The Chariot Scrubber is a battery powered, stand-on, hard floor scrubber intended for commercial use. The
appliance applies a cleaning solution onto a hard floor, scrubs the floor with brush or pad, and then vacuums the
soiled water back into the recovery tank.
Warranty Registration
Thank you for purchasing a Windsor product. Warranty registration is quick and easy.
Your registration will allow us to serve you better over the lifetime of the product.
The HOW TO USE THIS MANUAL section will tell you
how to find important information for ordering correct
repair parts.
Parts may be ordered from authorized Windsor
dealers. When placing an order for parts, the machine
model and machine serial number are important. Refer
to the MACHINE DATA box which is filled out during the
installation of your machine. The MACHINE DATA box
is located on the inside of the front cover of this manual.
The model and serial number of your machine are
located below the battery compartment of the machine.
The SAFETY section contains important information
regarding hazard or unsafe practices of the machine.
Levels of hazards are identified that could
result in product or personal injury, or severe injury
resulting in death.
The OPERATIONS section is to familiarize the operator
with the operation and function of the machine.
The MAINTENANCE section contains preventive maintenance to keep the machine and its components in
good working condition. They are listed in this general
order:
•Batteries
•Scrub Brush
•Squeegee
•Service Schedule
•Machine Troubleshooting
The PARTS LIST section contains assembled parts
illustrations and corresponding parts list. The parts lists
include a number of columns of information:
REF - column refers to the reference number on
the parts illustration.
PART NO. - column lists the part number for the
part.
PRV NO. - Reference No.
QTY - column lists the quantity of the part used in
that area of the machine.
DESCRIPTION - column is a brief description of
the part.
SERIAL NO. FROM - If this column has an (*) and
a Reference number, see the SERIAL NUMBERS
page in the back of your manual. If column has two
asterisk (**), call manufacturer for serial number.
The serial number indicates the first machine the
part number is applicable to. The main illustration
shows the most current design of the machine.
When a boxed illustration is shown, it displays the
older design.
NOTES - column for information not noted by the
other columns.
4
NOTE: If a service or option kit is installed on your
machine, be sure to keep the KIT INSTRUCTIONS
which came with the kit. It contains replacement parts
numbers needed for ordering future parts.
The number on the lower left corner of the front cover is
the part number for this manual.
86333220 CS20
Safety
IMPORTANT SAFETY INSTRUCTIONS
When using an battery powered appliance, basic precaution
must always be followed, including the following:
READ ALL INSTRUCTIONS BEFORE USING THIS MACHINE.
To reduce the risk of fire, electric shock, or injury:
Use only indoors. Do not use outdoors or expose to rain.
Use only as described in this manual. Use only manufacturer's recommended components and attachments.
If the machine is not working properly, has been dropped, damaged, left outdoors, or dropped into water, return it to
an authorized service center.
Do not operate the machine with any openings blocked. Keep openings free of debris that may reduce airflow.
This machine is not suitable for picking up hazardous dust.
Machine can cause a fire when operating near flammable vapors or materials. Do not operate this machine near
flammable fluids, dust or vapors.
This machine is suitable for commercial use, for example in hotels, schools, hospitals, factories, shops and offices
for more than normal housekeeping purposes.
Maintenance and repairs must be done by qualified personnel.
If foam or liquid comes out of machine, switch off immediately.
Disconnect battery before cleaning or servicing.
Before the machine is discarded, the batteries must be removed and properly disposed of.
Make sure all warning and caution labels are legible and properly attached to the machine.
During operation, attention shall be paid to other persons, especially children.
Before use all covers and doors shall be put in the positions specified in the instructions.
When leaving unattended, secure against unintentional movement.
The machine shall only be operated by instructed and authorized persons.
When leaving unattended, switch off or lock the main power switch to prevent unauthorized use.
Only chemicals recommended by the manufacturer shall be used.
This appliance has been designed for use with the brushes specified by the manufacturer. The fitting of other
brushes may affect its safety.
Do not use on surfaces having a gradient of over 10% (6 degrees).
SAVE THESE INSTRUCTIONS
86333220 CS20
5
Safety
MESURES DE SÉCURITÉ IMPORTANTES
Lors de l'utilisation d'un appareil à batteries, il est nécessaire de respecter systématiquement des mesures de
sécurité de base, comme suit :
PRENEZ NOTE DE TOUTES CES MESURES AVANT D'UTILISER CETTE
MACHINE.
Pour réduire les risques d'incendie, de chocs électriques, ou de blessures :
N'utiliser cette machine qu'en intérieur. Ne jamais l'utiliser à l'extérieur ou dans la pluie.
