Humidifier Water Line Maintenance ........................................................................... 22
Water Line Maintenance Detail 进水管道维修详细 .................................................... 23
Directory of Terms缩写语言索引 .............................................................. 24
INTRODUCTION 导言
Dear Customer:
Congratulations and thank you for purchasing a Wine Guardian® Humidifier. We believe it to be
the best wine cellar humidifier on the market and hope that you will agree.
This guide is intended to help the installer and owner of the Wine Guardian Humidifier to
properly install and maintain the equipment. In order to ensure optimal performance, the
equipment should be installed properly and have proper care and maintenance. Please read this
guide carefully, especially the safety instructions, and keep it for future reference.
This Wine Guardian Humidifier is shipped in a cardboard box. Each humidifier and humidistat is
factory assembled and tested prior to shipment. There are two models of the Wine Guardian
humidifier. The stand-alone model (see Figure 4.0) is supplied with its own grille, wall bracket
and transformer and is intended to be mounted separately and independently of the cooling unit.
The basic or integrated humidifier is intended to be mounted on a Wine Guardian cooling unit
(see Figure 6.0) and is supplied with an adapter.
Upon receipt and before opening the container, inspect the packing crates or boxes for obvious
signs of damage or mishandling. Write any discrepancy or visual damage on the bill of lading
before signing.
Find the packing slip and check for completeness of contents. Make sure it is the correct model
you ordered, including factory options and accessories.
Your Wine Guardian Humidifier has a humidistat that gets wired to the terminal strip on the
Wine Guardian unit and a drain line that requires piping to an open floor drain or condensate
pump. Inspect all equipment for any sign of damage or loose parts caused during transit.
Immediately report all visual or concealed damage to the carrier and file a claim.
NOTE: If this procedure is not followed, the shipping company may reject the claim and
the consignee may suffer the loss. Do not return the shipment to the factory.
注意:如果不遵循这一程序,船运公司可以拒绝索赔和收货人很可能蒙受损失。请不要将
设备运回工厂。
General Description 总体描述
The Wine Guardian Humidifier is a self-contained unit designed specifically for wine cellars. It
has been designed for easy installation and operation, either as a freestanding unit or mounted on
a Wine Guardian cooling unit. Wine Guardian uses a humidistat to sense and control the amount
of moisture needed to be added to the cellar. Humidifiers are not intended to remove moisture,
only add moisture. All components are of a high quality, standard commercial grade. The
freestanding humidifier also comes with a sealed, plug-in transformer and lead cord to allow the
unit to operate independently of a Wine Guardian cooling unit.
Wine Guardian Humidifiers are the evaporative drip pad-type. Air from the cellar is drawn over
a distribution pad that is saturated with water from a distribution tray. As the air passes through
the pad, it absorbs moisture through evaporation of the water. This raises the humidity of the
leaving air that returns to the cellar. Hot water is recommended for use with the humidifier;
however the system will work using cold water. Hot water increases the capacity of the
humidifier to evaporate the water as it passes through the pad. The hot water also leaves fewer
solids on the surfaces of the pad and flushes contaminants out of the pad. Excess water is
collected in the bottom trough and exits through the drain.
To avoid build-up of mineral deposits on the pad and potentially causing blockage of the air
flow, it is recommended that hard water be treated (filtered and softened). Install a 5- or 10micron in-line water filter ahead of the humidifier to keep dirt from fouling the inlet screen and
the evaporation pad inside. If the water has a high mineral content, a softener may be needed to
prevent excessive scale from building up too rapidly on the pad.
Additionally, to insure adequate wetted surfaces and to help flush away excess minerals, the
water flow is set to always have a flow of water to the drain. When operating, the humidifier will
use approximately 4 to 8 liters of water per hour depending on the water pressure in the building.
About 60% of that will pass through and go out the drain. There is a strainer and an orifice in the
2
line to restrict the flow of water but a throttling valve may be needed to keep too much water
from going to the pad. All that is needed is a steady dripping of water out of the drain to ensure
adequate wetting and flushing of the pad media. Excess water does not negatively impact the
humidifier’s operation but neither does it contribute to more humidification. The drain volume is
too much for just a bucket. A gravity drain line should be piped to an open floor or sink drain, or
a condensate pump may be used where a gravity drain is impractical. This excess drain water can
be discharged directly onto the ground. The discharge of the drain can be combined into the
condensate drain from the cooling unit.
