ONE YEAR LIMITED WARRANTY ON WINIX PLASMAWAVE™ AIR CLEANER
If this air cleaner fails due to defects in material or workmanship within one year from the
date of purchase, return it to place of purchase and you will receive a new one free of
charge.
• This warranty does not include the air cleaner’s replaceable lter cassette; that is an
expendable part that can wear out from normal use before one year expires.
• This warranty is void if this product is used for commercial or rental purposes.
• This warranty gives you specic legal rights, and you may also have other rights, which
vary from state to state.
PACKAGE CONTENTS
• Winix PlasmaWave™ Air Cleaner
• Remote Control (1 unit)
• Batteries (2 AA batteries)
• Operator's Manual
SAFETY INSTRUCTIONS
Thank you for purchasing a Winix air
cleaner. Please read this manual carefully
before using. This product is for household
use only.
IMPORTANT CAUTIONS FOR USING
YOUR AIR CLEANER
WARNING:
manual to reduce the risk of electric shock,
short circuit, and/or re:
• Do not repair or modify the unit unless
specically recommended in this manual.
All other repairs should be completed by
a qualied technician.
• The plug for this unit is polarized with
one blade wider than the other. Do not
force the plug into an electrical outlet. Do
Follow the instructions in this
not alter the plug in any way. If the plug
does not t into the outlet, reverse the
plug. If it still does not t, contact a qualied
technician to install a proper outlet.
• Do not use if the power cord or plug is
damaged or the connection to the wall
outlet is loose.
• Use AC 120V only.
• Do not damage, break, forcefully bend,
pull, twist, bundle, coat, pinch, or place
heavy objects on the power cord.
• Periodically remove dust from the power
plug. This will reduce the chance that
humidity will accumulate, which
increases the risk of electric shock.
• If the power plug is damaged, it must be
replaced by the manufacturer or a
qualied technician.
2
• Remove the power plug from the outlet
before cleaning the unit. When removing
the power plug, grasp by holding the plug
itself, never hold by the cord.
• Remove the power plug from the outlet
when the unit is not in use.
• Do not handle the power plug with wet
hands.
• Do not operate the unit when using
indoor smoke-generating insecticides.
• Do not clean unit with benzene or paint
thinner. Do not spray insecticides on the
unit.
• Do not use the unit where it is humid or
where the unit may get wet, such as in a
bathroom.
• Do not insert ngers or foreign objects
into the air intake or outlet.
• Do not use the unit near ammable
gases. Do not use near cigarettes,
incense, or other spark-creating items.
PRODUCT SPECIFICATIONS
• Unit will not remove carbon monoxide
emitted from heating appliances or other
sources.
IMPORTANT INSTRUCTIONS FOR
USING YOUR AIR CLEANER
• Do not block the intake or outlet vents.
• Do not use near hot objects, such as a
stove. Do not use where the unit may
come into contact with steam.
• Do not use the unit on its side.
• Keep away from products that generate
oily residue, such as a deep fryer.
• Do not use detergent to clean the unit.
• Do not operate without a lter.
• Do not wash and reuse the True HEPA Filter.
WAC-5000
Area Served 270 sq. ft.180 sq. ft.270 sq. ft.
CADR
Power
Supply
Power Rate Low 6W, Turbo 70WLow 6W, Turbo 50WLow 6W, Turbo 70W
Fan Speed5 Speeds5 Speeds4 Speeds
Control Type Auto/ManualAuto/ManualAuto/Manual
Dust Sensor YesYesNo
Odor Sensor YesYesYes
Timer2 and 4 hours2 and 4 hoursNo
Sleep Mode YesYesYes
Control
Dimension16.3”(W) X 8.5”(D) X 21.7”(H) 13.8”(W) X 8.1”(D) X 18.5”(H) 16.3”(W) X 8.5”(D) X 18.5”(H)
Weight17 lbs13.2 lbs13.0 lbs
184/175/197
(Dust/Smoke/Pollen)
AC 120V/60(Hz)AC 120V/60(Hz)AC 120V/60(Hz)
1. Washable Anti-Bacterial
Pre-Filter
2. True HEPA Filter
3. Nano-Silver Mesh
4. Washable Carbon Filter
5. PlasmaWave™
YesYesNo
WAC-5000SWAC-5000B
126/117/138
(Dust/Smoke/Pollen)
1. Washable Anti-Bacterial
Pre-Filter
2. True HEPA Filter
3. Nano-Silver Mesh
4. Washable Carbon Filter
5. PlasmaWave™
184/175/197
(Dust/Smoke/Pollen)
1 Carbon Pre-Filter
1 HEPA Filter
1. Carbon Pre-Filter
2. HEPA Filter
3. PlasmaWave™
3
AIR CLEANER FEATURES
NOTE: The features of your air cleaner may vary according to model.