N'utiliser cette machine que comme décrit dans le présent manuel. N'utiliser que les composants et les accessoires
conseillés par le fabricant.
Lorsque la machine ne fonctionnant pas correctement, a fait l'objet d'une chute ou d'une détérioration, a été laissée
à l'extérieur, est tombée dans l'eau, la retourner au centre de service agréé.
Ne pas opérer la machine lorsque les conduits de ventilation sont bloquées. Débarrasser les débris des conduits,
car ils peuvent réduire l'écoulement d'air.
Cette machine n'est pas adaptée au ramassage de poussières dangereuses
Cette machine peut provoquer un incendie lorsqu'elle est utilisée près de vapeurs ou de matériaux inflammables.
Ne pas l'utiliser près de liquides, de poussières ou de vapeurs inflammables.
Cette machine est destinée à un usage commercial. Elle est recommandée davantage pour les domaines hôtelier,
scolaire, hospitalier, industriel ou pour les bureaux, les chaînes de magasin, que pour un usage domestique
normal.
L'entretien et les réparations de la machine doivent être effectuées par un personnel qualifié.
Si de la mousse ou du liquide sort de la machine, la mettre hors tension immédiatement.
Déconnecter les batteries avant de nettoyer la machine ou de la soumettre à un entretien.
Avant de se débarrasser de la machine, il est nécessaire de retirer les batteries et de les jeter correctement.
S'assurer que toutes les plaques d'avertissement ou de précaution sont lisibles et fixées correctement sur la
machine.
Durant la manoeuvre de la machine, prendre garde aux personnes environnantes et notamment aux enfants.
Avant l'utilisation de la machine, veiller à positionner tous les couvercles et portes comme indiqué dans les instructions.
Lorsque la machine est laissée sans surveillance, s'assurer qu'elle ne se déplace pas de manière accidentelle.
Cette machine ne doit être manoeuvrée que par un personnel expérimenté et qualifié.
Lorsque la machine est laissée sans surveillance, la mettre hors tension ou verrouiller l'interrupteur principal afin
d'empêcher un emploi non autorisé.
Seuls les produits chimiques recommandés par le fabricant doivent être utilisés.
Cette machine a été conçue pour être utilisée avec des brosses spécifiées par le fabricant.
L'utilisation d'autres brosses peut affecter sa sûreté.
N'employez pas sur des surfaces ayant un gradient de plus de 10% (6 degrés).
CONSERVER CES INSTRUCTIONS
6
86333220 CS20
Safety
The following symbols are used throughout this guide as indicated in their descriptions:
HAZARD INTENSITY LEVEL
There are three levels of hazard intensity identified by signal words -WARNING and CAUTION and FOR SAFETY.
The level of hazard intensity is determined by the following definitions:
WARNING - Hazards or unsafe practices which COULD result in severe personal injury or death.
CAUTION - Hazards or unsafe practices which could result in minor personal injury or product or property damage.
FOR SAFETY: To Identify actions which must be followed for safe operation of equipment.
Report machine damage or faulty operation immediately. Do not use the machine if it is not in proper operating
condition. Following is information that signals some potentially dangerous conditions to the operator or the equipment. Read this information carefully. Know when these conditions can exist. Locate all safety devices on the
machine. Please take the necessary steps to train the machine operating personnel.
FOR SAFETY:
DO NOT OPERATE MACHINE:
Unless Trained and Authorized.
Unless Operation Guide is Read and understood.
In Flammable or Explosive areas.
In areas with possible falling objects.
WHEN SERVICING MACHINE:
Avoid moving parts. Do not wear loose clothing; jackets, shirts, or sleeves when working on the machine. Use
Windsor approved replacement parts.
Batteries emit hydrogen gas. Explosion or fire can result. Keep sparks and open flame away. Keep solution
tank in raised position when charging. Keep sparks and flames away from the batteries. Do not smoke
around batteries.
Disconnect batteries before working on machine. Only qualified personnel should work inside machine.
Always wear eye protection and protective clothing when working on or near batteries. Avoid skin contact
with the acid contained in the batteries.
Never allow metal to lie across battery tops.
86333220 CS20
7
Safety
Les symboles ci-dessous sont utilisés à travers ce manuel comme illustré dans leurs descriptions :
DEGRÉS DE RISQUES EN CAS DE DANGER
Il existe trois degrés de risques identifiés par les termes signalétiques -AVERTISSEMENT et ATTENTION et POUR
VOTRE SÉCURITÉ. Le degré de risque est défini de la manière suivante:
AVERTISSEMENT - Dangers ou méthodes dangereuses qui POURRAIENT provoquer de graves blessures ou
entraîner la mort.
