Winco 50PTOC4-03/1, 50PTOC4-04/1, 50PTOT4-03/1, 50PTOT4-17/1, 50PTOC4-18/1 Installation And Operator's Manual

...
50kW-55kW
PTO GENERATORS
INSTALLATION AND
OPERATORS
WINCO INC. 225 S. CORDOVA AVE. LE CENTER, MN 56057 507-357-6821
MANUAL
SERVICE DEPT. 507-357-6831
www.wincogen.com
TABLE OF CONTENTS
SAVE THESE INSTRUCTIONS 2 TESTING POLICY 2 SPECIFICATIONS 3
50PTOC4-03/1 50PTOT4-03/1 50PTOC4-04/1 50PTOT4-04/1 50PTOC4-17/1 50PTOT4-17/1 50PTOC4-18/1 50PTOT4-18/1
SAFETY 4
IMPORTANT SAFETY INSTRUCTIONS CALIFORNIA PROPOSITION 65 ANSI SAFETY DEFINITIONS
PREPARING THE UNIT 5
UNPACKING
SAVE THESE INSTRUCTIONS
This manual contains important instructions that should be followed during installation and maintenance of the generator. Read and understand all instructions in the manual before starting and operating the generator.
USING THIS MANUAL Congratulations on your choice of a WINCO generator. You have selected a high-quality, precision-engineered generator designed and tested to give you years of satisfactory service.
To get the best performance from your new generator, it is important that you carefully read and follow the operating instructions in this manual.
Should you experience a problem please follow the “Troubleshooting Tables” near the end of this manual. The warranty listed in the manual describes what you can expect from WINCO should you need service assistance in the future.
INTRODUCTION 5 INSTALLATION 5
FOUNDATION MOUNTING TRAILER MOUNTING
ELECTRICAL CONNECTIONS 6
GROUNDING THREE-POINT HITCH KIT PLUG KIT
OPERATION 9 PRE-START CHECKS 9 GENERATOR PROCEDURES 10
START-UP SHUTDOWN
MAINTENANCE 11
GENERAL INFORMATION PERIODICAL MAINTENANCE LUBRICATION CLEANING & INSPECTION GENERATOR STORAGE
TROUBLE SHOOTING TABLE 13 WIRING DIAGRAM 14
COPY YOUR MODEL AND SERIAL NUMBER HERE No other WINCO generator has the same serial number as yours. If you should ever need to contact us concerning this unit, it will help us to respond to your needs faster.
MODEL __________________________________________________
SERIAL NUMBER _________________________________________
PURCHASE DATE _________________________________________
DEALER NAME ___________________________________________
DEALER PHONE # ________________________________________
TESTING POLICY
Before any generator is shipped from the factory, it is fully checked for performance. The generator is loaded, and the voltage, current, and frequency are carefully checked.
WIRING DIAGRAM 15 36 MONTH LIMITED WARRANTY 16
OPM-137
Rated output of generator is based on engineering tests of typical units, and is subject to, and limited by, the temperature, altitude, fuel, and
other conditions specied by the manufacturer of applicable engines.
