Winix AW600 User Manual

Page 1
Triple Action Humidier
Model: AW600
Thank you for purchasing this WINIX product
•Read and follow all safety rules and instructions before operating this equipment.
•Please keep this manual for future reference.
Page 2
Triple Action Humidier with
HumidiPür™ Model: AW600
PlasmaWave® technology removes air
pollutants resulting in cleaner fresher air.
Auto Mode
WINIX’s sensor detecs room humidity
level to control fan speed and optimize the humidity level.
Timer
The automatic Timer indicator is used
to maintain efciency throughout the
lifetime of the product.
Sleep Mode
Light sensor detects when the room is dark and adjusts the unit to Sleep Mode to reduce power consumption.
Winix HumidiPür™ Triple Action Humidier simultaneously humidies and cleans the air. Featuring a 3.17 gallon per day humidication capacity and 3-Stage air purication with PlasmaWave® Technology.
®
Mist Humidier
HumidiPür™ generates very ne and light mist to enhance consistent humidity level.
CleanCel® Anti-Bacterial Coating
HumidiPür™ has been treated with CleanCel®
antibacterial coating to prevent growth of
bacteria in the water tank and cleaning discs.
Auto Shut-Off
Automatically shuts off when the water bucket is Low.
Page 3
Table of Contents
Safety Instructions
Warning
Product Information
Unit Diagram Control Panel/Display
Installation
Selecting a Location Set-Up Instructions
Operation
Modes of Operations Care and Maintenance
Troubleshooting
FAQ/Solutions
Product Specications
3
11 12
13 14
15 19
25 27
Page 4
Safety Instructions
Warning
Follow these instructions to avoid any risk of personal injury, property damage,
electrical shocks or re hazard.
Notice
Failure to follow the safety instructions can lead to personal injury or property damage.
Warning
DON’T unplug the unit by pulling on it’s power cord.
PROHIBITED
DO NOT DISASSEMBLE
MUST FOLLOW
Ground connection protecting from electrical shock
DON’T touch the plug with wet hands.
DON’T bend or place heavy object on the power cord.
DON’T replace or modify power cord.
If the power cord/plug is damaged, it must be replaced by the manufacturer or a
qualied technician.
Page 5
Warning
DON’T plug multiple power plugs into an outlet. Plug directly into the wall.
DO unplug the HumidiPür™ when not in use to save on energy consumption.
DON’T attempt to repair, alter or dissasemble the unit.
DO connect the power cord to only proper power outlet with a ground connection.
DON’T plug power cord into loose or damaged electrical outlet. (This can lead to overheating or electrical shock)
DON’T operate the unit if standing water is present.
Page 6
Safety Instructions
Note
Note
DON’T operate HumidiPür™ on an uneven surface.
DON’T place the HumidiPür™ near
ammable material (such as gas,
aerosols, or benzene).
Attempt to change the bucket and
rell with clean water every day.
DON’T spray liquids directly into air washer.
DON’T place the unit on an unstable place such as a table or a sink.
DON’T pour water into the top of the air unit, place in water tank as directed.
Page 7
Note
DO unplug the unit and contact your service dealer if the unit comes in contact with water.
DON’T remove the water tank if a child is nearby.
DO unplug the unit and contact your service dealer if it is sunken under water.
DON’T insert ANYTHING into the air inlet or outlet.
DON’T install the unit in the place full of high humidity or dust.
DON’T place anything around the unit to allow children to play or sit on.
Page 8
Safety Instructions
Note
DON’T disconnect the power cord during operation.
DO use the HumidiPür™ after assembling the Antimicrobial Disk.
DON’T place hands or any body parts near the air outlet during operation.
DO unplug the appliance
during lling and cleaning.
DON’T insert anything into the air inlet or outlet.
DON’T place the unit near curtains or other materials that can block the vents of the unit.
DO unplug the unit and contact your service dealer if any irregular noise or smoke occurs.
DON’T place the unit near a heat source.
