Read and understand all instructions in
the manual before starting and operating the
generator set.
USING THIS MANUAL
Congratulations on your choice of a Winco generator
set. You have selected a high-quality, precision-engineered
generator set designed and tested to give you years of
satisfactory standby service.
To get the best performance from your new engine
generator set, it is important that you carefully read and
follow the operating instructions in this manual.
Should you experience a problem please follow the
“Things To Check” near the end of this manual. The warranty
listed in this manual describes what you can expect from
WINCO should you need service assistance in the future
COPY YOUR MODEL AND SERIAL NUMBER
HERE
No other WINCO generator has the same serial number as
yours. It is important that you record the number and other
vital information here. If you should ever need to contact us
on this unit it will help us to respond to your needs faster.
MODEL_____________________________________
SERIAL NUMBER____________________________
PURCHASE DATE____________________________
DEALER____________________________________
TABLE OF CONTENTS
INTRODUCTION i
GUIDE TO PRODUCT SAFETY1
BASIC INFORMATION2
AC Electrical Connections6
DC Electrical Connections7
TRANSFER SWITCH INSTALLATION (UL)8
AC Electrical Connections8
DC Electrical Connections8
INITIAL START-UP8
EXERCISER CLOCK9
TROUBLESHOOTING INFORMATION10
LP/NG CONVERSION10
CONTROL PANEL WIRING12
CONTROL PANEL LAYOUT13
AC WIRING - THREE PHASE
277/480 Volt14
120/208 Volt14
120/240 Volt15
AC WIRING - SINGLE PHASE
120/240 Volt15
VOLTAGE REGULATOR WIRING16
DC SCHEMATIC - WIRING DIAGRAM17
INTERNAL GENERATOR CONNECTIONS
PSS27LS18
PSS40LS19
OUTLINE DRAWING
PSS40LS20
PSS27LS21
12 MONTH WARRANTY22
PROPER USE AND INSTALLATION
You must be sure your new engine generator set is:
*Properly serviced before starting
*Operated in a well ventilated area
*Properly exhausted and gases safely dispersed
*Wired by a qualified electrician
*Operated only for its designed purposes
*Used only by operators who understand its operation
*Properly maintained
Page i
Page 3
SAFETY INFORMATION
2.FIRE HAZARD - Natural gas and L.P. present a hazard of
possible explosion and/or fire.
This engine generator set has been designed and manufactured to allow safe, reliable performance. Poor maintenance,
improper or careless use can result in potential deadly hazards;
from electrical shock, exhaust gas asphyxiation, or fire. Please
read all safety instructions carefully before installation or use.
Keep these instructions handy for future reference. Take special
note and follow all warnings on the unit labels and in the
manuals.
DANGER indicates an imminently hazardous situation which, if
not avoided, will result in death or serious injury. This signal
word is to be limited to the most extreme situations.
CAUTION indicates a potentially hazardous situation which, if
not avoided, may result in minor or moderate injury. It may also
be used to alert against unsafe practices.
CAUTION is also used on the unit labels and in this manual to
indicate a situation that could result in serious damage or
destruction of the equipment and possible personal injury.
a.Do not smoke or use open flame near the generator
set.
b.Keep a fire extinguisher nearby and know its proper use.
Fire extinguishers rated ABC by NFPA are appropriate.
3.DEADLY EXHAUST GAS - Exhaust fumes from any gasoline engine contain carbon monoxide, an invisible, odorless
and deadly gas that must be mixed with fresh air.
a.Operate only in well ventilated areas.
b.Never operate indoors.
c.Never operate the unit in such a way as to allow exhaust
gases to seep back into closed rooms (i.e. through
windows, walls or floors).
4.NOISE HAZARD - Excessive noise is not only tiring, but
continual exposure can lead to loss of hearing.
a.Use hearing protection equipment when working
around this equipment for long periods of time.
b.Keep your neighbors in mind when permanently install-
ing this equipment.
5.CLEANLINESS - Keep the generator and surrounding area
clean.
a.Remove all grease, ice, snow or materials that create
slippery conditions around the unit.
b.Remove any rags or other material that could create
potential fire hazards.
c.Carefully wipe up any gas or oil spills before starting the
unit.
d.Never allow leaves or other flammable material to build
up around the engine exhaust area.
6.SERVICING EQUIPMENT - All service, including the
installation or replacement of service parts, should be
performed only by a qualified technician.
1.ELECTRIC SHOCK - The output voltage present in this
equipment can cause a fatal electric shock. This equipment
must be operated by a responsible person.
a.Do not allow anyone to operate the generator without
proper instruction.
b.Guard against electric shock.
c.Avoid contact with live terminals or receptacles.
d.Use extreme care if operating this unit in rain or snow.
e.Use only three-prong grounded receptacles and
extension cords.
f.Be sure the unit is properly grounded to an external
ground rod driven into the earth.
60706-148
Page 1
a.Use only factory approved repair parts.
b.Do not work on this equipment when fatigued.
c.Never remove the protective guards, cover, or recep-
tacle panels while the engine is running.
d.Use extreme caution when working on electrical compo-
nents. High output voltages from this equipment can
cause serious injury or death.
e.Always avoid hot mufflers, exhaust manifolds, and
engine parts. They all can cause severe burns instantly.
f.Installing a generator set is not a “do-it-yourself” project.
Consult a qualified, licensed electrician or contractor.
The installation must comply with all national, state, and
local codes.
g.Always make sure unit is disabled before placing your
hands anywhere near the fan, belts, alternator or water
hoses.
1108-20
Page 4
TESTING POLICY:
Before any generator is shipped from the factory, it is fully
checked for performance. The generator is loaded to its full
capacity, and the voltage, current, and frequency are carefully
checked.
Rated output of generators is based on engineering tests of
typical units, and is subject to, and limited by, the temperature,
altitude, fuel, and other conditions specified by the manufacturer
of the applicable engines.
INTRODUCTION AND DESCRIPTION
The package standby engine generator set includes all items
necessary for a completely automatic standby power system as
standard equipment. The entire package is then tested to
insure proper operation of all components and the total system
performance and reliability.
DESCRIPTION
This package power system is designed to automatically provide
standby power to unattended loads during electrical outages.