The humidistat, located in the cellar, will automatically turn on the humidifier whenever the
cellar humidity is below the set point and turns it off when the cellar humidity reaches set point.
The recommended setpoint is 55% for wine cellars. This humidity level is high enough to
prevent corks from drying out and low enough to prevent mold from forming. When the unit
turns on, the water solenoid valve opens and the fan turns on. When mounted and connected to a
Wine Guardian cooling unit, the humidistat also controls the main fan to circulate air to and from
the cellar.
The Wine Guardian Humidifier uses a 254mm wide x 780mm high x 51mm thick expanded
coated aluminum pad. Its rated output capacity for wine cellars is 16°C and 50%RH is 6.0 liters
per day (1pd) with 16°Cwatersupply 12.5 1pd with 32°C water, and 19.3 1pd with 49°C water.
The weight of an operating humidifier is approximately 4.5kg. See Figure 1.0 dimensions.
Adapter plates – metal plates used to mount the humidifier to the different sizes of Wine
Guardian cooling units.
Cabinet – the cabinet and access doors are constructed of 0.063” gauge aluminum with a powder
coated finish. This affords corrosion protection and an attractive, maintenance-free appearance.
Areas in contact with cold temperatures are lined with a dense, closed-cell insulation to prevent
condensation.
Distribution tray – the plastic water trough into which the water drips and is distributed evenly
over the drip pad through several holes evenly spaced in the trough.
Drain – collects excess water at the bottom of the pad and is piped to an external drain.
Electrical controls – most of the electrical components and controls are located inside the
humidifier enclosure. All wiring is done in accordance with the National Electrical Code. Wires
are numbered and color coded to match the wiring diagrams.
Evaporative drip pad – the expanded metal pad through which the cellar air flows and the
water drips down the surfaces.
4
Factory tested – all Wine Guardian Humidifiers are run in the factory and tested for operational
performance prior to shipment.
Fan – turns “On” and “Off” on signal from the humidistat when humidity in the cellar is
required. The fan draws air across the evaporative drip pad to absorb moisture.
Grille – for freestanding applications only. Used to separate the inlet air from the discharge air.
Orifice – small fitting with a very small hole in the center to restrict the flow of water.
Strainer – conical shaped stainless steel screen in a plastic frame to capture any sediment in the
water and keep it from plugging the orifice.
Water solenoid valve – opens and closes to control the flow of water into the distribution trough
on signal from the humidistat.
概述
参考。见图
-
2.0
接口配板
加湿机用此金属板连接不同大小的酒卫冷却主机。
-
外壳 -外壳和检修门的构造使用
0.063
护。与低温接触面板的背面粘有致密绝缘内衬,以防结露。
英寸合金铝, 粉末涂层, 美观 ,防腐蚀,免维
分布托盘
塑料水槽接收水滴,通过均匀分布的小孔把水均匀地流到分布垫上。
-
排水
收集分布垫流下的多余的水, 用管道输出窖外。
-
电气控制
程规定。电线的编号和颜色编码,以匹配布线图。
电气元件和控制大部分位于加湿机机箱内部。所有接线工作是在与国家电气规
-
滴灌蒸发垫
扩大金属垫,又称“分布垫”,水从上滴下来,空气穿过分布垫。
-
工厂测试
所有的酒卫加湿器在工厂运行和测试,然后装船。
-
风扇
发的水分。
根据酒窖里的湿度要求湿度调节器控制风扇的“开”“关”。风扇拉过分布垫吸收后蒸
-
格栅
只为独立型加湿机使用。用来隔离进气和排气。
-
过滤塞
带小孔的过滤塞用于限制进水流量。
–
过滤网 - 锥形,带塑料框架的不锈钢屏幕用以捕捉水中沉积物,保证带小孔的过滤塞不
堵塞。
电磁水阀 – 进水槽内水的流动(打开和关闭)由湿度控制器控制。
5
Dimensional Drawing 尺寸图
303m
256m
351mm
327mm
12.7mm
151mm
256 mm
(所有尺寸以
MM
为单位)
(All dimensions in Metric MM)
Figure 1.0
6
Component Parts Cutaway Drawing 构件切角图
Figure 2.0
7
Wiring Diagram
接线图
Figure 3.0
8
Safety 安全
CAUTION
CAUTION
The Wine Guardian Humidifier uses only 24-volt power. However, that power comes from a
transformer, which uses 120-volt power. Therefore, before servicing the humidifier, be sure to
disconnect the main power to the cooling unit or to the humidifier.
