Winix Air Cleaner User Manual

TABLE OF CONTENTS
Warranty......................................................2
Package Contents......................................2
Safety Instructions...................................2-3
Product Specications................................3
Air Cleaner Features................................4- 5
Air Cleaner Set-Up.......................................5
Display Panel...........................................6-7
Operation....................................................8
Remote Control......................................9-10
Care and Maintenance........................11-12
Troubleshooting........................................13
WARRANTY
ONE YEAR LIMITED WARRANTY ON WINIX PLASMAWAVE™ AIR CLEANER If this air cleaner fails due to defects in material or workmanship within one year from the date of purchase, return it to place of purchase and you will receive a new one free of charge.
• This warranty does not include the air cleaner’s replaceable lter cassette; that is an expendable part that can wear out from normal use before one year expires.
• This warranty is void if this product is used for commercial or rental purposes.
• This warranty gives you specic legal rights, and you may also have other rights, which vary from state to state.
PACKAGE CONTENTS
• Winix PlasmaWave™ Air Cleaner
• Remote Control (1 unit)
• Batteries (2 AA batteries)
• Operator's Manual
SAFETY INSTRUCTIONS
Thank you for purchasing a Winix air cleaner. Please read this manual carefully before using. This product is for household use only.
IMPORTANT CAUTIONS FOR USING YOUR AIR CLEANER
WARNING:
manual to reduce the risk of electric shock, short circuit, and/or re:
• Do not repair or modify the unit unless specically recommended in this manual. All other repairs should be completed by a qualied technician.
• The plug for this unit is polarized with one blade wider than the other. Do not force the plug into an electrical outlet. Do
not alter the plug in any way. If the plug does not t into the outlet, reverse the plug. If it still does not t, contact a qualied technician to install a proper outlet.
• Do not use if the power cord or plug is damaged or the connection to the wall outlet is loose.
• Use AC 120V only.
• Do not damage, break, forcefully bend, pull, twist, bundle, coat, pinch, or place heavy objects on the power cord.
• Periodically remove dust from the power plug. This will reduce the chance that humidity will accumulate, which increases the risk of electric shock.
• If the power plug is damaged, it must be replaced by the manufacturer or a qualied technician.
2
• Remove the power plug from the outlet before cleaning the unit. When removing the power plug, grasp by holding the plug itself, never hold by the cord.
• Remove the power plug from the outlet when the unit is not in use.
• Do not handle the power plug with wet hands.
• Do not operate the unit when using indoor smoke-generating insecticides.
• Do not clean unit with benzene or paint thinner. Do not spray insecticides on the unit.
• Do not use the unit where it is humid or where the unit may get wet, such as in a bathroom.
• Do not insert ngers or foreign objects into the air intake or outlet.
• Do not use the unit near ammable gases. Do not use near cigarettes, incense, or other spark-creating items.
PRODUCT SPECIFICATIONS
• Unit will not remove carbon monoxide emitted from heating appliances or other sources.
IMPORTANT INSTRUCTIONS FOR USING YOUR AIR CLEANER
• Do not block the intake or outlet vents.
• Do not use near hot objects, such as a stove. Do not use where the unit may come into contact with steam.
• Do not use the unit on its side.
• Keep away from products that generate oily residue, such as a deep fryer.
• Do not use detergent to clean the unit.
• Do not operate without a lter.
• Do not wash and reuse the True HEPA Filter.
WAC-5000
Area Served 270 sq. ft. 180 sq. ft. 270 sq. ft.
CADR
Power Supply
Power Rate Low 6W, Turbo 70W Low 6W, Turbo 50W Low 6W, Turbo 70W Fan Speed 5 Speeds 5 Speeds 4 Speeds Control Type Auto/Manual Auto/Manual Auto/Manual Dust Sensor Yes Yes No Odor Sensor Yes Yes Yes Timer 2 and 4 hours 2 and 4 hours No Sleep Mode Yes Yes Yes
Filters 1 Replaceable Cassette 1 Replaceable Cassette
Cleaning System
HEPA Filter 99.97% 99.97% 99% Technology PlasmaWave™ PlasmaWave™ PlasmaWave™ Color Metallic Silver Metallic Silver Graphite Remote
Control Dimension 16.3”(W) X 8.5”(D) X 21.7”(H) 13.8”(W) X 8.1”(D) X 18.5”(H) 16.3”(W) X 8.5”(D) X 18.5”(H) Weight 17 lbs 13.2 lbs 13.0 lbs
184/175/197 (Dust/Smoke/Pollen)
AC 120V/60(Hz) AC 120V/60(Hz) AC 120V/60(Hz)
1. Washable Anti-Bacterial Pre-Filter
2. True HEPA Filter
3. Nano-Silver Mesh
4. Washable Carbon Filter
5. PlasmaWave™
Yes Yes No
WAC-5000S WAC-5000B
126/117/138 (Dust/Smoke/Pollen)
1. Washable Anti-Bacterial Pre-Filter
2. True HEPA Filter
3. Nano-Silver Mesh
4. Washable Carbon Filter
5. PlasmaWave™
184/175/197 (Dust/Smoke/Pollen)
1 Carbon Pre-Filter 1 HEPA Filter
1. Carbon Pre-Filter
2. HEPA Filter
3. PlasmaWave™
3
AIR CLEANER FEATURES
NOTE: The features of your air cleaner may vary according to model.