Upon an interruption of normal electrical service this package
power system electrical control circuits will automatically start the
engine. The generator will produce electrical power and the
Automatic Transfer Switch (A.T.S.) will automatically transfer the
electrical loads to the engine-generator set. Upon restoration of
normal electrical service the A.T.S. will sense return of the normal
commercial power and retransfer the load back to normal
commercial power source. The engine control circuits will begin a
3 minute cool-down cycle, after which the fuel supply will be shut
off and the engine ignition system disabled.
These package power systems consist of two major components:
1) WINCO AUTOMATIC TRANSFER SWITCH
(Non-UL model)
The table below shows the different Automatic Switch sizes
typically used with each unit.
CONTACTOR RATING
MODELVOLTAGELINEGENERATOR
PSS27LS-3120/240230150
PSS27LS-4120/208230150
PSS27LS-17120/240230150
PSS27LS-18277/480**
PSS40LS-3120/240230230
PSS40LS-4120/208230150
PSS40LS-17120/240230150
PSS40LS-18277/480**
*Special order UL Transfer Switches
These Automatic Transfer Switches (A.T.S.) are wall mount
switches designed for inside installation. The A.T.S. consists of
a line side contactor and a generator side contactor. The
contactors are both electrically and mechanically interlocked. A
seven day electronic exerciser clock is installed in the A.T.S. as
standard equipment. The A.T.S. also contains the power failure
sensing circuitry necessary to send a start/stop signal to the
engine generator set.
2) ENGINE/GENERATOR
PSS27LS- The engine generator set consists of a GM 3.0L
Industrial, four cylinder, liquid cooled engine equipped to run on
L.P./N.G. fuel. The engine operates at 1800 rpm and frequency
regulation is maintained by the electronic governor within .5
cycles variation, from no load to rated load. The 27,000 watt
(27kW) generator is a single bearing, direct drive, rotating field
design. The generator is connected to the engine flywheel via
flexible drive disks. The engine generator is mounted in a drip
proof enclosure for outside installation. Connection boxes are
provided to all customer connections (both AC output and DC
control). A customer supplied 12 Volt, 650 CCA (BCI group 24)
battery is required to complete the installation. Engine operation
is controlled by an Electronic Engine Control Module (E.C.M.)
mounted in the engine generator enclosure. The E.C.M. is
equipped standard with a 3 second start delay, 3 minute cool
down delay and cycle cranking, featuring 5 cycles of 12 seconds
on/12 seconds off.
PSS40LS - The engine generator set consists of a GM 4.3L ,V-6
Industrial, liquid cooled engine equipped to run on L.P./N.G.
fuel. The engine operates at 1800 rpm and frequency regulation
is maintained by the engine governor within .5 cycles variation,
no load to rated load. The 40,000 watt (40kW) generator is a
single bearing, direct drive, rotating field design. The generator is
connected to the engine flywheel via flexible drive disks. The
engine generator is mounted in a drip proof enclosure for outside
installation. Connection boxes are provided to all customer
connections (both AC output and DC control). A customersupplied 12 Volt, 650 CCA (BCI group 24) battery is required to
complete the installation. Engine operation is controlled by an
Electronic Engine Control Module (E.C.M.) mounted in the engine
generator enclosure. The E.C.M. is equipped standard with a 3
second start delay, 3 minute cool down delay and cycle cranking,
featuring 5 cycles of 12 seconds on/12 seconds off.
** NOTICE **
These units will automatically transfer if a power outage occurs
while running in an exercise mode.
SPECIFICATIONS
GENERATOR
MODEL WATTSVOLTSAMPHZPHRPM
PSS27LS27,000120/240112*6011800
*Derate 11% for Natural Gas operation. Derate 3.5% per
1000 feet elevation above sea level.
**Derate 18% for Natural Gas operation. Derate 3.5% per
1000 feet elevation above sea level.
Minimum required L.P. Tank size for L.P. Vapor withdrawal
operating at various outside temperatures given in degrees
Fahrenheit (Celsius)
transit. The title to goods rests with the consignee when generators are shipped FOB factory, and only the consignee can legally
file a claim.
**** CAUTION ****
EQUIPMENT DAMAGE - These units are shipped with oil, and a
50/50 mix of coolant. Be sure to check all fluid levels before
operating. See engine manufacturer’s instruction manual for
recommended oil requirements before initial starting.
*Recommend liquid withdrawal at these temperatures.
ENGINE SPECIFICATIONS:
Refer to engine operating and maintenance instructions
** NOTICE **
Regarding Engines - This manual covers the generator portion
of these units. See the separate engine instruction manual for
engine-related problems, detailed engine information and
engine warranty.
** CAUTION **
EQUIPMENT DAMAGE - Be sure to check the engine oil level
frequently as specified in the engine manual.
The engine manufacturer has established an excellent world-wide
engine service organization; engine service is available from a
nearby authorized dealer or distributor; check the Yellow Pages
of the telephone directory under “engines,” or ask the dealer from
whom you purchased the power plant.
The rated power of each engine-generator is limited by the
temperature, altitude and all other ambient conditions specified
by the engine manufacturer. Engine power will decrease 3-1/2%
for each 1000 ft. above sea level, and will decrease an additional
1% for each 10 degrees Fahrenheit above 60 degrees Fahrenheit.
1.Carefully remove the carton.
2.After inspecting the engine-generator for external physical
damage, check for the following items packed inside the carton.
a.Owner’s manual, wiring diagram, and parts list.
b.Engine manufacturer’s instruction manual.
3.Remove main frame hold down bolts, (4).
4.Unit can now be lifted from shipping rails.
INSTALLATION
General Information
*************
***** WARNING ****
*************
PERSONAL INJURY - Before proceeding with the installation, be
sure the operation selector switch is in the "stop" position.
These engine generator sets are available as an unhoused, skid
mounted unit for indoor installation or a skid mounted unit with a
standard or accoustical housing for outdoor installation. All
versions of these units must be bolted solidly to a concrete pad.
The transfer switch is mounted next to your distribution panel
inside the building. Consult a qualified, licensed electrician or
contractor to install and wire the transfer switch. The installation
must comply with all national, state, and local codes.
***** CAUTION ****
UNPACKING INSTRUCTIONS
** NOTICE **
When unpacking the generator set, be sure to inspect it carefully
for freight loss or damage. If loss or damage is noted at the time
of delivery, require that the person making the delivery make
note of the loss or damage on the freight bill, or affix his signature
under the consigner’s memo of the loss or damage. Contact the
carrier for claim procedures.
