INSTRUCTION MANUAL
PACR12 PORTABLE AIR CONDITIONER
BEFORE INITIAL USE
Attach your purchase receipt here
For your reference:
Serial No: Date of Purchaser:
Name and Address of Dealer:
UNPACKING INSTRUCTIONS
1. Place the unit in an upright position before unpacking.
2. Slide off the two packing straps. DO NOT CUT THEM. Save them for
future use.
3. Slide the carton up and it will release from the base.
4. Carefully lift the carton over the unit.
5. The remote control unit, exhaust tube and accessories are located in
the styrofoam on top of the unit.
6. Save ALL packaging for off season storage.
PLEASE CAREFULLY READ AND KEEP THESE
INSTRUCTIONS FOR FUTURE REFERENCE
CONTENTS
SAFETY INSTRUCTIONS 2
LEARN INTELLIGENT AIR CONDITIONING 2
IMPORTANT INSTRUCTIONS 3
ENERGY SAVING TIPS 3
TECHNICAL SPECIFICATIONS 3
PARTS ILLSTRATION 4
CONTINUOUS DRAIN FEATURE 5
EXHAUST KIT INSTALLATION 6
OPERATING INSTRUCTIONS AND FUNCTIONS 8
CLEANING THE UNIT 10
TROUBLESHOOTING GUIDE 11
PRODUCT LIMITED WARRANTY 12
1
SAFETY INSTRUCTIONS
Do not damage the power cord.
Never lay down the unit while it is working.
Always keep it in an upright position to avoid any
damage to the cooling system.
Operate this unit in an ambient temperature of 90
or lower.
Be sure that the air inlets and outlets are not blocked or
covered up.
Never place anything on top of the unit and do not cover
it with any kind of cloth while it is plugged in or in-use.
Your air conditioner has been designed to be used
only in a house, office and similar conditions and it
should not be used for any other purpose.
Never connect the unit to a defective socket.
This unit needs at least 12Amps of electricity to start
it’s compressor. Plug the unit into a properly grounded
dedicated 15Amp socket.
Check your breaker box to determine which circuit the
socket is on.
Make sure that the unit is correctly connected before
turning on the unit’s power.
Never unplug the air conditioner while it is working. This
could damage the electronic circuits.
To avoid tripping the circuit, DO NOT USE AN
EXTENSION CORD FOR THIS UNIT.
o
To turn on your unit, always use the switch on the control
panel.
Do not bend or crush the warm air exhaust hose.
It is dangerous to modify or to change the characteristics
of the unit.
Prevent children from climbing on the unit.
Do not place the air conditioner near curtains (minimum
distance 1.5 ft.).
Do not place the power cord under a carpet.
Never install the unit in direct sunshine or in the rain.
When used for the first time, and every time it is turned
on, it takes your unit up to 3 minutes to be operational.
Keep the area around the warm air outlet sufficiently
clean and make sure that it is not congested.
For any repairs, refer directly to our customer ser-
vice department. Repairs carried out by unqualified
people may cause damage or may even be dangerous
and void the warranty.
Any damage resulting from failure to comply
with these instructions is excluded from the
warranty.
LEARN INTELLIGENT AIR-CONDITIONING
This Portable Air Conditioner is electronically controlled, which allows precise programming
to adjust the room temperature. This unit is a small appliance that adjusts the temperature
and humidity in a room. It’s flexibility makes it easy to use in different applications and in
various rooms. This unit is designed for use in a home, office and computer type room.
This air conditioner allows you to control the 4 factors that determine optimal comfort in
a room.
Humidity Rate: the humidity in a room also
causes a sensation of stifling heat in the
summer. Your air conditioner not only cools
down the temperature, but dehumidifies
the air as well.
Temperature: the main function of an air
conditioner is to draw hot air out of the room.
**Note: Avoid being directly in front of the cold airflow and do not direct it onto people. To ensure the
optimal efficiency of the unit,we advise you to keep doors and windows closed, and to take into account
the surface of the walls and windows exposed to the sun. In this case, in order to optimize the functioning
of your air conditioner, we recommend partially closing window coverings.
Air purity: The air filter removes dust particles
from the room air, creating a healthier room
atmosphere.
Airflow: The air conditioner regulates the
airflow, allowing the flow to be directed and
ensuring optimal air circulation
2
IMPORTANT INSTRUCTIONS
Do not install and use your air conditioner before completely reading these instructions.
This will help you optimize the operation of your air conditioner. Make sure that you haven’t
lost the small box placed on the top of the unit; it contains all accessories, which are
essential for use.
The following advice and instructions should be followed closely:
1. Your unit must always be used in an
upright position because it contains a
cooling agent.
2. After unpacking, place the unit upright to
allow the cooling agent to stabilize, and wait
3 hours before use.
ENERGY SAVING TIPS
Blocking of the filter reduces the efficiency
of the air and increases its power
consumption by up to 6%.
Avoid opening doors frequently.
TECHNICAL SPECIFICATIONS
Cooling Capacity
Power Input
Failure to comply with these instructions
may damage the unit and will invalidate the
warranty.
Using your unit in wine cellars or in any
room with a temperature under 61°F is not
recommended.
Each person present in a room provides
between 100 Watts and 150 Watts of heat.
Consequently, the more people there are in a
room, the less effective the unit will be in
cooling.
12,000 BTU/Hour
1200 Watts / 10Amps
Coolant
Moisture Removal
Airflow Volume
Temperature Range
Voltage/Frequency
Product Dimension (WxHxD)
Product Measurement
Product Weight
Drain Hose Length
Exhaust Hose Length
Exhaust Hose Diameter
Condensation Tank Capacity
R-22
3 1/2 Pints / Hour (40 Liters / Day)
247 CFM (Cubic Feet / Minute)
61o - 90oF (16o - 32oC)
120V/60Hz
18 in (W) x 16 1/2 in (D) x 35 in (H)
460mm(W) x 420mm(D) x 880mm(H)
6 Cubic Feet
Net Weight: 97 lbs. / 44 kgs.
Gross Weight: 118 / 54 kgs.
9 1/2 feet
11 1/2 inches (compressed); Extends up to 5 feet
Inside: 4 3/8 inches / Outside: 5 1/8 inches
2 3/4 Cups (0.65 Liters)
3