2
REV A
SPECIFICATIONS
50PTOC4-03/1
Watts 50,000 Volts 120/240 Phase Single Amps 208 Input Speed 540 RPM Generator Speed 1800 RPM AVR AS440 Input Shaft 1 3/8” 6-spline Required Tractor PTO HP 100 Gear Lube Volume 0.875 Pint Type SAE 80-90W-140
50PTOT4-03/1
Watts 50,000 Volts 120/240 Phase Single Amps 208 Input Speed 1000 RPM Generator Speed 1800 RPM AVR AS440 Input Shaft 1 3/8” 6-spline Required Tractor PTO HP 100 Gear Lube Volume 0.875 Pint Type SAE 80-90W-140
50PTOC4-17/1
Watts 50,000 Volts 120/240 Phase Three Amps 120 Input Speed 540 RPM Generator Speed 1800 RPM AVR AS440 Input Shaft 1 3/8” 6-spline Required Tractor PTO HP 100 Gear Lube Volume 0.875 Pint Type SAE 80-90W-140
50PTOT4-17/1
Watts 50,000 Volts 120/240 Phase Three Amps 120 Input Speed 1000 RPM Generator Speed 1800 RPM AVR AS440 Input Shaft 1 3/8” 6-spline Required Tractor PTO HP 100 Gear Lube Volume 0.875 Pint Type SAE 80-90W-140
50PTOC4-04/1
Watts 50,000 Volts 120/208 Phase Three Amps 138 Input Speed 540 RPM Generator Speed 1800 RPM AVR AS440 Input Shaft 1 3/8” 6-spline Required Tractor PTO HP 100 Gear Lube Volume 0.875 Pint Type SAE 80-90W-140
50PTOT4-04/1
Watts 50,000 Volts 120/208 Phase Three Amps 138 Input Speed 1000 RPM Generator Speed 1800 RPM AVR AS440 Input Shaft 1 3/8” 6-spline Required Tractor PTO HP 100 Gear Lube Volume 0.875 Pint Type SAE 80-90W-140
50PTOC4-18/1
Watts 55,000 Volts 277/480 Phase Three Amps 66 Input Speed 540 RPM Generator Speed 1800 RPM AVR AS440 Input Shaft 1 3/8” 6-spline Required Tractor PTO HP 110 Gear Lube Volume 0.875 Pint Type SAE 80-90W-140
50PTOT4-18/1
Watts 55,000 Volts 277/480 Phase Three Amps 66 Input Speed 1000 RPM Generator Speed 1800 RPM AVR AS440 Input Shaft 1 3/8” 6-spline Required Tractor PTO HP 110 Gear Lube Volume 0.875 Pint Type SAE 80-90W-140
3REV A
OPM-137
SAFETY
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS
This manual contains important information that should be understood and followed before the installation, operation and maintenance of the generator. Failure to follow the safety instructions in this manual could result in serious injury or death. Keep this manual available for future reference.
CALIFORNIA PROPOSITION 65
WARNING: This product contains crude oil, gasoline, diesel fuel and other petroleum products, Antifreeze to which can expose you to chemicals including toluene
and benzene, Ethylene glycol (ingested) which are known to the State of California to cause cancer, birth defects or other reproductive harm and developmental issues. For more information go to www.P65Warning.ca.gov.
3. NOISE HAZARD -
Excessive noise is not only tiring, but continual exposure can lead to loss of hearing.
A. Use hearing protection when working around this equipment for long periods of time. B. Keep your neighbors in mind when permanently installing this equipment.
4. CLEANLINESS -
Keep the generator and surrounding area clean.
A. Remove all grease, ice, snow or materials that create slippery conditions around the unit. B. Remove any rags or other materials that could create a
potential re hazard.
C. Carefully clean up any gas or oil spills before starting the unit.
5. SERVICING EQUIPMENT -
ANSI SAFETY DEFINITIONS
DANGER:
DANGER indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. This signal word is to be limited to the most extreme situations.
WARNING:
WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION:
CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. It may be used to alert against unsafe practices.
NOTE: CAUTION is also used on the unit labels and in this manual to indicate a situation that could result in serious damage or destruction of the equipment and possible personal injury.
1. ELECTRIC SHOCK -
The output voltage present in this equipment can cause a fatal electric shock. This equipment must be operated by a responsible person.
A. Do not allow anyone to operate the generator without proper instruction. B. Guard against electric shock. C. Avoid contact with live terminals or receptacles. D. Use extreme care if operating this unit in rain or snow. E. Use only three-prong grounded plugs and extension cords. F. Be sure the unit is properly grounded to an external ground rod driven into the earth.
2. FIRE HAZARD -
A. Keep a re extinguisher nearby and know its proper use. Fire
extinguishers rated ABC by NFPA are appropriate.
OPM-137
All service, including the installation or replacement of service parts,
should be performed only by a qualied technician.
A. Use only factory approved repair parts. B. Do not work on this equipment fatigued. C. Use extreme caution when working on electrical components. High output voltages from this equipment can cause serious injury or death. D. Installing a generator is not a “do-it-yourself” project. Consult
a qualied, licensed electrician or contractor. The installation
must comply with all national, state, and local codes.
6. INSTALLATION -
Installing a PTO generator is not a “do-it-yourself” project. Consult
a qualied, licensed electrician or contractor. The installation must
comply with all national, state, and local codes.