When loss or damage is noted after delivery, segregate the
damaged material, and contact the carrier for claim procedures.
“Concealed Damage” is understood to mean damage to the
contents of a package which is not in evidence at the time of
delivery by the carrier, but which is discovered later. The carrier
or carriers are responsible for merchandise lost or damaged in
60706-148
EQUIPMENT DAMAGE - These units must be mounted on a
solid concrete pad to prevent air from exiting under the unit.
Allowing air to exit under the unit may cause the unit to overheat
from lack of proper air flow.
Before beginning the installation process recheck the rating of
the generator set and it’s transfer switch rating. Be certain they
can handle the intended load and are compatible with the
entrance voltage, phase and current ratings. Plans for installation
should be prepared with proper attention to mechanical and
electrical engineering detail to assure a satisfactory system
installation. The information in this manual is offered only as a
guide to finalizing your installation plans. For full service
switching the A.T.S. should have a fusible disconnect (circuit
breaker) installed before the switch to protect the contacts.
Page 3
1108-20
Page 6
ENGINE GENERATOR SET MOUNTING
The unit’s main frame should be bolted solidly to a 4 to 6 inch
thick cement pad. The engine-generator is mounted on a subframe which is attached with special shock mounts to the main
frame. This allows the engine-generator free movement without
affecting the control panel which is mounted on the main frame.
Do not shock mount the main frame. Engine vibration will be
transmitted to the control panel causing erroneous start/stop
cycles and premature control failure.
oz operating pressure. This secondary regulator must be at least
10 feet from the engine generator set. Any closer installation will
require a larger line be installed to provide a fuel reservoir. If this
is not done, the demand regulator on the unit and the pressure
regulator in the fuel line will interfere with each other. When this
two (2) stage regulator system is used, a fuel line size of 3/4 to 1
inch is generally adequate for distances up to 300 feet from the
primary to the secondary regulator. (Consult your local fuel
supplier for your exact requirements). The appropriate line size
from the table below is then installed from the secondary regulator to the generator set.
The unit should be mounted to allow for ample working room
around it. A general rule to follow is three (3) feet clearance on
all sides.
FUEL INSTALLATION
The fuel supply should be as close as possible to the engine.
This will reduce the installation cost of fuel runs. The information in this manual is offered to assist you in providing the proper
fuel for your engine. However, this information is only provided to
inform you of the engine’s requirements and assist in making you
aware of the decisions you must make. In no case should the
instructions or information provided be interpreted to conflict with
any local, state or national codes. If in doubt, always consult your
local fire marshal or gas supplier.
*************
***** WARNING ****
*************
FIRE HAZARD - All fuel runs should be installed by a licensed
fuel supplier.
Connect the fuel supply to the inlet of the fuel solenoid (see table
for recommended line size). The pressure at the secondary
demand regulator must be four to six ounces psi (per square
inch) or 7 to 11 inches W.C. (Water column) for vapor withdrawal
units. On units equipped with liquid withdrawal fuel systems full
tank pressure is plumbed to the fuel lock strainer mounted on
the generator rails. The fuel converter mounted on the unit will
handle both vaporization of the fuel and pressure reduction.
INSTALLING THE FUEL LINE
** NOTICE **
The engine generator sets are properly adjusted before they
leave the factory for a specific fuel, either NG (natural gas), LP
(liquid propane vapor) or LPG (liquid withdrawl propane). This
fuel type is noted in your model number. If it becomes necessary
to change the fuel type in the field see information on page 10.
Line Size (vapor system)
Unit location will determine the size of fuel line that is required to
supply the engine with a constant fuel pressure. Refer to the
tables below for fuel line size, fuel consumption and recommended tank size. For distances of 25 feet and over, a two
regulator fuel system is recommended. This is accomplished by
installing a primary regulator at the tank which will reduce the
tank pressure down to 10 to 15 lbs. A secondary regulator is
installed to further reduce the fuel pressure to the required six (6)
*************
***** WARNING ****
*************
PERSONAL DANGER - Do not use galvanized pipe in fuel line
runs. The galvanized coating can become eroded and flake off,
causing possible obstructions in the regulator or fuel valve. The
results could range from inoperative engine start to hazardous
fuel leaks.
Size of pipe normally required for generators operating on
NATURAL/LP gas.
up to 25 feet* over 25 feet*
PSS27LS 1" pipe not recommended
PSS40LS 1" pipe use a two regulator system
* Allow an additional 3 feet for each standard elbow.
Do not use ‘street ells’ (restrictive).
**** CAUTION ****
EQUIPMENT DAMAGE - Be careful when sealing gas line joints.
Excessive sealing compound can be drawn into the solenoid,
regulator or carburetor causing an engine malfunction.
FUEL PRESSURE (vapor system)
Correct fuel pressure cannot be stressed enough. The most
common cause for inoperative systems is an inadequate or
incorrect fuel pressure. Performance of the engine is in direct
relation to the correctness of the fuel system. Shown below is a
block diagram of a typical L.P. or N.G. Installation.
Supply Primary SecondaryGenerator
Tank Regulator Regulator Set
1 23 4
TWO (2) REGULATOR FUEL SYSTEM
Supply PrimaryGenerator
TankRegulator Set
123
SINGLE REGULATOR FUEL SYSTEM
Reference numbers 1 through 3 in the block diagrams above
are fuel lines supplied by customer.
Reference number 4 is the engine generator set.
1108-20
Page 4
60706-148
Page 7
Below is a table of the fuel pressure readings at each reference in
the system.
Fuel Pressure Table
Single Regulator (L.P. Vapor only)
123
UNIT OFFTANK PSI7-11 in7-11 in
4-6 oz4-6 oz
STARTINGTANK PSI7-11 in7-11 in
4-6 oz4-6 oz
NO LOADTANK PSI7-11 in7-11 in
4-6 oz 4-6 oz
FULL LOADTANK PSI7-11 in7-11 in
4-6 oz4-6 oz
Two (2) Regulator System (L.P. Vapor only)
1234
UNIT OFFTANK PSI 10-15 lbs7-11 in7-11 in
4-6 oz4-6oz
STARTINGTANK PSI 10-15 lbs7-11 in7-11 in
4-6 oz4-6 oz
NO LOADTANK PSI 10-15 lbs7-11 in7-11 in
4-6 oz4-6 oz
FULL LOAD TANK PSI 10-15 lbs7-11 in7-11 in
4-6 oz4-6 oz
LUBRICATION
Before starting the engine, check the oil level in the crankcase. If
it is low, refill to the full mark with the proper weight/grade of oil as
recommended by the engine manufacturer’s maintenance
instructions. The necessity of using the correct oil, and keeping
the crankcase full cannot be over emphasized. Failure to use the
proper oil and keep the crankcase properly filled will cause
excessive engine wear and shorten its useful life.