DON’T strike or drop the unit.
Page 9
Note
DON’T allow children to
play
play on or near the unit.
DON’T spray ammable
liquids or gases into the unit.
DON’T install the unit under direct light.
DON’T use hot water in the water tank.
DON’T lift the unit by the top.
DON’T place clothes and towels on top of air washer while operating.
DO clean Antibacterial disk regularly with warm tap water and allow to air dry.
DON’T use ammable
material (such as benzene or alcohol) to clean the unit.
DON’T spray liquids directly into HumidiPür™ during cleaning.
Page 10
Safety Instructions
Note
DON’T install the unit near the wall or window.
DON’T operate the unit while insecticide is used.
DON’T install the unit
whose airow outlet is
facing the wall.
DON’T put the unit near burning cigarette or incense.
DON’T allow water to stay in the water tank for a long time while not in use.
DON’T drink the water left in the water tank or give it to plants or animals.
After cleaning, allow Antibacterial Discs,
water tank, and pre-lter
to air dry completely.
DON’T operate the unit while water tank is damaged.
DON’T put the unit near a microwave oven or TV.
Page 11
Note
DON’T overll the water
tank.
DO dispose of the water to prevent it from freezing in cold weather.
DO unplug the unit and move its water tank when water is removed.
DON’T put the unit near ceilings, walls, furniture, or electronic appliances.
DON’T lift the unit with water still in the water tank.
DO clean the air washer
regulary, with a microber
towel or any other clean wiping material.
DON’T plug in if the power plug is touched with water.
DON’T put magnet or metal material on the top of the unit.
DO use clean tap water without detergent, soap, chemical compounds or hot water (over 104ºF).
10
Page 12
Product Diagram
Front Panel
Anti-bacterial Disc (CleanCel®)
Anti-bacterial Disc Handle
Water Level Indicator
Anti-bacterial Water Tank (CleanCel®)
Water Tank Release Lever
Control Panel Display Air Outlet Cover
Air Outlet
11
Fan (inside) Air Outlet Release Button
HEPA + Carbon Comination Filter
Air Intake
Power Plug
Page 13
Control Panel
Function Button
1. Continuous Mode Unit operates continuously on the fan speed selected by user (Low/Mid/High) regardless of ambient humidity.
2. Sleep Mode Dims control panel lights and sets the unit to operate at lowest fan speed.
3. Auto-Mode
Unit runs until ideal humidity level is reached and shuts off intermittently to save energy (Green “Comfort Zone”).
Low Water
Power
Mode
Indicator
Indicator
PlasmaWave
(ON/OFF Indicator)
Timer
Setting Button
®
Indicator
Timer
Fan Speed
Indicator
Fan Speed Button
(Low, Medium, High)
Low Humidity Indicator
High Humidity Indicator
PlasmaWave
(ON/OFF Button)
Control Panel
Lock Indicator
®
PlasmaWave
(ON/OFF Indicator)
Humidity Level Indicator
Displays humidity level, when desirable level of humidity levels are reached they will be displayed in the green “Comfort Zone”
Orange -> Low Humidity (Below 30% RH) Blue -> High Humidity (61-70% RH)
Green -> Ideal Humidity (40-60% RH)
®
12
Page 14
Installation
Selecting a Location
15 inches
15 inches
Do not install the unit under direct sunlight.
- Long Exposure to direct sunlight can cause defects.
HumidiPür™ must be installed and operated on an even surface.
- Vibrations and noise can occur on soft or non-at surfaces.
4 inches
4 inches
13
Product must be Installed approximately 10cm/ 4 inches away from the wall and 30-40cm/ 15 inches from other electronic appliances.
Before operating the HumidiPür™, remove any plastic bags and polyfoams from
outside and inside the unit.
Page 15
Operation
Set-Up Instructions
1. Slide water tank out, by using the release
lever located below the water tank on
the front of the unit.
