Winegard RA-7296 User Manual

set 2 cable as shown in Figure 5. Attach downlead cable to jack on wallplate/amplifier marked antenna as shown in Figure 4. Attach cable going to set 2 outlet to jack on power supply marked SET 2. Attach cable coming from cable input to jack on power supply marked CABLE.
Set 2
Antenna
FIGURE 4
Cable
STEP 6. Mount wall plate/amplifier in wall
with screws provided and attach TV set cable to jack on front. Connect TV set cable to input jack on TV. Press switch on front of outlet and check that light is on.
OFF position. Light on wallplate will go (OFF) showing that power is no longer connected to the amplifier and that both TV sets are receiving signals from outdoor receptacle.
To receive signals from antenna: Press switch to ON position. Light on wallplate will come (ON) showing that power is connected to the amplifier and both TV sets are receiving signals from the antenna.
NOTE: Make sure the antenna is in the operating position (up) and pointed at the station desired.
INSTALLING FC-5910
CONNECTORS ON COAX CABLE
1.
Outer Cover
2.
3.
Crimp Here
Step 1: Strip outer cover back 1/2"* from end of cable. Fray braid back as far as outer cover will allow.
Step 2: Trim braid close to outer cover and remove 1/4"* of inner insulation being careful not to nick center conductor. Make sure no foil or braid can touch center conductor.
Step 3: Slide connector tip between braid and inner insulation (braid and foil, on foil shield cable) and push connector on cable as far as it will go. Crimp built-in ferrule with proper crimping tool. Hex connector requires hex crimping tool. Do Not crush cable out-of-round.
* If installing in very hot weather, increase dimensions 1/8"
WINEGARD MOBILE PRODUCTS LIMITED WARRANTY
Winegard Company warrants this product against defects in materials or workmanship for a period of two (2) years from the date of original purchase. During year one (1) of such warranty, Winegard Company will also pay authorized labor costs to an authorized Winegard dealer to repair or replace defective products. No warranty claim will be honored unless at the time the claim is made, Customer presents proof of purchase to an authorized Winegard dealer (to locate the nearest authorized Winegard dealer, contact Winegard Company, 3000 Kirkwood Street, Burlington, Iowa 52601, Telephone 800-288-8094 or visit www.winegard.com). Customer must provide proof of purchase with a dated sales receipt for the Winegard product to verify the product is under warranty. If the date of purchase cannot be verified, the warranty period shall be considered to begin thirty (30) days after the date of manufacture. If a defect in material or workmanship is discovered, Customer may take the product to an authorized Winegard dealer for service. Customer must provide proof of purchase to verify the product is under warranty. If the product is brought to an authorized Winegard dealer for service prior to expiration of year one (1) of the warranty period and a defect in material or workmanship is verified by Winegard Technical Services, Winegard Company will cover the Winegard dealer’s labor
(2 YEARS PARTS; 1 YEAR LABOR)
1/2" *
Inner Insu lation
¼" *
Center Conduc tor
FIGURE 5
charges for warranty service. The Winegard dealer must contact Winegard Tech­nical Services in advance for pre-approval of the service. Approval of the service is at the sole discretion of Winegard Company. Alternatively, Customer may ship the product prepaid to Winegard Technical Ser­vices (located at 3111 Kirkwood Street, Burlington, Iowa 52601, Telephone 800­788-4417). Customer must return the product along with a brief description of the problem and provide Winegard Technical Services with Customer’s name, ad­dress, and phone number. Customer must also provide proof of purchase to verify the product is under warranty. If the product is returned before the expiration of the warranty period, Winegard Company will (at its option) either repair or replace the product. This Limited Warranty does not apply if the product has been damaged, deterio­rates, malfunctions or fails from: improper installation, misuse, abuse, neglect, ac­cident, tampering, modification of the product as originally manufactured by Winegard in any manner whatsoever, removing or defacing any serial number, usage not in accordance with product instructions or acts of nature such as damage caused by wind, lightning, ice or corrosive environments such as salt spray and acid rain. This Limited Warranty also does not apply if the product becomes unable to perform its’ intended function in any way as a result of the television signal provider making any changes in technology or service.