COOLANT
Before starting the engine, check the coolant level in radiator. If it
is low, refill as specified in the engine manufacturer’s maintenance instructions. The radiator should be filled to about 1 inch
below the filler neck. For additional information on engine coolant
requirements see engine manufacturer’s maintenance instructions.
INSTALLING THE BATTERY
**** CAUTION ****
EQUIPMENT DAMAGE - In the following battery installation
procedure, check to be sure the selector switch remains in the
“stop” position.
Natural Gas
134
UNIT OFFLINE PSI7-11 in7-11 in
4-6 oz4-6 oz
STARTINGLINE PSI7-11 in7-11 in
4-6 oz4-6 oz
NO LOADLINE PSI7-11 in 7-11 in
4-6 oz4-6 oz
FULL LOADLINE PSI7-11 in.7-11 in
4-6 oz4-6 oz
Notice the preceding tables give two (2) different units of
measuring fuel pressure. The first is with a pressure gauge
calibrated in ounces per square inch. The second and most
accurate is the use of a simple water manometer. A manometer
is calibrated in inches of water column.
LP LIQUID WITHDRAWAL SYSTEMS
When installing a unit equipped the LP liquid withdrawal a
primary regulator is not required on the supply tank. The supply
line is connected to a liquid withdrawal valve on the supply tank
and run directly to the fuellock strainer mounted on the engine
generator set. Normally a 3/8 inch copper line is acceptable for
this type of fuel installation. You must be sure that the valve you
have connected to on the supply tank is in fact a liquid supply
valve and has a drop tube inside the tank that is pulling fuel from
the bottom of the supply tank. Before starting the unit you must
confirm that you have a good liquid supply at the unit. Engine
generators sets equipped for liquid withdrawal will not run
properly when supplied with high pressure vapor fuel.
A customer supplied twelve-volt BCI group 24 battery rated 650
CCA (minimum) is required to complete the installation. Install
the highest CCA rated battery available for best cold weather
starting performance.
****WARNING*****
EQUIPMENT DAMAGE - Always connect the positive battery
cable first and the negative cable last. When disconnecting a
battery always disconnect the negative cable first and the
positive cable last. Failure to follow these steps can cause
arcing at the battery post which can cause damage to both the
engine and the engine control module.
Observe polarities: Connect the positive (+) battery terminal to
the (+) cable from the control panel; the negative (-) battery
terminal is connected to the negative cable (ground) from the
engine generator assembly.
NOTE: Alway make sure that a new battery is fully charged
before installing it on a generator set. Failure to do so can cause
damage to the engine control module in the generator set.
All connections must be clean and tight. Check the electrolyte
(fluid) in the battery periodically to be sure it is above the plates.
Never allow the battery to remain in a discharged condition.
60706-148
Page 5
1108-20
Page 8
CONNECTING THE BATTERY CHARGER &
BLOCKHEATER
A two-stage battery tender is provided on all PSS series generators. This battery tender charges at a rate of 750 mA until the
battery is fully charged and then automatically switches to a 13.2
VDC float charger. The charger has an indicator light on it, red
indicates it is charging, and green indicates it is in the storage
mode (float charge). This charger is mounted on the engine
generator set just below the engine control panel.
** NOTICE **
The trickle charger is not intended to recharge a battery which
has become completely discharged. It is designed to produce
just enough current to maintain a fully charged battery.
This battery tender requires a circuit breaker protected AC circuit
from your distribution panel be run out to the engine generator
set. These AC wires can be run in the same conduit as the other
AC leads from the generator. It is suggested that this circuit be
fused for 15 amps, then both the battery charger and the block
heater can be connected to the same circuit. A 120 volt duplex
receptacle is mounted on the generator just below the engine
control panel, the battery tender is shipped already plugged into
the receptacle.
The engine frost plug heater has been prewired with a 120 volt
plug which can be plugged into the other side of the duplex
receptacle after wiring 120 volt power feed to the receptacle. The
frost plug heater has been prewired through a temperature
sensor which will turn the heater on when the air temperature
drops to 22 degrees F. and off when the air temperature reaches
30 Degrees F.
MOUNTING THE AUTOMATIC TRANSFER SWITCH
(Winco Non-UL only)
PSS40LS - The Automatic Transfer Switch typically shipped with
the PSS40LS system has a 230 Amp line side contactor installed
to handle your normal power needs and a 150 Amp generator
side contactor (230 Amp for single phase) to handle the emergency generator output. Before installing the A.T.S. you must
first ensure that the 230 Amp line side contactor will be sufficient
to handle your complete service. See Figure 5. (i.e. the main line
breaker must not be larger than 230 Amps) If you have 250, 300
Amp or larger system, you will not be able to transfer the complete electrical system. In this case it will be necessary to install
a secondary emergency distribution panel or purchase a larger
transfer switch.
*************
***** WARNING *****
*************
PERSONAL INJURY - Be certain the operation selector switch
on the front of the A.T.S. Control is in the “stop” position and the
main power switch “off”. For your own protection, verify these
important safety precautions yourself with reliable instruments
before proceeding.
A.C. ELECTRICAL CONNECTIONS
Single Phase
The standby generator terminals in the A.T.S are marked
“GENERATOR - G1, G-N, G3”. The “hot” leads G1 and G3 wire
directly to the top lugs on the generator side contactor, terminals
G1 and G3. The G-N connection is made to the lug on the
standoff just to the right of the generator side contactor.
The line terminals in the A.T.S. are marked “LINE - L1, L-N, L3”.
The “hot” leads L1 and L3 will wire directly to the top lugs on the
line side contactor. The L-N connection will be made on the
stand-off just to the left of the line side contactor.
