xPlease read and follow all safety rules and instructions in
this manual before operating.
xThe product warranty is printed on the back of this guide,
so please keep it in a safe place for future use.
xThis product is manufactured for use only in USA/CA
CONTENTS
3-Stage Air Purification 3
Controls 4
Set Up
Where to use 5
Installing the filters 6
Safety Instructions
Safety and Cautions 8
Operation
Initial Operation 9
Modes of Operation 10
Features and Settings 11
Care and Maintenance
Filter Care 13
Cleaning Care 17
Troubleshooting
Frequently Asked Questions 18
Unit Specifications 20
Product Warranty 22
This product is suitable for 120V only.
English
5300-2
2
3-STAGE AIR PURIFICATION
Odor
sensor
Power cord with plug
(This product is suitable for
120V only.)
➌ PlasmaWave
®
Light sensor
Control Panel / Display Panel
➋ True HEPA filter
➊ Odor Absorbing Carbon
Filter
Pre-filter
Front panel
PACKAGE
CONTENTS
English
➊ Unit
➋ Pre-filter / (4) Odor
Absorbing Carbon Filters /
True HEPA Filter
➌ User Manual
5300-2
3
CONTROLS
Air
Outlet
Vent
PlasmaWave® Indicator
Indicates whether
PlasmaWave
disabled.
Mode Button
Press to cycle through
and set the desired
mode of operation
(Auto, Sleep).
Air Quality
Indicator
Color-coded LED
indicates one of
three levels of air
quality.
®
is enabled or
Timer Indicator
If timer has been set, the
LED light indicates the set
time of operation.
Fan Speed
Indicator
Indicates the
current fan speed.
PlasmaWave® Button
Enables or disables
PlasmaWave
®
.
Power Button
Turns the unit on
or off.
Fan Speed Button
Enables Manual operation of the
unit. Press to cycle through and
set the desired fan speed (Low,
Medium, High, Turbo).
Reset Button
After replacing a filter,
press the RESET button
for at least 5 seconds.
Odor Sensor
When in Auto
Mode, detects the
amount of odor in
the environment
to adjust fan
speeds.
Light Sensor
Detects the
Timer Button
Press to cycle
through and set
desired length of
operation (1hr,
4hr, 8hr,[NO
TIMER])
amount of
ambient light
within the
environment,
to adjust the
brightness
of the LED
indicators.
Change Filter Indicator
LED light indicates when it is time to
change the filter.
English
5300-2
4
WHERE TO USE
Allow 12 ~ 18 in. of space between TVs, radios, and other electronic products
electromagnetic interference from certain electronics may cause product malfunction.
Place indoors away from direct sun light
direct exposure may cause product malfunction or failure.
Only place on hard, flat surfaces
flimsy or slanted surfaces may result in abnormal noise and vibrations.
WARNING
Do not use around mist or fumes from
industrial oil or around large quantities of
metallic dust
Do not install in any sort of motor or
transport vehicle (trucks, boats, ships, etc.)
Do not place near any flammable materials
(aerosols, fuel, gases etc.)
Do not place below any electrical outlet
Follow these instructions to reduce the risk of serious
injury or death and to reduce risk of damaging the unit.
Do not place around heating elements
Do not place in an area with excessive
amounts of noxious gases
Do not have unit facing into wind or draft
Do not place in excessively humid areas
where unit may become wet
This unit is not intended to be used to preserve documents or in art conservation.
English
5300-2
5
INSTALLING FILTERS
This product comes with all the required filters. The protective plastic
wrap must be removed from the filters before use
※ Operating the unit without removing the plastic wrap may result in
product failure.
※ Unplug and make sure the unit is turned off before installing filters.
① Remove the front panel by grasping
its upper edge and gently pulling
forward.
Latch
② Remove the filters from the unit, they
are protected inside a plastic wrap
③ Remove filters from protective plastic
wrap.
•Operating the unit without removing filters
from plastic wrap may cause abnormal
noise, deformation, or fire as a result of
overheating.
