Winix AW107 User Manual

Page 1
WINIX Korea 35-1, Unjung-Dong, Bundang-gu, Seongnam-si, 463-440, South Korea
www.winixcorp.com e-Mail sales@winixinc.com Tel +82.31.701.1173(4574)
WINIX Inc 120 Prairie Lake Road, Unit E East Dundee, lllinois 60118
www.winixinc.com e-Mail info@winixinc.com Tel +1.847.551.9900
WINIX Europe 14 Cours de l'Intendance, 33000 Bordeaux, France
www.winixeu.com e-Mail info@winixeu.com Tel +33.556.448.572
Thank you for purchasing this WINIX product
Household users should contact either the retailer where they purchased this product, or their local government office, for details of where and how they can take this item for environmentally safe recycling.
Business users should contact their supplier and check the terms and conditions of the purchase contract. This product should not be mixed with other commercial wastes for disposal.
Sep. 2012
To buy: Contact Sylvane at 800-934-9194 or visit www.sylvane.com For product support: Contact Winix at 877.699.4649
Page 2
1 2
Introduction
Installation
Operation
Maintenance
TABLE OF CONTENTS
FEATURES 1 Read all instruction 1 INTRODUCTION 3
SAFETY INSTRUCTIONS 3 PRODUCT AND PARTS VIEWS 7
PRODUCT INSTALLATION 9
SETTING UP YOUR AIR WASHER 9
PRODUCT OPERATION 10
BEFORE TURNING ON 10 AUTO MODE 12 SLEEP MODE 13 ADJUSTING FAN SPEED 13 EMPTYING WATER TANK 14
CARE AND MAINTENANCE 15
OUTER SURFACE 15 CLEANING PRE-FILTER 15 CLEANING ANTIMICROBIAL DISK AND WATER BUCKET 16 CLEANING THE UNIT 17 FAQs & TROUBLESHOOTING 19
SPECIFICATIONS 21
FEATURES
2-in-1 Air Treatment
The Winix FresHome Air Washer gently and safely captures odors and impurities while gently humidifying the air.
Cleancel
TM
Anti-Microbial Coating
The Winix Air Washer is treated with CleancelTMto prevent the growth of odor causing bacteria and microbes on the cleanable humidifying collection discs.
Auto Sleep Mode
The Winix Air Washer will automatically dim the display lights and operate at lowest speed to not disturb sleep.
Auto Mode
A sensor continually monitors the environment and adjusts the performance for optimal humidity levels.
Auto Shut-Off
WINIX Air Washer shuts off automatically when the water bucket is low.
Plasma Wave
TM
Technology
Attacks pollutants at the molecular level to neutralize viruses, bacteria, chemical vapors, odors and gases in the air leaving the Air Washer.
Read all instruction: Important Safeguards
When using electrical appliances, especially when children are present basic safety precautions should always have followed, including the following:
1. Always have water in the water tank when operating unit.
2. Use only clean, cool tap water to fill tank.
3. Use only 100~120V AC outlet. As with any electrical device, plug and unplug unit with dry hands only. Turn unit off prior to unplugging it. Unplug unit when not in use and before you clean or move the unit.
4. This unit shuts off automatically when water tank is empty.
5. Never operate unit with a damaged coed or plug. Keep cord straight.
6. Always place unit on an elevated (at least one(1)foot off the ground), flat, level surface away from direct sunlight. Keep cord away from heated surface and areas where it could be walked on or tripped over. Do not place on objects that are not resistant to water damage from spillage or moisture.
7. Do not titt or tip unit or attempt to empty or fill it while it is operating.
8. The unit should not be left unattended in closed rooms as air could become saturated and leave condensation on walls or furniture. Always leave room door partially open.
9. Do not tilt or tip unit or attempt to empty or fill while it is operating.
10. Replace demineralization cartridge every 2~3 months or more frequently as needed.
Page 3
Power Cord
Warning
43
INTRODUCTION
DON'T unplug the unit by pulling on its
power cord.
DON'T touch the plug with wet hands.
DON'T bend or place heavy object(s) on
the power cord.
DON'T replace or modify the power cord.
If the power cord/plug is damaged, it must be replaced by the manufacturer or a qualified technician.
Follow these instructions to avoid any risk of personal injury, property damage, electrical shocks or fire hazards.
WARNING
Failure to follow the safety instructions can lead to personal injury or property damage.
NOTICE
WARNING / NOTICE DIRECTION
PROHIBITED
DO NOT DISASSEMBLE
Introduction
WARNING:SAFETY INSTRUCTIONS
Warning
Power
Warning
Operation
DO connect the power cord to outlets with a ground connection ONLY.