The water supply to the humidifier may be hot. Turn off the humidifier and allow the water to
cool before servicing the humidifier.
To check for any possible non-visible shipping damage, you may wish to test the unit before
actually installing it. To do so, remove the unit from its packaging and set it on any sturdy level
surface. If a freestanding unit, plug in the unit. If the unit is to be mounted into a cooling unit,
you need to wire the humidifier to the cooling unit and the cooling unit must be turned on. Then
turn on the rocker switch on top of the humidifier. The switch light should come on. This
indicates the unit has power. Set the humidistat above the room humidity. The unit should now
come on. The water solenoid should open and the fan should come on. Listen for any unusual
noise or vibration. Turn the humidistat below the room condition and the unit should go off.
1) Mount the face grille onto the humidifier box so that the separation plate slides in on top of
the fan and between the insulation on the sides. The two metal tabs (top and bottom) should
slide in between the insulation and the metal wall. Install two screws (top and bottom) into
the metal tabs to secure the grille in place.
2) Determine where unit will be mounted.
a. If wall mounted, use metal bracket provided. Secure bracket to wall with small hole on
top, larger hole on the bottom. Install humidifier onto the bracket with drain tube on
bottom. Secure the bracket to the humidifier at the top using the screw provided.
b. If shelf mounted, drill a 1” diameter hole in the shelf and mount humidifier with the drain
on the bottom through the hole.
c. If through-the-wall mounted, frame opening to fit outside dimension of unit. Allow for
drain line, flanges and water line. Slide unit into opening and secure into place (flanges at
front can be used). Fill in any gaps between the humidifier and the wall framing with
insulation.
11
独立安装
1)安装加湿机格栅框,分离板应从顶部插入风扇上端和绝缘层之间。两个金属片(顶部
和底部)用以固定插入绝缘层和金属墙的分离板。安装两个螺丝穿过金属片(顶部和底
部)固定格栅。
2)确定机器安装位置。
a 如果是挂墙式安装,使用提供的金属支架。将支架固定到墙上,顶部小洞,底部大
洞。装入加湿机时,注意底部的排水管。使用提供的螺丝固定加湿机顶部。
b 如果用货架安装,货架上应钻一个 1 英寸直径的小孔,加湿机底部排水管就此穿
过。
c 如果是穿墙式安装,打孔大小应以设备外形尺寸为准。注意允许排水管线,进水管
和法兰盘的空间。机器插入后应固定(法兰盘用于前端)。用保温绝缘材料填补加湿机与
墙体框架 之间空间漏洞。
NOTE: In all mounting arrangements make sure the humidifier is level and plumb in all
directions.
3) Install a 6.35 mm water line from the water supply into the opening on the top of the
humidifier. Use flexible tubing to allow the unit to be rotated. A shut-off valve (not provided)
is recommended to isolate the humidifier from the water system when needed.
4) Install a 12.70 mm flexible drain line from the bottom of the humidifier to an open drain or
connect into the drain line from the cooling unit.
5) Install the humidistat on the wall where it is open to the cellar and can be read easily,
approximately 1.5 metres above the floor.
6) Connect the wires from the humidifier to the terminals on the transformer. Plug the
NOTE: Integrated humidifiers can be mounted in either of the two side openings of the
cooling unit on the cooling or evaporator end only. Do not mount the humidifier on the
condenser end of the unit. If a duct connection is in that position, move the duct
connection to the top or other side.
注:集成式加湿机可以安装在冷却装置两个侧面开口或蒸发器尾端。不要把加湿机安装在
冷凝器尾端。如果管道已安装在这个位置,移动管道连接到顶部或另一侧。
1) Remove side access panel on the side of the cooling unit where you wish to mount the
humidifier.
打开冷却主机侧面的检修口, 选好加湿机安装位置。
2) Select the proper adapter plate for the cooling unit, (WG 40, WG 75 and WG100 units use
the same adapter plate; WG175 units require a larger adapter plate that must be ordered
separately) and install in the side opening using the screws from the panel removed above.
The adapter plate allows the humidifier to be mounted in either a forward position or back
toward the center by simply rotating the adapter plate 180 degrees.
Each Wine Guardian Humidifier comes with a humidistat and 7.6 metres of humidistat cable prewired to unit. The unit also comes with 1.5 metres of 3-wire, 24-volt power cable that connects
to the terminal on the side strip of the Wine Guardian Unit. (See Step 3 next page.) If you need to
remove the wires, please note the color-coding and replace the wires in the correct location.