A Return Material Authorization (RMA) is required prior to returning any product to Winegard Company or Winegard Warranty Services under this warranty policy. Please call our Technical Services Department at 800-788-4417 or send an e-mail to warranty@winegard.com to obtain the RMA number. Please furnish the date of purchase when requesting an RMA number. Enclose the product in a prepaid package and write the RMA number in large, clear letters on the outside of the package. To avoid confusion or misunderstanding, a shipment(s) without an RMA number(s) or an unauthorized return(s) will be refused and returned to Customer freight collect. WINEGARD COMPANY DOES NOT ASSUME ANY LIABILITIES FOR ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, MADE BY ANY OTHER PER­SON. ALL OTHER WARRANTIES WHETHER EXPRESS, IMPLIED OR STATUTO­RY INCLUDING WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY ARE LIMITED TO THE TWO YEAR PERIOD OF THIS WARRANTY. In states that do not allow limitations on implied warranties, or the exclusion of limitation of incidental or consequential damages, the above limitations or exclu­sions do not apply. Some states do not allow limitations on how long an implied warranty lasts, or the exclusion of limitation of incidental or consequential damages, so the above limita­tions or exclusions may not apply to you. This warranty gives Customer specific legal rights. Customer may also have oth­er rights that may vary from state to state.
RETURN AUTHORIZATION POLICY
SATELLITE RECEIVER WARRANTY
See manufacturer’s limited warranty policy.
WS-MOBWARREV2 Rev. 1/10
Printed in U.S.A. 2451489 Rev. 1/10
INSTRUCTIONSSTEP 5. Install connectors on downlead and
MODEL RA-7296
Made in U.S.A.
RV WALL PLATE/
AMPLIFIER
DESCRIPTION
Wall plate/amplifier amplifies VHF/UHF TV signals received by non-amplified Winegard RV antennas with outdoor receptacle for TV set and cable input. Wall plate/amplifier provides a +12 Volt receptacle as well as antenna signals to two TV sets. Cable input from outdoor receptacle connects to wall plate and may be switched so either antenna or cable signals may be watched. See applications. Available in white only.
NOTE: THIS UNIT IS AN AMPLIFIER. USE ONLY WITH NON-AMPLIFIED RV ANTENNAS.
WINEGARD COMPANY
3000 KIRKWOOD ST., BURLINGTON, IA 52601-2000
WARNING: Use this amplifier/ switch with only non-amplified RV antennas.
APPLICATIONS AND
ALTERNATE CONNECTIONS
Non-Amplified Antenna
Cable Input
Antenna Input
Cable Input
Example 1
ON/OFF Switch
Outdoor Receptacle WA-1010
Set 1
WARNING: Do not connect high current devices such as hair dryers to +12 volt receptacle on wall plate/amplifier. Maximum current ratings of this receptacle is 7.5 amps at +12 VDC.
TV Outlet
Set 2
Non-Amplified Antenna
Antenna Input
ON/OFF Switch
Antenna Input
ON/OFF Switch
Set 1
Non-Amplified Antenna
Set 1
Cable Input
Set 2
Example 2
Cable Input
Set 2
Example 3
Outdoor Receptacle WA-1010
TG-7221
Outdoor Receptacle WA-1010
TV Outlet
TV-1030 Splitter
TG-7221
INSTRUCTIONS
STEP 1. Select location for wall plate and
outdoor receptacle. Run two coax cables (RG­59 type) between locations and install connectors on each end. Mark cables so
"cable input" and "TV output" may be identified. Antenna downlead and +12 VDC
will also be needed at inside wall plate/amplifier location.
STEP 2. Refer to outdoor receptacle instruction sheet on how to install cables and receptacle. Make sure jack on outdoor receptacle marked CABLE INPUT is attached to cable going to jack marked CABLE on indoor wall plate/amplifier.
STEP 3. The wall plate/amplifier assembly may be flush mounted in most standard electrical boxes. To flush mount cut a hole in wall to fit the box. Run 2 #12 wires between wall plate/amplifier and +12 VDC source and route downlead cable to this location. Install cable between set 2 outlet and power supply location at this time.
WHEN CONNECTING CABLE OR WIRES
BE SURE SWITCH IS IN OFF POSITION.
STEP 4. Install terminals on wires from +12
VDC source as shown in Figure 1. Crimp terminals with Craftsman type 4 crimping tool or equivalent. See Figure 1. Push wires onto tabs on terminal board as shown in Figure 2. If in doubt as to the polarity of the wires, connect them temporarily to tabs on circuit board and press switch on front of outlet. If light comes on polarity is correct. See Figure 3.
Connector Insulation
FIGURE 1
FIGURE 2
FIGURE 3
Crimp Here
1/4"
Connector Ferrule
#12 Wire
Remove 1/4" of insulation from #12 wire.
+12 VDC
Ground
WARNING
DO NOT connect high current devices such as hair dryers to this receptacle. Maximum current rating of this receptacle is 7.5 amps at 12 VDC.
Loading...