Wincomm WMP-19B, WMP-22B User Manual

WMP-19B/22B
Medical Panel PC
USER’S MANUAL
Copyright© ,2016. All rights reserved
All other brand names are registered trademarks of their respective owners.
The information contained in this document is subject to change without notice
ii
Date
Version
Description
Remark
2016/5/31
1.0
First release
James
Version Change History
WMP-19B/22B User’s manual
iii
Acknowledgments
Intel® Celeron processor is registered trademarks of Intel®
Corporation.
IBM, PC/AT, PS/2 are trademarks of International Business
Machines Corporation.
Microsoft
®
Windows is a registered trademark of Microsoft
Corporation.
RTL is a trademark of Realtek Semi-Conductor Co., Ltd. C&T is a trademark of Chips and Technologies, Inc. UMC is a trademark of United Microelectronics Corporation. ITE is a trademark of Integrated Technology Express, Inc. Intel is a trademark or registered trademark of Intel
Corporation.
Microsoft Windows is a registered trademark of Microsoft
Corporation.
®
Winbond is a registered trademark of Winbond Electronics
Corporation.
All other product names or trademarks are properties of their respective owners.
WMP-19B/22B User’s manual
iv
FCC Class B
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 18 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a residential environment. This equipment generates, uses and can radiate radio frequency energy. If not installed and used in accordance with this user manual, it may cause harmful interference to radio communications. Note that even when this equipment is installed and used in accordance with this user manual, there is still no guarantee that interference will not occur. If this equipment is believed to be causing harmful interference to radio or television reception, this can be determined by turning the equipment on and off. If interference is occurring, the user is encouraged to try to correct the interference by one or more of the following measures:
Increase the separation between the equipment and the receiver Connect the equipment to a power outlet on a circuit different from
that to which the receiver is connected
Consult the dealer or an experienced radio/TV technician for help
Warning:
Any changes or modifications made to the equipment which are not expressly approved by the relevant standards authority could void your authority to operate the equipment.
To avoid risk of electric shock, this equipment must only be connected to a supply mains with protective earth.
Do not modify this equipment without authorization of the manufacturer.
WMP-19B/22B User’s manual
v
Safety Instructions
Intended use
The WMP-19B/22B is intended to serve as a medical monitor which is designed for general purpose for hospital environment. It shall not be used for life-supporting system.
Intended User profile
The equipment is intended for infant or adults by profession Health care professionals.
Greeting & Setup
Thank you for purchasing the WMP-19B/22B unit. We wish that this unit will be durable and reliable in providing your medical application needs. Please follow the instructions below to ensure the unit continues to have high performance.
Unpacking
After opening the carton, there will be a medical panel PC unit with an accessory box. Examine the contents to see if there are damages to the unit and if all accessories are present.
Setting up
Please read this manual carefully and remember to keep this manual for future reference.
Safety Instructions & Cleaning
The unit has undergone various tests in order to comply with safety standards. Inappropriate use of the open frame unit may be dangerous. Please remember to follow the instructions below to insure your safety during the installation and operating process.
Transporting & Placement of unit
1. When moving the unit on a cart; be very cautious. Quick
stops, excessive forces and uneven surfaces may cause the cart to overturn thus risking the unit to fall to the ground.
2. If the medical panel PC unit does fall to the ground,
immediately turn the power off and disconnect cords. Then
WMP-19B/22B User’s manual
vi
contact a service technician for repairs. Continual use of the unit may result cause a fire or electric shock. Also, do not repair the unit on your own.
3. Having two or more people transporting the display unit is
recommended. In addition, when installing the unit by suspending it also requires two or more people.
4. Before suspending the unit, make sure the material used
for suspension is sturdy and stable. If not properly suspended, the display unit may fall and cause serious injury to people standing nearby as well as to the unit itself.
5. If you wish to mount the display unit, remember to use
only the mounting hardware recommended by the manufacturer.
Electrical and Power Source Related
1. This medical panel PC unit must operate on a power source
as shown on the specification label. If you are not sure what type of power supply used in the area, consult your dealer or local power supplier.