After the wires are re-installed, test with a slight pulling motion back on the wire. If additional
wiring is needed, it can be spliced onto the factory-furnished wire. Be sure to match colors for
continuity and to insulate each wire separately with electrical tape
BE SURE THAT EACH COLORED WIRE IS IN ITS PROPER COLOR-CODED SLOT ON THE TERMINAL
STRIP AND THAT THEY ARE TIGHT. MIS-CONNECTED HUMIDISTAT WIRING MAY RESULT IN
IMPROPER OPERATION AND/OR CAUSE DAMAGE TO THE UNIT AND HUMIDISTAT.
电线颜色与接线板终端的颜色必须正确匹配,各终端线路接紧。接错的线路可能导致操作
不正常 和/或 损害机器和湿度调节器。
1)Mount the humidistat on a solid surface away from doors, corners, air outlets or other drafty
or heat generating equipment. Do not mount directly on an outside wall or wall adjacent to a
boiler room.
1) 湿度调节器应安装在坚实的墙壁上,尽量远离门口、角落、送风口、或其它串风的地
方,尽量远离生热设备。不要直接挂载在外墙或毗邻锅炉的房间。
2) Use a piece of foam insulation behind the humidistat to insulate it from the hot or cold
surface. The recommended height is 1.2 metres to 1.5 metres above the floor. The humidistat is
often located next to the thermostat.
2)在湿度调节器后面使用一块泡沫绝缘材料以远离受热或冷的表面。建议离地面高度为
1.2 米至 1.5米。在湿度调节器通常位于恒温器的旁边。
3)For the unit-mounted humidifier, wire the humidifier to the terminal strip on the Wine
Guardian cooling unit using the wire provided. Be sure to match the wire color with the color
code on the terminal strip.
3)、为集成安装的加湿机,用提供的电线将加湿机连接酒卫主机装置侧边的接线板终端。
一定要注意,电线的颜色与接线板终端的色码匹配。
15
Start-Up and Operation 启动和运行
CAUTION
Now that the installation is complete, it’s time to start the unit.
1) Check to make sure all connections are secure.
2) Turn on the cooling unit if so mounted.
3) Turn on the rocker switch on the top of the humidifier.
4) Test the operations by setting the humidistat above the room condition. The humidifier
should come on, the water solenoid should open, and water should flow. It may take a few
minutes for water to appear in the drain line.
5) Set the humidistat below the room condition and the humidifier should shut off.
6) Follow the manufacturer’s directions with the humidistat for troubleshooting.
1) Disregard the wiring diagrams shown within the manufacturer’s instructions. Refer to the
wiring diagram shown in this guide on page 8. The remote outdoor sensor is not required for
wine cellar applications and should not be programmed for use.
2) Set the humidistat at the desired humidity, recommended between 55% and 60%, which is
adequate to prevent drying out of corks and not so high as to risk mold growth. Overhumidifying can cause mold growth and sweating on surfaces and loosening of labels on
bottles.
NOTE: The humidifier can only add moisture, not remove it. Removal, or
dehumidification, is a function of the cooling system as it lowers the temperature of the
air below its dew point at which moisture condenses out onto the cooling coil and into
the condensate drain. Therefore, the humidistat will only control the addition of moisture.
The amount of humidification and dehumidification is mostly dependent on the relative humidity
of the ambient air and on the quality of the insulation and vapor barrier in the cellar. In southern
climates, humidification is not normally the dominant need, just cooling and dehumidification. In
northern, colder climates, winter weather will result in low humidity levels indoors. This requires
more need for humidification to keep the moisture level in the cellar up above 40%, especially in
higher elevations where the air is drier.
BEFORE PERFORMING MAINTENANCE ON THE UNIT, READ AND UNDERSTAND THE SAFETY
INFORMATION CONTAINED IN THIS GUIDE.
维护机器前,请阅读和理解安全指南。
The Wine Guardian Humidifier is designed for minimal maintenance. Never oil any part of the
humidifier. Always disconnect the electrical power to the humidifier and the cooling unit if used.
A regular maintenance program prolongs the life of the humidifier and maintains the humidity in
the cellar. Frequency of cleaning and replacement of the drip pad depends on the inlet water
conditions and the cleanliness of the cellar air. The drain system may also trap dust and dirt.
When water no longer stays on the pad or mineral build-up has started to reduce airflow, the pad
needs to be replaced.
