusions, review the Warranty card or visit
www.control4.com/warranty
.
About this document
Part Number: 200-00346-C 10/26/2014 MS
.
More help
For the latest version of this guide and to view additional materials, open the URL below or scan the QR code. Your device must be able to view PDFs.
MOST RECENT VERSION
ctrl4.co/dec-wrd-ig
BUS WIRING GUIDE
ctrl4.co/buswiring
control4.com | 888.400.4070
©2014 Control4. All rights reserved. Control4, the Control4 logo, the Control4 iQ logo and the
Control4 certified logo are registered trademarks or trademarks of Control4 Corporation in
the United States and/or other countries. All other names and brands may be claimed as the
property of their respective owners.
Loading...