2. The power cords must not be damaged. Applied pressure,
added heat, and tugging may damage the power cord.
3. The power cord must be routed properly when setup takes
place. We advise that this aspect measure is to prevent people from stepping on the cords or while the unit is suspended to prevent flying objects from getting tangled with the unit.
4. For plug-in equipment, the power outlet socket must be
located near the equipment and must be easily accessible.
5. Do not overload the AC outlets or extension cords.
Electrical shocks or fires may occur from overloading.
6. Do not touch the power source during a thunderstorm.
7. If your hands are wet, do not touch the plug.
8. Use your thumb and index finger, grip firmly on the power
cord to disconnect from the electrical socket. By pulling the power cord, may result in damaging it.
WMP-19B/22B User’s manual
vii
9. If the unit is not going to be in use for an extended period
of time, remember to disconnect the unit.
10. The medical panel PC unit uses voltage between
100-240VAC. Connect the unit to a power source with the same numerical value as shown. Please use only the power cord provided by the dealer to ensure safety and EMC compliance.
Various Factors of Environment
1. Do not insert objects into the openings.
2. Do not have liquids seep into the internal areas of the
medical panel PC unit.
3. Having liquids seep in or inserting objects into the unit
may result in electric shocks from taking and/or short circuiting the internal parts.
4. Do not place the medical panel PC unit in the presence of
high moisture areas.
5. Do not install the medical panel PC unit in a wet
environment.
6. Do not place near unit near heat generating sources.
7. Do not place the unit in a location where it will come in
contact with fumes or steam.
8. Remember to keep the medical panel PC unit away from
the presence of dust.
9. If water has flow in or seep in, immediately disconnect the
open frame unit. Then contact a service technician for repairs.
Ventilation Spacing
1. Do not cover or block the openings on the top and back
sides of the display unit. Inadequate ventilation may cause overheating thus reducing the lifespan of the unit.
2. Unless proper ventilation is present, do not place unit in an
enclosed area; such as a built-in shelf. Keep a minimum distance of 10 cm between the display unit and wall.
WMP-19B/22B User’s manual
viii
No power
1. Connect the AC adapter to the computer, and then plug it into an AC outlet.
2. Turn on the computer.
Operating principle
A Medical Panel PC has four main components: the
arithmetic logic unit (ALU), the control unit, the memory, and the input and output devices (collectively termed I/O). These parts are interconnected by buses, often made of groups of wires.
The control unit, ALU, and registers are collectively known as
a central processing unit (CPU).
Inside each of these parts are thousands to trillions of small
electrical circuits which can be turned off or on by means of an electronic switch. Each circuit represents a bit (binary digit) of information so that when the circuit is on it represents a "1", and when off it represents a "0" (in positive logic representation). The circuits are arranged in logic gates so that one or more of the circuits may control the state of one or more of the other circuits.
Cleaning the unit
1. Remember to turn off the power source and to unplug the
cord from the outlet before cleaning the unit.
2. Carefully dismount the unit or bring the unit down from
suspension to clean.
3. Please use a dry soft cloth to clean the unit.
4. Take a dry cloth and wipe the unit dry. Remember to avoid
having liquids seep into the internal components and areas of the medical panel PC unit.
Error message / Troubleshooting
Servicing, Repairing, Maintenance & Safety Checks
1. If the unit is not functioning properly, observe the
performance level of the display closely to determine what type of servicing is needed.
WMP-19B/22B User’s manual
ix
ISO 7000-0434: Caution.
ISO 7000-1641: Follow operating instructions or Consult instructions for use.
IEC 60417 -5009: STAND-BY. IEC 60417-5031: Direct current.
2. Do not attempt to repair the medical panel PC unit on your
own. Disassembling the cover exposes users’ to high
voltages and other dangerous conditions. Notify and request a qualified service technician for servicing the unit.
3. To avoid risk of electric shock, this equipment must only be
connected to a supply mains with protective earth.