Ultra-Quiet Operation This Winix air cleaner has a multi­ speed fan with ultra-quiet operation that is ideal for nighttime operation.
Easy Maintenance
Winix air cleaners are simple and
economical to maintain. For optimum performance, replace complete lter cassette when REPLACE FILTER indicator light is on.
Smart Dust and Odor Sensors The 5000 air cleaner is equipped with digital sensors that automatically monitor air quality. As dust or odor levels change, fan speeds will adjust automatically. *5000B is equipped with only odor sensor.
Simple Operation Winix air cleaners have a remote control and user-friendly display for your convenience.
• Energy Savings When set on Energy Savings mode, fan
speed will not increase above level three. Winix air cleaners are Energy Star compliant.
FRONT SIDE
PlasmaWave
MULTI-STAGE CLEANING
Air undergoes ve (5000 & 5000S) or three (5000B) separate processes before returning, freshened and cleaned, to the room.
Washable Anti-Bacterial Pre-Filter
(5000 & 5000S)
This reusable lter collects large particles, pollen, pet hair, lint, etc.
Carbon Pre-Filter (5000B) Very effective Carbon lter sheet collects large particles, dust, pollen, pet hair, and lint as well as odors caused by cigarette smoke, organic decay, and cooking.
True HEPA Filter (5000 & 5000S) Captures 99.97% of particles and impurities as small as .3 microns including smoke, dust, pollen, mold spores, and pet dander.
HEPA-type Filter (5000B) Captures 99% of particles and impurities including smoke, dust, pollen, mold spores, and pet dander.
Nano-Silver Mesh (5000 & 5000S)
A shield of silver particles one billionth of a meter in size neutralizes bacteria
TM
on contact.
Power Plug
(Image shown here for 5000 and 5000S)
Display Panel
DC Motor
Washable Nano-Silver Mesh/Carbon Filter
Cassette Frame
True HEPA Filter
Pre-Filter
4
Front Panel
TOP SIDE
Air Outlet
Remote
Control
Cradle
Washable Carbon Filter
(5000 & 5000S)
Activated granular carbon effectively collects chemical vapors and odors caused by cigarette smoke, organic decay, and cooking.
AIR CLEANER SET-UP
PlasmaWave™ (All) In the nal stage of cleaning, Winix PlasmaWave
TM
technology generates both positive and negative ions to create plasma clusters which instantly neutralize viruses, bacteria, chemical vapors and odors in the air.
NOTE: Follow these instructions for best results.
• Place unit at least 7 feet from equipment that emits electric waves such as televisions or radios.
• Place unit at least 2 feet from the wall.
• Keep sensors away from drafty areas.
• Keep curtains away from sensors, as they may interfere with air intake/outlet.
• Place unit on a stable surface with plenty of air circulation.
1. Remove protective lm from the control panel.
2. Remove the front panel by grasping the bottom outside edges and gently pulling toward you.
3. Pull out the lter cassette by grasping the tabs located on each side of the lter cassette. (There are no tabs on 5000B HEPA lter.)
5. Return the lter cassette into the main unit.
6. Replace the front panel by hooking the front panel on the top of the unit. Swing panel in by pushing gently until the panel snaps into place.
7. Plug in the power cord to a wall outlet.
8. Press POWER button until short “beep” is heard.
For the rst 4 minutes after turning the unit on, the dust and odor indicators will ash while the unit measures air quality.
4. Remove the plastic wrap from the lter cassette.
5
DISPLAY PANEL (5000 and 5000S)
2
1
3
1. DUST & ODOR SENSORS -
Automatically monitor air quality and adjust fan speed accordingly.