2. Fill the water tank with cool tap water up to the indicator line on the inside of water tank.
3. Replace the water tank by sliding it back into the unit until you hear it click into place.
4. Gently slide down the front panel and
make sure that it is seated properly and lines up correctly.
Make sure to unplug the power cord before lling the unit with water.
We recommend using ltered water to prolong the life of the product.
Use cautions when moving the unit lled with water.
14
Page 16
Operation
Before Turning On
Plug the power cord into a power
1
outlet.
Push the POWER button.
2
15
The unit will start on AUTO
3
MODE and the PlasmaWave®
function will be ON.
A soft buzzing or clicking sound may occur during operation; if this is uncomfortable, you can turn off the PlasmaWave feature by using the PlasmaWave® ON/OFF button.
®
Page 17
Auto Mode
Push FUNCTION button to select
1
Auto Mode
AIR FLOW: When ambient humidity is sensed at less
that 60%, the unit will operate at “High”
fan speed. When the ambient humidity is sensed at greater than 60% the unit
will operate at “Low” fan speed.
CLEANING DISCS:
When ambient humidity is sensed at greater than 75% humidity the cleaning discs will stop spinning. When ambient humidity is sensed less than 60%, the disc, resumes to circulate.
Continuous Mode
Push the FUNCTION button to select
1
Continuous Mode.
- Continuous Mode Indicator will illuminate.
- The FUNCTION button will cycle the unit between the following: Auto -> Continuous -> Sleep
16
Page 18
Operation
Sleep Mode
Push the FUNCTION button to select
1
Sleep Mode.
The MODE button will cycle the unit between the following:
Auto -> Continuous -> Sleep
During Sleep Mode the unit will set fan
2
speed to lowest setting and the display will turn off, except for the low fan speed indicator.
Adjust Fan Speed
Push the FAN SPEED button to change the Fan Speed.
17
The FAN SPEED button will cycle the unit between the following:
Low -> Med -> High
Page 19
Adjust Timer
Push TIMER button to set a timer.
The TIMER button will cycle through the unit timer settings:
2 hours -> 4 hours -> 8 hours
PlasmaWave® Technology
During Humidication process
During Humidification process
Push PLASMAWAVE/LOCK button to
operate PlasmaWave®.
Use this button to turn PlasmaWave
function ON/OFF
During PlasmaWave® operation only
During PlasmaWave® operation only
Push PLASMAWAVE/LOCK button to
operate PlasmaWave® while the unit OFF.
Use this button to turn PlasmaWave
function ON/OFF without using the
humidication function of the unit.
®
®
Lock Button
Push PLASMAWAVE/LOCK button for
more than 3 seconds to activate Lock.
18
Page 20
Care & Maintenance
Emptying the Water Tank
Use the tab on the bottom of the
1 2
water tank and gently slide it out to open.
Remove the used water left in the water tank and dispose of it in an
3
appropriate manner. Rell water tank with clean water.
Replace the water tank with a
4
snap.
Lift disc assembly by the antibacterial handle and
carefully remove it.
Gently slide down the front
5
panel to close.
19
Be sure to change water frequently to ensure optimal functioning of the unit.
Be sure to replace the water tank correctly in order to ensure that the unit functions properly.
Page 21
Cleaning Surface
Clean the outside of the unit with a soft cloth and mild detergent. Wipe clean with a dry cloth.
Cleaning Rear Air Intake Grille
Use the tab on the back cover grille
and pull up on the Combo Filter.
After cleaning, and letting air dry, slide the HEPA + Carbon Filter back into
it’s original location and replace the back cover grille.
Unplug the HumidiPür™ before performing any type of maintenance such as cleaning or disassembling.
Do NOT clean the top portion of the unit with water. Empty and unplug if not operating for more than 2 days.
To clean the back cover grille rinse
lightly under warm water and air dry.
20
Page 22
Care & Maintenance
Cleaning Anti-bacterial Discs
Be sure to clean the Anti-bacterial Discs once a week
Clean Anti-bacterial Discs with warm tap water and a light detergent.