4. If any of the following situations occur turn the power
source off and unplug the unit. Then contact a qualified service technician.
(a) A liquid was spilled on the unit or objects have fallen
into the unit.
(b) The unit is soaked with liquids. (c) The unit is dropped or damaged. (d) If smoke or strange odor is flowing out of the operating
unit.
(e) If the power cord or plug is damaged. (f) When the functions of the unit are dysfunctional.
5. When replacement parts are needed for the medical panel
PC unit, make sure service technicians use replacement parts specified by the manufacturer, or those with the same characteristics and performance as the original parts. If unauthorized parts are used it may result in starting a fire, electrical shock and/or other dangers.
WMP-19B/22B User’s manual
x
EU-wide legislation, as implemented in each Member State, requires that waste electrical and electronic products carrying the mark (left) must be disposed of separately from normal household waste. This includes monitors and electrical accessories, such as signal cables or power cords. When you need to dispose of your display products, please follow the guidance of your local authority, or ask the shop where you purchased the product, or if applicable, follow any agreements made between yourself.
The mark on electrical and electronic products only applies to the current European Union Member
States.
WMP-19B/22B User’s manual
xi
When networking with electrical devices, the operator is responsible for ensuring that the resulting system meets the requirements set forth by the following standards:
EN 60601-1 (IEC 60601-1)
Medical electrical equipment Part 1: General requirements for safety
EN 60601-1-1 (IEC 60601-1-1)
Medical electrical equipment Part 1-1: General requirements for safety Collateral standard: Safety requirements for Medical electrical systems
EN 60601-1-2 (IEC 60601-1-2)
Medical electrical equipment Part 1-2: General requirements for safety Collateral standard: Electromagnetic compatibility; Requirements and tests
Accessory equipment connected to the analog and digital interfaces must be in compliance with the respective nationally harmonized IEC standards (i.e. IEC 60950 for data processing equipment, IEC 60065 for video equipment, IEC 61010-1 for laboratory equipment, and IEC 60601-1 for medical equipment.) Furthermore all configurations shall comply with the system standard IEC 60601-1-1. Everybody who connects additional equipment to the signal input part or signal output part configures a medical system, and is therefore, responsible that the system complies with the requirements of the system standard IEC 60601-1-1. The unit is for exclusive interconnection with IEC 60601-1 certified equipment in the patient environment and IEC 60XXX certified equipment outside of the patient environment. If in doubt, consult the technical services department or your local representative.
WMP-19B/22B User’s manual
xii
Caution:
DO NOT LEAVE THIS EQUIPMENT IN AN UNCONTROLLED ENVIRONMENT WHERE THE STORAGE TEMPERATURE IS BELOW
-20° C (-4° F) OR ABOVE 60° C (140° F). THIS MAY DAMAGE THE EQUIPMENT.
This equipment shall not be used in life support systems.
The user is not to touch SIP/SOPs and the patient at the same time.
Caution – Use suitable mounting apparatus to avoid risk of injury.
Caution - Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries according to the instructions.
The sound pressure level at the operator’s position according to
IEC 704-1:1982 is no more than 70dB (A).
A) Grounding reliability can only be achieved when the equipment
is connected to an equivalent receptacle marked “Hospital Only” or “Hospital Grade”.
B) Use a power cord that matches the voltage of the power outlet,
which has been approved and complies with the safety standard of your particular country.
