Willoughby Stainless Fountains WODF-1, WODF-2-CHD, WODF-2-PET, WODF-3-CHD-PET, WODF-2-HC Installation & Operation Manual

...
WODF-1
Installation &
Operation Manual
WODF Series
One-, Two-, and Three-station Outdoor Drinking Fountains
Table of Contents
Pre-Installation Information �������������������������������������3 Standard Fountain Congurations �������������������������� 4 Physical Dimensions ����������������������������������������������5 Rough-in Dimensions ���������������������������������������������6 Required Installation Supplies �������������������������������� 8
Parts List and Exploded-view Drawings ����������������� 9 Hardware Identication ����������������������������������������12
Installation Instructions ���������������������������������������������
Step 1: Fixture Installation �������������������������������13 Step 2: Adjusting Drinking Spout Flow �������������14
Care and Maintenance �����������������������������������������15
Troubleshooting ��������������������������������������������������������
WODF Drinking Fountain ���������������������������������16
Drawings �������������������������������������������������������������������
Physical Dimensions ����������������������������������������17 Rough-in Dimensions ���������������������������������������20 Push Button Details ������������������������������������������ 22 Freeze Resistant Valve Installation Details������� 23
Warranty ���������������������������������������������������������������26
Rev. 3/2018
Willoughby Stainless Fountains
5105 West 78th Street Indianapolis, IN 46268 Toll Free: (800) 428-4065 Local: (317) 875-0830
Fax: (317) 875-0837 www.willoughbystainlessfountains.com
Outdoor Drinking Fountains
WODF Series
(Page intentionally left blank)
Installation & Operation Manual
Willoughby Stainless Fountains
TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837
Page 2Rev. 3/2018 www.willoughbystainlessfountains.com
Outdoor Drinking Fountains
INSTALLATION INSTRUCTIONS
Installation notice!
INSTALLATION INSTRUCTIONS
Installation notice!
WODF Series
Installation & Operation Manual
Pre-Installation Information
Check Rough-In location PRIOR to installation
Flush lines thoroughly PRIOR to hook-up
When installing the Willoughby Stainless Fountains' WODF Series drinking fountain system:
Before step 1 of the installation instructions, ensure that rough-ins are in the correct location.
The valve assembly, including the spray head, MUST NOT BE connected until after all lines have been ushed to remove the small particles of debris that are inherent with new construction projects and all chemicals that are used in ushing are purged from the system.
Chemicals used in ushing plumbing systems can attack the internal components of the valve and spray head and severely damage them, so any ushing of the system must be followed by a full ushing with pure water to clear any harsh chemicals remaining in the system. Debris in the system if allowed to enter the valve assembly and spray head can cause poor performance or outright failure.
Again DO NOT attempt to connect the valve assembly and spray head until after all ushing is complete and pure water is the only media that will be passing through the system. Damage to the
valve assembly or spray head caused by harsh chemicals or debris will not be covered by the manufacturer's warranty�
Any ttings provided by the installer should be made of plastic to electrically isolate the unit from the building or connected plumbing system.
The grounding of electric equipment such as telephones, computers, etc, to water lines is a common procedure. This grounding can cause electrical feedback into a water fountain or similar xture, causing electrolysis, which results in a metallic taste or an increase in the metal content of the water. This can easily be avoided by using the proper materials as indicated.
Check Rough-In location PRIOR to installation
Flush lines thoroughly PRIOR to hook-up
Willoughby Stainless Fountains
TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837
Page 3Rev. 3/2018 www.willoughbystainlessfountains.com
Outdoor Drinking Fountains
WODF Series
Installation & Operation Manual
Standard Fountain Congurations-
WODF Series
WODF-1
WODF-3-CHD-PET WODF-3-HC-PET WODF-3-HC-CHD
WODF-2-PET
WODF-2-CHD
WODF-2-HC
Willoughby Stainless Fountains
TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837
Page 4Rev. 3/2018 www.willoughbystainlessfountains.com
Outdoor Drinking Fountains
WODF Series
Installation & Operation Manual
Physical Dimensions- WODF-1
*WODF-1 shown; for WODF-2 and WODF-3 model variations, refer to factory drawings. Contact Willoughby Stainless Fountains if further information is needed.
Willoughby Stainless Fountains
TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837
Page 5Rev. 3/2018 www.willoughbystainlessfountains.com
Outdoor Drinking Fountains
WODF Series
Installation & Operation Manual
Rough-in Dimensions- WODF Series
*WODF-1 shown; applicable to all WODF-2 and WODF-3 model variations without Pet Fountain
Willoughby Stainless Fountains
TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837
Page 6Rev. 3/2018 www.willoughbystainlessfountains.com
Outdoor Drinking Fountains
WODF Series
Installation & Operation Manual
Rough-in Dimensions- WODF Series w/ Pet Fountain
*WODF-2-PET shown; applicable to all WODF-2 and WODF-3 model variations with Pet Fountain
Willoughby Stainless Fountains
TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837
Page 7Rev. 3/2018 www.willoughbystainlessfountains.com
Outdoor Drinking Fountains
WODF Series
Required Installation Supplies
Proper mounting hardware
Proper plastic ttings as indicated
Hardware for waste oulet connections
Gasket for waste outlet connection
Shims (for installation if necessary)
Supply piping
Silicone caulk
Installation & Operation Manual
Plumbers putty
 WARNING: Willoughby Stainless Fountains does not assume
any responsibility for personal injury or damage to equipment due to an improperly installed WODF Series Drinking Fountain
Willoughby Stainless Fountains
TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837
Page 8Rev. 3/2018 www.willoughbystainlessfountains.com