•Refer to pages 17 - 18 for details on how to replace filters.
tabs into the slots on either side of
the lower part of the unit, then rotate
upward to insert the upper tabs into
the slots at the top part of the unit until
sides audibly click into place.
True HEPA
3
filter
Carbon filter
2
Pre-filter
1
⑤ Replace the front panel by first
Latch
inserting the latch at the bottom
edge into the base of the unit, then
rotate the panel upward toward the
top of the unit until the magnets
pull the lid closed.
⑥ When to service and replace filters:
FilterIndicator Light
1 Pre-filter
2 Carbon filter
3 True HEPA filter
※ Intervals between filter replacement may vary depending on environment.
※ For optimal use, Pre-filter can be cleaned once every 14 days which can extend
the life of other filters.
none
none
When to
service
Clean once
every 14 days
Can NOT be
WASHED
When to replace
Permanent
Replace every 3
months
Lasts up to
12 months
To purchase replacement
Winix filters:
(877)-699-4649
www.winixamerica.com
English
5300-2
7
SAFETY AND CAUTIONS
Before operating this equipment, carefully read and follow these safety
cautions
Ensure filters are inserted before running unit
running unit without filters can shorten the units life and cause electric shock or injury.
Be sure foreign objects are NOT inserted into the vents on the unit
objects can include pins, rods, and coins.
Do not touch any part of the interior of the unit with wet hands
the high voltage may cause electric shock.
Ensure unit intake and outlet vents do not become blocked
blockage may lead to increased internal termperatures causing product failure and derformation.
Do not use the unit as a step stool or place heavy objects on it
personal injury may occur or product failure and deformation.
WARNING
Do not pull on the power cord when
unplugging the unit
If the unit becomes submerged in water,
unplug it and contact customer service
Do not plug additional appliances into the
same outlet or power supply
Unplug unit when not in operation for
extended periods of time
English
Follow these instructions to reduce the risk of serious
injury or death and to reduce risk of damaging the unit.
Do not tie or knot power cord when unit
is in operation
Do not unplug or move the unit while in
operation
Do not touch the plug with wet hands
Cord can become damaged by forcefully
bending, pulling, twisting, bundling,
pinching or placing heavy objects on it
5300-2
8
INITIAL OPERATION
①
Insert the power cord into an electrical
outlet.
②
Press the ‘Power’ button.
•During the first 30 seconds of power up, the Air Quality
Note
Indicator will cycle through Blue, Yellow and Red colors. The
Smart Sensors take approximately 4 minutes to gauge the air
quality in the environment, after which normal operation will
begin.
③
By default, when the unit first powers
on, the mode will be set to Auto with
PlasmaWave
•When in Auto mode, the fan speed will
be automatically adjusted according to
the environments air quality.
•PlasmaWave
airborne contaminants.
Note
English
®
enabled.
®
works to remove harmful
•In Auto mode, as the indoor air quality improves, the fan
speed will automatically be reduced to Low.
•When the unit is running, you may hear a chirping or buzzing
sound. The sound is from large particles passing through
PlasmaWave
failure. To disable PlasmaWave
®
, it is normal and does not signify product
®
, see page 12.
5300-2
9
AUTO & SLEEP
1. Auto Mode
Enables auto operation based on the unit's air quality Smart Sensors.
① Press the Mode button to select
Auto mode.
•The LED ‘Auto’ light will indicate
when Auto mode is activated, and
operation will begin.
Note
•When in Auto mode the fan speed is automically adjusted
according to the indoor air quality. As the indoor air quality
improves, the fan speed will automatically be reduced. If the
indoor air quality decreases, the fan speed will automatically
increase.
2. Sleep Mode
Press the Mode button to select
Sleep mode.
•The LED "Sleep" light will indicate when
Sleep mode is activated, and operation will
begin.
• When Sleep mode is selected, the fan speed is automatically
Note
English
set to Low. The fan speed can be manually changed by
pressing the Fan Speed button, changing the unit into manual
mode.
