This unit is provided with a Leakage Current
Detection and Interruption circuit (LCDI) built into
the plug of the power supply cord. This device
provides protection to reduce the risk of fire due to
arcing faults in the power-supply cord. Each time
before using the Room Air Conditioner, follow the
"Plug Testing Instructions" given below to ensure
that the LCDI circuit is functioning properly .
PLUG TESTING INSTRUCTIONS:
1. PRESS TEST BUTTON. UNIT SHOULD TRIP .
2. PRESS RESET BUTTON FOR USE.
DO NOT USE IF ABOVE TEST FAILS.
The conductors inside this power supply cord are
surrounded by shields which monitor the leakage
current. These shields are not grounded. Periodically examine the cord for any damage. If the shield
gets exposed, immediately unplug the power
supply cord and do not use the unit.
Do not repair a damaged cord. Replace the damaged
cord only with a new replacement power supply cord
obtained from the manufacturer.
In the event the LCDI Plug of the power supply cord
trips by itself, then first examine the cord for any
damage. If there is no damage to the cord then press
the RESET Button. If the LCDI Plug trips again, then
immediately unplug the power supply cord. Replace
the damaged cord with a new replacement power
supply cord.
To obtain a new replacement power supply cord
contact WindChaser Products Customer Service at:
(800) 405-2943 x102 or e-mail at:
customerservice@windchaserproducts.com.
Do not use The TEST and RESET Buttons as an
on / off switch. They are only meant to be used to
periodically check the LCDI plug.
VERY IMPORTANT
Do not install and use your air conditioner before completely reading these instructions.
This will help you optimize the operation of your air conditioner. Make sure that you haven’t
lost the little box placed on the top of the appliance itself. It contains all accessories,
which are essential for use.
The following advice and instructions should be followed closely:
1. The unit must always be used in an
upright position as it contains a cooling
agent.
2. After unpacking, place the appliance
upright to allow the cooling agent to
stabilize, and wait 3 hours before use.
TO SAVE ENERGY
Blocking of the filter reduces the efficiency
of the air and increases its power
consumption by up to 6%.
Avoid opening doors frequently.
TECHNICAL SPECIFICATIONS
Failure to comply with these
instructions may damage the uprightappliance and would invalidate the
WINDCHASER guarantee.
Using the unit in wine cellars or in any
room with a temperature under 61°F is
not recommended.
Each person present in a room provides
between 100 W and 150 W of heat output.
Consequently, the more people there are in a
room, the less successful the appliance will be
in cooling.
VOLTAGE / FREQUENCY
POWER INPUT
COOLING CAPACITY
MOISTURE REMOVAL
COOLANT
TIMER
AIR FLOW VOLUME
THERMOSTAT
DIMENSIONS (W x H x D)
Weight Net (Gross)
115V / 60Hz
900 W
9000 BTU./H
3.4 Pints / Hour (38.6 Liters / Day)
R-22
12 Hours
188 CFM (Cubic Feet / Minute)
61° - 90°F (16° - 32°C)
18.1” x 30.7” x 12.6”
76 lbs. / 34.5 kgs (86 lbs. / 39 kgs)
1
LEARN INTELLIGENT AIR-CONDITIONING
The unit is electronically controlled which allows precise programming to adjust room
temperature.
Air conditioning does not mean, “cooling down too much!” The use of an air conditioner
allows you to have a pleasant atmosphere by reducing the temperature. This air conditioner
allows you to control the 4 factors that determine optimal comfort in a room.
Humidity Rate: the humidity in a room also
causes a sensation of stifling heat in the
summer. The air conditioner not only cools
down the temperature but also dehumidifies
the air.
Temperature: the main function of an air
Air purity: thanks to the air filter, the unit
removes the dust particles creating a healthier
room atmosphere.
Airflow: The air conditioner regulates the air
flow, allowing the flow to be directed and
ensuring optimal air circulation.
conditioner is to draw hot air out of the room.
**Note: Avoid being in a cold air flow, and do not direct it onto people. To ensure the optimal efficiency of
the appliance, we advise you to keep doors and windows closed, and to take in account the surface of the
walls and windows exposed to the sun. In this case, in order to optimize the functioning of your air
conditioner, we recommend partially closing the window coverings.
SAFETY INSTRUCTIONS
Do not damage the power cord.
Never lay down the appliance while it is working.
Always keep it in an upright position to avoid any
damage in the cooling system.
Never splash water on the appliance’s cabinet or on the
control panel.
Be sure that the air inlets and outlets are not blocked or
covered up.
Never place anything on top of the unit and do not cover
it with any kind of cloth while it is plugged in or in-use.
The air conditioner has been designed to be used only
in a house, office and similar conditions and it should
not be used for any other purpose.
Never connect the appliance to a defective socket.
Plug the appliance in a properly grounded dedicated
15 amp socket. Check your breaker box to determine
which circuit the socket is on.
Make sure that the appliance is correctly connected
before switching it on.
Never unplug the air conditioner while it is working.
This could damage the electronic circuits.
To turn on the unit, always use the switch on the control
panel.
Do not bend or crush the warm air exhaust hose.
It is dangerous to modify or to change the characteristics
of the appliance.
Prevent children from climbing on the appliance.
Do not place the air conditioner near curtains (minimum
distance 1.5 ft.).
Do not place the power cord under a carpet.
Never install the appliance in direct sunshine or in the
rain.
When used for the first time, and every time it is turned
on, it takes the unit about 3 minutes to be
operational.
Keep the area around the warm air outlet sufficiently
clean and make sure that it is not congested.
For any repairs, refer directly to our customer
service department. Repairs carried out by
unqualified people may cause damage or may even
be dangerous and void the warranty.
Any damage resulting from failure to comply
with these instructions is excluded from the
warranty.
2
PARTS ILLUSTRATION
Figure A - Front View
1) Control Panel
2) Cold air Outlet
3) Louvers
(5)
(4)
(3)
(2)
(1)
C
(12)
Figure C - Control Panel
1) Power ON/OFF Button
2) Alarm Indicator Light
3) Fan ON/OFF Indicator Light
4) Dehumidifier ON/OFF
Indicator Light
5) AC ON/OFF Indicator Light
6) AC Fan Speed Indicator Lights
(11)
(6)
Figure B - Rear View
4) Air Filter
5) Rating Plate
6) Condensate Drain Hole
7) Warm Air Outlet
(7)(8)
(10)
7) Timer ON/OFF Indicator Light
8) Thermostat and Timer Display Panel
9) Thermostat and Timer Adjustment
Buttons
10) Timer ON/OFF Button
11) AC Fan Speed Button
12) Mode Button
(9)
3
Loading...
+ 9 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.