The automatic transfer switch (A.T.S.) connects the load (lights,
furnace, outlets, etc.) to the normal power line. When normal
power fails, the A.T.S. starts the engine generator set, disconnects the power line and then connects the load to the standby
generator set. When normal power is restored, the automatic
switch retransfers the electrical load to the normal service and
stops the engine. The A.T.S. panel should be mounted as close
to the distribution panel as possible.
*************
***** WARNING *****
*************
FIRE HAZARD - All wiring must be done by a licensed electrician, and must conform to the national electrical code and comply
with all state and local codes and regulations. Check with the
local authorities before proceeding!
PSS27LS - The Automatic Transfer Switch typically shipped with
the PSS27LS system has a 230 Amp line side contactor installed
to handle your normal power needs and a 150 Amp generator
side contactor to handle the emergency generator output. Before
installing the A.T.S. you must first ensure that the 230 Amp line
side contactor will be sufficient to handle your complete service.
See Figure 5. (i.e. the main line breaker must not be larger than
230 Amps) If you have 250, 300 Amp or larger system, you will
not be able to transfer the complete electrical system. In this
case it will be necessary to install a secondary emergency
distribution panel or purchase a larger transfer switch.
1108-20
Page 6
The load terminals in the A.T.S. are marked “LOAD - T1, T-N,
T3”. The “hot” leads T1 and T3 will wire directly to the lower lugs
on the line side contactor. Jumper leads have already been
installed between the lower lugs on the line side and the lower
lugs on the generator side contactors. The T-N connection will
be made on the stand-off just to the left of the contactor.
An equipment grounding lug is provided just above the
T-N connection for your use in grounding the transfer switch.
Three Phase
The standby generator terminals in the A.T.S. are marked
“GENERATOR - G1, G2, G3 and G-N. The “hot” leads G1 G2
and G3 wire directly to the generator side contactor, terminals
G1, G2 and G3. The G-N connection is made to the lug on the
standoff just to the right of the generator side contactor.
The line terminals in the A.T.S. are marked “LINE - L1, L2, L3 and
L-N”. The “hot” leads L1, L2 and L3 will wire directly to the top
lugs on the line side contactor. The L-N connection will be made
on the standoff just to the left of the contactor.
The load terminals in the A.T.S. are marked “LOAD - T1, T2, T3
and T-N”. The “hot” leads T1, T2 and T3 will wire directly to the
60706-148
Page 9
FIGURE 5
The load current carrying wires (L) and (T) must be sized to
handle the maximum load current without excessive voltage drop.
By code, the wire must be heavy enough to handle the full current
rating of the main line circuit-breaker (or fuse) in the entrance (or
sub-panel) protecting the contactor switch.
Service
Entrance
Three phase unit shown, for single phase
wiring disregard L-2, T-2, G-2.
lower lugs on the line side contactor. Jumper leads have already
been installed between the lower lugs on the line side and the
lower lugs on the generator side contactors. The T-N connection
will be made on the standoff just to the left of the contactor.
An equipment grounding lug is provided just above the
T-N connection for your use in grounding the transfer switch.
All the neutral leads (G-N, L-N and T-N) must be carried through
the A.T.S. These leads are all bonded together within the A.T.S.
and are bonded to GROUND at one common point. If your
system requires an isolated neutral, this neutral to ground bond
can be isolated by removing the copper strap located between
the LINE terminal L-N and the ground lug in the panel. This
action, along with lifting the Neutral to Ground bond in the
generator connection cabinet, will effectively change this unit to a
fully isolated neutral system.
A fused disconnect (circuit breaker or fuses) must be
installed between the engine generator and the A.T.S. panel.
Failure to install a proper fused disconnect will void any
warranty on the generator end. All wiring from the enginegenerator to the transfer switch must be of sufficient size to
handle the appropriate fused disconnect amperage.
All wires should be installed in rigid or flexible conduit. (Knockouts are provided in the control box).
Because of the many different types of service, feeder, and
distribution equipment, no specific wiring instructions can be
provided. It is recommended that only copper wire be used. In
all cases it is essential that while the load is connected to the
generator, there can be absolutely no feedback from the
generator to the power line or the power line to the generator.
When properly installed, the normal A.T.S. Control and safety
systems will eliminate all paths for feedback.
To wire the automatic transfer switch into the existing wiring, first
determine which circuits will be on the emergency load circuit. If
the entire load is to be transferred, the transfer switch can be
wired in directly after the watt-hour meter and the service
entrance, providing the service entrance ampere rating is within
the transfer switch’s rated capability.
If only specific circuits are to be powered under emergency power
failure conditions, an additional distribution panel designated
“emergency distribution panel” must be installed.
All selected emergency circuits are removed from main distribution panels and installed in the emergency distribution panel. The
A.T.S. is then installed between the main panel and the emergency distribution panel. Suggested circuits: freezer, refrigerator,
furnace, emergency lights, sump pump, emergency outlet circuits,
etc. Total running load must not exceed generator rating.
D.C. ELECTRICAL INTERCONNECTION
PSS27LS and PSS40LS
Two control wires are required between the A.T.S. panel and the
generator control terminal box. Depending on the distance, 14 to
16 gauge stranded wire should be used. These wires will be
labeled S1 and S23.
The generator output leads in the generator connection box
follow the same marking pattern. i.e. G1, G-N and G3 on the
single phase and G1, G2, G3 and G-N on the three phase units.
*************
***** WARNING *****
*************
EQUIPMENT DAMAGE - When installing a Three Phase 240 volt
system be sure you know which lead is the high voltage "wild" leg
(208Volt line to neutral). The generator normally carries the high
voltage on the G3 lead.
60706-148
*************
***** WARNING *****
*************
Be sure both the mode switch on the Engine Generator and the
mode switch in the Automatic Transfer Switch are in the "OFF"
postition before you make any DC interconnections.
Page 7
1108-20
Page 10
The connections to the engine control will be made in a 2" X 4"
connection box mounted on the back side of the generator control
box just above the engine control. The wiring from the engine
control has already been stubbed into this connection box for
your convenience. The wires are labeled as follows:
The connections in the automatic transfer switch will be made on
a terminal block. This terminal block is located in the lower right
hand corner on the back wall of the switch. The terminals are
labeled S1, and S23.
These control wires MUST NOT be run in the same conduit as
the AC power leads coming from the generator or the 120 volt
circuit for the battery charger and block heater.
