Winix D480, D360 User Manual

AIR PURIFIER
D480 / D360Model
User Manual
Use & Care Guide
• ThisproductismanufacturedforuseonlyintheUSAandCanada.
• Thisproductissuitablefor120Vonly.
2 3 4 5 6
MODEL PART DIAGRAM
FRONT
Control Panel
Front Panel
WHERE TO USE
4 in
12~18 in
BACK
Air Outlet Vent
Handle
Power plug
Allow 12 ~ 18 in. of space between TVs, radios, and other electronics
Electromagnetic interference from certain electronics may cause product malfunction.
Place indoors away from direct sun light
Direct exposure may cause product malfunction or failure.
Only place on hard, flat surfaces
Flimsy or slanted surfaces may result in abnormal noise and vibrations.
Allow at least 4 in. from walls
For maximum air flow.
CONTROL PANEL
02 04 100706
01 05 08 12
03
01. Smart Sensor
When in Auto Mode, the Smart Sensor detects the amount of impurities in the environment to adjust fan speeds.
02. Check Filter Indicator
LED light indicates when it is time to change the filter.
03. Filter Reset Button
After replacing the True HEPA Filter, use a small object such as a paper clip, to press and hold the reset button for at least 5 seconds until the Check Filter light turns off.
04. Auto Mode
The LED "Auto" light will indicate when Auto mode is activated.
•When in Auto Mode the Fan Speed is automatically adjusted according to the indoor air quality. As the indoor air quality improves, the fan speed will automatically decrease. If the indoor air quality worsens, the fan speed will automatically increase.
05. Auto Button
•Use the Auto Button to set the Air Purifier to Auto Mode.
06. Air Quality Indicator
Color-coded LED indicates one of three levels of air quality.
•BLUE (good), AMBER (fair), RED (poor).
07. Fan Speeds
Indicates the current fan speed.
08. Sleep Mode
The LED "Sleep" light will indicate when Sleep mode is activated. When Sleep mode is activated:
•The Air Quality Indicator LED light is disabled.
•The fan speed is automatically set to quiet.
09. Fan Speed Button
Use the Fan Speed Button to set the desired Fan Speed. Fan Speeds cycle in this sequence : Low, Medium, High, Turbo, Sleep, Low.
1109
10. Power Indicator
LED light indicates when the air-purifier is turned on.
11. Power Button
Turns the unit on or off. During the first 30 seconds of power, the Air Quality Indicator will cycle through Blue, Amber and Red colors.
•Smart Sensor takes approximately 4 minutes to gauge the air quality in the environment before normal operation begins.
3-STAGE AIR PURIFICATION
12. Light Sensor
When in Auto Mode, the light sensor detects when to put the unit into sleep mode.
•Detects the amount of ambient light in the environment.
1
01. Pre-Filter
Designed to catch larger airborne particles found indoors.
02. Activated Carbon Filter Sheet
Reduces VOCs and household odors from cooking, pets, and smoke.
2
Activated Carbon Filter SheetPre-Filter
03. True HEPA Filter
Captures 99.97%* of airborne allergens including; pollen, Mold spores, dust, pet dander, microbes, and smoke. *particles as small as 0.3 microns in size.
3
True HEPA Filter
INITIAL OPERATION
Latch
1.
Remove the front panel by grasping its upper edge and gently pulling forward.
3.
Remove the filters from the protective plastic bag.
2.
Remove the Pre-Filter, then the bag of filters behind it.
02
01
03
4.
Install the filters until they fit securely in place.
01. Pre-Filter (front)
02. Activated Carbon Filter Sheet (middle)
03. True HEPA Filter (back)
Latch
5.
After filters are installed close the front panel.
6.
Insert the power cord into an electrical outlet.
MAINTENANCE
When to Replace Filters
Filter Indicator Light When to service When to replace
Pre-Filter
Activated Carbon Filter Sheet
True HEPA Filter
•When the Check Filter indicator LED is on, it is time to replace the True HEPA Filter.
•Intervals between filter replacement may vary depending on environment.
none Clean once every 14 days Permanent
none
Can NOT be WASHED
Replace every 3 months
Lasts Approx.
12 months
D3
D4
•
Contact Winix for product related inquiries and customer service
Toexpediteservice,pleasespecifythemodelnameandnumber,thenatureoftheproblem,yourcontact information,andyouraddress.
Dedicated Call Center :
•
Website : www.winixamerica.com
(877) 699-4649
2610-0236-00 Rev.00
2 3 4 5 6
11 10 9 8 7
D3
D4
UNIT SPECIFICATIONS
Model Name
Power Voltage
Power Rate
Verified Room Size
Product Dimensions
Product Weight
Replacement Filter
The exterior, design, and product specifications may be changed without prior notice to improve product performance.
Warning : Change or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
Note : This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, it may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures.
•Reorient or relocate the receiving antenna.
•Increase the separation between the equipment and receiver.
•Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
•Consult the dealer or on experienced radio/TV technician for help.
This device contains license-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada's license-exempt RSS(s). Operation is subject to the following two conditions:
•This device may not cause interference.
•This device must accept any interference, including interference that may cause undesired operation of the device.
16.77 in(W) x 11.81 in(D) x 22.83 in(H) 14.96 in(W) x 10.33 in(D) x 21.06 in(H)
Filter D4 / SKU : 1712-0100-00 Filter D3 / SKU : 1712-0101-00
D480 D360
AC120V/60Hz
90 W 65 W
480 sq.ft. 360 sq.ft.
17.6 lbs 16.6 lbs
Loading...