ATTENTION - Dangers ou méthodes dangereuses qui pourraient provoquer des blessures légères ou une détérioration du produit ou des biens immobiliers.
POUR VOTRE SÉCURITÉ: ce signe permet d'identifier les mesures de précaution à prendre pour assurer un bon
fonctionnement du matériel.
Rendre compte immédiatement d'une défaillance ou d'une détérioration de la machine. Ne pas utiliser la machine
si celle-ci ne fonctionne pas correctement. Lire soigneusement les informations ci-dessous signalant certains
dangers potentiels pour l'opérateur de la machine. L'opérateur doit être absolument au courant de ces dangers
potentiels. Localiser tous les dispositifs de sécurité sur la machine. Il est conseillé de prendre les mesures nécessaires pour former le personnel opérateur.
POUR VOTRE SÉCURITÉ:
NE PAS MANOEUVRER LA MACHINE:
Lorsqu'on n'est pas expérimenté ou qualifié.
Lorsque le guide d'utilisation n'est pas été lu ou compris.
Dans des zones inflammables ou explosives.
Dans des zones où des objets peuvent tomber.
LORS DE L'ENTRETIEN DE LA MACHINE:
Éviter les parties amovibles. Ne pas porter de vêtements amples, tels que des vestes, des chemises ou des
vêtements avec manches lors de l'utilisation de la machine. Utiliser les pièces détachées Windsor homologuées.
Les batteries émettent le gaz d'hydrogène. L'explosion ou le feu peut résulter. Étincelles de subsistance et
flamme nue loin. Compartiment de batterie de subsistance ouvert en chargeant. Étincelles et flammes de
subsistance loin des batteries. Ne fumez pas autour des batteries.
Déconnecter les batteries avant de travailler sur la machine. La machine ne doit être confiée qu'à un
personnel qualifié. Porter systématiquement des lunettes et des vêtements de protection lors d'une intervention sur les batteries ou aux alentours. Éviter tout contact de la peau avec l'acide contenu dans les
batteries.
Ne jamais placer d'objets métalliques sur le dessus des batteries.
886333220 CS20
Safety
CAUTION
BATTERY
CAUTION LABEL
86335010 (2X)
CAUTION
CAUTION LABEL
86244310
PRV NO. 500956
WARNING LABEL
86244300
86252520
PRV NO. 80885
PRV NO. 500955
SAFETY LABEL LOCATIONS
These drawings indicate the location of safety labels on the machine. If at any time the labels become illegible,
promptly replace them.
EMPLACEMENT DE L'ÉTIQUETTE DE SÉCURITÉ
REMARQUE : Ces dessins indiquent l'emplacement des étiquettes de sécurité sur la machine. Si, à tout moment,
les étiquettes deviennent illisibles, contactez votre représentant autorisé pour un remplacement
rapide.
86333220 CS209
Operations
Technical Specifications
ITEMDIMENSION/CAPACITY
Nominal Power-Disk1080 W
Nominal Power-Cylindrical1512 W
Rated Voltage36 Volts DC
Rated Amperage -Disk30 amps
Rated Amperage -Cylindrical42 amps
Batteries3 X12 Volt 130 AH @ 20 hr. rate
Battery Compartment Dimensions20-1/2 in. x 13 in. x 10 in. tall (330mm x 521mm x 254mm)
Scrub Brush Motor - Disk Machine1 x .28 HP (209 W)
Scrub Brush Motor - Cylindrical Machine1 x .8 HP (600 W)
Vacuum Motor.63 HP (470 W)
Maximum flow rate of vacuum motor72 cfm (33.98 liters per second)
Maximum suction of vacuum motor47.3 inches of water (11.7 kPa)
Propelling Motor.21 HP (157 W)
Mass (GVW)726 lbs (330 kg)
Weight empty without batteries - Disk209 lbs (96 kg)
Weight empty without batteries - Cylindrical 255 lbs (116 kg)
Solution ControlGravity, 1/3 GPM average
Solution capacity10 gal (38 L)
Recovery capacity10 gal (38 L)
Scrub brush diameter - Disk20 inch (508 mm)
Scrub brush length - Cylindrical 22 inch (559 mm)
Scrub brush pressure - Disk 50 lbs (222N)
Scrub brush pressure - Cylindrical 46 lbs (21 kg)
Scrub brush speed - Disk180 rpm
Scrub brush speed - Cylindrical1500 rpm
Tires8 in. (203mm) drive, 6 in. (156mm) rear, polyurethane
Maximum Speed2.7 mph (4.3 Km/hour)
BrakeElectrical parking brake,sets automatically whenever operator stops.
