Winix 50BT User Manual

Page 1
User Manual
DEHUMIDIFIER
50BT, 70BT
Please read and follow all safety rules and instructions in
this manual before operating.
The product warranty is printed on the back of this guide,
so please keep it in a safe place for future use.
This product is manufactured for use only in USA/CA
Model
Use & Care Guide
Page 2
FOR THE HOME
Page 3
FOR THE FAMILY
Page 4
4
English
50BT, 70BT
CONTENTS
Set Up
Controls 5 Unit 6 Where to use 7
Safety Instructions
Safety and Cautions 8
Operation
Bucket 9 Gravity Drain 10
Care and Maintenance
Grill and Filter 11 Exterior 12 Bucket 13
Tro ubl esh oot ing
Frequently Asked Questions 14
Unit Specifications 16 Product Warranty 18
This product is suitable for 120V only.
Page 5
5
English
50BT, 70BT
( A ) Power: Turns the unit on or off.
( B ) Settings: Cycles through available settings; Auto, Humidity, Cycle Timer, Delay
Start, and Auto.
( C ) Fan Speed: Allows manual control of fan speeds.
( D / E ) Manual Humidity Level: Use the arrows to manually adjust the humidity level
in the environment. Down (D) decreases and Up (E) increases humidity percentage.
( F ) Fan Speed Indicator: Displays the current fan speed. When AUTO is selected, the
unit adjusts the fan speed accordingly depending on the humidity level.
( G ) Bucket Full Indicator: When the collection bucket is full this indicator will turn
on. The unit will not run until the bucket is emptied.
( H ) Display Window: Shows humidity level of environment between 35% to 70%, in
increments of 5%. Shows information when setting Cycle Timer or Delay Start.
( I ) Auto: When the unit is initially powered on, it will run in AUTO mode. The unit will
automatically set the Relative Humidity (RH) level to 50%, for normalized operation.
( J ) Humidity: Manually set the RH by pressing the Down or Up arrows when in this
setting, allowing the user to manually set their RH level, ranging from 35% to 70% in increments of 5%.
( K ) Cycle Timer: Timer feature which allows the unit to run for 3, 6, or 12 hours then
power down for 3, 6, or 12 hours. Manually set the duration by pressing the Down or Up arrows when in this setting.
( L ) Delay Start: Power the unit on at a desired delayed time. Time can be adjusted in
increments of 1 hour and ranging from 1 to 12 hours. Manually set the time by pressing the Down or Up arrows when in this setting.
HF
EAD BC
I
J
G
K
L
CONTROLS
Page 6
6
English
50BT, 70BT
Control Panel
Air Intake Vents
Water Level Window
Water Bucket
Molded Hand Grips
Air Outlet Vents
Gravity Drain Connector
Casters
Power Plug
UNIT
Always keep unit in upright position. Do not allow to tip over.
Page 7
7
English
50BT, 70BT
WARNING
Follow these instructions to reduce the risk of serious injury or death and to reduce risk of damaging the unit.
WHERE TO USE
Do not use around mist or fumes from industrial oil or around large quantities of metallic dust
Do not install in any sort of motor or transport vehicle (trucks, boats, ships, etc.)
Do not place near any flammable materials (aerosols, fuel, gases etc.)
Do not place below any electrical outlet
Do not place around heating elements
Do not place in an area with excessive amounts of noxious gases
Do not have unit facing into wind or draft
Only place on hard, flat surfaces that is secure enough to hold over 70 lbs.
Allow 12 ~ 18 in. of space between TVs, radios, and other electronic products
electromagnetic interference from certain electronics may cause product malfunction.
Place indoors away from direct sun light
direct exposure may cause product malfunction or failure.
Do not leave doors or windows open where unit is being used
the units workload will be increased and may cause malfunction or failure.
This unit is not intended to be used to preserve documents or in art conservation.
12 ~ 18 in
12 ~ 18 in
Place in a location where the temperature will not fall below 65oF
proper environment temperature will lead to maximum effectiveness
Page 8
8
English
50BT, 70BT
SAFETY AND CAUTIONS
Before operating this equipment, carefully read and follow these safety cautions
WARNING
Follow these instructions to reduce the risk of serious injury or death and to reduce risk of damaging the unit.
Do not pull on the power cord when unplugging the unit
Do not touch the plug with wet hands
Do not plug additional appliances into the same outlet or power supply
Unplug unit when not in operation for extended periods of time
Do not tie or knot power cord when unit is in operation
Do not unplug or move the unit while in operation
If the unit becomes submerged in water, unplug it and contact customer service
Cord can become damaged by forcefully bending, pulling, twisting, bundling, pinching or placing heavy objects on it
Be sure foreign objects are NOT inserted into the vents on the unit
objects can include pins, rods, and coins.
Do not touch any part of the interior of the unit with wet hands
the high voltage may cause electric shock.
Ensure unit intake and outlet vents do not become blocked
blockage may lead to increased internal temperatures causing product failure and deformation.