2. REPLACE FILTER INDICATOR - The indicator will signal when to replace the lter cassette.
3. TIMER - Indicates timer setting or continuous mode.
4. FAN SPEED INDICATOR - Shows current fan speed setting.
5
4
6
7
1
5. SLEEP MODE - The unit will work on
Ultra-Quiet mode and dim the control panel lights.
6. AUTO (NORMAL/ENERGY SAVE) - The unit is set to default to NORMAL (Automatic operation) when it is rst turned on. Smart sensors will automati­ cally sense the amount of impurities in the air, and adjust the fan speed accord­ ingly. When set on ENERGY SAVE mode, fan speed will not increase above level three.
7. PLASMAWAVETM ON/OFF - Turn on the Plasma generator by pressing the PLASMA button on the remote or the POWER button on the unit.
8. POWER MODE - Turn unit on/off, change mode between Energy save mode, and change the fan speed by pressing the POWER/MODE button.
8
6
SPEED
MO DE
ODO R LEV EL
REP LACE FILTER
HIG H LOW
AUTO
ODO R SEN SOR
MOD ESLE EP
SPE ED
TUR BO
1 2 3
SPEED
MO DE
ODO R LEV EL
REP LACE FILTER
HIG H LOW
AUTO
ODO R SEN SOR
MOD ESLE EP
SPE ED
1
TUR BO2 3
DISPLAY PANEL (5000B)
1
2
1. REPLACE FILTER INDICATOR - The
indicator will signal when to replace the lter cassette.
2. FAN SPEED INDICATOR - Shows current fan speed setting.
3. MODE (AUTO/SLEEP) - The unit is set to default to AUTO mode when it is rst turned on. Smart sensors will automati­ cally sense the amount of impurities in the air, and adjust the fan speed accord­ ingly. When set on SLEEP mode unit will work on Ultra-Quiet mode and dim the control panel lights.
3
5
6
4
7
4. ODOR LEVEL - Shows current odor
pollutant level in your room.
5. SPEED/MODE - Change the fan speed and modes between AUTO and SLEEP.
6. POWER BUTTON - Turn unit on and off.
7. ODOR SENSOR - Automatically monitor
odor pollutant level and adjust fan speed accordingly.
7
OPERATION
AUTOMATIC OPERATION
The unit is set to default to Automatic operation when it is rst turned on. The air cleaner will automatically sense the amount of impurities in the air, and adjust the fan speed accordingly.
PART IS
BLINKING
MANUAL OPERATION
After you turn on the unit, you can switch to manual operation by using the FAN CONTROL button on the remote control or the FAN SPEED button on the unit. * 5000B does not come with a remote control.
1, 2, 3, 4 AND TURBO Select your desired speed. The TURBO level, the highest fan speed, can be activated manually for maximum air circulation. *In case of 5000B, there are four speed levels: 1,2,3, and TURBO.
• PLASMA ON/OFF (5000 AND 5000S)
Activate PlasmaWaveTM by pressing PLASMA button on the unit and remote. (5000 and 5000S) * In case of 5000B, PlasmaWaveTM feature is always on for maximum result.
• TIMER (5000 AND 5000S)
Set the timer for 2 or 4 hours by pressing the TIMER button on the remote or the unit. The unit will stop operating when the set time is up. Cancel the timer by pressing the TIMER button until the 2- and 4-hour indicator light on the unit disappears.
room is light, the unit will revert to its previous settings. Sleep mode provides the lowest, quietest fan setting and a dimmed display panel.
DUST AND ODOR SENSORS
*5000B is odor sensor only. The dust and odor sensors show elevated levels of air quality—green, orange, and red. The green light indicates acceptable dust and odor levels, the orange light indicates high levels, and the red light indicates very high levels. If the unit is set on Automatic operation, it will adjust fan speeds to compensate for increased or decreased levels of air pollution.
Odor Sensor The odor sensor responds to cigarette smoke and pet odors, as well as other air contaminants such as insecticides, cosmetics, alcohol, or aerosol sprays.
LOW
MEDIUM
Indoor Odor Volume
Dust Sensor The dust sensor detects particles in the air such as cigarette smoke, dust, and pollen.
HIGH
• SLEEP MODE
Use the TIMER button on the display or remote to manually turn the light sensor on or off. With the light sensor on, the unit will automatically operate in Sleep mode when the room is dark. When the
LOW
MEDIUM
HIGH
Indoor Dust Volume
8