Minimum aisle u-turn width51in. (1295 mm)
Maximum rated climb and descent angle10% (6 degrees)
Vibration, hands - Disk1.6 m/s²
Vibration, feet - Disk0.54 m/s²
Uncertainty - Disk 0.5 m/s²
Sound pressure level - Disk68.0 dBA
Sound power level - Disk81.1 dBA
Uncertainty - Disk 3.0 dBA
Vibration, hands - Cylindrical1.5 m/s²
Vibration, feet - Cylindrical0.9 m/s²
Uncertainty - Cylindrical0.5 m/s²
Sound pressure level - Cylindrical71.5 dBA
Sound pressure level - Cylindrical84.7 dBA
Uncertainty - Cylindrical3.0 dBA
1086333220 CS20
ITEMMEASURE
WIDTHLENGTH
HEIGHT
Height 51.8 in (1316mm)
Length 44.0 in (1118mm)
Width without squeegee - Disk23.4 in (594mm)
Width without squeegee - Cylindrical25.4 in (645mm)
Width of squeegee - Disk27.2 in (691mm)
Width of squeegee - Cylindrical29.3 in (744mm)
Width of scrub path - Disk20 in (508mm)
Width of scrub path - Cylindrical22 in (559mm)
Operations
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction
concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure
that they do not play with the appliance.
Cet appareil n'est pas prévu à l'usage des personnes (enfants y compris) avec des possibilités physiques, sensorielles ou mentales réduites, ou le manque d'expérience et de connaissance, à moins qu'ils aient été donnés la
surveillance ou l'instruction au sujet de l'utilisation de l'appareil par une personne chargée de leur sûreté. Des
enfants devraient être dirigés pour s'assurer qu'ils ne jouent pas avec l'appareil.
86333220 CS2011
Operations
How This Machine Works
The Chariot® is a battery powered, self-propelled, hard
floor scrubber intended for commercial use. The
appliance applies a cleaning solution onto a hard floor,
scrubs the floor with a brush, and then vacuums the
soiled water back into the recovery tank.
The machine's primary systems are the solution
system, scrub system, recovery system, and operator
control system.
The function of the solution system is to store cleaning
solution and deliver it to the scrub system. The solution
system consists of the solution tank, strainer, metering
valve and solenoid valve. The solution tank stores
cleaning solution (water and detergent) until it is
delivered to the scrub system. The strainer protects the
valves from debris. The solenoid valve automatically
prevents solution flow unless the scrub brush is turned
on and the machine is being propelled.
The function of the scrub system is to scrub the floor.
The disk scrub system consists of one rotary type disk
scrub brush, motor, scrub deck skirt and lift actuator.
The brush scrubs the floor as the motor drives the
brush. The brush drive hub allows the scrub brush to
follow irregularities and changes in the floor without
loosing contact with the floor. The scrub deck skirt
controls the cleaning solution on the floor so that the
squeegee can pick it up.
The function of the recovery system is to vacuum the
soiled water back into the recovery tank. The recovery
system consists of the squeegee, vacuum motor, float
ball, recovery tank. The squeegee wipes the dirty
solution off the floor as the machine moves forward.
The vacuum motor provides suction to draw the dirty
solution off the floor and into the recovery tank. The
float ball filter protects the vacuum fan from debris and
foam. The recovery tank stores the dirty solution.
The function of the operator control system is to control
the direction and speed of the machine. The directional
control system consists of the direction control drive
reset switch, throttle pedal, emergency stop/brake
switch, steering wheel, propel controller, and drive
wheel. The directional control drive reset switch signals
forward or reverse direction and makes sure the
operator is on the platform before machine will propel.
The controller interprets signals from the throttle pedal
to command the drive wheel to propel or slow the
machine. The steering wheel points the drive wheel in
the direction desired by the operator. The parking brake
automatically engages when the operator stop the
machine. The emergency stop/brake can be used to
hold the machine on slopes.
The cylindrical scrub system consists of two cylindrical
brushes, motor, side squeegees, and lift actuator. The
two counter rotating brushes scrub the floor, driven by a
single motor. The brush deck “floats” with constant
brush pressure. The side squeegees keep the cleaning
solution within the brush deck width, allowing the main
squeegee to pick the solution up.
