Wine Corner SP40DUPRO Installation & User Manual

INSTALLATION & USER GUIDE
DEFYING
CONVENTION
Wine Cellar Conditioning Unit
SP40DUPRO for Wine Cellars
UIDE D'INSTALLATION ET DUTILISATION WINESP40DUPRO
Page 3
User manual
Table of contents
1.
TECHNICAL DATAS .................................................................................... 6
2. EQUIPMENT ............................................................................................... 8
2.1. Outside unit ............................................................................................ 8
2.2. Inside unit .............................................................................................. 8
2.3. Thermostat ............................................................................................. 8
2.4. Connection box ....................................................................................... 8
2.5. Connection drawing ................................................................................ 8
2.6. Cellar insulation ...................................................................................... 9
2.6.1. Insulation of walls, ceiling and floor ....................................................................... 10
2.6.2. The door ................................................................................................................... 10
2.6.3. Insulation of other elements ................................................................................... 11
3. INSTALLATION OF THE AIR CONDITIONER WINEMASTER® ..................... 12
3.1.List of required material ..........................................................................12
3.2.1. Wall drilling .............................................................................................................. 12
3.2.2. Brackets installation ................................................................................................ 12
3.2.3. Fixing the outside unit ............................................................................................. 12
3.2.4. Air flow .................................................................................................................... 12
3.3.Installation of the inside unit .................................................................. 13
3.4 Ducting connection .................................................................................. 14
3.5 Electric connection .................................................................................. 14
3.5.1 Connection of outside unit ....................................................................................... 14
3.5.2 Connection of inside unit ......................................................................................... 14
3.5.3 Plugging ................................................................................................................... 14
3.5.4 Wiring drawing ........................................................................................................ 15
3.6 Installation of the water drain system .................................................... 16
4. PLUGGING THE AIR CONDITIONER WINEMASTER® ................................. 16
4.1.Connecting the air conditioner ................................................................ 16
4.2.Start up ................................................................................................... 17
4.2.1. Temperature setting ................................................................................................ 17
4.2.2. Standby mode .......................................................................................................... 17
4.2.3. Automatic defrost .................................................................................................... 17
5. MAINTENANCE OF THE AIR CONDITIONER WINEMASTER® ..................... 18
5.1.Filter and outside unit cleaning ............................................................... 18
5.2.Condensates drain ...................................................................................18
6. EXAMPLE OF INSIDE UNIT INSTALLATION .............................................. 19
6.1 Installation above the air conditioned room ............................................19
6.2 Installation beside the air conditioned room ........................................... 19
7. Warranty ................................................................................................. 20
7.1 Legal warranty .......................................................................................... 20
7. 2 years contractual warranty .......................................................................20
7.3 Warranty conditions ................................................................................ 20
7.4 Exclusions and limitations of warranty .................................................... 20
GB
UIDE D'INSTALLATION ET DUTILISATION WINESP40DUPRO
Page 5
Introduction
You purchased an air conditioner WINEMASTER® and we thank you for your confidence.
From conception to marketing, everything
has been implemented to offer an exclusive and high quality product. Brainchild of a team who find in this a motivation to ever satisfy you, we hope that your wine conditioning unit WINEMASTER® will bring you great storage conditions and best wines aging for an incomparable pleasure.
Because the customer is at the heart of all our thoughts, we want to support you in your first steps and lead you towards the best use of your air conditioner every day. Thus, you will find in this manual technical information and practical advice to help you to deal with the essential steps to installation and use.
In order that your wine tasting remains moments to share, FONDIS guarantees you a sincere engagement, dedicated expertise and ongoing follow-up at your service!
FONDIS.
UIDE D'INSTALLATION ET DUTILISATION WINESP40DUPRO
Page 6
1. TECHNICAL DATAS
WINESP40DUPRO
Outside unit Inside unit
Weight of units
35 kg 26 kg
Dimensions H x L x D
408 x 633 x 415 317 x 638 x 546
Temperature setting
Preset at 12°C, adjustable between 4 & 15°C *
Maximum outside temperature.
40°C **
Cooling power
900 W at 15°C **
Electricity supply
230/240V-50 Hz
Cooling power
600 W
Heating power
500 W
Gas
R404A
The circuit breaker must be at least 16 Amps.
* The insulation has to be in accordance with the volume of the cellar and the set temperature.
** The cooling performance is dependant from the outside temperature. Therefore, the set temperature
of 12°C for the cellar cannot be maintained if the outside temperature reaches the 40°C. If the thermal safety functions to often, there is a risk for the compressor to be damaged. In all cases, it must be avoid that the outside temperature remains at 40°C, this high temperature should be limited to the summer period.
VENTILATED COLD OR « NO FROST »
The advantages of « ventilated cold »
:
- No frost other than on the evaporator.
- Automatic defrosting and maximized refrigeration efficiency.
- Cold distribution improved by a permanent air circulation (without air stratification).
The circulation of air allows maintaining the pre-selected temperature throughout the cellar
- .
UIDE D'INSTALLATION ET DUTILISATION WINESP40DUPRO
Page 7
Technical drawing
Outside unit
Inside unit
Thermostat
Wiring brox
UIDE D'INSTALLATION ET DUTILISATION
WINESP40DUPRO
Page 8
2. EQUIPMENT
The air conditioner is composed of 2 separate units, of a thermostat and a wiring box. They must be connected by frigorific ducting pipes and electric connections. The ducting pipes length between both unit should not exceed 20m.
2.1. Outside unit
The unit must be installed outside or in a room.
If the unit is installed outside:
- Place the unit in order the air suction and air rejection are not disturbed
- Encourage the installation in open areas and sheltered from the sun
- Be cautious to the noise to the neighborhood
- Raise the unit to prevent from accumulation of water and snow
If the unit is installed in a room :
- Place the unit in order the air suction and air rejection are not disturbed
- Ensure there is a good ventilation
- Maximum temperature and non permanent 40°C
- Ideal temperature 20°C.
2.2. Inside unit
The inside unit is designed to be installed with a duct system. It has to be placed inside the house
2.3. Thermostat
The thermostat can be installed either inside or outside the air conditioned room. The probe must always be placed in the air conditioned room. The supplied sensor has a length of 1,5m.
It can be extended using insulated flexible cable with 2 conductors of 0.5mm² minimum section.
.
2.4. Connection box
The connection box can be installed too either inside or outside the wine cabinet. If installed outside, take into consideration the cable length ( 2 m)
2.5. Connection drawing
TAKE INTO CONSIDERATION THE CABLE LENGTHS BETWEEN THE
CONNECTION BOX AND THE UNITS
INSIDE UNIT
CABLE LENGTH 2M
OUTSIDE UNIT
NO CABLE SUPPLIED
THERMOSTAT
CABLE LENGTH 2M
MAIN CONNECTION
NO CABLE SUPPLIED
Loading...
+ 12 hidden pages