Do not use the unit as a step stool or place heavy objects on it
personal injury may occur or product failure and deformation.
Page 9
9
English
50BT, 70BT
OPERATION
1.
Bucket
Using this method requires the bucket to be emptied manually when full.
①
Slide the bucket out of the unit by grasping the side handles.
②
Empty the bucket in a basin with a drain; ideally a sink.
③
After the bucket is emptied, the bucket will need to be replaced by sliding the bucket back into the unit.
2.
Gravity Drain Hose
This method will allow a hose to be connected to the rear of the unit, allowing for continuous flow and disposal of any water collected from the air. (hose not provided)
①
Remove the Gravity Drain cap.
There are two options to operate the unit, bucket or Gravity Drain Hose.
Page 10
10
English
50BT, 70BT
②
Remove the bucket from the unit. Remove the DRAIN CONNECTOR from the bucket.
③
Install the DRAIN CONNECTOR to the dehumidifier by inserting fully into the gravity drain in the rear of the unit, and turning clockwise.
④
Screw a standard drain hose to the drain connector by turning it clockwise.
OPERATION
Defrost Operation
The dehumidier has a built-in defrost control that senses frost buildup on
the evaporator coils.
During defrosting, the compressor will automatically turn o; the fan will
continue running to defrost the coils.
Automatic Shut off
When the bucket is full, or when the bucket is not in the proper position,
the Bucket Full light will turn on and the unit will automatically shut o.
The unit will automatically shut o when the bucket is not seated properly
in the unit. The light will stay on until it is adjusted properly.
The unit will turn o once the set humidity level is reached, plus or minus
5% Relative Humidity (RH).
Page 11
11
English
50BT, 70BT
CARE AND MAINTENANCE
1.
Cleaning Front Grill and Air Filter
Using this method requires the bucket to be emptied manually when full.
①
Remove the bucket from the unit; the air filter is located behind the front grill.
②
Pull the filter down and away from the unit, until it is all the way out.
③
Wash the filter with water, rinse thoroughly. Air dry away from direct sunlight for at least 24 hours.
④
After cleaning and drying, replace the air filter behind the front grill and replace the bucket.
Page 12
12
English
50BT, 70BT
2.
Cleaning the Exterior
①
Clean the exterior using a soft brush or dry towel. But do not spray water directly on the unit.
②
The Front Grill can be cleaned using a vacuum cleaner or a soft brush to remove dust.
CARE AND MAINTENANCE
Page 13
13
English
50BT, 70BT
3.
Cleaning the Bucket
①
After removing the bucket from the unit, lift off the cover. Clean the inside and outside of the bucket as needed.
②
Rinse the bucket and drain.
③
Replace the bucket. Ensure float switch is not obstructed. Proper position of the bucket and float switch is required for the dehumidifier to run.
CARE AND MAINTENANCE
Page 14
14
English
50BT, 70BT
Problem Check / Actions to take
Dehumidifier does not
work when pressing the
POWER button.
Is the power cord plugged into a grounded 3-prong outlet?
- Plug the power cord securely into a grounded 3-prong outlet.
Does Bucket Full light appear after emptying the water bucket?
- Empty the water bucket and re-insert.
Dehumidifier is
operating, but the unit is
not drawing any water.
Is the compressor running as well as the fan?
- The unit may be in the defrost mode. This is noted by the fan running but not the compressor. If this is the case, regular operation will begin to run automatically.
- If both the compressor and fan are running, but the air being returned from the outlet vent is not at least 65oF or above for room temperature, then there may be a sealed system failure. Please contact customer service.
Loud noise and/or
vibration occurs during
operation.
Is the unit on a level surface?
- If not, place the unit on a level and hard
surface.
FREQUENTLY ASKED QUESTIONS
Page 15
15
English
50BT, 70BT
FREQUENTLY ASKED QUESTIONS
Problem Check / Actions to take
Odd sounds seem to be
coming from the unit.
Sounds like flowing water during and after operation.
- This is a normal sound of the refrigerant flowing through the coils.
The unit is making a pinging sound.
- This is a normal sound of expansion
and contraction caused by the change in temperatures.
Dehumidifier is not
running efficiently.
Are the grill and filter dirty?
- Clean the Front Grill and Air Filter, see p. 12
Is the indoor temperature under 65oF?
- If yes, frost can develop easily which will
inhibit the units efficiency.
Unit is discharging
warm air.
- Normal; the compress and electric motor discharge a small amount of heat which will warm the air.
Water does not drain
through the hose.
Is the Drain Connector installed correctly?
- Re-install the drain hose, see p. 9
Check the drain hose for kinks or other obstructions.
- If any are found, flatten the hose or remove
any blockages.
Page 16
16
English
50BT, 70BT
Model 50BT 70BT
Moisture Removal
50 Pint 70 Pint
Bucket Capacity
19.2 Pints
Power Supply 115V / 60Hz
Watts 480W 710W
Refrigerant
R-410a
10.22 oz.
R-410a
11.99 oz.