1286333220 CS20
Operations
Cylindrical
Deluxe Disk & Cylindrical
12
1
2
3
4
5
6
7
8
9
11
10
9
10
12
Components
1. Drive Control
2. Scrub Controls
3. Control Console
4. Pedal Platform
5. Solution Tank
6. Recovery Tank
7. Recovery Sight Dome
8. Recovery Drain Hose
9. Scrub Deck Skirt
10. Solution Cover
11. Solution Drain Hose/Solution Level Indicator
12. Squeegee
86333220 CS2013
Operations
1
2
3
4
5
6
7
89
10
Drive Controls
1486333220 CS20
Operations
1. KEY SWITCH
Controls the power for machine functions.
To turn the machine power on, rotate key clockwise.
To turn the machine off, rotate key counterclockwise.
When the key is turned on the battery symbol will flash once and stay on continuously.
2. EMERGENCY STOP/BRAKE SWITCH
This safety feature is designed to cut all power to the machine at any time and apply parking brake.
To shut the machine power off, push the Emergency Stop Switch, this will also engage the parking brake and
cause the machine to stop immediately.
To reset the machine, rotate the switch clockwise.
3. DIRECTIONAL CONTROL / DRIVE RESET SWITCH
This safety feature is designed to ensure safe engagement of propel drive. Each time the machine power is
turned on, or each time an operator steps on to the platform, the Drive Reset Switch must be pushed before
machine will propel.
The switch controls the direction of travel of the vehicle. The lighted arrow on the switch indicates direction of
travel.
To travel forward, press the top of the switch.
To travel in reverse, press the bottom of the switch.
1. Key Switch
2. Emergency Stop/Brake Switch
3. Directional Control / Drive Reset Switch
4. Throttle Pedal
5. Horn Button
6. Steering Wheel
7. Speed Control
8. Battery Discharge Indicator
9. Hour Meter
10. Operator Presence Switch
86333220 CS2015
Operations
SLOW
FAST
4. THROTTLE PEDAL
Controls the speed of the vehicle within the speed control setting selected. Pressing the pedal causes the
machine to travel in the direction selected by the Directional Control Switch.
To increase speed, increase pressure on the pedal.
To decrease speed, decrease pressure on the pedal.
5. HORN BUTTON
The horn is activated by pressing the horn button.
6. STEERING WHEEL
The steering wheel turns the front wheel causing the machine to change direction.
7. SPEED CONTROL
Controls the maximum speed of the machine. There are two settings, slow and fast.
To change speed, rotate the dial to either slow or fast position. The slow position is to the left (counterclockwise), fast to the right (top position).
The throttle pedal will always regulate the speed between 0 and maximum
1686333220 CS20
Operations
8. BATTERY DISCHARGE INDICATOR
Indicates the charge level of the batteries.
The indicator will be illuminated if the batteries have a sufficient charge. A slow, continuous flash indicates the
batteries require charging.
The Battery Lockout function will activate when the batteries are low.
Once active, the LED status indicator will begin to flash slowly and the controller will inhibit the scrub motor and
water solenoid. The vacuum and drive remain functional. The “vacuum only” selection (position ‘B’) can be
used to vacuum up any remaining water. Return the unit to the charging station and charge the batteries.
NOTE: Continuing usage may damage the batteries.
When the machine is left overnight with less than a full charge, the display may initially indicate a full charge. It
will also indicate a full charge if the batteries are disconnected, then reconnected. After a few minutes of
operation the indicator will give the correct charge level.
9. HOUR METER
Records the number of hours the machine has been in scrubbing operation. This information is useful in determining when to service the machine.
86333220 CS2017
Operations
1
Scrub Controls
1. FUNCTION MODE SWITCH
The first two positions are for transport only. See drive controls section.
A1 - Light cleaning
This mode is used for light cleaning. In this mode the machine will propel at fast speed. The ‘floating’ scrub
deck and squeegee is in the down position. The water will flow. Water will automatically shut off in neutral and
restarts when scrubbing is resumed. The vacuum will draw the water into the recovery tank.
A2 - Deep cleaning
This mode is used for deep cleaning. In this mode the machine will propel at a low speed. The ‘floating’ scrub
deck and squeegee is in the down position. The water will flow. Water will automatically shut off in neutral and
restarts when scrubbing is resumed. The vacuum will draw the water into the recovery tank.
1886333220 CS20
Operations
B - Vacuum only mode
This mode is used for picking up solution only. The brush and water will both be up and off. In this mode the
machine will propel at fast speed. The squeegee is lowered and the vacuum will come on.
