Windster WIND1024 Installation

Page 1
RA-7730SS RA-7736SS RA-7742SS RA-7748SS
For residential and indoor use only.
Page 2
4
Limited Wa r ranty P.1 5 -P.1 6
WINDSTER recommends that all kitchen range hood
be installed by a certified installer.
Page 3
27” 35”
If the hood is mounted too low, it may caused heat damaged and fire hazard.
Page 4
IMPORTANT SAFETY INSTRUCTIONS WARNING – To reduce the risk of fire, electric shock, or injury to persons, observe
the following: DO NOT spray any liquid form cleaner on hood surface including lights and control switch. To clean the range hood, spray liquid form cleaner directly onto cleaning cloth for hood cleaning.
A. Use this unit onl y in the manner i
Page 5
Page 6
code(s).
- All electrial work have to be done by certified electrician.
- This range hood requires a 120V/60Hz electrical supply and must meet local required safety code(s).
Page 7
Installation and Maintenance must be carried out by qualified installer
Duct cover and extension duct cover fitment may vary depend on the mounting height of the range hood.
5
Install the Upper Mounting Bracket and then adjust the duct to the required height.
.
Ensure the mounted range hood is level when installed for optimum performance. (Fig.4)
NOT
To fit the duct to the top of the chimney, slide the bottom lip under the black plastic plate and then lock into place with the 4 screws provided(Fig. 5)
The chimney duct can be adjust to desired height.
11-3/4"
Fig. 5
Page 8
Fi g . 6 Fi g . 7
Use a level to balance out both sides to ensure the hood will be properly mounted.
Prepare and extend the duct cover to your desired height for mounting.
Mount the unit onto the wall with correct wall screws. (Note different types of walls require different types of screws)
Fi g . 9Fi g . 8
Measure and balance the duct cover bracket at the desired height.
Fi g . 10
Install the aluminum flex hose to the outlet of the hood. (Flex hose not included)
Fi g . 11
Duct cover will come with “teeth” to be installed into the slot on the hood.
6
Page 9
Black plastic plate.
Fi g . 12
Correctly align the duct cover into black
Fi g . 13
plastic plate.
Fi g . 14
Evenly slide duct cover into the slot of the hood.
Fi g . 16 Fi g . 17
Screw in the screws into the bottom duct cover to the hood.
Fi g . 15
Attach duct cover to duct cover bracket and screw in the screws provided.
Completed photo of how the finished installation should look like.
7
Page 10
All figures below are for optional ductless installation. The steps will continue after Figure 9 above.
Fig. 18
Figure 18 (Ductless kit box photo) –Remove the content from box.
Kit will include: Fig. 19 - (1) Recirculation exhaust Fig. 20 - (1) Round collar Fig. 21 - (2) Charcoal filter Fig. 22 - (6) Screws
Fig. 23 Measure and balance the recirculation exhaust and line it up with the exhaust opening in the duct cover.
Fig. 24 Install aluminum flex hose in between the recirculation exhaust and the outlet of the hood.(Flex hose not included)
Fig. 25 Remove grease filters (baffle or aluminum) to expose the motor.
Fig. 19
Fig. 21
Fi g . 23
Fig. 20
Fig. 22
Fi g . 24
Fig. 26 Install covering the white plastic grill and rotate counter-clockwise. Installation complete when it is secured.
Fi g . 25
8
8
Fi g . 26
Page 11
Test the LED lights after putting the LED lights back into original position.
AL700
9
10
3W
AL700
27
Page 12
Problem
Check power plug to see if it is plugged firmly into the power socket.
10
Page 13
28
Range hood should be turn on before cooking to create air pocket. After cooking, range hood should be kept on for additional time until complete ventilation of cooking odor.
9
10
28
11
1111
Page 14
Model: RA-77 Series
Switch
Switch holder
12
Page 15
29
Motor
Yellow
Capacitor
LED LED
Blue
Gray
Red
White
Brown
White
Power
R
Fig. 29 RA-77 Series Electrical Schematic Diagram
White
Black
RA-77 SERIES
See M. DIAGRAMS (Page.14)
3W
LED Driver
Green
160W
13
Page 16
14
Page 17
Limited Warranty
Windster Hoods Inc. warrants this product against defects in material or
workmanship as follows:
1) Labor: For a period of one (1) year from the date of purchase, if this product
is determined to be defective, Windster will repair or replace the product, at its
option, at no charge. After the warranty period, you must pay for all labor
charges. During the “labor” warranty period there will be no c
2) Parts: In addition, Windster will supply, at no charge, new or rebuilt
replacements in exchange for defective parts for a period of two (2) years.
After the warranty period, you must pay for all parts costs. During the “parts”
warranty period, there will be no charge for parts
You must carry-in or mail-in your product during the warranty period. This warranty
only applies to products purch
ased and serviced in the United States or Canada.
What Is Not Covered By These Warranties:
1) Conditions and damages resulting from any of the following:
Improper installation, delivery, or maintenance.
Any repair, modification, alteration or adjustment not authorized by the
manufacturer or an authorized service dealers.
Misuse, abuse, accidents, or unreasonable use.
Incorrect electric current, voltage or supply.
Improper setting of any control.
Improper chemical cleaning.
2) Light Bulbs
3) Products purchased for commercial or industrial use (such as in a hotel, office,
restaurant, or other business)
4) Damage due to earthquake, flood, storm, etc.
harge for labor.
15
Page 18
Defective Products:
.
All products will be inspected, tested, and carefully packed by the manufacturer
before shipping to customers. Products that are damaged during transit can only be
exchanged for the same product, under the condition that the customer must get a
RMA (Return Merchandise Authorization) from Windster. When products are
received defective, you must notify us within the 3 business days of receiving the
package. Replacement products are only shipped when the RMA is issued. NO
EXCEPTIONS.
Return Policy
Windster offers only the best and highest quality products. If you are not satisfied
with your purchase, please contact us within 3 business days of product arrival to
obtain a Return Merchandise Authorization (RMA). Returns sent without a RMA will
not be accepted. There will be a 25% re-stocking fee for every returned items.
Shipping fee will also be deducted from the original purchase price. When returning a
package, please include a copy of your purchase receipt. Use the original shipping
box and packing materials and completely remove or cover the original shipping label
Make sure that products are in brand new condition, uninstalled, un-drilled, and
contain everything that came with the package as when you first received it. If any
parts or manuals are missing, we have the right not to accept the return.
16
Page 19
5101 Commerce Drive
Baldwin Park, CA 91706
TEL: (626)962-8600
FAX: (626)962-8669
Loading...