Relative Humidity Settings
35 - 70%
Cycle Timer
3, 6, 12 Hours
Operating Temperatures
36oF - 99oF
Unit Dimensions
14.1 in (W ) x 12.2 in (D) x 22.7 in (H)
Unit Weight
39.3 lbs 42.5 lbs
The exterior, design, and product specifications may be changed to improve product performance without prior notice.
Warning: Change or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, and may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures.
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected.
Consult the dealer or on experienced radio/TV technician for help.
This device complies with Industry Canada's license-exempt RSSs. Operation is subject to the following two conditions:
This device may not cause interference; and
This device must accept any interference, including interference that may cause undesired operation of the device.
UNIT SPECIFICATIONS
Page 17
17
English
50BT, 70BT
Thank you for purchasing a Winix dehumidifier. This product is for household use only.
IMPORTANT CAUTIONS FOR USING YOUR DEHUMIDIFIER
WARNING: Follow the instructions in this manual to reduce the risk of electric shock, short circuit, and/or fire.
Do not place the power cord near a heater.
Do not use an electrical outlet near ammable or combustible materials such as gasoline, propane, paint thinners, etc.
Do not disassemble or modify the dehumidier parts or components. It may cause electric shock and failure.
Plug in the power cord properly.
Do not turn the unit on and o by inserting or pulling out the power plug.
Do not damage the power cord or use an unspecied power cord.
Do not modify power cord length.
Do not share the outlet with another appliance.
Always plug into a grounded outlet. Not grounding unit may cause electrical shock.
Unplug the unit if it emits strange sounds, odors, or smoke.
Do not use an electrical outlet if it is loose or damaged.
Do not operate or plug in unit with wet hands or in a wet environment.
Ventilate area before operating dehumidier. Check for the presence of natural gas or the buildup of other combustible vapors.
Do not clean the dehumidier with water. Water may enter the unit and degrade the insulation resulting in an electrical shock.
If water enters the product, turn o the dehumidier's power switch, then unplug the unit. Do not plug in unit until it has been inspected by an authorized repair service.
Because the fan rotates at high speed during operation, always unplug dehumidier before attempting any recommended maintenance or cleaning.
Do not block the inlet or outlet vents. It may cause unit to fail or to operate ineciently.
Do not remove plug from outlet by pulling on the cord.
Auto is the suggested setting for typical everyday use.
Make sure the dehumidier is the correct size for the area you want to dehumidify. It is not designed to dehumidify the entire house.
For proper operation, the dehumidier should only be placed on a level oor.
Close all doors, windows and other openings to the room. The dehumidier must operate in an enclosed area to be eective.
To clean, use a soft cloth; do not use wax, thinners, or strong detergents as they may change the color of the unit or cause surface damage.
Be sure to replace the bucket properly after emptying to prevent water from collecting on the oor causing damage to some types of ooring.
Do not put a pet or house plant where it will be exposed to direct air ow. This could injure the pet or plant.
Operation without lter will cause unit failure. Insert the lter securely. Clean it every two weeks.
TIPS
WARNING
This product contains chemicals
known to the State of California to
cause cancer and birth defects or
other reproductive harm.
When not in use, turning the unit o will save energy. Unplug the dehumidier when not using for long periods of time.
When removing the lter, be aware that some metal parts may have sharp edges and may cause injury.
Do not use the water collected in the bucket for drinking purposes. It is not sanitary and could cause illness.
Do not allow children to play with this product.
Page 18
18
English
50BT, 70BT
WINIX DEHUMIDIFIERS LIMITED WARRANTY
Limited Warranty: Winix warrants the parts of the machine to be free of defects in material and workmanship and provides service and support for one (1) year from the date of purchase by the original consumer for models 50BT and 70BT.
If any part is found to be defective during the warranty period, your sole and exclusive remedy will be repair or replacement, at Winix's option and expense, of the defective part. This warranty does not apply in cases of abuse, mishandling, failure to comply with product usage standards, operation using an improper power supply (other than listed on the label), or unauthorized repair.
Winix reserves the right to charge the consumers for any additional costs incurred by Winix to provide parts or services outside of the country where the air purifier is initially sold by an authorized reseller. This warranty does not include the air cleaner's replaceable filters, which are expendable parts that wear out from normal use.
ANY IMPLIED WARRANTY, INCLUDING THAT OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED IN DURATION TO THE APPROPRIATE WARRANTY PERIOD SET FORTH ABOVE.
In no event shall Winix be liable for any consequential or incidental damages attributable to this product.
This warranty gives you specific legal rights. The duration , terms and conditions of this warranty are valid worldwide, except where different limitations, restrictions, or conditions may be required by local law.
For more details or to obtain service under this warranty, please contact your local dealer.
Page 19
Page 20
To e xp ed it e se r vi ce , pl ea s e sp ec if y th e mo de l na me an d nu mb er , th e na tu re of t he p ro bl em , y ou r contact information, and your address.
151216 Rev.2.1.1
Dedicated Call Center : (877) 699-4649 Webs ite : ww w.winixam erica.com
Contact your local dealer