√ Clean the humidifier and replace humidifier pad if needed (see procedures below)
√ Inspect cabinet for corrosion or rusting – clean and paint
√ Check for any loose insulation, fasteners, gaskets or connections
√ Check wiring connections and integrity of cords
√ Check operation of humidifier fan and water solenoid
√ Check to be sure the water supply tube is aimed at the center of the distribution
Cleaning the Humidifier and Replacement of Evaporative Drip Pad
清洁加湿器,蒸发滴灌垫更换
Figure 7.0
警告
BEFORE STARTING WORK, BE SURE THE POWER TO THE WINE GUARDIAN COOLING UNIT AND
HUMIDIFIER ARE TURNED OFF.
MAKE SURE THE POWER CORD IS DISCONNECTED FROM THE POWER SOURCE.
开始工作之前,应确保酒卫冷却装置及加湿机的电源供应处于关闭状态。
确保电源线从电源切开。
1)Start by disconnecting the electrical power and shutting off the water supply.
首先切开电源和供水。
2) Remove the access panel at the back of the humidifier.
拆下在加湿机背面的检修口。
3) Remove the drip pad and its plastic holder from the unit as an assembly by grasping the top
of the holder and pulling toward you, top first. Be sure the water feed tube is clear of the top
distribution tray.
拉分布垫和塑料架是一个组合, 抓紧塑料架顶部拉向你自己,应先拆顶部。要确保分
布托盘顶部不接触滴水管。
20
4) Pull one side of the humidifier pad assembly frame toward you and remove the distribution
tray from the frame.
拉加湿机分布垫装配架一侧,从架上移开分布托盘。
5) Slide the humidifier evaporator pad out of its frame. Clean the frame by twisting and flexing
it to loosen any calcium deposits, or use a putty knife.
分布垫即可滑出塑料架。轻轻扭曲塑料架来松动钙质沉积物,或使用油灰刀清理。
6) Carefully scrape any mineral deposits from the tray and frame. Be sure the frame drain hole
has nothing blocking it. Remove any calcium deposits from the “V” notches in the
distribution tray but do not scrape off the granular coating from the bottom. This textured
surface helps ensure even water flow for maximum performance.
小心地刮去托盘和框架上的任何矿物质。要确保框架上的排水孔没有任何阻挡。取下
“V“形切口在分布盘,注意不要刮除颗粒涂层。这种粗糙表面有助于确保最高性能的水
流量。
7) To clean the drain, pour some hot water mixed with a cleaning solution into the pan to flush
the dirt down the drain tube.
清洁排水,倒入一些热水和清洁剂混合将污垢冲入排水管。
8) Check the humidifier pad. If dirty or excessive mineral deposits are present, install a new
evaporative pad. Replace the pad by sliding the pad back into the frame. Note: the pad must
be installed in the correct position. There is a colored spot painted on one end of the pad.
This is the top of the pad and must be installed with the colored spot UP, next to the
distribution trough. There is no inlet or outlet side for the airflow, only the requirement that
the colored spot be on the top.
Humidifier Water Line Maintenance (See Figure 8.0)
加湿机进水管线维修(见图 8.0)
1) Repeat steps 1 and 2 above.
重复以上 1 和 2 步骤。
2) Disconnect the water line at the inlet to the solenoid valve.
断开电磁阀门的进水口水管。
3) Remove the in-line strainer from inside the inlet fitting by using a small flat-bladed
screwdriver. Do not insert anything into the strainer that a sharp end on it as it might
penetrate the strainer and render it useless.
通过使用一个小的平头螺丝刀从入口装置内部移除内部过滤网。不要插入锋利的物体
进入过滤网,这样做可能穿破过滤网,使其毁坏无法使用。
4) Clean the strainer by flushing under hot water or immersing in a demineralizing solution to
break down the mineral deposits. Inspect and replace the strainer if it cannot be cleaned or if
the screen is damaged 用热水冲洗或将过滤网浸泡于矿物质清除剂中,以除去矿物质沉
积。如果过滤网的矿物质不能被清除,或者屏幕已损坏, 请换新过滤网.
5) Reinstall the strainer in the valve inlet and replace the tubing and tighten the compression
nut. Double wrench to prevent damage and leaks. 将过滤网装入阀门和进水管,拧紧压紧
螺母。双扳手,以防损坏和泄漏。
6) Disconnect the water line on the outlet of the solenoid valve.