C) Caution: This adapter Sinpro HPU180A-108 is a forming part of
the medical device
Contact information:
Wincomm Corporation 3F, No.14, Prosperity Road II, Science-Based Industrial Park, Hsinchu, Taiwan 300, R.O.C TEL: (886) 3 5780000
E-Mail: Sales@wincomm.com.tw
WMP-19B/22B User’s manual
xiii
Table of Contents
Acknowledgments ...................................... iii
FCC Class B ............................................... iv
Safety Instructions ...................................... v
Introduction ............................................ 1
Product Description .................................... 1
Package list ............................................... 2
Features ................................................... 3
Specifications ............................................ 4
Guidance and manufacturer’s declaration –
electromagnetic emissions ...................... 7
Guidance and manufacturer’s declaration –
electromagnetic immunity ...................... 8
Immunity .................................................. 9
Cleaning/Disinfecting ................................. 11
Getting Started ..................................... 12
System Set Up .......................................... 12
Dimension ................................................ 13
System View............................................. 15
Disconnect Device ..................................... 18
BIOS Setup ........................................... 19
Appendix ............................................... 31
A. Jumper settings and Connectors .............. 31
B. Battery Pack Specifications (optional kit) .. 50 C. How to disable battery when system hang up
-WMP-19B/22B ......................................... 51
D. Scrap Computer Recycling ...................... 52
WMP-19B/22B User’s manual
1
Introduction
Product Description
The WMP-19B/22B Medical Panel PC is based on Intel 5th generation Core i mobile CPU (H series) processor, it
accommodates one 2.5” SATA III hard disk drive and up to 16GB DDR3L SODIMM.
The high brightness LCD, smart fan solution, integrated multimedia functions and extensive expansion options make them the perfect platform upon which to build comprehensive lifestyle computing applications.
The WMP-19B/22B includes all the features of a powerful computer into a slim and attractive chassis. WMP-22B has a 250nits 21.5” TFT display with 1920 x 1080 resolutions. WMP-19B has a 19” 350nits TFT display with 1280 x 1024
resolutions. Integrating with high brightness LCD is easier to analyze DICOM image.
The WMP-19B/22B is compact, two Giga LAN and selectable WLAN network compatible PC with full safety and medical approval and features to control a dedicated system with a wide variety of applications. Combining the WMP-19B/22B into your system can achieve both cost-saving and efficient improvements.
Common applications include LIS (Lab Information Systems) and Electronic Medical Record. The WMP-19B/22B are definitely your perfect choices.
WMP-19B/22B User’s manual
2
Package list
Before you begin installing your Medical Station, please make sure that the following items have been shipped:
The WMP-19B/22B Medical Panel PC unit User's manual, chipset drivers Power Adapter x 1 (Mf:Sinpro, type/model: HPU180A-108) Power cord – Hospital grade used (US type), or other type in
UK, EUetc.
Screw x 8 (VESA 75/100 use)
WMP-19B/22B User’s manual
3
Features
Anti-bacteria (MRSA) plastic housing 21.5" full HD (1920X1080) / 19” (1280x1024) Panel High performance 4Supports Dual Channel DDR3L SODIMM up to 16GB P.cap Multi-Touch Screen Easy wipe surfaces with no internal corners IP65 at front side Smart Fan solution Two mini PCI-e expansion (One full size and one half size) HDD Anti-vibration mechanism Supports PCI-E x16 riser card (option) Easy clean full flat 5 wire resistive touch screen (customized
order configuration)
th/5th
generation intel Core i mobile CPU
USB/LAN/COM isolated module by different configuration
(optional order configuration)
Optional 28W battery pack, desktop stand DICOM Compliance (project customized)
WMP-19B/22B User’s manual
4
Display
21,5” 250 nits 1920x1080 TFT LCD 19” 350 nits 1280x1024 TFT LCD
CPU Support
FCBGA1364 4th/5th generation Intel® Core
i7/i5 processor (47W max.)