• Ultra-Quiet Operation
This Winix air cleaner has a multi speed fan with ultra-quiet operation that
is ideal for nighttime operation.
• Easy Maintenance
Winix air cleaners are simple and
economical to maintain. For optimum
performance, replace complete lter
cassette when REPLACE FILTER
indicator light is on.
• Smart Dust and Odor Sensors
The 5000 air cleaner is equipped with
digital sensors that automatically monitor
air quality. As dust or odor levels change,
fan speeds will adjust automatically.
*5000B is equipped with only odor
sensor.
• Simple Operation
Winix air cleaners have a remote
control and user-friendly display for your
convenience.
• Energy Savings
When set on Energy Savings mode, fan
speed will not increase above level three.
Winix air cleaners are Energy Star
compliant.
FRONT SIDE
PlasmaWave
MULTI-STAGE CLEANING
Air undergoes ve (5000 & 5000S) or
three (5000B) separate processes before
returning, freshened and cleaned,
to the room.
• Washable Anti-Bacterial Pre-Filter
(5000 & 5000S)
This reusable lter collects large
particles, pollen, pet hair, lint, etc.
• Carbon Pre-Filter (5000B)
Very effective Carbon lter sheet collects
large particles, dust, pollen, pet hair, and
lint as well as odors caused by cigarette
smoke, organic decay, and cooking.
• True HEPA Filter (5000 & 5000S)
Captures 99.97% of particles and
impurities as small as .3 microns
including smoke, dust, pollen, mold
spores, and pet dander.
• HEPA-type Filter (5000B)
Captures 99% of particles and
impurities including smoke, dust, pollen,
mold spores, and pet dander.
• Nano-Silver Mesh (5000 & 5000S)
A shield of silver particles one billionth
of a meter in size neutralizes bacteria
TM
on contact.
Power Plug
(Image shown here
for 5000 and 5000S)
Display Panel
DC Motor
Washable Nano-Silver
Mesh/Carbon Filter
Cassette Frame
True HEPA Filter
Pre-Filter
4
Front Panel
TOP SIDE
Air Outlet
Remote
Control
Cradle
• Washable Carbon Filter
(5000 & 5000S)
Activated granular carbon effectively
collects chemical vapors and odors
caused by cigarette smoke, organic
decay, and cooking.
AIR CLEANER SET-UP
• PlasmaWave™ (All)
In the nal stage of cleaning, Winix
PlasmaWave
TM
technology generates
both positive and negative ions to create
plasma clusters which instantly neutralize
viruses, bacteria, chemical vapors and
odors in the air.
NOTE: Follow these instructions for best
results.
• Place unit at least 7 feet from equipment
that emits electric waves such as
televisions or radios.
• Place unit at least 2 feet from the wall.
• Keep sensors away from drafty areas.
• Keep curtains away from sensors, as
they may interfere with air intake/outlet.
• Place unit on a stable surface with plenty
of air circulation.
1. Remove protective lm from the
control panel.
2. Remove the front
panel by grasping
the bottom outside
edges and gently
pulling toward you.
3. Pull out the lter
cassette by grasping
the tabs located on
each side of the lter
cassette. (There are
no tabs on 5000B
HEPA lter.)
5. Return the lter
cassette into the
main unit.
6. Replace the front panel
by hooking the front
panel on the top of the
unit. Swing panel in by
pushing gently until the
panel snaps into place.
7. Plug in the power cord to a wall outlet.
8. Press POWER button until short
“beep” is heard.
For the rst 4 minutes after turning the
unit on, the dust and odor indicators will
ash while the unit measures air quality.
4. Remove the plastic
wrap from the lter
cassette.
5
DISPLAY PANEL (5000 and 5000S)
2
1
3
1. DUST & ODOR SENSORS -
Automatically monitor air quality and
adjust fan speed accordingly.
2. REPLACE FILTER INDICATOR - The
indicator will signal when to replace the
lter cassette.
3. TIMER - Indicates timer setting or
continuous mode.