断开电磁阀门的出水口水管。
7) Remove the orifice from the copper tube and make sure this small opening is unplugged.
移开铜管内的过滤塞,确保这个小孔没有堵塞。
8) Replace the orifice and reconnect the outlet water line. Double wrench to prevent leaking.
放回过滤塞,并重新连接出水口水管。双扳手,以防漏水。
9) Reinstall the in-line strainer and reconnect the inlet water line. Double wrench to prevent
leaking. 重新安装管内过滤网,然后重新连接进水管。双扳手,以防漏水。
10) Turn on water supply and reconnect electrical power to the humidifier. 打开供水和重新连
接电源至加湿机。
15) Check to be sure the water supply tube is aimed at the center of the distribution tray between
the two center holes. This will ensure even distribution off water across the entire tray and
equally into each of the six holes, thereby evenly wetting the entire surface of the drip pad.
确保供水管瞄准到分布托盘中间的两个中心小孔之间的位置。这将确保水滴均匀分布
在整个分布托盘的 6 个孔里,从而均匀地润湿分布垫的整个表面。
22
Water Line Maintenance Detail 进水管道维修详细
Figure 8.0
23
Directory of Terms 缩写语言索引
Ambient Air – The surrounding area outside the cellar such as a room, basement, garage or
outdoors.
环境空气 - 酒窖外的周围,如一个房间,地下室,车库或室外区域
CLS – Cubic litres per second. A unit of measurement for the amount of air handled by the fan.
CLS-立方升每秒。一种用于空气由风机处理量的测量单位。Condensate / Condensation – The water formed out of the air when it is cooled below a certain
temperature (called dew point). Often referred to as “sweating” on pipes and cold surfaces. This
water collects at the bottom of the evaporator or cooling coil and drains out of the unit through
the drain line.
Condenser (Heat Rejection) Section / Coil – The Condenser Section uses the compressor,
condenser coil and fan to remove heat from the refrigerant to the ambient air outside the wine
cellar. The word condenser refers to the condensation of the refrigerant from gas to liquid phase.
CE– Certificate of European conformity CE-符合欧洲认证
Exhaust Air – The air leaving the evaporator or condenser section of the Wine Guardian unit.
排风 - 空气离开酒卫冷却主机机组蒸发器或冷凝器部分。
Evaporator (Cooling) Section / Coil – The Evaporator Section uses the cooling coil and the
fan to remove heat from the air inside the wine cellar to the refrigerant, cooling the air and
condensing moisture out of the air. The word evaporator refers to the evaporation of the
refrigerant from liquid to gas phase in the coil. The Evaporator Section is connected to or inside
the wine cellar.
Flexible Duct – Round ducts with steel reinforced plastic liners, a layer of insulation and an
outer plastic layer used to convey the air from the unit to the cellar or ambient space.
Grille or Diffuser – Inlet or outlet plates to direct the airflow or protect the inside of the unit.
格栅或扩散片 – 空气进口或出口引导板,或机器的保护板。
Heat Gain / Loss – The amount of cooling or heating expressed in watts transferred
between the wine cellar and the ambient space. The Wine Guardian must offset this load.
热增益/损失 - 酒窖和环境空间的冷却或加热的总额用瓦表示。酒卫系统必须抵消这种
负荷。
Inlet Air – The air entering the evaporator and condenser sections of the Wine
Guardian unit. NEC– National Electrical Code
进气 - 空气进入机组的蒸发器和冷凝器部分。 NEC 公司,美国国家电气规程
Recovery – The amount of cooling the unit does to return the cellar to its set point
temperature after some new load is introduced, such as people or new cases of warm wine
entering the cellar.
恢复 – 增加新的负载后,如进人或暖酒进窖,主机恢复酒窖设定温度所需的制冷量。
Return Air - The air leaving the cellar and returning to the inlet of the evaporator coil. 回风 - 空气离开酒窖并返回到蒸发器盘管的入口。
SP – Static pressure. Unit of measurement (mm of water or pascals of water column) of the
pressure of the air handled by the fan.
警司 - 静态压力。计量单位(水或水柱帕斯卡毫米)的风扇所处理的空气压力。
Set Point – The desired temperature or humidity set on the thermostat or humidistat.
设置点 –在恒温或恒湿设置 所需的温度或湿度。
Supply Air - The air entering the cellar from the discharge of the evaporator coil.
供应空气 - 空气通过蒸发器线圈进入酒窖。
25
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.