*************
***** WARNING *****
*************
EQUIPMENT DAMAGE - DC connections between Winco engine
generators and other makes of Automatic Transfer Switches will
vary. The Winco engine generator sets require a relay closure
between Battery Negative (wire S1) and Start ( wire S23) to
operate. The Battery Positive is not used in the A.T.S. panels.
Connecting Battery Positive in any switch can cause permanent
damage to the engine control module.
WINCO UL AUTOMATIC TRANSFER SWITCHES
If you are installing a UL transfer switch, there are a couple of
terminal identification changes you will have to watch for, otherwise they basically wire up the same.
The DC terminal block in the UL switch is labeled 11 & 12. Wire
S1 will connect to terminal #11 and S23 will connect to terminal
#12.
The normal power line connection points in the UL-ATS are
labeled N1, N2 for single phase and N3 is add for three phase.
The generator connection points in the UL-ATS are labeled E1 &
E2 for single phase and E3 is added for three phase. When
wiring single phase from the generator to the UL-ATS, G1
connects to E1 and G3 connects to E2.
There is no neutral connection point in these switches so all three
neutral leads (line neutral, generator neutral and load neutral)
should be connected together and taped up. See the prints
enclosed with UL-ATS panel for additional information.
*************
***** WARNING *****
*************
EQUIPMENT DAMAGE - The UL-ATS panels are voltage
sensitive. Do not attempt to use a 240 volt ATS on a 208 volt
system. Doing so will cause damage to the control circuits in the
ATS panel. Contact the factory if you have any concerns or
questions.
INITIAL START UP
*************
***** WARNING *****
*************
EQUIPMENT DAMAGE - DO NOT jump start these engine
generator sets. Starting these units on a low battery or jump
starting them will cause damage to the engine control module.
Use the following check list to verify correct installation before
starting the engine:
1.Engine oil. Fill as required with proper grade/qty.
2.Engine coolant. Fill as required with proper
mixture.
3.Unit mounting base properly bolted down.
4.Clearance for service and maintenance on all
sides.
5.Proper fuel line material and size.
6.All fuel line connections tight.
7.Fuel line protected and a moisture trap installed
(may be required for N.G.).
8.Correct LP/NG pressure 4-6 Oz. (7-11" Wc).
9.Battery connections clean and tight.
10.Battery fully charged.
11.All A.C. and D.C. wiring installed and properly
protected.
After completing the above checklist, the engine-generator
set is ready for the initial start-up test.
PROCEDURE
Move the selector switch on the engine generator to the “RUN”
position. The engine-generator will crank and start automatically. If the engine fails to start, return selector switch to the
“stop” position and correct the trouble before proceeding.
With the engine running smoothly check the no load voltage and
frequency at meters on the front panel. The voltage should be
208/240/480 A.C. depending on which model you have and a
frequency of 59.5 To 60.5 hertz (Hz). If you have the proper
voltage at the generator the next step is to check the voltage at
the generator terminals in the Automatic Transfer Switch. The
voltage between the G1 and the G3 terminals should be the same
as it was on the generator front panel. The voltage should also
be checked between the hot terminals (G1 and G3) and the G-N
to be certain of a balanced voltage output and a solid neutral
connection. The voltage between G1 and G-N should be about
120 volts AC (277 on 480 units). The same approximate voltage
should be found between terminals G3 and G-N (120 volts AC).
On three phase panels the G2 voltage level should also be
checked. ON 240 VOLT (DELTA) SYSTEMS BE SURE YOU
KNOW WHERE THE HIGH VOLTAGE "WILD" LEG IS. IT
MUST BE IN THE SAME LOCATION ON THE LINE SIDE AS IT
IS ON THE GENERATOR SIDE. (i.e. if it's on L-3 on the line side
it must be on G-3 on the generator side.
1108-20
Page 8
60706-148
Page 11
** Notice **
If for any reason during the check out procedure the voltage and
frequency are not correct, turn the selector switch to the “STOP”
position and correct the trouble before proceeding.
After verifying the that voltage and frequency are correct, turn the
selector switch to the “STOP” position. The unit should shut off
with no time delay. You are now ready to test the automatic start
function.
Move the selector switch on the engine generator set to the
“AUTO” position. Next move the selector switch on the A.T.S.
panel to the “START” position. The unit will go into a 3 second
start delay and then start up. If it fails to start at this time, the DC
interconnection wiring is incorrect. Now when the selector switch
on the A.T.S. is moved to the “DISABLE” position the unit will go
into a 3 minute cool down and then shut off. As long as line
power is still applied to the transfer switch during this test period
the A.T.S. will not transfer the load to the generator.
Next you need to test the complete system. To accomplish this
you will have to fail the incoming line power to the A.T.S. panel.
First move both selector switches to the automatic position. Then
fail the incoming power. All the loads connected to the A.T.S.
should now be dead. The engine generator set will go into a 3
second start delay. At the end of the start delay the unit will start
up. As soon as the engine generator set reaches operating
speed the generator side contactor will close and the load will be
applied to the engine generator.
5.Position the top right hand (RUN) slide switch to the center
position. The correct time and date should now be displayed.
Setting the Exerciser Program:
NOTE: The programs on this clock are grouped. i.e. 1 and 2, 3
and 4, etc. The start time is programmed on the odd number and
the stop time is programmed on the even number in each
program set.
1.Position the top right hand (RUN) slide switch to the right
hand position.
2.Position the top left hand (AUTO) slide switch to the center
position.
3.Press the "Program Select Button" until No 1 is displayed on
the clock to the right of the time.
4.Push the "Day Select Button" to select the day you want the
engine generator set to start up and run. Note: You can get
more than one triangle displayed on the clock. If this happens just
keep pressing the button and it will work back through the cycle
and display only one triangle under whichever day you desire.
5.With the "Hour" and "Minute" buttons select the time of day
you want the engine to start up.
6.Press the "Program Select Button" until number 2 is displayed on the clock.
Restoring the line power will cause the generator side contactor
in the A.T.S. to open and the line side to close as soon as the
generator side is open. This sequence is controlled by the
electrical and mechanical interlocks in between the two contactors in the A.T.S. panel. These interlocks ensure that you get a
clean 'break before make' action in the transfer switch.
The restoration of line power also sends a stop signal to the
engine generator set. This stop signal will activate the 3 minute
timer circuit and shut down the unit 3 minutes later.