A. Never operate the PTO drive generator without having it properly mounted to a concrete base or approved trailer. b. Never connect the PTO generator to an existing electrical system without installing an isolation transfer switch. C. Always insure the drive shaft is straight and level before operating the generator.
8. OPERATION - PTO drive shafts (tumbling bars) have many inherent dangers, extreme caution must be exercised when using them.
A. NEVER allow children around the drive shaft when it is in operation. B. Keep all safety guards and shields in place and securely tightened. C. Never operate a drive shaft that has been damaged or had the safety shield removed. D. Never step over a drive shaft while it is running. E. Never wear a necktie, loose articles of clothing, or anything else that can be caught in moving parts. F. Never try to stop drive shaft with your hand or your foot.
4
REV A
PREPARING THE UNIT
INSTALLATION
UNPACKING
CAUTION: EQUIPMENT DAMAGE
When you unpack your new generator, be sure to remove all of the information sheets and manual from the carton.
1. As you receive your unit, it is critical to check it for any damage. If any damage is noted, it is always easiest to refuse the shipment and let WINCO take care of the freight claim. If you sign for the unit, the
transfer of the ownership requires that you le the freight claim
2. Before proceeding with the preparations of your new generator for operation, take a couple of minutes to ensure the unit you have
received is the correct model and review the specication pages in
this manual to ensure that this unit meets your job requirements.
INTRODUCTION
The WINCO power take-off generators are designed primarily for farm
use as a standby electrical power supply, utilizing the power take-off
of a tractor or truck as the prime mover. This PTO drive generator will provide, 120/240V 1-PH, 120/208V 3-PH, 120/240V 3-PH, 277/480V
3-PH, or 346/600V (depending on model), 60Hz electrical service when
properly driven.
DO NOT operate and/or store the unit outside during inclement weather without adequate protection from the elements. Failure to do so will damage the unit.
NOTE:
It is acceptable to use this generator with a tractor with less HP output than required for full power operation. The generator will work but produce only as much kW output as the tractor can supply HP for. For example, a 20 HP output tractor will deliver a maximum of approximately 10 kw.
FOUNDATION MOUNTING
Mount the generator on a foundation if it is to be used as a permanent or standby power source. When planning a foundation consider the following points:
A. The foundation location should enable aligning the drive shaft (tumbling bar) in a straight or nearly straight line between the power take-off and the generator input shaft. Misalignment must be less than 5 degrees during generator operation, even though the mechanical design of the tumbling bar would allow greater misalignment.
B. The foundation must be solid enough to absorb generator starting
and reected load torque during operation.
C. The foundation surface should be at.
D. Space is required around the generator for mounting switching devices, making connections, and for servicing.
E. For dimensions needed for install for your specic generator, please
refer to it’s outline drawing. The hardware needed is dependent on your distinct application.
F. The generator mounting bracket must rest evenly and rmly on the
foundation. Install shims if necessary to even out the foundation
under the mounting pads then bolt the generator rmly in place.
TRAILER MOUNTING
Optional
If you are using a tractor with more HP than required to run the generator care should be taken to ensure that you do not overload the generator causing overheating and equipment damage. Observe input
RPM specications.
The generator may be foundation mounted for use as standby power source, or trailer mounted, and used as portable electrical power sources for areas where commercial power is not readily available, such as out buildings.
This generator includes a frequency meter to warn against high or low frequency, three output power receptacles, an overload protection circuit, and an electronic excitation circuit. To reduce maintenance problems, the coupling between the generator input shaft and rotor consists of precision helical gearing rather than a chain link drive. The input shaft is a 1 3/8in. 6-spline.
IMPORTANT: THE MANUFACTURER STRONGLY RECOMMENDS RUNNING THE GENERATOR UNDER LOAD AT LEAST ONCE A MONTH IN ORDER TO EVAPORATE ANY ACCUMULATED MOISTURE CONDENSATION.
Mount the generator on a trailer if you plan to use it as a portable power source. When selecting or building a trailer to mount the generator, consider the following points:
A. The trailer construction must be strong enough to support the generator.
B. The design of the trailer must enable the trailer to remain stable during operation, and to resist tipping caused by generator starting
and reected load torque.
5REV A
OPM-137
Loading...