4. FAN SPEED INDICATOR - Shows
current fan speed setting.
5
4
6
7
1
5. SLEEP MODE - The unit will work on
Ultra-Quiet mode and dim the control
panel lights.
6. AUTO (NORMAL/ENERGY SAVE) -
The unit is set to default to NORMAL
(Automatic operation) when it is rst
turned on. Smart sensors will automati cally sense the amount of impurities in
the air, and adjust the fan speed accord ingly. When set on ENERGY SAVE
mode, fan speed will not increase
above level three.
7. PLASMAWAVETM ON/OFF - Turn on
the Plasma generator by pressing the
PLASMA button on the remote or the
POWER button on the unit.
8. POWER MODE - Turn unit on/off,
change mode between Energy save
mode, and change the fan speed by
pressing the POWER/MODE button.
8
6
SPEED
MODE
ODORLEVEL
REPLACEFILTER
HIGHLOW
AUTO
ODORSENSOR
MODESLEEP
SPEED
TURBO
123
SPEED
MO DE
ODO R LEV EL
REP LACE FILTER
HIG HLOW
AUTO
ODO R SEN SOR
MOD ESLE EP
SPE ED
1
TUR BO23
DISPLAY PANEL (5000B)
1
2
1. REPLACE FILTER INDICATOR - The
indicator will signal when to replace the
lter cassette.
2. FAN SPEED INDICATOR - Shows
current fan speed setting.
3. MODE (AUTO/SLEEP) - The unit is set
to default to AUTO mode when it is rst
turned on. Smart sensors will automati cally sense the amount of impurities in
the air, and adjust the fan speed accord ingly. When set on SLEEP mode unit will
work on Ultra-Quiet mode and dim the
control panel lights.
3
5
6
4
7
4. ODOR LEVEL - Shows current odor
pollutant level in your room.
5. SPEED/MODE - Change the fan speed
and modes between AUTO and SLEEP.
6. POWER BUTTON - Turn unit on and off.
7. ODOR SENSOR - Automatically monitor
odor pollutant level and adjust fan speed
accordingly.
7
OPERATION
AUTOMATIC OPERATION
The unit is set to default to Automatic operation when it is rst turned on. The air cleaner will
automatically sense the amount of impurities in the air, and adjust the fan speed accordingly.
PART IS
BLINKING
MANUAL OPERATION
After you turn on the unit, you can switch
to manual operation by using the FAN
CONTROL button on the remote control or
the FAN SPEED button on the unit.
* 5000B does not come with a remote control.
• 1, 2, 3, 4 AND TURBO
Select your desired speed. The TURBO
level, the highest fan speed, can be
activated manually for maximum air
circulation.
*In case of 5000B, there are
four speed levels: 1,2,3, and TURBO.
• PLASMA ON/OFF (5000 AND 5000S)
Activate PlasmaWaveTM by pressing
PLASMA button on the unit and remote.
(5000 and 5000S)
* In case of 5000B, PlasmaWaveTM
feature is always on for maximum result.
• TIMER (5000 AND 5000S)
Set the timer for 2 or 4 hours by
pressing the TIMER button on the
remote or the unit. The unit will stop
operating when the set time is up.
Cancel the timer by pressing the TIMER
button until the 2- and 4-hour
indicator light on the unit disappears.
room is light, the unit will revert to its
previous settings. Sleep mode provides
the lowest, quietest fan setting and a
dimmed display panel.
DUST AND ODOR SENSORS
*5000B is odor sensor only.
The dust and odor sensors show elevated
levels of air quality—green, orange, and
red. The green light indicates acceptable
dust and odor levels, the orange light
indicates high levels, and the red light
indicates very high levels. If the unit is set
on Automatic operation, it will adjust fan
speeds to compensate for increased or
decreased levels of air pollution.
• Odor Sensor
The odor sensor responds to cigarette
smoke and pet odors, as well as other
air contaminants such as insecticides,
cosmetics, alcohol, or aerosol sprays.
LOW
MEDIUM
Indoor Odor Volume
• Dust Sensor
The dust sensor detects particles in the air
such as cigarette smoke, dust, and pollen.
HIGH
• SLEEP MODE
Use the TIMER button on the display or
remote to manually turn the light sensor
on or off. With the light sensor on, the
unit will automatically operate in Sleep
mode when the room is dark. When the
LOW
MEDIUM
HIGH
Indoor Dust Volume
8
Loading...
+ 19 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.