This completes your installation and unit testing. ALWAYS leave
the system in standby mode unless servicing the unit. For
standby operation, keep both the generator set and transfer
selector switches in the “AUTOMATIC” position.
SETTING THE EXERCISER CLOCK
Setting the current time and date.
1.Position the top right hand (RUN) slide switch to the left
position.
2.Push the clock's "Day Select Button" until the clock displays
a triangle under the number corresponding to the current day of
the week. (Monday is day 1, Sunday is day 7)
3.Push the "Hour Select Button" until the display indicates the
correct hour. Note: For PM be sure there is a "P" displayed
beside the correct hour.
4.Push the "Minute Select Button" until the display indicates
the correct time in minutes.
7.Push the "Day Select Button" to select the day you want the
engine to stop. This must be the same day you selected in step
4 above.
8.With the "Hour" and "Minute" buttons, select the time you
want the engine to stop. It is recommended you let the engine
run at least 15 minutes during any exercise period.
9.Position the top right hand (RUN) slide switch to the center
(RUN) position.
CLOCK NOTES:
This seven day exerciser clock has seven additional program
cycles available. Always keep in mind the odd number turns the
unit on and the even number shuts the unit off. (i.e. (3 on, 4 off)
(5 on, 6 off) etc.
The relay in the clock will not work unless the transfer switch is
installed and powered up. The clock relay needs 120 volts AC to
operate.
If, when you finish programming the clock, you get an EEEE on
the display, it stands for error. The most common error is that the
day of operation has not been properly set at each step or a
program has been turned on and not turned off. i.e. programs not
properly grouped 1& 2, 3 & 4, 5 & 6, etc.
On the face of the clock is a small button marked "R". This is a
reset switch. Depressing this switch will remove all programming
in the clock including the time. Use a small screwdriver or the tip
of a pencil to depress this button. This should be used only as a
last resort.
60706-148
Page 9
1108-20
Page 12
TROUBLESHOOTING TABLES
UNIT WILL NOT CRANK WHEN THE POWER FAILS.
1.Generator control switch not in "AUTOMATIC"
position.
2.Transfer control switch not in "AUTOMATIC"
position.
3.Incorrect wiring between transfer switch and
generator.
4.Defective start stop relay in the transfer
switch.
5.Circuit breaker tripped on engine control.
6.Defective engine control module.
7.Loose or dirty battery terminals.
8.Defective "Run/Auto" switch on generator or
transfer switch.
9.Defective starter.
10.Defective start solenoid.
ENGINE WILL NOT COME UP TO SPEED AFTER IT
STARTS
1.Insufficient fuel volume getting to the unit.
a.Too small of fuel line.
b.Fuel pressure too low/high.
2.Fuel load block needs to be adjusted.
3.Governor is defective.
4.AC short in generator components.
ATS PANEL WILL NOT TRANSFER TO EMERGENCY
SUPPLY (GENERATOR)
1.No AC generator output from generator.
2.Broken or defective mechanical/electrical
interlocks.
3.Defective holding coil in the generator side
contactor.
4.Wiring error between generator and transfer
switch.
5.Defective start/stop relay
ENGINE WILL NOT CRANK WITH GENERATOR
SELECTOR SWITCH IN THE RUN POSITION.
1.Battery dead.
2.DC circuit breaker on control panel tripped.
3.Defective engine controller.
4.Loose or dirty battery terminals.
5.Defective "Run/Auto" switch on generator.
6.Defective starter.
7.Defective start solenoid.
8.Locked up engine genset.
ENGINE CRANKS BUT WILL NOT START
1.Improper fuel pressure being delivered to
unit.
2.Fuel supply shut off.
3.Fuel tank empty.
4.Defective spark plug.
5.Defective engine ignition module.
6.Dirty air cleaner filter.
7.Defective fuel solenoid valve.
8.Low battery.
9.Defective fuel regulator
ENGINE STARTS AND THEN STOPS AND FAULT LIGHT
COMES ON
1.Engine is low on oil.
2.Engine has high water temperature.
3.Engine has oversped.
4.Engine has gone into overcrank.
5.No output from engine alternator to engage
stop crank circuit.
ATS PANEL WILL NOT RETRANSFER TO NORMAL
POWER
1.Proper normal line power not available at line
terminals in ATS panel.
2.Defective holding coil in line side contactor.
3.Broken or defective mechanical/electrical
interlocks.
4.Defective start/stop relay
NO AC OUTPUT FROM GENERATOR
1.Defective diode.
2.Defective voltage regulator.
3.Defective rotor.
4.Defective stator.
5.Defective exciter rotor.
6.Defective exciter stator.
7.AC short in the output leads.
8.Defective field circuit breaker.
NG/ LP CONVERSION
**** CAUTION ****
EQUIPMENT DAMAGE - Do not make any fuel adjustments or
governor adjustments until all pressure readings are in compliance with specification. See fuel pressure charts (tables 1, 2,
and 3).
The engine generator sets covered in this manual are shipped for
a specific fuel, either Liquid Propane (LP) vapor or Natural Gas
(NG). If it should be necessary to change the type of fuel used
after a unit is received, the following procedures are provided.
NOTE: For conversion to/from liquid withdrawal LP consult the
factory. Additional parts will be required for this conversion.
1108-20
Page 10
60706-148
Page 13
NATURAL GAS TO PROPANE VAPOR
1.Turn off fuel supply.
2.Remove the fuel line from the carburetor at the demand
regulator.
3.Remove the cap on the upright column of the regulator. This
will expose the pressure spring adjusting screw. Back off the
spring adjusting screw so there is just enough room to replace
the cover. Replace the cover.
4.Invert the regulator so it is positioned with the column
pointing down.
7. If the pressure is correct, remove the meter and reinstall the
pipe plug. Next remove the 1/8 inch NPT plug on the carburetor
side of the regulator and install the pressure meter. Move the
generator switch to the run position. As soon as the solenoid
opens the pressure should rise to 2.5 to 3 oz. just as the engine
starts to crank. If it is within this range replace the cap on the
column. If not, adjust the screw down to increase and up to
decrease and retest.
8.Next the timing on the engine must be changed. As this unit
was shipped to operate on LP the timing advance was set at 26
degrees. For operation on NG it will be necessary for you to
reset the timing advance to 36 degrees.
