Wilo TWI, TWU Installation And Operating Instructions Manual

Wilo TWI & TWU 4” Submersible Well Pumps
Installation and operating instructions
50-18-002-0817
1 General Information
2.4 Safety precautions for the operator
1.1 Uses
1.2 Product Range
1.2.1 Rating Range
1.2.2 Technical Characteristics
• Temperature range: 38°F to 85°F
• Max. Flow rate: 115 GPM
• Max. immersion depth: 900 Ft.
• Maximum permissible sand content: 50 g/ml
• Pressure pipe connection: 1” to 2”, depending on size of pump
• Max. pump lift: to 1300 ft, depending on size of pump
1 Safety
2.0 Danger symbols used in these operating instructions
Safety precautions in these operating instructions which, if not followed, could cause personal injury are indicated by the symbol:
Existing regulations for the prevention of accidents must be followed. Dangers caused by electrical energy are to be excluded. Directives issued by the local electrical code and the local electricity supply companies are to be observed.
2.5 Safety information for inspection and assembly
The operator must ensure that all inspection and installation
work is carried out by authorised and qualied specialists who have carefully studied these instructions. Work on
the pump/machinery should only be carried out when the machine has been brought to a standstill.
2.6 Unauthorized modication and manufacture of spare parts
Alterations to the pump or installation may only be carried out with the manufacturer’s consent. The use of original spare parts and accessories authorised by the manufacturer will ensure safety. The use of any other parts may invalidate
claims invoking the liability of the manufacturer for any
consequences.
2.7 Unauthorized operating methods
The operating safety of the pump or installation supplied can only be guaranteed if it is used in accordance with paragraph 1 of the operating instructions. The limiting values given in the catalogue or data sheet must neither be
exceeded nor allowed to fall below those specied.
when warning of electric voltage with
The following symbol is used to indicate that by ignoring the relevant safety instructions, damage could be caused to the pump/machinery and its functions:
ATTENTION!
2.2 Staff Training
The personnel installing the pump must have the
appropriate qualications for this work.
2.3 Risks incurred by failure to comply with the safety precautions
Failure to comply with the safety precautions could result in personal injury or damage to the pump or installation. Failure to comply with the safety precautions could also invalidate any claims for damages.
In particular, lack of care may lead to problems such as:
• Failure of important pump or machinery functions,
• Personal injury due to electrical, mechanical and bacteriological causes.
• Damage to property.
3 Transport and interim storage
Upon delivery, please check that the device has survived the journey undamaged. If you nd any damage, the normal
routine measures are to be initiated with the shipping company.
ATTENTION!
During transport and in storage the pump must be protected against moisture, frost and mechanical damage. Store horizontally in shockproof places.
4 Product and accessory description
4.1 Pump
• Multistage submersible pump with radial or semi-axial impellers, depending on size of pump, for use in 3” & 4” bore- holes.
• With built-in check valve.
4.2 Motor
• Consult motor manufacturer’s documentation for more information.
2 50-18-002-0817
4.3 Accessories
5.3 Electrical Connection
Accessories must be ordered separately.
• Switching/controlling equipment (motor protection + pump control) assembly
• Float
• Shut-off valves
• Manometer
• Safety valve
• Dry-run
• Electrodes
• Float switch
• Motor cable as assembly (incl. plug)
• Heat-shrink cable connections
• Steel cable (stainless steel)
• Pressure vessel
• Cooling-shroud (stainless steel/PVC)
• Etc.
1 Assembly / Installation
The pump can be operated either vertically or horizontally (for horizontal position only with a cooling-shroud).
5.1 Assembly
ATTENTION!
• The bore-holes or pump stations must be created/ arranged in accordance with the generally applicable technical rules.
• Please ensure that the ow of water in the bore-hole or well is sufcient for the capacity of the pump.
• Ensure that the pump never runs dry and make sure that
even in dry periods the water level never falls below the
pump’s check valve (uppermost position).
In the case of installation in a deep well (well shaft diameter greater than a bore-hole), a reservoir, horizontal installation or in a deep well, a cooling-shroud (accessory) must be
tted to the unit to ensure the motor is properly cooled (g.
2, pos. A).
• It must be ensured that the well shaft in the bore-hole has a constant internal diameter to allow the pump to be lowered freely for the entire depth of the shaft.
• Never raise or lower the pump by the electric cable.
• The electrical connection and extension of the motor
cable must take place before the pump is lowered and be tested/measured to ensure they are working.
• The nal installation position must be guaranteed such
that the pump sits at least 1 foot above the bottom of
the bore-hole or well (g. 1).
• The rating plate must be afxed in the immediate vicinity
of the well head to allow access at all times to the unit’s technical data.
• Before lowering (and while lowering in deep bore-holes) the insulation resistance of
• The motor and cable must be measured several times (min. 2 M).
Electrical work must be carried out by a qualied contractor
strict compliance with local regulations.
The maximum cable length depends on the nominal motor current and the permissible drop in voltage over the entire cable length. Consult motor manufacturer’s documentation for more information.
A faulty electrical connection will result in damage to the motor.
6 Operation
6.1 Controlling the direction of rotation in 3-phase installations:
To determine the correct direction of rotation for the pump, only the shutoff pressure at the well head needs to be
checked, taking into account that the correct motor
direction of rotation generates the greater pressure.
• To rectify an incorrect direction of rotation swap any two phases in the switchbox or motor protection switch.
ATTENTION!
See motor manufacturer’s documentation for more information.
6.2 Operation
The pump must never run while dry, not even for brief periods.
7 Maintenance
Before carrying out any maintenance work, switch off the
pump and ensure that it cannot be switched on again by
unauthorized people. Never carry out work on a running
pump.
No special maintenance is required during normal operation.
7.1 Spare parts
ATTENTION!
Please contact Wilo Customer Service directly for spare parts, standard replacements or repairs to the hydraulic pump parts.
5.2 Hydraulic connections (see g. 1)
• Connections to pipes. 1” through 6” depending on size of pump. In the case of larger types (8” / 10”), the pump
is only connected directly to the pipework.
• It is recommended that a check valve be tted every
200 Feet to the surface of the borehole.
3Wilo TWI - Installation and Operation Manual