C - Double Scrub cleaning
This mode is used for putting down solution and scrubbing without picking it back up. The squeegee is set
manually by connecting the two double scrub support cables. In this mode the machine will propel at a slow
speed. The scrub deck will lower. The solution will flow. The brush and water will shut off when the machine is
in neutral. They will resume when propelling is resumed.
86333220 CS2019
Operations
1
2
3
5
4
DISK
Scrub Controls-Squeegee
1. Squeegee Latch
2. Squeegee Hose and Tube
3. Squeegee Wheels (3)
4. Double Scrub Support Cable
5. Double Scrub Cable Hook
2086333220 CS20
Operations
4
CYLINDRICAL
1
3
2
5
1. Squeegee Latch
The squeegee latch holds the squeegee in place.
2. Squeegee Hose and Tube
The squeegee hose and tube carry the recovered solution to the recovery tank.
3. Squeegee Wheels
The three squeegee wheels support the squeegee at the correct height and angle so that no adjustment is
required.
4. Double Scrub Support Cable
The double scrub support cables retain the deck in the double scrub position.
5. Double Scrub Cable Hook
The double scrub cable hook is the connection point for the double scrub support cable.
Since the squeegee is raised and lowered by the scrub deck, the double scrub position is set manually.
86333220 CS2021
Operations
FILL PORT
WITH SCREW CAP
Machine Operation
Pre-Run Machine Inspection
Do a pre-run inspection to find possible problems that
could cause poor performance or lost time from breakdown. Follow the same procedure each time to avoid
missing steps.
NOTE: See maintenance section for pre-run machine
inspection checklist items.
Starting Machine
NOTE: Perform pre-run machine check before
operating machine.
FOR SAFETY: Before starting machine, make sure
that all safety devices are in place and operating
properly.
1. The operator should be on the pedal platform. The
throttle pedal must be in the neutral position.
2. Turn the machine power on by turning key switch
clockwise to the “ON” position.
3. Press the Drive Reset Directional Control Switch to
reset and set the intended direction for travel.
4. Press lightly on the throttle pedal with right foot
4. .Measure the chemical into the solution tank. Liquid chemicals should be added to the solution tank
after filling with water. Dry chemicals should be
thoroughly mixed before being added into solution
tank. Commercially available, high alkaline floor
cleaners, are suitable for use in the solution system.
NOTE: Read the chemical manufacturers
recommended proportion instructions.
5. Close console and latch rear cover.
Flammable materials can cause an explosion or
fire. Do not use flammable materials in the tanks.
Les matières inflammables peuvent provoquer une
explosion ou un incendie. Ne pas utiliser de
matériaux inflammables dans les réservoirs.
Filling Solution Tank (Deluxe)
FOR SAFETY: Before leaving or servicing machine;
stop on level surface, turn off machine and remove
key.
Emergency Stop Procedure
Push in emergency stop button. This will also engage
the parking brake and cause the machine to stop immediately.
Filling Solution Tank
FOR SAFETY: Before leaving or servicing machine;
stop on level surface, turn off machine and remove
key.
1. Turn the machine power off.
2. Tilt co
3. nsole forward. Push left or right fill port cover
down.Fill the solution tank with clean water, leaving
enough room for the required amount of cleaning
solution. The solution tank capacity filled to fill inlet
is 10 gallons (38 liters). The water must not be hotter than 140° F (60°C) to prevent damage to the
tank
1. Turn the machine power off.
2. Using fill port, fill the solution tank with clean water,
leaving enough room for the required amount of
cleaning solution. The solution tank capacity filled
to fill inlet is 10 gallons (38 liters). The water must
not be hotter than 140° F (60°C) to prevent
damage to the tank.
2286333220 CS20
Operations
3. Measure the chemical into the solution tank. Liquid
chemicals should be added to the solution tank
after filling with water. Dry chemicals should be
thoroughly mixed before being added into solution
tank. Commercially available, high alkaline floor
cleaners, are suitable for use in the solution system.
Normal Scrubbing
Plan the scrubbing pattern in advance. The longest
track is around the perimeter of the area to be cleaned.
For efficient operation, the runs should be the longest
possible without turning, stopping, or raising or
lowering scrub deck/squeegee.
In order to achieve the best possible results, the area
which is to be cleaned should be swept before scrubbing. Large debris, strings and wire must be removed to
prevent being caught in brushes or squeegee.
If the machine is allowed to stand in neutral with the
scrub deck down, the solutions flow stops and brush
motor stops. If either forward or reverse travel is
selected, the solution flow will continue in the same
setting and the scrub brush motor will continue once
movement of machine begins. Overlap the brush path
and avoid transporting over previously cleaned areas.