• When Sleep Mode is activated, the Air Quality Indicator LED
light is disabled.
5300-2
10
MANUAL & TIMER
3. Manual Mode (setting fan speed)
Users can opt to manually set the fan speed to Low, Medium, High, or
Turbo.
① Press the Fan Speed button to set
the desired fan speed.
• When Manual Mode is selected, Auto Mode is automatically
Note
4. Timer
The timer can be set to let the unit run for a specified period of time.
disabled.
① Press the Timer button to select
the desired length of time.
•When the Timer LED light will indicate
the selected length of operation.
•Every time the Timer button is
pressed, The Timer LED light will
cycle through the settings, (1hr, 4hr,
8hr, [NO TIMER]).
English
5300-2
11
PLASMAWAVE® & AIR QUALITY INDICATOR
소피아 1
5. PlasmaWave
By default, PlasmaWave® is enabled whenever the unit is powered on.
① Press the Plasmawave button,
®
when the unit is on, to enable or
disable this feature.
•In Auto mode, as the indoor air quality improves, the fan
Note
speed will automatically be reduced to Low.
•When the unit is running, you may hear a chirping or buzzing
sound. The sound is from large particles passing through
PlasmaWave
failure.
®
, it is normal and does not signify product
6. Air Quality Indicator
When on, the LED light will indicate the current indoor air quality
according to three levels: BLUE (good), AMBER (fair), RED (poor).
Note
English
Air Quality Indicator
• Air quality level is displayed on the indicator, based on the
Smart Sensors. Depending on the immediate environment,
the indicator may change frequently in color or stay the same
for lengthy periods of time.
5300-2
12
FILTER CARE
1. Know The Filters
When the Check Filter indicator LED is on, it is time to replace the True
HEPA filter.
FilterIndicator Light
1 Pre-filter
2 Carbon filter
3 True HEPA filter
※ Intervals between filter replacement may vary depending on environment.
※ For optimal use, Pre-filter can be cleaned once every 14 days which can extend
the life of other filters.
none
none
When to
service
Clean once
every 14 days
Can NOT be
WASHED
When to replace
Permanent
Replace every 3
months
Lasts up to
12 months
To purchase replacement
Winix filters:
(877)-699-4649
www.winixamerica.com
Carbon filter / True
HEPA filter
English
• The filters’ life varies depending on the level of pollutants in
Note
the air. The more dust present in the environment, the more
dust accumulates in the filters, shortening the life.
• If the filters are heavily soiled or have a bad odor, or if the fan
strength is significantly weakened, replace filters even if the
Change Filter indicator has not yet turned on.
5300-2
13
FILTER CARE
2. Removing Filters
Turn the unit power off before removing filters.
Latch
Tabs
▶▶
Pre-filter
①
Remove the front panel by grasping its upper edge and gently pulling
forward.
②
Press on the Pre-filter tabs near the top of the filter, release and
remove.
③
Pull out the Carbon filter and True HEPA filter.
3. Preparing New Filters
①
Remove replacement filters from
protective plastic wrap.
•Operating the unit without removing
filters from plastic wrap may cause
abnormal noise, deformation, or fire as
a result of overheating.
English
NOTICE
•For optimal performance, only Winix filters should be used
with this unit.
5300-2
14
FILTER CARE
4. Replacing Filters
True
HEPA
filter
▶
Carbon
filter
① Insert the True HEPA filter first, then the Carbon filter.
② Insert the Pre-filter.
•
Insert bottom tabs of the Pre-filter into the slots on either side of the lower
part of the unit, then rotate upward to insert the upper tabs into the slots at the
top part of the unit until sides audibly click into place.
③
Replace the front panel by first inserting the latch at the bottom
Tabs
Pre-filter
Latch
▶
edge into the base of the unit, then rotate the panel upward toward
the top of the unit until the magnets pull the lid closed.
5. Resetting The Unit
①
After replacing the filters, turn the
power onto the unit and then use
a thin object, such as a paper clip,
to press the RESET switch for 5
seconds.