5.Reconnect the fuel line at the regulator.
6.Remove the 1/8 NPT plug (the one closest to fuel solenoid)
located on what is now the top of the regulator. Connect a fuel
pressure meter or a manometer where the plug has been
removed. Move the generator control switch to the run position.
As the unit starts to crank the fuel solenoid will open and you
should get a pressure reading of between 4 to 6 ounces (7 to 11
inches of water column).
7. If the pressure is correct, remove the meter and reinstall the
pipe plug.
8.Next the timing on the engine must be changed. As this unit
was shipped to operate on NG the timing advance was set at 36
degrees. For operation on LP it will be necessary for you to reset
the timing advance to 26 degrees.
9.You are now ready to make the final fuel mixture adjustment.
These engines were adjusted at the factory to produce about .7 to
3.4% CO. If you have the ability to test the CO, adjust the
mixture on the carburetor until you achieve the proper CO
reading. If you don't have a CO meter follow the manual adjustment procedure later in this section.
PROPANE VAPOR TO NATURAL GAS
1.Turn off fuel supply.
2.Remove the fuel line from the carburetor at the demand
regulator.
9.You are now ready to make the final fuel mixture adjustment.
These engines were adjusted at the factory to produce a .7 to
3.4% CO. If you have the ability to test the CO, adjust the
mixture on the carburetor until you achieve the proper CO
reading. If you don't have a CO meter follow the manual adjustment procedure later in this section.
Manual Fuel Mixture Adjustment Procedure
1.Ensure the unit is operating under an 80 to 100% load or at
the highest anticipated load.
2.Attach a frequency meter to monitor Hz.
Note: On these units the mixture adjustment is located on the
carburetor just behind the fuel inlet hose. This mixture adjustment is a partial turn, lean to rich, load block.
3.If you are adjusting from LP to NG you will have to richen the
adjustment and if you are going from NG to LP you will have to
lean out the adjustment.
4.Begin making your appropriate mixture adjustment, observing the Hz meter. If the meter begins to drop you have the mixture
set too lean or too rich. Adjust the valve in the opposite direction.
Adjustments should be made very slowly. Adjust back and forth
until the steady 60Hz reading is achieved with mixture set as lean
as possible.
3.Invert the regulator so the column is in the upright position.
4.Remove the cap on the upright column of the regulator. This
will expose the pressure spring adjusting screw. Turn the screw
all the way out (CCW) and then back in (CW) about 8 turns. The
plug should be approximately half way down for initial starting.
5.Reconnect the fuel line at the regulator.
6.Remove the 1/8 NPT plug (the one closest to fuel solenoid)
located on what is now the bottom of the regulator. Connect a fuel
pressure meter or a manometer where the plug has been
removed. Move the generator control switch to the "run" position.
As the unit starts to crank the fuel solenoid will open and you
should get a pressure reading of between 4 to 6 ounces (7 to 11
inches of water column).
60706-148
Page 11
1108-20
Page 14
CONTROL PANEL WIRING THREE PHASE
CONTROL PANEL WIRING SINGLE PHASE
1108-20
Page 12
60706-148
Page 15
CONTROL PANEL
60706-148
Page 13
1108-20
Page 16
THREE PHASE-HIGH WYE
277/480 VOLTS
HIGH AND LOW WYE
THREE PHASE AC WIRING
THREE PHASE-LOW WYE
120/208 VOLTS
1108-20
Page 14
60706-148
Page 17
THREE PHASE -DELTA
120/240 VOLTS
SINGLE PHASE
120/240 VOLTS
60706-148
THREE PHASE AC WIRING - DELTA
SINGLE PHASE AC WIRING
Page 15
1108-20
Page 18
VOLTAGE REGULATOR WIRING
THREE PHASE AND SINGLE PHASE
1108-20
CONTROL PANEL WIRING
THREE PHASE AND SINGLE PHASE
THREE
SINGLE
PHASE
PHASE
Page 16
60706-148
Page 19
DC SCHEMATIC
60706-148
Page 17
1108-20
Page 20
Three Phase
120/240 Volt
120/240 Volts
Single Phase
27 KW INTERNAL GENERATION CONNECTIONS
1108-20
Three Phase
277/480 Volt
Page 18
Three Phase
120/208 Volt
60706-148
Page 21
120/208 Volt
Three Phase
277/480 Volt
Three Phase
40 KW INTERNAL GENERATION CONNECTIONS
60706-148
Single Phase
120/240 Volts
Page 19
120/240 Volt
Three Phase
1108-20
Page 22
PSS40LS
OUTLINE
DRAWING
AND WIRING
ENTRANCE
1108-20
Page 20
60706-148
Page 23
PSS27LS
OUTLINE
DRAWING
AND WIRING
ENTRANCE
60706-148
Page 21
1108-20
Page 24
12 MONTH LIMITED W ARRANTY
WINCO, Incorporated warrants to the original purchaser for 12 months that goods manufactured or
supplied by it will be free from defects in workmanship and material, provided such goods are installed,
operated and maintained in accordance with WINCO written instructions.
WINCO’s sole liability, and Purchaser’s sole remedy for a failure under this warranty, shall be limited to
the repair of the product. At WINCO’s option, material found to be defective in material or workmanship
under normal use and service will be repaired or replaced. For warranty service, return the product within
12 months from the date of purchase, transportation charges prepaid, to your nearest WINCO Authorized
Service Center or to WINCO, Inc. at Le Center Minnesota.
THERE IS NO OTHER EXPRESS WARRANTY.
To the extent permitted by law, any and all warranties, including those of merchantability and fitness for a
particular purpose, are limited to 12 months from date of purchase. In no event is WINCO liable for
incidental or consequential damages.
Note: Some states do not allow limitation on the duration of implied warranty and some states do not
allow the exclusion or limitation of incidental or consequential damages, so the above limitations may not
apply in every instance. This warranty gives you specific legal rights which may vary from state to state.
WINCO reserves the right to change or improve its products without incurring any obligations to make
such changes or improvement on products purchased previously.
EXCLUSIONS:
WINCO does not warrant engines, batteries, or other component parts that are warranted by their re-
spective manufacturers.
WINCO does not warrant modifications or alterations which were not made by WINCO, Inc.
WINCO does not warrant products which have been subjected to misuse and/or negligence or have
been involved in an accident.