To Begin Scrubbing
When operating the machine around people, pay
close attention for unexpected movement. Use
extra caution around children.
Lorsque vous utilisez la machine en présence de
gens, portez une attention particulière aux mouvements inattendus. Soyez plus prudent, surtout en
présence d’enfants.
Flammable liquids and/or reactive metals can
cause explosions or fire! Do not pick up.
Les liquides inflammables et / ou les métaux
réactifs peuvent provoquer des explosions ou un
incendie ! Ne les ramassez pas.
1. Stand on the operator platform. Throttle pedal must
be in neutral position.
2. Turn machine power on.
3. Press the Drive Reset / Directional Control Switch,
selecting the desired travel direction.
4. Position the function control knob to the desired
operation. The scrub deck and squeegee will
lower, and the vacuum will turn on.
5. Drive machine forward to begin scrubbing.The
scrub brush motor will run and solution will flow
when the throttle is depressed.
NOTE: Shut machine off immediately if water or foam
is expelled from the machine. Solution flow is
automatically shut off when brush motor stops. When
brush motor is activated, flow automatically resumes.
86333220 CS2023
Operations
CABLE
DOUBLE SCRUB HOOK
DOUBLE SCRUB
DOUBLE SCRUB
CABLE
DOUBLE SCRUB
HOOK
To Stop Scrubbing
1. Rotate the function knob to either transport position. The brush motor and vacuum will stop and the
scrub deck will rise to the park position.
2. Allow the throttle pedal to return to neutral.
3. Turn machine power off.
NOTE: FOR SAFETY: Before leaving or servicing
machine: stop on level surface, turn off machine
and remove key.
Double Scrub
Floors which are heavily soiled or have thick accumulations of floor finish may not clean sufficiently with one
pass. In these cases it will be necessary to double
scrub.
Connect the Double Scrub Cables to the squeegee.
Rotate the knob to the double scrub position.
To support the squeegee off the floor for double scrub,
pull the support cables down, one side at a time, and
connect to the hook on the squeegee while lifting and
tilting the squeegee upward.
Cylindrical Machine
NOTE: The deck and squeegee must be in the up
position to hook the cables.
To collect the solution and complete the Double Scrub
operation, release both squeegee cable and turn the
function knob to one of the normal scrubbing modes.
Disk Machine
2486333220 CS20
Operations
RECOVERY
DRAIN HOSE
DRAIN HOSE
SOLUTION
STORAGE POSITION
Emptying and Cleaning Tanks
1. Park the machine next to a floor drain. Drain hoses
are at the rear of the machine.
2. Turn the machine power off.
Recovery Tank
1. Pull the recovery drain hose from the mounting
pocket. Lift cap, pinch hose then lower hose in
direction of the drain. Do not stand in front of end of
hose. Recovered solution will come out with force.
2. To flush the recovery tank, lift the control console to
access the recovery tank. Do not use water hotter
than 140°F (60°C) to clean tank. Damage may
occur.
3. Clean debris from sight dome and cover surface.
4. Clean off the float shut-off screen and inspect for
free movement of float.
5. Replace the drain cap and secure drain hose.
6. If machine is to be stored, tilt the recovery tank
back and prop the console up, partially opening
each.
Solution Tank
1. Pull the solution drain hose from its mounting
pocket. Lower hose in direction of drain.
2. Open the control console.
3. Flush the solution tank out with clean water and
run several gallons of clean water through systems. Do not use water hotter than 140°F (60°C) to
clean tank. Damage may occur.
NOTE: Never allow solution to remain in tank.
Damage to tank, seals and valves could occur.
86333220 CS2025
Maintenance
Service Schedule
MAINTENANCE
Check water level of batteries after charging; add
distilled water if necessary. (Wet cell only)
Visually check for damaged or worn tires.*
Check brush or pad for proper installation.*
Check vacuum hose connections.*
Check that squeegee is securely attached.*
Check for securely attached drain hoses, plug and cap.*
Check pedal, brake and steering for proper operation.*
Clean out recovery tank.*
Clean and inspect float shutoff.*
Clean out solution tank.*
Clean and inspect solution filter strainer.*
Run vacuum motor to dry.*
Clean brush or pad and check wear.*
Clean squeegee blades and check wear.*
Clean outside of tanks, check for damage.*
Store with console cover propped open.*
Charge batteries if needed.*
Clean off top of batteries.*
Check battery cells with hydrometer. (Wet cell only)*
Inspect scrub deck skirt.*
Clean solution strainer inside tank.*
Check battery connections are tight.*
Clean battery cases and battery compartment.*
Check parking brake.*
Clean pivot points on squeegee and scrub deck.*
Check all motors for carbon brush wear.*
Check motor commutators.*
Check steering chain tension.*
Check drive chain tension.*
BEFORE EACH
WORK PERIOD
*
AFTER EACH
WORK PERIOD
50
HRS
100
HRS
200
HRS
2686333220 CS20
Maintenance
1
3
4
5
2
Batteries
1. Cover Retainer Latch
2. Rear Cover
3. Battery Connector-Machine
4. Batteries
5. Battery Tray
86333220 CS2027
Maintenance
Batteries (Wet Cell)
The batteries provide the power to operate the
machine. The batteries require regular maintenance to
keep them operating at peak efficiency.