English
5300-2
15
FILTER CARE
6. Cleaning the filters
Intervals between filter cleaning may vary depending on the air quality.
② Use a vacuum cleaner or soft
brush to clean the Pre-filter. If it
is excessively soiled, rinse in room
temperature water.
•Do not use detergent or soap.
•Allow the filter to dry for 24 hours or
more before using.
If the pre-filter becomes damaged or in any way needs replacement:
Please contact Winix
(877)-699-4649
www.winixamerica.com
NOTICE
English
•Do not use benzene, alcohol, or other volatile fluids, which
may cause damage or discoloration.
•The Pre-filter is resusable after cleaning, ensuring it is
completely dry.
•Do not use hot water over 104
paint thinner.
•After washing the filter, allow it to dry completely in a well
ventilated area. Otherwise, it may develop a bad odor.
o
F or volatile fluids such as
5300-2
16
CLEANING CARE
2. Cleaning the Exterior & Interior
① Wipe with a soft damp cloth
using room temperature water.
Afterwards, wipe it down with a
clean dry cloth.
•To keep unit in peak condition, clean
every 1-2 months.
① Open the front panel and clean the
interior with a vacuum cleaner.
•For optimal perfomance, clean every
1-2 months.
English
NOTICE
•When cleaning the unit, always unplug the power cord first
and then wait until the unit has cooled down.
• Never disassemble, repair, or modify this unit yourself.
•Do not use flammable sprays or liquid detergents.
•Do not allow children to clean or maintain the unit.
•Before cleaning or maintaing, ensure unit is unplugged.
5300-2
17
FREQUENTLY ASKED QUESTIONS
ProblemCheck / Actions to take
•Is the plug securely attached to the outlet?
-Make sure the outlet has power going to
It does not
turn on at all.
it, and ensure the plug is secured.
•Is there a power outage?
-Check to see if other lights and electrical
equipment are working and try again.
It doesn’t work
in Auto Mode.
English
•Has Auto Mode been selected?
-Press the Mode button until Auto Mode is
selected.
•Is the sensor blocked or clogged?
-W i p e O d o r S e n s o r w i t h w e t c l o t h , t h e n
dry.
5300-2
18
FREQUENTLY ASKED QUESTIONS
ProblemCheck / Actions to take
•
It vibrates and makes
a lot of noise.
Is it running on a slanted or uneven surface?
-Move the unit to a hard, flat, even area of
the floor.
The power plug and
outlet feel hot.
There is a
strange smell.
The fan
strength is weak.
The unit is not
purifying the air.
The display
panel is dim.
•Is the plug securely plugged in?
-Make sure the plug is properly plugged
into the outlet.
•Is it being used in a place with a lot of
smoke, dust, or odors?
-Clean the air intakes on either side and
clean the pre-filter.
-Replace the Carbon and True HEPA filter.
•Is the Check Filter indicator light on?
-Change the filters as required.
•I
s the Light Sensor blocked by debris?
-When Auto Mode is on, Sleep Mode
is automatically activated when the Light
Sensor detects that the room is dark.
English
5300-2
19
UNIT SPECIFICATIONS
Model Name
5300-2
Power VoltageAC120V/ 60Hz
Power Rate70W
Room Area Served360ft
2
Dimensions14.9 in(W) x 7.8 in(D) x 23.6 in(H)
Weight17.6 lbs
Replacement Filter
Pre-Filter
Filter A / Item: 115115
Part #: 4521-0012-03
※ The exterior, design, and product specifications may be changed without prior notice
to improve product performance.
❖ Information regarding ENERGY EFFICIENCY RATING LABEL
The energy costs indicated on the ENERGY EFFICIENCY RATING LABEL may differ
from your actual energy costs, depending on your energy consumption, usage
hours, and billing changes, such as utility price increases.