Disk Drive Space
2.5” Hard Disk Drive (SATA III)
Expansion
One PCI-E x 16 expansion slot (+3.3V loaded 3A, total loaded 9.9W)
Button
Power Button// Audio adjustment (+)(-) // brightness (+)(-) // LCD on/off // Clean me(auto release after 1 minute)
I/O
Standard version
PCI-E x 16 slot *1(optional riser card) RS-232 port *1 + RS-232/422/485 port *1 USB 3.0 port *4 DC-in w/ lock function *1 Gigabit LAN RJ-45 Connectors *2 DP output *2 Sound: Line-in *1 Line-out *1 2W Speaker *2 (WMP-19B) / 1.5W Speaker *2 (WMP-22B)
Isolated version
Isolated 4KV USB2.0 *1 Isolated 4KV GigaLAN *1 Isolated 4KV RS-232 *1, RS-232/422/485 *1 (The isolated ports verified through Dielectric test 4000Vac only) RS-232 port *1 + RS-232/422/485 port *1 USB 3.0 port *4 DC-in w/ lock function *1 Gigabit LAN RJ-45 Connectors *2 DP output *2 Sound: Line-in *1 Line-out *1 2W Speaker *2 (WMP-19B) / 1.5W Speaker *2 (WMP-22B)
Specifications
[
Hardware Specifications
WMP-19B/22B User’s manual
5
Model Name
WMP-22B
WMP-19B
Display Type
21.5” LED
19LED
Max. Resolution
1920 x 1080
1280 x 1024
Contrast Ratio
1000 : 1 (Typ)
1000 : 1 (Typ)
Pixel Pitch (um)
248.25 × 248.25
294 x 294
Luminance (cd/m2)
250 (TYP)
350 (TYP)
Viewing Angle
170°(H)
170°(H)
160°(V)
160°(V)
Power
Close-frame
MFR
Sinpro
Type
HPU180A-108
Input Rating
AC 100 ~ 240 V, 1.2 – 0.5A @ 47 ~ 63 Hz
Output Rating
DC 24V, 7.5A
MTBF
100,000 hrs operation at 25°C
Classification
Power by Class I certified power adapter. No applied part.
Mode of operation
Continuous operation
System input rating
DC 24V, 7A
Architecture
Close-frame
Front Bezel
PCT touch screen / PET bezel with resistive touch screen
Color
Medical-white
Mounting / Holder
VESA 75/100mm
Construction
3mm ABS + PC TYPE Plastic housing
Dimension (WxHxD)
WMP-22B: 540 x 375 x 78 mm WMP-19B: 450 x 420 x 85.3 mm
Net Weight
WMP-22B: 8.0 kg (w/o power adapter)
WMP-19B: 7.5 kg (w/o power adapter)
Packing Filler
PE
LCD Specifications
Cautions:
Continuous displaying fixed pattern may induce image sticking.
It’s recommended to use screen saver or moving content periodically if fixed pattern is displayed on the screen.
Power Adapter Specifications
Mechanical Specifications
WMP-19B/22B User’s manual
6
Temperature
Operating: 0°C to 40°C (32°F ~104°F) Storage, Transportation: -20°C to 60°C (-4°F ~140°F)
Humidity
Operating: 10% to 90%@ 40°C, non-condensing Storage, Transportation: 10% to 90%, non-condensing
Vibration
Operating: 15g/0.53 oz, 11 ms, half sine wave Non-operating: 50g/1.76 oz, 11 ms, half sine wave
Shock
Operating: 5 ~ 17 Hz , Amplitude0.117 ~ 500Hz ,
Acceleration1.0G Non-operating:10~55Hz/0.15g, 55~500Hz/2.0g
Altitudes
Operational: up to 3000 m (9842 feet) Shipping: up to 12192 m (40000 feet)
Pressure
700 – 1060 hPa (Operation) 186 – 1060 hPa (Storage) 186 – 1060 hPa (Transportation)
EMI / Safety
CE / FCC / VCCI Class B/UL 60601-1/EN 60601-1
IP
Front bezel, IP-65 Certified
Noise
Under 30db (at 25°C)
Type
Full flat projective capacitive touch panel
Interface
Controller with USB interface, 5V
Resolution
100ppi to 25ppi Based WIN7 definition ppi (Pixel per inch)
Light Transmission
90% ± 3%
Life Time
100M times
Type
Full flat 5-wire, Analog Resistive
Interface
USB interface, 5V
Resolution
4096 x 4096
Light Transmission
>78% at 550 nm wavelength
Life Time
35M times, 250g at same place
Environmental Specifications
Touch Screen Configuration 1 - P.cap touch
Configuration 2 - 5 wire Resistive touch
WMP-19B/22B User’s manual
Loading...
+ 46 hidden pages