DO unplug air washer when not in use to save energy consumption.
DON'T
plug power cord into loose or damaged electrical outlet.
(Can lead to overheating or electrical shock.)
DO NOT
attempt to repair, alter or disassemble the air washer.
DON'T
operate the air washer if standing water is present.
DON'T
operate air washer
on an uneven surface.
DON'T pour water into the top of the air washer, only place in water tank as directed.
DON'T operate air washer near flammable materials.
Must Follow
Ground connection protecting from electrical shock
Page 4
Note
Operation
65
Note
Power
Note
Operation
DON'T disconnect the power cord during operation.
DO unplug the appliance during filling and cleaning.
DO unplug the unit and contact your service dealer if any irregular noise or smoke occurs.
DO use the air washer after assembling the Antimicrobial Disk.
DON'T insert ANYTHING into the air inlet or outlet.
DON'T place the air washer near a heat source.
DON'T place hands or body parts near the air outlet during operation.
DON'T place the air washer near curtains or other materials that can cover the vents of the unit.
DON'T strike or drop the air washer.
DON'T allow children to play on or near the air washer.
DON'T use hot water in the water tank.
DO clean Antimicrobial disk regularly with warm tap water and allow to air dry.
Discs are top-rack dishwasher safe. Follow directions in the Care and Maintenance section.
DON'T spray flammable liquids or gases into the unit.
DON'T place air washer near your head when you sleep.
DO move the top cover and water bucket of the unit separately when moving air washer.
DON'T
use flammable material (such as benzene or alcohol) to clean the air washer.
DON'T
cover the top of the air washer during operation.
This appliance intended for adult use only.
DO NOT
spray liquids directly into
air washer during cleaning.
DON'T install the unit in direct sunlight or near inverter lighting or automatic sensor lights.
Introduction
Page 5
87
Display Panel
Power / Function Button
Disk Assembly Handle
Air outlet
CleancelTMAntimicrobial Disks
Water Bucket
Power Cord
Air Inlet
Power Button
Current Humidity Level
Fan/Disk Speed
PlasmaWave
TM
On/Off Indicator Low Water Indicator
Function Button:
Fan/Disk Speed (LOW 󳥕MEDIUM
󳥕
HIGH), Sleep Mode, Auto Mode.
Front
Display Panel and Controls
Back
Introduction
PRODUCT AND PARTS VIEWS
Top Cover
Pre-Filter
Light Sensor
Sleep Mode Indicator
Auto Mode Indicator
Page 6
9 10
PRODUCT INSTALLATION PRODUCT OPERATION
Do not install the unit under direct sunlight.
󳢯
Long Exposure to direct sunlight can cause defects.
Air Washer must be installed and operated on an even surface.
󳢯
Vibrations and noise can occur on soft or non-flat surfaces.
Products must be installed approximately 4 inches away from the wall and 15 inches from other electronic appliances.
Before operating the air washer, remove any plastic bags and polyfoams from outside and inside of the unit.
SPACE SELECTION & INSTALLATION
For better performance and longer product life, please select an adequate space to install the unit.
Installation
Operation
Fill the water tank with cool tap water
up to the indicator line on inside of the water tank. For optimal performance do not overfill.
Replace the top section of the air cleaner.
Make sure that it is seated properly and lines up correctly.
Lift and remove top section of the
air washer to open.
Water Line
Cautions
Make sure to unplug the power cord before filling the water tank.
Hard water may cause operation defects. Please use filtered water if necessary.
Use caution when moving air washer with a full water tank, as it will be heavy.
SETTING UP YOUR AIR WASHER
BEFORE TURNING ON
Page 7
1211
Operation
Push POWER button.
Plug the power cord into a power outlet.
The air washer will start in Auto Mode
and the PlasmaWaveTMfunction will be ON. If the Low Water Indicator is on, refill the water bucket.
AUTO MODE
Push FUNCTION button to select Auto
mode.
󳢯
The FUNCTION button will cycle the unit between the following: LOW
󳥕 MEDIUM 󳥕 HIGH 󳥕
SLEEP MODE 󳥕 AUTO MODE.
AUTO Mode Indicator will illuminate.
󳢯
Fan and disk speed will automatically adjust, according to chart below, for optimal humidity level of around 50%.
Push the POWER button to turn off.
󳢯
All lights will be off.
Fan speedHumidity Range
More than 60% LOW
MEDIUM
HIGH
From 50% to 59%
Less than 50%
Page 8
1413
Manual Sleep Mode
Push FUNCTION button.Select Sleep Mode.