Warning: Change or modifications to this unit not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, and may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television reception,
which can be dteremined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures.
x
Reorient or relocate the receiving antenna.
x
x
Increase the separation between the equipment and receiver.
x
x
Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected.
x
x
Consult the dealer or on experienced radio/TV technician for help.
x
This device complies with Industry Canada's license-exempt RSSs. Operation is subject to the following two
conditions:
x
This device may not cause interference; and
x
x
This device must accept any interference, including interference that may cause undesired operation of the
x
device.
English
5300-2
20
SAFETY INSTRUCTIONS
Thank you for purchasing a Winix air purifier. This product is for household use only.
IMPORTANT CAUTIONS FOR
USING YOUR AIR PURIFIER
WARNING: Follow the instructions in
this manual to reduce the risk of
electric shock, short circuit, and/or fire.
x
Do not repair or modify the unit unless
x
specically recommended in this manual.
All other repairs should be completed by
a qualied technician.
x
The plug for this unit is polarized with
x
one blade wider than the other. Do not
force the plug into an electrical outlet. Do
not alter the plug in any way. If the does
not t into the outlet, reverse the plug.
If it still does not t, contact a qualied
technician to install a proper outlet.
x
Do not use if the power cord or plug is
x
damaged or the connection to the wall
outlet is loose.
x
Use AC 120V only.
x
x
Do not damage, break, forcefully bend,
x
pull, twist, bundle, coat, pinch, or place
heavy objects on the power cord.
x
Periodically remove dust from the power
x
plug. This will reduce the risk of shock due
to humidity build up.
x
If the power plug is damaged, it must
x
be replaced by the manufacturer or a
qualied technician.
x
Remove the power plug from the outlet
x
before cleaning the unit. When removing
the power plug, grasp by holding the
plug itself, never hold by the cord.
x
Remove the power plug from the outlet
x
when not in use.
x
Do not handle the power plug with wet
x
hands.
x
Do not operate the unit when using
x
indoor smoke-generating insecticides.
x
Do not clean unit with benzene or paint
x
thinner. Do not spray insecticides on the
unit.
x
Do not use the unit where it is humid or
x
where the unit may become wet, such as
the bathroom.
x
Do not insert ngers or foreign objects
x
into air intake or outlet.
x
Do not use use the unit near ammable
x
gases. Do not use near cigarettes, incense,
or other spark-creating items.
x
Unit will not remove carbon monoxide
x
emitted from heating appliances or other
sources.
IMPORTANT PRECAUTIONS FOR
USING YOUR AIR PURIFIER
x
Do not block the intake or outlet vents.
x
x
Do not use near hot objects, such as a
x
stove.
x
Do not use where the unit may come into
x
contact with steam.
x
Do not use the unit on its side.
x
x
Keep away from products that generate
x
oily residue, such as a deep fryer.
x
Do not use detergent to clean the unit.
x
x
Do not operate without a lter.
x
x
Do not wash and reuse the True HEPA or
x
Carbon lter.
x
Hold the handle on the back of the unit
x
to transport.
x
Do not hold by the front panel.
x
WARNING
This product contains chemicals
known to the State of California to
cause cancer and birth defects or
other reproductive harm.
English
5300-2
21
PRODUCT WARRANTY
The terms of the warranty are as follows.
1.
This product is manufactured under stringent quality control and
inspections.
2.
Warranty void if product failure is a result of negligence or misuse by the
consumer, shipping and service fees may be incurred even during the
warranty period.
3.
The warranty must be presented upon bringing the product for service.
4.
Store the warranty in a safe place, as it cannot be reissued.
5.
This warranty is valid only in the USA and Canada.
Product Name
Model Name
Purchase Date
Warranty period
Place of purchase
Place of purchase Tel.
Address
Customer
Name
Tel.
Air Purifier
5300-2
One (1) year
After purchase, be sure to complete all of the above information.
English
5300-2
22
Developed in partnership with
Drexel University
(Philadelphia, PA, USA)
Contact for product
related inquiries and
customer service
151311 Rev.A
To expedite service, please specify the model name and number, the
nature of the problem, your contact information, and your address.
x Dedicated Call Center : (877) 699-4649
x Website : www.winixamerica.com
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.