WINIX AIR CLEANE
User Manual
Model
Use & Care
Guide
C535
• Please read and follow all safety rules and instructions
in this manual before operating.
• The product warranty is printed on the back of this
guide, so please keep it in a safe place for future use.
• This product is manufactured for use only in USA/CA
3-STAGE AIR PURIFICATION
Odor
Sensor
Power cord with plug
(This product is suitable
for 120V only.)
Air Outlet Vent
PlasmaWave
Light Sensor
Control Panel / Display Panel
®
True HEPA Filter
Carbon Filter
Sheet
Pre-Filter
Front Panel
Unit Pre-Filter / (4) Carbon Filter
English
Sheets /
(1) True HEPA Filter
Remote
Control
PACKAGE
CONTENTS
User
Manual
C535
2
CONTROLS
PlasmaWave® Indicator
Indicates whether PlasmaWave®
is enabled or disabled.
Mode Button
Press to cycle through
and set the desired
mode of operation
(Auto, Sleep).
Air Quality
Indicator
Color-coded LED
indicates one of
three levels of air
quality.
Fan Speed Button
Enables Manual operation of the
unit. Press to cycle through and
set the desired fan speed (Low,
Medium, High, Turbo).
Timer Indicator
If timer has been set, the
LED light indicates the set
time of operation.
Fan Speed
Indicator
Indicates the
current fan speed.
PlasmaWave® Button
Enables or disables
PlasmaWave®.
Power Button
Turns the unit on
or off.
Reset Button
After replacing a lter,
press the RESET button
for at least 5 seconds.
Odor Sensor
When in Auto
Mode, detects the
amount of odor in
the environment
to adjust fan
speeds.
Light
Timer
Button
Press to cycle
through and set
desired length of
operation (1hr,
4hr, 8hr).
Sensor
Detects the
amount of
ambient
light in the
environment.
Check Filter Indicator
LED light indicates when it is
time to change the lter.
WHERE TO USE
Allow 12 ~ 18 in. of space between TVs, radios, and other electronics
electromagnetic interference from certain electronics may cause product malfunction.
Place indoors away
from direct sun light
direct exposure may cause
product malfunction or failure.
Only place on hard, at surfaces
imsy or slanted surfaces may result
in abnormal noise and vibrations.
Allow at least 4 in. from walls
for maximum air ow.
English
C535
3
SAFETY AND CAUTIONS
Follow these instructions to reduce the
WARNING
Before operating this equipment, carefully read and follow these
safety cautions
Ensure lters are inserted before running unit
running unit without lters can shorten the units life and cause electric shock or injury.
Be sure foreign objects are NOT inserted into the vents on the unit
objects can include pins, rods, and coins.
Do not touch any part of the interior of the unit with wet hands
the high voltage may cause electric shock.
Ensure unit intake and outlet vents do not become blocked
blockage may lead to increased internal temperatures causing product failure and
deformation.
Do not use the unit as a step stool or place heavy objects on it
personal injury may occur or product failure and deformation.
risk of serious injury or death and to
reduce risk of damagin the unit.
Do not pull on the power cord
when unplugging the unit
If the unit becomes submerged in water,
unplug it and contact customer service
Do not plug additional appliances
into the same outlet or power supply
Unplug unit when not in operation
for extended periods of time
Do not use around mist or fumes from
industrial oil or around large quantities
of metallic dust
Do not install in any sort of motor or
transport vehicle (trucks, boats, ships,
etc.)
Do not place near any ammable
materials (aerosols, fuel, gases etc.)
Do not place below any electrical outlet
*This unit is not intended to be used to preserve documents or in art conservation.
English
Do not tie or knot power cord
when unit is in operation
Cord can become damaged by
forcefully bending, pulling, twisting,
bundling, pinching or placing heavy
objects on it
Do not unplug or move
the unit while in operation
Do not touch the plug with wet hands
Do not place in excessively humid
areas where unit may become wet
Do not place in an area with
excessive amounts of noxious gases
Do not have unit facing
into wind or draft
Do not place around heating elements
C535
4
INSTALLING FILTERS
This product comes with all the required lters. The protective
plastic wrap must be removed from the lters before use.
• Operating the unit without removing the plastic wrap may result in
product failure.
• Unplug and make sure the unit is turned off before installing lters.
Remove the front panel by
grasping its upper edge and
gently pulling forward.
Latch
Remove the lters from the unit.
They are protected inside a
plastic wrap.
Remove lters from
protective plastic wrap.
Operating the unit without
removing lters from plastic
wrap may cause abnormal noise,
deformation, or re as a result of
overheating.
Install the lters until
they t securely in place.
Filters must be installed
in this order:
3. True HEPA Filter (back)
2. Carbon Filter Sheet (middle)
1. Pre-Filter (front)
To install the Pre-Filter, insert bottom tabs into the slots on
either side of the lower part of the unit, then rotate upward to
Note
English
insert the upper tabs into the slots at the top part of the unit
until sides audibly click into place.
True HEPA
3
Filter
Carbon
2
Filter
Pre-Filter
1
C535
5