(Indicator light will illuminate)
Sleep Mode will dim the display lights.
(Fan speed :low)
Auto Sleep Mode
When in Auto Mode (see previous section), the light sensor will detect the light in the room and will turn on Sleep Mode when external light sources are dimmed.
Maintenance
SLEEP MODE EMPTYING WATER TANK
󳦊
Push FUNCTION button to change Fan/Disk speed.
󳢯
The FUNCTION button will cycle the unit between the following: LOW
󳥕 MEDIUM 󳥕 HIGH 󳥕
SLEEP MODE 󳥕 AUTO MODE
󳦊
Remove the use water left in the water
tank and dispose of in an appropriate manner. Refill water tank. (do not fill past indicator line as directed)
Replace the disk assembly. Lay handle
down flush with water tank. Carefully replace top section of air washer and assure proper alignment.
Remove the top cover the unit. Lifet the
disk assembly by the handle and carefully remove it.
Cautions
Allows unplug the power cord when removing or adding water to the water tank.
If the air washer has not been used for an extended period of time, use fresh water to avoid performance issues.
Adjust Fan/Disk Speed
Page 9
15 16
Maintenance
Clean the inside of water bucket with a
soft cloth and mild detergent.
󳢯
Clean the water bucket every week to prevent the growth of mold, germs, and bacteria.
󳢯
Refill the bucket with clean tap water.
Place CleancelTMAntimicrobial Disk back
into the bucket aligning with grooves and with handle laid flat.
Clean Antimicrobial Discs with warm
tap water.
Cautions
Before cleaning air washer, unplug the power cord.
Don’t use flammable materials such as benzene and alcohol to clean air washer.
If the air washer has not been used for more than two days, unplug the power cord and refill the water bucket with new water.
Always clean the antimicrobial discs and water bucket of the unit has not been used for an extended period of time to prevent contamination.
CARE AND MAINTENANCE
Rinse pre-filter clean with warm tap
water.
Use tabs and slide pre-filter back into
original position.
Use the tab on each side of the prefilter
and gently pull up and out from both sides.
Clean the outside of the unit with a soft cloth and mild detergent. Wipe clean with a dry cloth.
OUTER SURFACE CLEANING ANTIMICROBIAL DISK AND WATER BUCKET
CLEANING PRE-FILTER
Page 10
17 18
Maintenance
Wash the fan with warm water.
Use a soft cloth to wipe dry.
Reassemble in reverse order after
cleaning.
Gently clean the inside of the housing
with a soft cloth or vacuum cleaner attachment.
Cautions
Only the fan should be washed with water.
Open venting guides until you hear
them 'click'
Remove the fan cover by turning the
locking nut clockwise and lifting the fan up.
Remove the top cover and place it
upside down on an even surface.
󳦊
CLEANING THE UNIT
Page 11
2019
Symptom Check if: Remedy:
Water is too cold or icy.
Fan speed is on low level.
Use 68℉to 77
temperature water.
Change to high
fan speed.
Remove the film.Use FUNCTION button to
turn off Sleep Mode.
Low air flow.
Display panel light is too dark.
Protective film is still on.Manual Sleep Mode is on.Auto Sleep Mode is on.
Unpleasant odors are present.
Air Washer is being used
where strong odors and/or dust are present.
Replace the water in the
water tank and change water more frequently.
Maintenance
FAQs & T
roubleshooting
Check if you can resolve issues before calling customer service.
Symptom Check if: Remedy:
Power cord is plugged in.Low Water Indicator light
is on
Top and bottom sections
are aligned.
Plug the power cord in.Fill the the water tank.Make sure the top and
bottom of the air washer are lined up correctly.
Air washer does not turn on.
Power cord is plugged in.
Auto Mode Indicator is on.
Sensor is obstructed.
Plug the power cord in.Push FUNCTION button
to select Auto Mode.
Clean the sensor surface
Auto Mode is not working.
The unit is located on an
uneven surface.
Move to even surface.
Vibrates or makes a lot of noise.
Page 12
2221
NotesSPECIFICATIONS
Model No.
Power Supply
Power Consumption
Humidifying Capacity
For rooms up to
Tank(Max/Full)
Weight
Dimension(WXDXH)
230V / 50Hz
10
/ 8
330×330×420(mm)
400CC / Hour (20
/30%)
6.5
17W
AW107 (EU)
110V / 60Hz
2.64gal/2.11gal
600 sq. ft.600 sq. ft.
12.9In
×12.9In×16.5In
0.105gal / hour(33.8
/30%)
14.3Ib
17W
AW107 (USA)
Loading...