The machine batteries will hold their charge for long
periods of time, but they can only be charged a certain
number of times. To get the greatest life from the
batteries, charge them when their charge level reaches
25% of a full charge. Use a hydrometer to check the
charge level.
Do not allow the batteries to remain in a discharged
condition for any length of time. Never expose a
discharged battery to temperatures below freezing.
Discharged batteries will freeze causing cracked
cases. Do not operate the machine if the batteries are
in poor condition or if they have a charge level below
25% (specific gravity below 1.155).
Keep all metallic objects off the top of the batteries, as
they may cause a short circuit. Replace worn or
damaged cables and terminals.
Check the electrolyte level in each battery cell before
and after charging the batteries. Never add acid to the
batteries, use distilled water. Do not allow water level to
fall below the battery plates. Portions of plates exposed
to air will be destroyed. Do not overfill. Keep plugs
firmly in place at all times.
Not all batteries require maintenance. AGM
batteries are maintenance free. Do not attempt to
remove sealed caps from AGM batteries. Warranty
is void if caps are removed from AGM battery.
L’entretien n’est pas nécessaire pour toutes les
batteries. Les batteries AGM ne nécessitent pas
d’entretien. N'essayez pas d'enlever les bouchons
scellés des batteries AGM. La garantie est annulée
si les bouchons sont retirés des batteries AGM.
28
86333220 CS20
When servicing machine, avoid contact with
battery acid.
Lors de l'entretien de la machine, évitez tout
contact avec l'acide de batterie.
Maintenance
Battery Maintenance
1. When cleaning the batteries, use a solution of
baking soda and water. Do not allow the cleaning
fluid to enter the battery cells, electrolyte will be
neutralized.
2. Maintain the proper electrolyte level in each battery
cell. If a cell should accidentally overflow, clean
immediately.
3. Wipe off the top of the batteries at least once a
week.
Batteries emit hydrogen gas. Explosion or fire can
result. Keep sparks and open flame away. Keep
covers open when charging.
Les batteries émettent du gaz hydrogène. Une
explosion ou un incendie peut en résulter.
Maintenez les étincelles et les flammes nues à
l’écart. Gardez les carters ouverts lors du chargement.
Wear eye protection and protective clothing when
working with batteries.
Portez des lunettes de protection et des vêtements
de protection lorsque vous travaillez avec des
batteries.
4. Test battery condition with a hydrometer at least
once a week.
5. Ensure that all connections are tight and all
corrosion removed.
6. Every 4 to 6 months, remove the batteries from the
machine and clean the battery cases and battery
compartm
Charge batteries in a well ventilated area.
Chargez les batteries dans un endroit bien ventilé
86333220 CS20
29
Maintenance
Checking Battery Specific Gravity
Use a hydrometer to check the battery specific gravity.
CHECKING GRAVITY
a. Hydrometer Battery
b. Battery
NOTE: Do not take readings immediately after adding
distilled water, if the water and acid are not thoroughly
mixed, the reading may not be accurate.
Check the hydrometer readings against this chart.
SPECIFIC GRAVITY
°
F (27°C)BATTERY CONDITION
@ 80
1.265100% CHARGED
1.22575% CHARGED
1.19050% CHARGED
1.15525% CHARGED
1.120DISCHARGED
NOTE: If the readings are taken when the battery
electrolyte is any temperature other than 80°F (27°C),
the reading must be temperature corrected.
To find the corrected specific gravity reading when the
temperature of the battery electrolyte is other than 80°F
(27°C): Add (+) to the specific gravity reading 0.004 (4
points), for each 10°F (6°C) above 80° (27°C). Subtract
(-) from the specific reading 0.004 (4 points), for each
10°F (6°C) below 80°F (27°C).
30
86333220 CS20
Loading...