Fill warm tap water with detergent
1
in the water tank.
21
Clean inside of the cycled
2
Anti-bacterial Discs thoroughly.
CleanCel® Anti-bacterial Cleaning Discs are dish washer safe and can be washed in temperatures no greater than 176OF
Page 23
Turn Gear of the Antibacterial Disc
1
counterclockwise, and pull the front of the Disc out, and separate axis from
the rear Gear Disc, by turning it
counterclockwise.
Rinse Antibacterial Disc with warm
2
tap water and a mild detergent.
Clean the inside of water tank with
3
a soft cloth and mild detergent.
Gear Disc
Disc Plate
Axis
(inside)
Disc
Saw Tooth Gear Disc
Disc Plate
After cleaning, assemble the parts
4
(Gear Disc, Discs, and Saw Tooth Gear
Disc) in the opposite order.
22
Page 24
Care & Maintenance
Cleaning Water Tank
Clean the inside of the water tank
1
with a soft cloth and mild detergent.
Place CleanCel® Anti-bacterial Discs
2
back into the water tank aligning with grooces and with handle laid
at.
Replace the Water Tank with a snap.
3
23
Gently slide down the front panel to
4
close the unit. Make sure that it is seated properly and lines up correctly.
Page 25
Cleaning Inner Parts and Fan
Turn groove to open with a coin or at
1
tip screw driver, at the rear of the unit, and remove top cover.
Holding fan, turn fan cap clockwise.
2
3
Rinse fan and fan cap with warm tap water with detergent.
Remove dust near airow inlet of the
4
unit by using vacuum cleaner or soft
brush.
After cleaning, replace fan and fan
5
cap.
24
Page 26
Care & Maintenance
Symptom
HumidiPür™ does
not turn on
Auto Mode is not
working
Vibrates or makes
noise
Check If: Solution:
Power cord is plugged in.
Low Water Indicator light is on.
Water is lled inside
water tank.
Power cord is plugged in.
Auto Mode Indicator is on.
The unit is located on
an uneven surface.
Plug the power cord in.
Fill the water tank
Make sure the water tank is in place and
lled correctly.
Unplug power cord and plug it back in.
Push FUNCTION button to select Auto Mode.
Move to an even
surface.
25
Power cord is hot
Power cord is plugged in.
Unplug the power cord and contact customer support.
Page 27
Symptom
Check If: Solution:
HumidiPür™ does
not turn on
Function button
is not working
Unpleasant odors
are present
Water is ground water.
¢ ¢
¢ ¢
Water is too cold or icy.
Fan speed is on low
level.
Child-Lock mode is on.
HumidiPür™ is being used where strong odors and/or dust is present
Change to tap water.
Use 68˚F to 77˚F
temperature water.
Change to high fan speed.
Push Plasma/Child Lock button for 3 seconds to turn OFF Child-Lock
mode.
Replace the water in the water tank and change water more frequently.
Clean water tank and CleanCel
®
Anti-bacterial Discs.
Water level indicator
is on despite water level
Water is left inside the water tank.
Rell the water tank.
26
Page 28
Specications
Model No.
Power Supply
Power
Consumption
Humdiifying
Capacity
Tank (Max/Full)
Weight
Dimensions
-
AW600
120V / 60 Hz
16W
3.17 gallons per day
1.3 gallons / 1.85 gallons
15.4 lbs.
13.4” x 17.7” x 13.4”
27
Page 29
Notes
Page 30
This marking shown on the product or its literature. Indicates that it should not be disposed with other household wastes at the end of its
working life. To prevent possible harm to the environment or human
health from uncontrolled waste disposal. Please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources.
Household users should contact either the retailer where they
purchased this product, or their local government ofce, for details of where and how they take this item for environmentally safe recycling.
Business users should contact their supplier and check the terms and conditions of the purchase contract. This product should not be mixed with other commercial wastes for disposal.
www.winix.com
Loading...